CISCO SYSTEMS, INC<br />

1 2 3 4<br />

INPUT OK<br />

FAN<br />

OK<br />

Chapter 4<br />

Removal and Replacement Procedures<br />

Removing and Installing the DC-Input Power Supplies<br />

Note<br />

You should allow a minimum of 2.5 to 3 inches (63.5 mm to 76.2 mm) of space between the side of the<br />

power supply and any obstructions (such as the side of an enclosed equipment rack). This space is needed<br />

to install and secure the DC-input power cables correctly. Incorrectly routing the DC-input power cables<br />

can cause airflow blockage into the power supply and inadequate strain relief in the cables. The exact<br />

amount of space required depends upon the gauge and flexibility of the DC-input power cables you are<br />

using.<br />

To install a 6000 W DC-input power supply, follow these steps:<br />

Step 1<br />

Verify that power is off to the DC circuit that is connected to the power supply you are installing. Place<br />

appropriate safety flag and lockout devices at power switch handle to avoid any circuit inputs from<br />

becoming energized.<br />

Caution<br />

Step 2<br />

Use both hands to install and remove power supplies. Each 6000 W DC-input power supply weighs<br />

35 pounds (16 kg).<br />

Grasp the power supply handle with one hand, and place your other hand underneath the power supply.<br />

Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the<br />

bay (Figure 4-46).<br />

Figure 4-46<br />

Handling a DC-Input Power Supply<br />

RUN<br />

INSTALL<br />

OUTPUT<br />

FAIL<br />

Step 3 Tighten the power supply captive installation screw (see Figure 4-47).<br />

OL-5781-08<br />

<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />