Pluggable Transceivers<br />

Appendix B<br />

Transceivers, Module Connectors, and Cable Specifications<br />

Table B-6 lists the fiber loss budgets for the GBIC transceivers.<br />

Table B-6<br />

Fiber Loss Budgets for the 1-GB GBIC Transceivers<br />

1-GB GBIC Transceiver<br />

Product Number<br />

WS-G5484<br />

(1000BASE-SX)<br />

WS-G5486<br />

(1000BASE-LX/LH)<br />

WS-G5487<br />

(1000BASE-ZX)<br />

Transmit (dBm)<br />

–3 (maximum)<br />

–9.5 (minimum)<br />

–3 (maximum)<br />

–9.5 (minimum)<br />

5 (maximum)<br />

0 (minimum)<br />

Receive (dBm)<br />

0 (maximum)<br />

–17 (minimum)<br />

–3 (maximum)<br />

–19 (minimum)<br />

–3 (maximum)<br />

–23 (minimum) 1<br />

1. The 1000BASE-ZX GBIC transceiver provides a minimum optical power budget of<br />

23 dB. To determine the supported link distance, you need to measure your cable plant<br />

with an optical loss test set to verify that the optical loss of the cable plant (including<br />

connectors and splices) is less than or equal to this value. The optical measurement<br />

must be performed with a 1550 nanometer light source.<br />

Table B-7 lists the physical and environmental specifications for the GBIC transceivers.<br />

Table B-7<br />

1-GB GBIC Transceiver Physical and Environmental Specifications<br />

Item<br />

Dimensions (H x W x D)<br />

Operating temperature<br />

Storage temperature<br />

Specification<br />

0.75 x 1.54 x 3.50 inches (19.0 x 39.1 x 88.9 mm)<br />

32° to 122°F (0° to 50°C)<br />

–40° to 185°F (–40° to 85°C)<br />