2700 W AC-Input and DC-Input Power Supplies Appendix A Power Supply Specifications Table A-23 2700 W AC-Input and DC-Input Power Supply LEDs LED INPUT 1 OK INPUT 2 OK (DC-input power supply only) Meaning AC-input power supplies: • Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) • Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. DC-input power supplies: • Green—Source DC is OK. (Input voltage is –40.5 VDC or greater.) • Off—Source DC voltage falls below –33 VDC, is not present, or the power supply is turned off. FAN OK • Green—Power supply fan is operating properly. • Off—Power supply fan failure is detected. OUTPUT FAIL • Red—Problem with one or more of the DC-output voltages of the power supply. • Off—DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. A-34 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Appendix A Power Supply Specifications 2700 W AC-Input and DC-Input Power Supplies 2700 W Power Supply AC Power Cords Table A-24 lists the specifications for the AC power cords that are available for the 2700 W AC-input power supply. The table includes references to power cord illustrations. Note All 2700 W power supply power cords are 14 feet (4.3 meters) in length. Note All 2700 W power supply power cords have an IEC60320/C19 appliance connector at one end. Table A-24 2700 W Power Supply AC Power Cords Locale Argentina Power Cord Part Number CAB-7513ACR= or CAB-IR2073-C19-AR= AC Source Plug Type Cordset Rating Power Cord Reference Illustration IRAM 2073 16 A, 250 VAC Figure A-31 Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-45 People’s Republic of China CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37 Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-41 International CAB-AC-2500W-INT= IEC 309 16 A, 250 VAC Figure A-42 Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34 Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35 Japan, North America CAB-AC-2500W-US1= NEMA 6-20 16 A, 250 VAC Figure A-43 200–240 VAC operation (nonlocking plug) Japan, North America CAB-AC-C6K-TWLK= NEMA L6-20 16 A, 250 VAC Figure A-44 200–240 VAC operation (locking plug) Japan, North America 100–120 VAC operation CAB-7513AC= NEMA 5-20 20 A, 125 VAC Figure A-36 Power Distribution Unit (PDU) 1 CAB-C19-CBN= IEC 60320 C19 IEC 60320 C20 16 A, 250 VAC Figure A-47 South Africa CAB-7513ACSA= IEC 884-1 16 A, 250 VAC Figure A-38 Switzerland CAB-ACS-16= SEV 5934-2 Type 23 16 A, 250 VAC Figure A-45 1. The PDU power cable is designed for users who power their switch from a PDU. The end of the cable that plugs into the chassis power supply has a C19 connector; the other end of the cable that connects to the PDU has a C20 connector. OL-5781-08 Catalyst 6500 Series Switches Installation Guide A-35
- Page 292 and 293: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 294 and 295: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 296 and 297: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 298 and 299: Removing and Installing the Fan Tra
- Page 300 and 301: ACTIVE TX RX RX TX ACTIVE TX RX RX
- Page 302 and 303: Installing the Air Filter Assembly
- Page 304 and 305: Installing the Remote Power Cycling
- Page 306 and 307: Installing the Remote Power Cycling
- Page 308 and 309: Installing the Remote Power Cycling
- Page 310 and 311: Power Supply Compatibility Matrix A
- Page 312 and 313: Power Supply Compatibility Matrix A
- Page 314 and 315: 950 W AC-Input and DC-Input Power S
- Page 316 and 317: 950 W AC-Input and DC-Input Power S
- Page 318 and 319: 1000 W AC-Input Power Supply Append
- Page 320 and 321: 1000 W AC-Input Power Supply Append
- Page 322 and 323: 1300 W AC-Input and DC-Input Power
- Page 324 and 325: 1300 W AC-Input and DC-Input Power
- Page 326 and 327: 1400 W AC-Input Power Supply Append
- Page 328 and 329: 1400 W AC-Input Power Supply Append
- Page 330 and 331: 1400 W AC-Input Power Supply Append
- Page 332 and 333: 2500 W AC-Input and DC-Input Power
- Page 334 and 335: 2500 W AC-Input and DC-Input Power
- Page 336 and 337: 2500 W AC-Input and DC-Input Power
- Page 338 and 339: 2700 W AC-Input and DC-Input Power
- Page 340 and 341: 2700 W AC-Input and DC-Input Power
- Page 344 and 345: 3000 W AC-Input Power Supply Append
- Page 346 and 347: 3000 W AC-Input Power Supply Append
- Page 348 and 349: 3000 W AC-Input Power Supply Append
- Page 350 and 351: 4000 W AC-Input and DC-Input Power
- Page 352 and 353: 4000 W AC-Input and DC-Input Power
- Page 354 and 355: 6000 W AC-Input and DC-Input Power
- Page 356 and 357: 6000 W AC-Input and DC-Input Power
- Page 358 and 359: 6000 W AC-Input and DC-Input Power
- Page 360 and 361: 6000 W AC-Input and DC-Input Power
- Page 362 and 363: 8700 W AC-Input Power Supply Append
- Page 364 and 365: 8700 W AC-Input Power Supply Append
- Page 366 and 367: 8700 W AC-Input Power Supply Append
- Page 368 and 369: 8700 W AC-Input Power Supply Append
- Page 370 and 371: 8700 W AC-Input Power Supply Append
- Page 372 and 373: AC Power Cord Illustrations Appendi
- Page 374 and 375: AC Power Cord Illustrations Appendi
- Page 376 and 377: AC Power Cord Illustrations Appendi
- Page 378 and 379: AC Power Cord Illustrations Appendi
- Page 380 and 381: AC Power Cord Illustrations Appendi
- Page 382 and 383: Power Supply Redundancy Appendix A
- Page 384 and 385: Power Supply Redundancy Appendix A
- Page 386 and 387: Power Supply Redundancy Appendix A
- Page 388 and 389: Pluggable Transceivers Appendix B T
- Page 390 and 391: Pluggable Transceivers Appendix B T
2700 W AC-Input and DC-Input Power Supplies<br />
Appendix A<br />
Power Supply Specifications<br />
Table A-23<br />
2700 W AC-Input and DC-Input Power Supply LEDs<br />
LED<br />
INPUT 1 OK<br />
INPUT 2 OK (DC-input<br />
power supply only)<br />
Meaning<br />
AC-input power supplies:<br />
• Green—Source AC voltage is OK. (Input voltage is 85 VAC or<br />
greater.)<br />
• Off—Source AC voltage falls below 70 VAC, is not present, or the<br />
power supply is turned off.<br />
DC-input power supplies:<br />
• Green—Source DC is OK. (Input voltage is –40.5 VDC or greater.)<br />
• Off—Source DC voltage falls below –33 VDC, is not present, or the<br />
power supply is turned off.<br />
FAN OK • Green—Power supply fan is operating properly.<br />
• Off—Power supply fan failure is detected.<br />
OUTPUT FAIL • Red—Problem with one or more of the DC-output voltages of the<br />
power supply.<br />
• Off—DC-output voltages within acceptable margins.<br />
Note<br />
For proper operation of the OUTPUT FAIL LED, systems with<br />
single power supplies must be configured with a minimum of<br />
one fan tray and one supervisor engine. Systems with dual power<br />
supplies must have a minimum configuration of one fan tray, one<br />
supervisor engine, and one additional module. Failure to meet<br />
these minimum configuration requirements can cause a false<br />
power supply output fail signal.<br />
A-34<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
OL-5781-08