Module Connectors<br />

Appendix B<br />

Transceivers, Module Connectors, and Cable Specifications<br />

Caution<br />

Category 5e and Category 6 cables can store large levels of static electricity because of the dielectric<br />

properties of the materials used in their construction. Always ground the cables (especially in new cable<br />

runs) to a suitable and safe earth ground before connecting them to the module.<br />

Caution<br />

To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use foil-twisted pair<br />

(FTP) cable that is properly grounded at both ends.<br />

Table B-23<br />

RJ-21 Connector Pinout<br />

Ethernet Port<br />

No.<br />

Connector Pin<br />

No.<br />

Signal<br />

Connector Pin<br />

No.<br />

Signal<br />

1 1<br />

2<br />

RxD (–)<br />

TxD (–)<br />

26<br />

27<br />

RxD (+)<br />

TxD (+)<br />

2 3<br />

4<br />

RxD (–)<br />

TxD (–)<br />

28<br />

29<br />

RxD (+)<br />

TxD (+)<br />

3 5<br />

6<br />

RxD (–)<br />

TxD (–)<br />

30<br />

31<br />

RxD (+)<br />

TxD (+)<br />

4 7<br />

8<br />

RxD (–)<br />

TxD (–)<br />

32<br />

33<br />

RxD (+)<br />

TxD (+)<br />

5 9<br />

10<br />

RxD (–)<br />

TxD (–)<br />

34<br />

35<br />

RxD (+)<br />

TxD (+)<br />

6 11<br />

12<br />

RxD (–)<br />

TxD (–)<br />

36<br />

37<br />

RxD (+)<br />

TxD (+)<br />

7 13<br />

14<br />

RxD (–)<br />

TxD (–)<br />

38<br />

39<br />

RxD (+)<br />

TxD (+)<br />

8 15<br />

16<br />

RxD (–)<br />

TxD (–)<br />

40<br />

41<br />

RxD (+)<br />

TxD (+)<br />

9 17<br />

18<br />

RxD (–)<br />

TxD (–)<br />

42<br />

43<br />

RxD (+)<br />

TxD (+)<br />

10 19<br />

20<br />

RxD (–)<br />

TxD (–)<br />

44<br />

45<br />

RxD (+)<br />

TxD (+)<br />

11 21<br />

22<br />

RxD (–)<br />

TxD (–)<br />

46<br />

47<br />

RxD (+)<br />

TxD (+)<br />

12 23<br />

24<br />

RxD (–)<br />

TxD (–)<br />

48<br />

49<br />

RxD (+)<br />

TxD (+)<br />

— 25 Gnd 50 Gnd<br />

B-26<br />