Catalyst 6500 Series Switches Installation Guide - Ipland
Catalyst 6500 Series Switches Installation Guide - Ipland Catalyst 6500 Series Switches Installation Guide - Ipland
WS-X6408 8 PORT GIGABIT ETHERNET WS-X6408 WS-X6408 8 PORT GIGABIT ETHERNET WS-X6408 8 PORT GIGABIT ETHERNET WS-SUP32-GE-3B WS-SUP32-GE-3B 1 1 1 1 CONSOLE CONSOLE EJECT EJECT PORT 9 PORT 9 USB 2.0 USB 2.0 Catalyst 6506-E Switch Chapter 1 Product Overview Catalyst 6506-E Switch The Catalyst 6506-E switch is an enhanced version of the Catalyst 6506 switch. The 6-slot horizontal chassis supports redundant power supplies, redundant supervisor engines, and slots for up to five modules. It also supports a greater power capacity per slot than the Catalyst 6506 switch chassis. The Catalyst 6506-E switch chassis is NEBS L3 compliant. Figure 1-8 shows a front view of the Catalyst 6506-E switch. Figure 1-8 Catalyst 6506-E Switch 1 STATUS 2 3 4 5 6 7 8 Switching modules 2 3 8 PORT GIGABIT ETHERNET STATUS STATUS LINK LINK LINK 2 3 4 5 6 7 8 LINK LINK LINK LINK LINK 2 3 4 5 6 7 8 LINK LINK LINK LINK LINK LINK LINK LINK 4 STATUS LINK LINK LINK LINK LINK LINK 2 3 4 5 6 7 8 LINK LINK Fan assembly Supervisor engine FAN STATUS 5 6 STATUS SYSTEM ACTIVE PWR MGMT CATALYST 6500 SUPERVISOR ENGINE 32 STATUS SYSTEM ACTIVE PWR MGMT CATALYST 6500 SUPERVISOR ENGINE 32 LINK RESET RESET LINK LINK LINK DISK 0 PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 LINK LINK LINK LINK LINK LINK LINK LINK LINK LINK DISK 0 PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 LINK LINK LINK Redundant supervisor engine LINK LINK LINK LINK LINK LINK LINK LINK LINK o o INPUT FAN OUTPUT OK OK FAIL INPUT FAN OUTPUT OK OK FAIL Power supply 1 Power supply 2 (redundant) ESD ground strap connector 18224 Table 1-9 lists the features of the Catalyst 6506-E switch chassis. 1-24 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Chapter 1 Product Overview Catalyst 6506-E Switch Table 1-9 Catalyst 6506-E Switch Features Feature Descriptions Chassis • Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom). Supervisor engines • Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T. Note Refer to your software release notes for the minimum software release versions required to support the supervisor engines. Note – Supervisor Engine 2 must be installed in slot 1 and slot 2. – Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T must be installed in slot 5 and slot 6. Slots not occupied by supervisor engines can be used for modules. Check your software release notes for any restrictions on the type of module that can be installed. • Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have a built-in switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not supported. • Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). • The uplink ports are fully functional on the redundant supervisor engine in standby mode. Note In systems with redundant supervisor engines, both supervisor engines must be the same model and have the same daughter card configurations. Each supervisor engine must have the resources to run the switch on its own, which means that all supervisor engine resources are duplicated. Identical supervisor engine memory configurations are recommended, but are not required as long as the supervisor engine with the smaller memory configuration is sufficient to run the configured features of the switch. Additionally, each supervisor engine must have its own flash device and console port connections. OL-5781-08 Catalyst 6500 Series Switches Installation Guide 1-25
- Page 1 and 2: Catalyst 6500 Series Switches Insta
- Page 3: NOTWITHSTANDING ANY OTHER WARRANTY
- Page 6 and 7: Contents Power Source Interruptions
- Page 8 and 9: Contents Attaching the Interface Ca
- Page 10 and 11: Contents 100-MB Transceivers B-1 1-
- Page 12 and 13: Conventions Preface Chapter Title D
- Page 14 and 15: Conventions Preface Warnings use th
- Page 16 and 17: Conventions Preface Varning! VIKTIG
- Page 18 and 19: Conventions Preface xviii Catalyst
- Page 20 and 21: Related Documentation Preface Obtai
- Page 22 and 23: WS-SUP32-GE-3B Catalyst 6503 Switch
- Page 24 and 25: Catalyst 6503 Switch Chapter 1 Prod
- Page 26 and 27: Catalyst 6503 Switch Chapter 1 Prod
- Page 28 and 29: WS-SUP32-GE-3B Catalyst 6503-E Swit
- Page 30 and 31: Catalyst 6503-E Switch Chapter 1 Pr
- Page 32 and 33: Catalyst 6503-E Switch Chapter 1 Pr
- Page 34 and 35: Catalyst 6504-E Switch Chapter 1 Pr
- Page 36 and 37: Catalyst 6504-E Switch Chapter 1 Pr
- Page 38 and 39: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 40 and 41: Catalyst 6506 Switch Chapter 1 Prod
- Page 42 and 43: Catalyst 6506 Switch Chapter 1 Prod
- Page 46 and 47: Catalyst 6506-E Switch Chapter 1 Pr
- Page 48 and 49: Catalyst 6506-E Switch Chapter 1 Pr
- Page 50 and 51: WS-X6408 WS-X6408 WS-X6408 WS-X6408
- Page 52 and 53: Catalyst 6509 Switch Chapter 1 Prod
- Page 54 and 55: Catalyst 6509 Switch Chapter 1 Prod
- Page 56 and 57: WS-X6408 WS-X6408 WS-X6408 WS-X6408
- Page 58 and 59: Catalyst 6509-E Switch Chapter 1 Pr
- Page 60 and 61: Catalyst 6509-E Switch Chapter 1 Pr
- Page 62 and 63: FAN STATUS LINK LINK LINK LINK LINK
- Page 64 and 65: Catalyst 6509-NEB Switch Chapter 1
- Page 66 and 67: Catalyst 6509-NEB Switch Chapter 1
- Page 68 and 69: Catalyst 6509-NEB Switch Chapter 1
- Page 70 and 71: Catalyst 6509-NEB-A Switch Chapter
- Page 72 and 73: Catalyst 6509-NEB-A Switch Chapter
- Page 74 and 75: Catalyst 6509-NEB-A Switch Chapter
- Page 76 and 77: Catalyst 6509-V-E Switch Chapter 1
- Page 78 and 79: Catalyst 6509-V-E Switch Chapter 1
- Page 80 and 81: Catalyst 6509-V-E Switch Chapter 1
- Page 82 and 83: Catalyst 6513 Switch Chapter 1 Prod
- Page 84 and 85: Catalyst 6513 Switch Chapter 1 Prod
- Page 86 and 87: Catalyst 6513 Switch Chapter 1 Prod
- Page 88 and 89: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 90 and 91: Catalyst 6513-E Switch Chapter 1 Pr
- Page 92 and 93: Catalyst 6513-E Switch Chapter 1 Pr
Chapter 1<br />
Product Overview<br />
<strong>Catalyst</strong> 6506-E Switch<br />
Table 1-9<br />
<strong>Catalyst</strong> 6506-E Switch Features<br />
Feature<br />
Descriptions<br />
Chassis • Six horizontal slots. Slots are numbered from 1 (top) to 6 (bottom).<br />
Supervisor engines • Supports Supervisor Engine 2, Supervisor Engine 32, Supervisor<br />
Engine 32 PISA, Supervisor Engine 720, Supervisor Engine 720-10GE,<br />
and Supervisor Engine 2T.<br />
Note<br />
Refer to your software release notes for the minimum software<br />
release versions required to support the supervisor engines.<br />
Note<br />
– Supervisor Engine 2 must be installed in slot 1 and slot 2.<br />
– Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor<br />
Engine 720, Supervisor Engine 720-10GE, and Supervisor<br />
Engine 2T must be installed in slot 5 and slot 6.<br />
Slots not occupied by supervisor engines can be used for modules.<br />
Check your software release notes for any restrictions on the type of<br />
module that can be installed.<br />
• Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor<br />
Engine 2T have a built-in switching fabric. Switch Fabric Modules<br />
(WS-C<strong>6500</strong>-SFM and WS-X<strong>6500</strong>-SFM2) are not supported.<br />
• Supervisor Engine 32 and Supervisor Engine 32 PISA do not support<br />
the Switch Fabric Modules (WS-C<strong>6500</strong>-SFM and WS-X<strong>6500</strong>-SFM2).<br />
• The uplink ports are fully functional on the redundant supervisor engine<br />
in standby mode.<br />
Note<br />
In systems with redundant supervisor engines, both supervisor<br />
engines must be the same model and have the same daughter card<br />
configurations. Each supervisor engine must have the resources to<br />
run the switch on its own, which means that all supervisor engine<br />
resources are duplicated. Identical supervisor engine memory<br />
configurations are recommended, but are not required as long as the<br />
supervisor engine with the smaller memory configuration is<br />
sufficient to run the configured features of the switch. Additionally,<br />
each supervisor engine must have its own flash device and console<br />
port connections.<br />
OL-5781-08<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
1-25