Chapter 4<br />

Removal and Replacement Procedures<br />

Removing and Installing the DC-Input Power Supplies<br />

Required Tools<br />

The following tools are required for the power supply removal and installation procedures:<br />

• Number 2 Phillips-head screwdriver<br />

• 1/4-inch open-ended wrench or 1/4-inch nutdriver<br />

• Wire cutters to cut the cable tie-wraps<br />

Additional tools might be necessary to install the lugs on the source DC and the ground cables.<br />

Additionally, the lugs for the source DC cables and the ground cable are not provided; you must obtain<br />

them on your own.<br />

Removing a 6000 W DC-Input Power Supply<br />

Warning<br />

Before performing any of the following procedures, ensure that power is removed from the DC<br />

circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power<br />

lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC<br />

power line fuses. Statement 322<br />

Warning<br />

Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,<br />

keep hands and fingers out of the power supply bays and backplane areas. Statement 166<br />

Note<br />

With the 6000 W DC-input power supply, you have the option of removing the Input Power Module<br />

(IPM) without disconnecting the DC-input wires and the ground wires. You can then replace your power<br />

supply and insert the fully-wired IPM. Read through this procedure carefully before removing your<br />

power supply.<br />

To remove a DC-input power supply, follow these steps:<br />

Step 1<br />

Verify that power is off to the DC circuit connected to the DC-input power supply you are removing. As<br />

an added precaution, place the appropriate safety flag and lockout devices at the source DC power circuit<br />

breaker, or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power<br />

restoration while you are working on the circuit.<br />

Step 2 Turn the power switch to the Off (0) position on the power supply you are removing (Figure 4-41).<br />

Turning the power switch off also disengages a pawl that unlocks the power supply from the chassis.<br />