1400 W AC-Input Power Supply Appendix A Power Supply Specifications Table A-14 1400 W AC-Input Power Supply Specifications (continued) Specification Branch circuit requirement Power supply output capacity Each chassis power supply should have its own dedicated, fused-branch circuit: • For North America—20 A Power supply output • 15 A @ +1.5 V Output holdup time kVA rating 1 Heat dissipation Weight Description • For International—Circuits sized to local and national codes • All AC power supply inputs are fully isolated. – Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B. – For high-line operation, the power supply operates with the hot conductor wired to a source AC phase and the neutral conductor wired either to ground or to another source AC phase as long as the net input voltage is in the range of 170 to 264 VAC. – Source AC can be out of phase between AC inputs on power supplies that are equipped with multiple AC inputs, which means that power cord 1 can be plugged into phase A and power cord 2 can be plugged into phase B. 1400 W • 2.5 A @ +3.3 V • 27.4 A @ +50 V 20 ms minimum 1.75 kVA 5976 BTU/hour (approx.) 7.8 lb (3.5 kg) 1. The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch. Table A-15 lists the 1400 W AC-input power supply LEDs and their meanings. A-20 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Appendix A Power Supply Specifications 1400 W AC-Input Power Supply Table A-15 1400 W AC-Input Power Supply LEDs LED Meaning INPUT OK • Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) • Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. FAN OK • Green—Power supply fan is operating properly. • Off—Power supply fan failure is detected. OUTPUT FAIL • Red—Problem with one or more of the DC-output voltages of the power supply is detected. • DC-output voltages within acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. 1400 W Power Supply AC Power Cords Table A-16 lists the specifications for the AC power cords that are available for the 1400 W AC-input power supply. These power cords plug into the 1400 W PEM (PEM-20A-AC+); not directly into the power supply. The table includes references to power cord illustrations. Note All 1400 W power supply power cords are 14 feet (4.3 meters) in length. Note All 1400 W power supply power cords have an IEC60320/C19 appliance plug at one end. OL-5781-08 Catalyst 6500 Series Switches Installation Guide A-21
- Page 278 and 279: Removing and Installing the DC-Inpu
- Page 280 and 281: CISCO SYSTEMS, INC 1 2 3 4 INPUT OK
- Page 282 and 283: Removing and Installing PEMs Chapte
- Page 284 and 285: Removing and Installing PEMs Chapte
- Page 286 and 287: OSM-4OC12 POS-SI 1 2 1 2 1 1 2 2 3
- Page 288 and 289: Removing and Installing the Fan Tra
- Page 290 and 291: WS-X6K-SUP2-2GE OSM-4OC12 POS-SI OS
- Page 292 and 293: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 294 and 295: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 296 and 297: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 298 and 299: Removing and Installing the Fan Tra
- Page 300 and 301: ACTIVE TX RX RX TX ACTIVE TX RX RX
- Page 302 and 303: Installing the Air Filter Assembly
- Page 304 and 305: Installing the Remote Power Cycling
- Page 306 and 307: Installing the Remote Power Cycling
- Page 308 and 309: Installing the Remote Power Cycling
- Page 310 and 311: Power Supply Compatibility Matrix A
- Page 312 and 313: Power Supply Compatibility Matrix A
- Page 314 and 315: 950 W AC-Input and DC-Input Power S
- Page 316 and 317: 950 W AC-Input and DC-Input Power S
- Page 318 and 319: 1000 W AC-Input Power Supply Append
- Page 320 and 321: 1000 W AC-Input Power Supply Append
- Page 322 and 323: 1300 W AC-Input and DC-Input Power
- Page 324 and 325: 1300 W AC-Input and DC-Input Power
- Page 326 and 327: 1400 W AC-Input Power Supply Append
- Page 330 and 331: 1400 W AC-Input Power Supply Append
- Page 332 and 333: 2500 W AC-Input and DC-Input Power
- Page 334 and 335: 2500 W AC-Input and DC-Input Power
- Page 336 and 337: 2500 W AC-Input and DC-Input Power
- Page 338 and 339: 2700 W AC-Input and DC-Input Power
- Page 340 and 341: 2700 W AC-Input and DC-Input Power
- Page 342 and 343: 2700 W AC-Input and DC-Input Power
- Page 344 and 345: 3000 W AC-Input Power Supply Append
- Page 346 and 347: 3000 W AC-Input Power Supply Append
- Page 348 and 349: 3000 W AC-Input Power Supply Append
- Page 350 and 351: 4000 W AC-Input and DC-Input Power
- Page 352 and 353: 4000 W AC-Input and DC-Input Power
- Page 354 and 355: 6000 W AC-Input and DC-Input Power
- Page 356 and 357: 6000 W AC-Input and DC-Input Power
- Page 358 and 359: 6000 W AC-Input and DC-Input Power
- Page 360 and 361: 6000 W AC-Input and DC-Input Power
- Page 362 and 363: 8700 W AC-Input Power Supply Append
- Page 364 and 365: 8700 W AC-Input Power Supply Append
- Page 366 and 367: 8700 W AC-Input Power Supply Append
- Page 368 and 369: 8700 W AC-Input Power Supply Append
- Page 370 and 371: 8700 W AC-Input Power Supply Append
- Page 372 and 373: AC Power Cord Illustrations Appendi
- Page 374 and 375: AC Power Cord Illustrations Appendi
- Page 376 and 377: AC Power Cord Illustrations Appendi
Appendix A<br />
Power Supply Specifications<br />
1400 W AC-Input Power Supply<br />
Table A-15<br />
1400 W AC-Input Power Supply LEDs<br />
LED<br />
Meaning<br />
INPUT OK • Green—Source AC voltage is OK. (Input voltage is 85 VAC or<br />
greater.)<br />
• Off—Source AC voltage falls below 70 VAC, is not present, or the<br />
power supply is turned off.<br />
FAN OK • Green—Power supply fan is operating properly.<br />
• Off—Power supply fan failure is detected.<br />
OUTPUT FAIL • Red—Problem with one or more of the DC-output voltages of the<br />
power supply is detected.<br />
• DC-output voltages within acceptable margins.<br />
Note<br />
For proper operation of the OUTPUT FAIL LED, systems with<br />
single power supplies must be configured with a minimum of<br />
one fan tray and one supervisor engine. Systems with dual power<br />
supplies must have a minimum configuration of one fan tray, one<br />
supervisor engine, and one additional module. Failure to meet<br />
these minimum configuration requirements can cause a false<br />
power supply output fail signal.<br />
1400 W Power Supply AC Power Cords<br />
Table A-16 lists the specifications for the AC power cords that are available for the 1400 W AC-input<br />
power supply. These power cords plug into the 1400 W PEM (PEM-20A-AC+); not directly into the<br />
power supply. The table includes references to power cord illustrations.<br />
Note<br />
All 1400 W power supply power cords are 14 feet (4.3 meters) in length.<br />
Note<br />
All 1400 W power supply power cords have an IEC60320/C19 appliance plug at one end.<br />
OL-5781-08<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />