Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Chapter 3 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis This section provides procedures for installing either a Catalyst 6503 or a Catalyst 6503-E switch chassis in a rack assembly and installing the optional cable guide assemblies. Installation Accessory Kit The Catalyst 6503 and Catalyst 6503-E switch chassis are both designed to be installed in a standard 19-inch rack, either open or enclosed, using 19-inch rack-mount brackets that are factory installed on the left-front and right-front of the chassis. Included in the installation accessory kit are both 10-32 x 0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack. Note Depending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24 screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit and must be obtained on your own. Also included in the accessory kit are two optional cable guides. The two cable guides are installed on the front left- and right-sides of the chassis using the same sets of screws (either 10-32 or 12-24) that secure the chassis rack-mount brackets to the rack posts. Rack-Mount Brackets on the Catalyst 6503 and the Catalyst 6503-E Switch Chassis The Catalyst 6503 and the Catalyst 6503-E switch chassis are shipped with the two rack-mount brackets factory-installed on the front sides of the chassis. The rack-mount brackets are secured to the chassis with eight M3 Phillips-head countersunk screws (four screws on each side) as shown in Figure 3-1. Note The Catalyst 6503-E chassis has a chassis shipping bracket installed across the module slots. The bracket has been removed for clarity in Figure 3-1. The Catalyst 6503 switch chassis does not have this shipping bracket. Note The rack-mount brackets can also be reversed and installed on the rear of the chassis as an alternative method of installation. 3-8 Catalyst 6500 Series Switches Installation Guide OL-5781-08
WS-X6K-SUP2-2GE SUPERVISOR2 OSM-4OC12 POS-SI 1 2 1 2 1 1 CONSOLE 2 2 CONSOLE PORT MODE 3 4 3 4 3 3 4 4 PCMCIA EJECT 1% Chapter 3 Installing the Switch Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis Figure 3-1 Rack-Mount Brackets on the Catalyst 6503 and the Catalyst 6503-E Switch Chassis STATUS SYSTEM CONSOLE PWR MGMT RESET Switch Load 100% PORT 1 PORT 2 OSM-4OC12 POS-SI STATUS 4 PORT OC-12 POS SM IR LINK LINK LINK LINK RESET CARRIER ALARM ACTIVE TX RX PORT 1 RX TX CARRIER ALARM ACTIVE TX RX PORT 2 RX TX CARRIER ALARM ACTIVE TX RX PORT 3 RX TX CARRIER ALARM ACTIVE LINK TX RX PORT4 RX TX LINK 63180 STATUS 4 PORT OC-12 POS SM IR LINK LINK LINK LINK RESET CARRIER ALARM ACTIVE TX RX PORT 1 RX TX CARRIER ALARM ACTIVE TX RX PORT 2 RX TX CARRIER ALARM ACTIVE TX RX PORT 3 RX TX CARRIER ALARM ACTIVE TX RX PORT4 RX TX Rack-Mounting the Chassis Note The chassis are designed to be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. Warning Two people are required to lift the chassis. To prevent injury, keep your back straight and lift with your legs, not your back. Statement 164 Tip We recommend that you have a third person to assist in this procedure. To install the switch chassis into the equipment rack, follow these steps: Step 1 Determine the positioning of the chassis in the rack enclosure. Identify the rack post holes that will be used. If the rack post holes are prethreaded, determine if the threads are 10-32 or 12-24. If the rack post holes are unthreaded, install either 10-32 or 12-24 clip or cage nuts over the holes to accept the installation screws. Note Clip or cage nuts are not included as part of the accessory kit that comes with the chassis. You must obtain them yourself. Step 2 If you are installing a Catalyst 6503-E switch chassis, you must remove the chassis shipping bracket before you install the chassis in the rack. Perform the following substeps: a. Loosen and remove the four M5 screws that secure the chassis shipping bracket to the chassis rack mount brackets. (See Figure 3-2.) b. Lift up slightly on the shipping bracket to disengage the two bracket hooks from the rack-mount brackets. c. Remove the shipping bracket and save it. You must reinstall the shipping bracket if you relocate the chassis. OL-5781-08 Catalyst 6500 Series Switches Installation Guide 3-9
- Page 78 and 79: Catalyst 6509-V-E Switch Chapter 1
- Page 80 and 81: Catalyst 6509-V-E Switch Chapter 1
- Page 82 and 83: Catalyst 6513 Switch Chapter 1 Prod
- Page 84 and 85: Catalyst 6513 Switch Chapter 1 Prod
- Page 86 and 87: Catalyst 6513 Switch Chapter 1 Prod
- Page 88 and 89: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 90 and 91: Catalyst 6513-E Switch Chapter 1 Pr
- Page 92 and 93: Catalyst 6513-E Switch Chapter 1 Pr
- Page 94 and 95: Catalyst 6513-E Switch Chapter 1 Pr
- Page 96 and 97: Safety Chapter 2 Preparing for Inst
- Page 98 and 99: Site Requirements Chapter 2 Prepari
- Page 100 and 101: WS-X6K-SUP2-2GE OSM-4OC12 POS-SI 4
- Page 102 and 103: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 104 and 105: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 106 and 107: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 108 and 109: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 110 and 111: Site Requirements Chapter 2 Prepari
- Page 112 and 113: Site Requirements Chapter 2 Prepari
- Page 114 and 115: Site Requirements Chapter 2 Prepari
- Page 116 and 117: Power Requirements Chapter 2 Prepar
- Page 118 and 119: Cabling Requirements Chapter 2 Prep
- Page 120 and 121: Site Preparation Checklist Chapter
- Page 122 and 123: Chapter 3 Installing the Switch The
- Page 124 and 125: Rack-Mounting Guidelines Chapter 3
- Page 126 and 127: Chassis Installation Kits and Cable
- Page 130 and 131: CAUTION STATUS LINK CONSOLE LINK LI
- Page 132 and 133: Installing a Catalyst 6504-E Switch
- Page 134 and 135: WS-SUP32-GE-3B CAUTION STATUS LINK
- Page 136 and 137: Installing a Catalyst 6504-E Switch
- Page 138 and 139: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 140 and 141: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 142 and 143: WS-X6408 WS-X6408 WS-X6224 24 PORT
- Page 144 and 145: WS-X6408 WS-X6408 WS-X6224 24 PORT
- Page 146 and 147: Installing a Catalyst 6509-NEB or C
- Page 148 and 149: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 150 and 151: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 152 and 153: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 154 and 155: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 156 and 157: Installing a Catalyst 6509-V-E Swit
- Page 158 and 159: Installing a Catalyst 6509-V-E Swit
- Page 160 and 161: Installing a Catalyst 6509-V-E Swit
- Page 162 and 163: Installing a Catalyst 6513 or Catal
- Page 164 and 165: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 166 and 167: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 168 and 169: Generic Installation Procedures Cha
- Page 170 and 171: Generic Installation Procedures Cha
- Page 172 and 173: Establishing the System Ground Chap
- Page 174 and 175: OSM-4OC12 POS-SI 2 1 2 1 4 2 3 1 4
- Page 176 and 177: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
Installing a <strong>Catalyst</strong> 6503 or <strong>Catalyst</strong> 6503-E Switch Chassis<br />
Chapter 3<br />
Installing the Switch<br />
Installing a <strong>Catalyst</strong> 6503 or <strong>Catalyst</strong> 6503-E Switch Chassis<br />
This section provides procedures for installing either a <strong>Catalyst</strong> 6503 or a <strong>Catalyst</strong> 6503-E switch<br />
chassis in a rack assembly and installing the optional cable guide assemblies.<br />
<strong>Installation</strong> Accessory Kit<br />
The <strong>Catalyst</strong> 6503 and <strong>Catalyst</strong> 6503-E switch chassis are both designed to be installed in a standard<br />
19-inch rack, either open or enclosed, using 19-inch rack-mount brackets that are factory installed on<br />
the left-front and right-front of the chassis. Included in the installation accessory kit are both 10-32 x<br />
0.75-inch and 12-24 x 0.75-inch screws that are used to secure the chassis in the rack.<br />
Note Depending on the manufacturer, the rack posts might be prethreaded to accept either 10-32 or 12-24<br />
screws. If the rack posts are not prethreaded, you must install 10-32 or 12-24 clip nuts or cage nuts to<br />
secure the rack-mount screws. The clip nuts or the cage nuts are not included as part of the accessory kit<br />
and must be obtained on your own.<br />
Also included in the accessory kit are two optional cable guides. The two cable guides are installed on<br />
the front left- and right-sides of the chassis using the same sets of screws (either 10-32 or 12-24) that<br />
secure the chassis rack-mount brackets to the rack posts.<br />
Rack-Mount Brackets on the <strong>Catalyst</strong> 6503 and the <strong>Catalyst</strong> 6503-E Switch<br />
Chassis<br />
The <strong>Catalyst</strong> 6503 and the <strong>Catalyst</strong> 6503-E switch chassis are shipped with the two rack-mount brackets<br />
factory-installed on the front sides of the chassis. The rack-mount brackets are secured to the chassis<br />
with eight M3 Phillips-head countersunk screws (four screws on each side) as shown in Figure 3-1.<br />
Note<br />
The <strong>Catalyst</strong> 6503-E chassis has a chassis shipping bracket installed across the module slots. The bracket<br />
has been removed for clarity in Figure 3-1. The <strong>Catalyst</strong> 6503 switch chassis does not have this shipping<br />
bracket.<br />
Note<br />
The rack-mount brackets can also be reversed and installed on the rear of the chassis as an alternative<br />
method of installation.<br />
3-8<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
OL-5781-08