Catalyst 6500 Series Switches Installation Guide - Ipland
Catalyst 6500 Series Switches Installation Guide - Ipland Catalyst 6500 Series Switches Installation Guide - Ipland
CISCO SYSTEMS, INC Removing and Installing the DC-Input Power Supplies Chapter 4 Removal and Replacement Procedures Figure 4-41 DC-Input Front Panel for 6000-W DC-Input Power Supply 1 7 2 3 8 8 9 9 RUN INSTALL 191286 5 1 2 3 4 INPUT OK FAN OK OUTPUT FAIL 6 4 1 Terminal block cover 6 Captive installation screw 2 DC power cable terminal block 7 Input Power Module (IPM) 3 Ground 8 IPM captive screws 4 Status LEDs 9 IPM latches 5 Power switch Note Step 3 Step 4 With the PWR-6000-DC power supply, you have the option of removing the Input Power Module (IPM) without disconnecting the DC-input wires and the ground wires. You can then replace your power supply and insert the fully-wired IPM. To use this option, do not perform steps 3 through 6 and go to step 7. Remove the two A4 screws securing the terminal block cover, and remove the cover from the power supply (Figure 4-42). Cut any cable tie-wraps being careful not to cut or nick the DC-input wires. 4-60 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Chapter 4 Removal and Replacement Procedures Removing and Installing the DC-Input Power Supplies Note Step 5 Step 6 The 6000 W DC-input power supply provides voltages of 2800 W, 4500 W, or 6000 W for single and redundant configurations. Some configurations require cable tie-wraps, depending on available DC input pairs. Disconnect the DC-input wires from the terminal block in this order: • Positive (+) • Negative (-) Disconnect the DC power supply ground. Warning When installing the unit, always make the ground connection first and disconnect it last. Statement 42 Figure 4-42 DC-Input Wire Connections for 6000-W DC-Input Power Supply (2800W DC-input shown) Terminal block cover Input power module Power leads attached to terminal block ( - ) Negative (+) Positive ( - ) Negative (+) Positive RUN INSTALL Power switch CISCO SYSTEMS, INC 1 2 3 4 INPUT OK 191287 FAN OK OUTPUT FAIL Captive installation screw ( ) Ground OL-5781-08 Catalyst 6500 Series Switches Installation Guide 4-61
- Page 216 and 217: Removing and Installing the AC-Inpu
- Page 218 and 219: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 220 and 221: Removing and Installing the AC-Inpu
- Page 222 and 223: OSM-4OC12 POS-SI 1 2 1 2 1 1 2 2 3
- Page 224 and 225: Removing and Installing the DC-Inpu
- Page 226 and 227: Removing and Installing the DC-Inpu
- Page 228 and 229: Removing and Installing the DC-Inpu
- Page 230 and 231: Removing and Installing the DC-Inpu
- Page 232 and 233: Removing and Installing the DC-Inpu
- Page 234 and 235: Removing and Installing the DC-Inpu
- Page 236 and 237: Removing and Installing the DC-Inpu
- Page 238 and 239: Removing and Installing the DC-Inpu
- Page 240 and 241: Removing and Installing the DC-Inpu
- Page 242 and 243: Removing and Installing the DC-Inpu
- Page 244 and 245: Removing and Installing the DC-Inpu
- Page 246 and 247: Removing and Installing the DC-Inpu
- Page 248 and 249: Removing and Installing the DC-Inpu
- Page 250 and 251: Removing and Installing the DC-Inpu
- Page 252 and 253: Removing and Installing the DC-Inpu
- Page 254 and 255: Removing and Installing the DC-Inpu
- Page 256 and 257: Removing and Installing the DC-Inpu
- Page 258 and 259: Removing and Installing the DC-Inpu
- Page 260 and 261: Removing and Installing the DC-Inpu
- Page 262 and 263: Removing and Installing the DC-Inpu
- Page 264 and 265: Removing and Installing the DC-Inpu
- Page 268 and 269: CISCO SYSTEMS, INC 1 2 3 4 INPUT OK
- Page 270 and 271: Removing and Installing the DC-Inpu
- Page 272 and 273: CISCO SYSTEMS, INC Removing and Ins
- Page 274 and 275: Removing and Installing the DC-Inpu
- Page 276 and 277: Removing and Installing the DC-Inpu
- Page 278 and 279: Removing and Installing the DC-Inpu
- Page 280 and 281: CISCO SYSTEMS, INC 1 2 3 4 INPUT OK
- Page 282 and 283: Removing and Installing PEMs Chapte
- Page 284 and 285: Removing and Installing PEMs Chapte
- Page 286 and 287: OSM-4OC12 POS-SI 1 2 1 2 1 1 2 2 3
- Page 288 and 289: Removing and Installing the Fan Tra
- Page 290 and 291: WS-X6K-SUP2-2GE OSM-4OC12 POS-SI OS
- Page 292 and 293: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 294 and 295: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 296 and 297: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 298 and 299: Removing and Installing the Fan Tra
- Page 300 and 301: ACTIVE TX RX RX TX ACTIVE TX RX RX
- Page 302 and 303: Installing the Air Filter Assembly
- Page 304 and 305: Installing the Remote Power Cycling
- Page 306 and 307: Installing the Remote Power Cycling
- Page 308 and 309: Installing the Remote Power Cycling
- Page 310 and 311: Power Supply Compatibility Matrix A
- Page 312 and 313: Power Supply Compatibility Matrix A
- Page 314 and 315: 950 W AC-Input and DC-Input Power S
Chapter 4<br />
Removal and Replacement Procedures<br />
Removing and Installing the DC-Input Power Supplies<br />
Note<br />
Step 5<br />
Step 6<br />
The 6000 W DC-input power supply provides voltages of 2800 W, 4500 W, or 6000 W for single and<br />
redundant configurations. Some configurations require cable tie-wraps, depending on available DC input<br />
pairs.<br />
Disconnect the DC-input wires from the terminal block in this order:<br />
• Positive (+)<br />
• Negative (-)<br />
Disconnect the DC power supply ground.<br />
Warning When installing the unit, always make the ground connection first and disconnect it last. Statement 42<br />
Figure 4-42<br />
DC-Input Wire Connections for 6000-W DC-Input Power Supply (2800W DC-input<br />
shown)<br />
Terminal<br />
block cover<br />
Input power<br />
module<br />
Power leads<br />
attached to<br />
terminal block<br />
( - ) Negative<br />
(+) Positive<br />
( - ) Negative<br />
(+) Positive<br />
RUN<br />
INSTALL<br />
Power<br />
switch<br />
CISCO SYSTEMS, INC<br />
1 2 3 4<br />
INPUT OK<br />
191287<br />
FAN<br />
OK<br />
OUTPUT<br />
FAIL<br />
Captive<br />
installation<br />
screw<br />
( ) Ground<br />
OL-5781-08<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
4-61