Pluggable Transceivers Appendix B Transceivers, Module Connectors, and Cable Specifications Figure B-1 100-MB SFP Transceiver Module GLC-SX-MMClass 1 21CFR1040.10 LN#50 7/01 03-13 S/N: OH1233456 Dust plug Receive optical bore Transmit optical bore Bail clasp 130927 Table B-1 100-MB SFP Transceiver Cabling Specifications 100-MB SFP Transceiver Product Number GLC-FE-100FX GLC-FE-100LX GLC-FE-100BX-D GLC-FE-100BX-U GLC-FE-100EX GLC-FE-100ZX Description 100BASE-FX SFP for 100 Mb (Fast Ethernet) ports 100BASE-LX10 SFP for 100 Mb (Fast Ethernet) ports 100BASE-FX SFP for 100 Mb (Fast Ethernet) ports 100BASE-FX SFP for 100 Mb (Fast Ethernet) ports 100BASE-EX for 100 Mb (Fast Ethernet) ports 100BASE-ZX for 100 Mb (Fast Ethernet) ports Interface Connector Nominal Wavelength (nm) Network Cable Type Fiber Core Size 1 (micron) Cable Distance 2 Dual LC 1310 MMF 50/62.5 1.24 miles (2 km) Dual LC 1310 SMF G.652 3 Single LC Single LC 1550 (receive) 1310 (transmit) 1310 (receive) 1550 (transmit) Single-strand SMF Single-strand SMF 6.21 miles (10 km) G.652 3 6.21 miles (10 km) G.652 3 6.21 miles (10 km) Dual LC 1310 SMF G.652 3 24.86 miles (40 km) Dual LC 1550 SMF G.652 3 49.7 miles (80 km) 1. The numbers given for multimode fiber-optic (MMF) cable refer to the core diameter. 2. Cable distances are based on fiber loss. Additional factors, such as the number of splices and the optical quality of the fiber, can affect cabling distances. 3. ITU-T G.652 SMF as specified by the IEEE 802.3z standard. Note The minimum cable distance for all 100-MB SFP transceivers listed, both MMF and SMF (G.652), is 6.5 feet (2 meters). B-2 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Appendix B Transceivers, Module Connectors, and Cable Specifications Pluggable Transceivers Table B-2 lists the fiber loss budgets for the 100-MB SFP transceivers. Table B-2 Fiber Loss Budgets for the 100-MB SFP Transceivers 100-MB SFP Transceiver Product Number GLC-FE-100FX GLC-FE-100LX GLC-FE-100BX-U GLC-FE-100BX-D GLC-FE-100EX GLC-FE-100ZX Transmit (dBm) –14 (maximum) –20 (minimum) –8 (maximum) –15 (minimum) –8 (maximum) –14 (minimum) –8 (maximum) –14 (minimum) 0 (maximum) –5 (minimum) 2 (maximum) –3 (minimum) Receive (dBm) –14 (maximum) –31 (minimum) –8 (maximum) –28 (minimum) –7 (maximum) –28.2 (minimum) –7 (maximum) –28.2 (minimum) –8 (maximum) –28 (minimum) –8 (maximum) –30 (minimum) Table B-3 lists the physical and environmental specifications for the 100-MB SFP transceivers. Table B-3 100-MB SFP Transceiver Physical and Environmental Specifications Item Dimensions (H x W x D) Operating temperature Storage temperature Specification 0.04 x 0.53 x 2.22 in. (8.5 x 13.4 x 56.5 mm) 32° to 122°F (0° to 50°C) –40° to 185°F (–40° to 85°C) 1-GB Transceivers The 1-GB transceivers include the Gigabit Interface Converter (GBIC) transceiver and the SFP transceiver. The GBIC transceivers and SFP transceivers differ in both form-factor and in connector type; they are not interchangeable. Table B-4 lists both 1-GB transceiver types, the modules that support them, the applicable transceiver illustrations, and the applicable specification tables. OL-5781-08 Catalyst 6500 Series Switches Installation Guide B-3
- Page 338 and 339: 2700 W AC-Input and DC-Input Power
- Page 340 and 341: 2700 W AC-Input and DC-Input Power
- Page 342 and 343: 2700 W AC-Input and DC-Input Power
- Page 344 and 345: 3000 W AC-Input Power Supply Append
- Page 346 and 347: 3000 W AC-Input Power Supply Append
- Page 348 and 349: 3000 W AC-Input Power Supply Append
- Page 350 and 351: 4000 W AC-Input and DC-Input Power
- Page 352 and 353: 4000 W AC-Input and DC-Input Power
- Page 354 and 355: 6000 W AC-Input and DC-Input Power
- Page 356 and 357: 6000 W AC-Input and DC-Input Power
- Page 358 and 359: 6000 W AC-Input and DC-Input Power
- Page 360 and 361: 6000 W AC-Input and DC-Input Power
- Page 362 and 363: 8700 W AC-Input Power Supply Append
- Page 364 and 365: 8700 W AC-Input Power Supply Append
- Page 366 and 367: 8700 W AC-Input Power Supply Append
- Page 368 and 369: 8700 W AC-Input Power Supply Append
- Page 370 and 371: 8700 W AC-Input Power Supply Append
- Page 372 and 373: AC Power Cord Illustrations Appendi
- Page 374 and 375: AC Power Cord Illustrations Appendi
- Page 376 and 377: AC Power Cord Illustrations Appendi
- Page 378 and 379: AC Power Cord Illustrations Appendi
- Page 380 and 381: AC Power Cord Illustrations Appendi
- Page 382 and 383: Power Supply Redundancy Appendix A
- Page 384 and 385: Power Supply Redundancy Appendix A
- Page 386 and 387: Power Supply Redundancy Appendix A
- Page 390 and 391: Pluggable Transceivers Appendix B T
- Page 392 and 393: Pluggable Transceivers Appendix B T
- Page 394 and 395: Pluggable Transceivers Appendix B T
- Page 396 and 397: Pluggable Transceivers Appendix B T
- Page 398 and 399: Pluggable Transceivers Appendix B T
- Page 400 and 401: Pluggable Transceivers Appendix B T
- Page 402 and 403: Pluggable Transceivers Appendix B T
- Page 404 and 405: Pluggable Transceivers Appendix B T
- Page 406 and 407: Pluggable Transceivers Appendix B T
- Page 408 and 409: Pluggable Transceivers Appendix B T
- Page 410 and 411: Module Connectors Appendix B Transc
- Page 412 and 413: Module Connectors Appendix B Transc
- Page 414 and 415: Module Connectors Appendix B Transc
- Page 416 and 417: Module Connectors Appendix B Transc
- Page 418 and 419: Cables Appendix B Transceivers, Mod
- Page 420 and 421: Cables Appendix B Transceivers, Mod
- Page 422 and 423: Cables Appendix B Transceivers, Mod
- Page 424 and 425: Cleaning the Fiber-Optic Connectors
- Page 426 and 427: Cleaning the Fiber-Optic Connectors
- Page 428 and 429: Appendix C Repacking the Switch Fig
- Page 430 and 431: Appendix D Chassis and Module Power
- Page 432 and 433: Appendix D Chassis and Module Power
- Page 434 and 435: Appendix D Chassis and Module Power
- Page 436 and 437: Appendix D Chassis and Module Power
Pluggable Transceivers<br />
Appendix B<br />
Transceivers, Module Connectors, and Cable Specifications<br />
Figure B-1<br />
100-MB SFP Transceiver Module<br />
GLC-SX-MMClass<br />
1 21CFR1040.10<br />
LN#50 7/01 03-13<br />
S/N: OH1233456<br />
Dust plug<br />
Receive optical bore<br />
Transmit optical bore<br />
Bail clasp<br />
130927<br />
Table B-1<br />
100-MB SFP Transceiver Cabling Specifications<br />
100-MB SFP<br />
Transceiver Product<br />
Number<br />
GLC-FE-100FX<br />
GLC-FE-100LX<br />
GLC-FE-100BX-D<br />
GLC-FE-100BX-U<br />
GLC-FE-100EX<br />
GLC-FE-100ZX<br />
Description<br />
100BASE-FX SFP for<br />
100 Mb (Fast Ethernet)<br />
ports<br />
100BASE-LX10 SFP<br />
for 100 Mb (Fast<br />
Ethernet) ports<br />
100BASE-FX SFP for<br />
100 Mb (Fast Ethernet)<br />
ports<br />
100BASE-FX SFP for<br />
100 Mb (Fast Ethernet)<br />
ports<br />
100BASE-EX for<br />
100 Mb (Fast Ethernet)<br />
ports<br />
100BASE-ZX for<br />
100 Mb (Fast Ethernet)<br />
ports<br />
Interface<br />
Connector<br />
Nominal<br />
Wavelength<br />
(nm)<br />
Network<br />
Cable Type<br />
Fiber Core<br />
Size 1<br />
(micron)<br />
Cable<br />
Distance 2<br />
Dual LC 1310 MMF 50/62.5 1.24 miles<br />
(2 km)<br />
Dual LC 1310 SMF G.652 3<br />
Single LC<br />
Single LC<br />
1550 (receive)<br />
1310 (transmit)<br />
1310 (receive)<br />
1550 (transmit)<br />
Single-strand<br />
SMF<br />
Single-strand<br />
SMF<br />
6.21 miles<br />
(10 km)<br />
G.652 3 6.21 miles<br />
(10 km)<br />
G.652 3 6.21 miles<br />
(10 km)<br />
Dual LC 1310 SMF G.652 3 24.86 miles<br />
(40 km)<br />
Dual LC 1550 SMF G.652 3 49.7 miles<br />
(80 km)<br />
1. The numbers given for multimode fiber-optic (MMF) cable refer to the core diameter.<br />
2. Cable distances are based on fiber loss. Additional factors, such as the number of splices and the optical quality of the fiber, can affect cabling distances.<br />
3. ITU-T G.652 SMF as specified by the IEEE 802.3z standard.<br />
Note<br />
The minimum cable distance for all 100-MB SFP transceivers listed, both MMF and SMF (G.652), is<br />
6.5 feet (2 meters).<br />
B-2<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
OL-5781-08