Chapter 4<br />

Removal and Replacement Procedures<br />

Removing and Installing the AC-Input Power Supplies<br />

Installing the 1000 W, 1300 W, 2500 W, 3000 W, 4000 W, 6000 W, and 8700 W AC-Input Power<br />

Supplies<br />

Caution<br />

Use both hands to install and remove power supplies. Each <strong>Catalyst</strong> <strong>6500</strong> series AC-input power supply<br />

weighs between 14.5 pounds (6.6 kg) and 40 pounds (18.14 kg).<br />

To install an AC-input power supply, follow these steps:<br />

Step 1<br />

Ensure that the system (earth) ground connection has been made. For ground connection instructions,<br />

see the “Establishing the System Ground” section on page 3-52.<br />

Note<br />

If you are installing an 8700 W power supply in a <strong>Catalyst</strong> 6506, <strong>Catalyst</strong> 6509, or<br />

<strong>Catalyst</strong> 6509-NEB chassis, you must install the system (NEBS) ground lug on the system<br />

ground studs on the power supply faceplate rather than the system ground pad on the chassis.<br />

The increased depth of the 8700 W power supply covers the system (NEBS) ground pad on these<br />

three chassis. To install the system ground on the 8700 W power supply, see “Installing the<br />

System Ground on an 8700 W Power Supply” section on page 3-59.<br />

Step 2<br />

Step 3<br />

Step 4<br />

Step 5<br />

If necessary, remove the blank faceplate (Cisco part number 800-27924-xx) from the chassis power<br />

supply bay opening by loosening the captive installation screw.<br />

Remove the power supply from its shipping packaging.<br />

Verify that the power switch is in the off (0) position on the power supply that you are installing.<br />

(See Figure 4-6.)<br />

Grasp the power supply handle with one hand. Place your other hand underneath the power supply, as<br />

shown in Figure 4-7. Slide the power supply into the power supply bay. Make sure that the power supply<br />

is fully seated in the bay.<br />

Step 6 Tighten the power supply captive installation screw. (See Figure 4-6.)<br />

Step 7<br />

Step 8<br />

If you are installing an 8700 W power supply in a <strong>Catalyst</strong> 6506, <strong>Catalyst</strong> 6509, or <strong>Catalyst</strong> 6509-NEB<br />

chassis, install the system (NEBS) ground lug on the power supply system ground studs. For installation<br />

instructions, see “Installing the System Ground on an 8700 W Power Supply” section on page 3-59<br />

Plug the power cord into the power supply, and tighten the screw on the cable retention device. Refer to<br />

Appendix A for a list of supported AC power cords for your particular AC-input power supply.<br />

Note<br />

The AC power cords for the 4000 W power supply are hard wired to the power supply.<br />

OL-5781-08<br />

<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />

4-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!