Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Chapter 4 Removal and Replacement Procedures Figure 4-76 Placing the Foam Filter Over the Filter Retainer 3 5 2 1 4 104899 1 Filter cage assembly 4 Tabs 2 Filter 5 Thumb loops 3 Filter retainer Step 6 Install the filter assembly with the tabs facing the floor, as follows: a. Fit the tabs (see Figure 4-76) on the bottom of the filter cage assembly into the lower support loops. (See Figure 4-74.) b. Rotate the filter assembly towards the intake panel. (See Figure 4-77.) c. Tighten the two fastening screws. 4-96 Catalyst 6500 Series Switches Installation Guide OL-5781-08
ACTIVE TX RX RX TX ACTIVE TX RX RX TX TX RX RX TX Chapter 4 Removal and Replacement Procedures Installing the Air Filter Assembly on a Catalyst 6509-NEB-A Switch or a Catalyst 6509-V-E (Optional) Figure 4-77 Installing the Filter Assembly 1 2 1 LINK PORT 2 PORT 2 o o INPUT FAN OUTPUT OK OK FAIL INPUT FAN OUTPUT OK OK FAIL 104900 1 Thumbscrews 2 Fastening screw Step 7 After installing the optional air filter assembly, establish a schedule for visually checking the air filter for contamination. (See “Checking the Air Filter” section on page 4-98.) OL-5781-08 Catalyst 6500 Series Switches Installation Guide 4-97
- Page 252 and 253: Removing and Installing the DC-Inpu
- Page 254 and 255: Removing and Installing the DC-Inpu
- Page 256 and 257: Removing and Installing the DC-Inpu
- Page 258 and 259: Removing and Installing the DC-Inpu
- Page 260 and 261: Removing and Installing the DC-Inpu
- Page 262 and 263: Removing and Installing the DC-Inpu
- Page 264 and 265: Removing and Installing the DC-Inpu
- Page 266 and 267: CISCO SYSTEMS, INC Removing and Ins
- Page 268 and 269: CISCO SYSTEMS, INC 1 2 3 4 INPUT OK
- Page 270 and 271: Removing and Installing the DC-Inpu
- Page 272 and 273: CISCO SYSTEMS, INC Removing and Ins
- Page 274 and 275: Removing and Installing the DC-Inpu
- Page 276 and 277: Removing and Installing the DC-Inpu
- Page 278 and 279: Removing and Installing the DC-Inpu
- Page 280 and 281: CISCO SYSTEMS, INC 1 2 3 4 INPUT OK
- Page 282 and 283: Removing and Installing PEMs Chapte
- Page 284 and 285: Removing and Installing PEMs Chapte
- Page 286 and 287: OSM-4OC12 POS-SI 1 2 1 2 1 1 2 2 3
- Page 288 and 289: Removing and Installing the Fan Tra
- Page 290 and 291: WS-X6K-SUP2-2GE OSM-4OC12 POS-SI OS
- Page 292 and 293: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 294 and 295: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 296 and 297: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 298 and 299: Removing and Installing the Fan Tra
- Page 300 and 301: ACTIVE TX RX RX TX ACTIVE TX RX RX
- Page 304 and 305: Installing the Remote Power Cycling
- Page 306 and 307: Installing the Remote Power Cycling
- Page 308 and 309: Installing the Remote Power Cycling
- Page 310 and 311: Power Supply Compatibility Matrix A
- Page 312 and 313: Power Supply Compatibility Matrix A
- Page 314 and 315: 950 W AC-Input and DC-Input Power S
- Page 316 and 317: 950 W AC-Input and DC-Input Power S
- Page 318 and 319: 1000 W AC-Input Power Supply Append
- Page 320 and 321: 1000 W AC-Input Power Supply Append
- Page 322 and 323: 1300 W AC-Input and DC-Input Power
- Page 324 and 325: 1300 W AC-Input and DC-Input Power
- Page 326 and 327: 1400 W AC-Input Power Supply Append
- Page 328 and 329: 1400 W AC-Input Power Supply Append
- Page 330 and 331: 1400 W AC-Input Power Supply Append
- Page 332 and 333: 2500 W AC-Input and DC-Input Power
- Page 334 and 335: 2500 W AC-Input and DC-Input Power
- Page 336 and 337: 2500 W AC-Input and DC-Input Power
- Page 338 and 339: 2700 W AC-Input and DC-Input Power
- Page 340 and 341: 2700 W AC-Input and DC-Input Power
- Page 342 and 343: 2700 W AC-Input and DC-Input Power
- Page 344 and 345: 3000 W AC-Input Power Supply Append
- Page 346 and 347: 3000 W AC-Input Power Supply Append
- Page 348 and 349: 3000 W AC-Input Power Supply Append
- Page 350 and 351: 4000 W AC-Input and DC-Input Power
Installing the Air Filter Assembly on a <strong>Catalyst</strong> 6509-NEB-A Switch or a <strong>Catalyst</strong> 6509-V-E (Optional)<br />
Chapter 4<br />
Removal and Replacement Procedures<br />
Figure 4-76<br />
Placing the Foam Filter Over the Filter Retainer<br />
3<br />
5<br />
2<br />
1<br />
4<br />
104899<br />
1 Filter cage assembly 4 Tabs<br />
2 Filter 5 Thumb loops<br />
3 Filter retainer<br />
Step 6<br />
Install the filter assembly with the tabs facing the floor, as follows:<br />
a. Fit the tabs (see Figure 4-76) on the bottom of the filter cage assembly into the lower support loops.<br />
(See Figure 4-74.)<br />
b. Rotate the filter assembly towards the intake panel. (See Figure 4-77.)<br />
c. Tighten the two fastening screws.<br />
4-96<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
OL-5781-08