CISCO SYSTEMS, INC<br />

Removing and Installing the DC-Input Power Supplies<br />

Chapter 4<br />

Removal and Replacement Procedures<br />

Figure 4-41<br />

DC-Input Front Panel for 6000-W DC-Input Power Supply<br />

1<br />

7<br />

2<br />

3<br />

8<br />

8<br />

9 9<br />

RUN<br />

INSTALL<br />

191286<br />

5<br />

1 2 3 4<br />

INPUT OK<br />

FAN<br />

OK<br />

OUTPUT<br />

FAIL<br />

6<br />

4<br />

1 Terminal block cover 6 Captive installation screw<br />

2 DC power cable terminal block 7 Input Power Module (IPM)<br />

3 Ground 8 IPM captive screws<br />

4 Status LEDs 9 IPM latches<br />

5 Power switch<br />

Note<br />

Step 3<br />

Step 4<br />

With the PWR-6000-DC power supply, you have the option of removing the Input Power Module (IPM)<br />

without disconnecting the DC-input wires and the ground wires. You can then replace your power supply<br />

and insert the fully-wired IPM. To use this option, do not perform steps 3 through 6 and go to step 7.<br />

Remove the two A4 screws securing the terminal block cover, and remove the cover from the power<br />

supply (Figure 4-42).<br />

Cut any cable tie-wraps being careful not to cut or nick the DC-input wires.<br />