Chapter 3 Installing the Switch The chapter contains the following sections: • Rack-Mounting Guidelines, page 3-3 • Unpacking the Switch, page 3-5 • Chassis Installation Kits and Cable Guides, page 3-5 • Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis, page 3-8 • Installing a Catalyst 6504-E Switch Chassis, page 3-12 • Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis, page 3-17 • Installing a Catalyst 6509 or Catalyst 6509-E Switch Chassis, page 3-21 • Installing a Catalyst 6509-NEB or Catalyst 6509-NEB-A Switch Chassis, page 3-26 • Installing a Catalyst 6509-V-E Switch Chassis, page 3-36 • Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis, page 3-42 • Generic Installation Procedures, page 3-47 • Establishing the System Ground, page 3-52 • Installing the Power Supplies in the Switch Chassis, page 3-61 • Attaching the Interface Cables, page 3-61 • Verifying Switch Chassis Installation, page 3-84 Warning Class 1 laser product. Statement 1008 Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017 Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2) while the housing is open, or both. Statement 1043 3-2 Catalyst 6500 Series Switches Installation Guide OL-5781-08
Chapter 3 Installing the Switch Rack-Mounting Guidelines Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045 Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Note If you are installing a freestanding (not rack-mounted) Catalyst 6509-NEB, Catalyst 6513, or Catalyst 6513-E switch, you must install the stabilizer bracket kit, which is included as part of the accessory kit for these two switch chassis. Before starting the installation procedures in this chapter, see the “Site Preparation Checklist” section on page 2-24 to verify that all site planning activities were completed. Rack-Mounting Guidelines The Catalyst 6500 series switches are designed to be installed in both open and enclosed racks. Before rack-mounting the switch, ensure that the equipment rack complies with the following guidelines: • The width of the rack, measured between the two front-mounting strips or rails, must be 17.75 inches (45.09 cm). • The depth of the rack, measured between the front- and rear-mounting strips, must be at least 19.25 inches (48.9 cm). Note All of the Catalyst 6500 series switch chassis are designed to install in standard 19-inch racks. • The rack must have sufficient vertical clearance to insert the chassis. The chassis heights are as follows: – Catalyst 6503 switch—7 inches (17.8 cm) (4 RU) – Catalyst 6503-E switch—7 inches (17.8 cm) (4 RU) – Catalyst 6504-E switch—8.7 inches (22.1 cm) (5 RU) – Catalyst 6506 switch—20.1 inches (51.1 cm) (12 RU) – Catalyst 6506-E switch—20.1 inches (51.1 cm) (12 RU) – Catalyst 6509 switch—25.2 inches (64.0 cm) (15 RU) – Catalyst 6509-E switch—25.2 inches (64.0 cm) (15 RU) – Catalyst 6509-NEB switch—33.3 inches (84.6 cm) (20 RU) – Catalyst 6509-NEB-A switch—36.65 inches (93.1 cm) (21 RU) – Catalyst 6509-V-E switch—36.65 inches (93.1 cm) (21 RU) – Catalyst 6513 switch—33.3 inches (84.6 cm) (20 RU) – Catalyst 6513-E switch—33.3 inches (84.6 cm) (20 RU) OL-5781-08 Catalyst 6500 Series Switches Installation Guide 3-3
- Page 72 and 73: Catalyst 6509-NEB-A Switch Chapter
- Page 74 and 75: Catalyst 6509-NEB-A Switch Chapter
- Page 76 and 77: Catalyst 6509-V-E Switch Chapter 1
- Page 78 and 79: Catalyst 6509-V-E Switch Chapter 1
- Page 80 and 81: Catalyst 6509-V-E Switch Chapter 1
- Page 82 and 83: Catalyst 6513 Switch Chapter 1 Prod
- Page 84 and 85: Catalyst 6513 Switch Chapter 1 Prod
- Page 86 and 87: Catalyst 6513 Switch Chapter 1 Prod
- Page 88 and 89: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 90 and 91: Catalyst 6513-E Switch Chapter 1 Pr
- Page 92 and 93: Catalyst 6513-E Switch Chapter 1 Pr
- Page 94 and 95: Catalyst 6513-E Switch Chapter 1 Pr
- Page 96 and 97: Safety Chapter 2 Preparing for Inst
- Page 98 and 99: Site Requirements Chapter 2 Prepari
- Page 100 and 101: WS-X6K-SUP2-2GE OSM-4OC12 POS-SI 4
- Page 102 and 103: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 104 and 105: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 106 and 107: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 108 and 109: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 110 and 111: Site Requirements Chapter 2 Prepari
- Page 112 and 113: Site Requirements Chapter 2 Prepari
- Page 114 and 115: Site Requirements Chapter 2 Prepari
- Page 116 and 117: Power Requirements Chapter 2 Prepar
- Page 118 and 119: Cabling Requirements Chapter 2 Prep
- Page 120 and 121: Site Preparation Checklist Chapter
- Page 124 and 125: Rack-Mounting Guidelines Chapter 3
- Page 126 and 127: Chassis Installation Kits and Cable
- Page 128 and 129: Installing a Catalyst 6503 or Catal
- Page 130 and 131: CAUTION STATUS LINK CONSOLE LINK LI
- Page 132 and 133: Installing a Catalyst 6504-E Switch
- Page 134 and 135: WS-SUP32-GE-3B CAUTION STATUS LINK
- Page 136 and 137: Installing a Catalyst 6504-E Switch
- Page 138 and 139: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 140 and 141: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 142 and 143: WS-X6408 WS-X6408 WS-X6224 24 PORT
- Page 144 and 145: WS-X6408 WS-X6408 WS-X6224 24 PORT
- Page 146 and 147: Installing a Catalyst 6509-NEB or C
- Page 148 and 149: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 150 and 151: 1 2 3 4 5 6 7 8 9 10 1 1 2 12 3 4 5
- Page 152 and 153: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 154 and 155: WS-C6500-SFM SWITCH FABRIC MDL WS-C
- Page 156 and 157: Installing a Catalyst 6509-V-E Swit
- Page 158 and 159: Installing a Catalyst 6509-V-E Swit
- Page 160 and 161: Installing a Catalyst 6509-V-E Swit
- Page 162 and 163: Installing a Catalyst 6513 or Catal
- Page 164 and 165: WS-X6408 8 PORT GIGABIT ETHERNET WS
- Page 166 and 167: WS-X6K-SUP2-2GE SUPERVISOR2 WS-X6K-
- Page 168 and 169: Generic Installation Procedures Cha
- Page 170 and 171: Generic Installation Procedures Cha
Chapter 3<br />
Installing the Switch<br />
The chapter contains the following sections:<br />
• Rack-Mounting <strong>Guide</strong>lines, page 3-3<br />
• Unpacking the Switch, page 3-5<br />
• Chassis <strong>Installation</strong> Kits and Cable <strong>Guide</strong>s, page 3-5<br />
• Installing a <strong>Catalyst</strong> 6503 or <strong>Catalyst</strong> 6503-E Switch Chassis, page 3-8<br />
• Installing a <strong>Catalyst</strong> 6504-E Switch Chassis, page 3-12<br />
• Installing a <strong>Catalyst</strong> 6506 or <strong>Catalyst</strong> 6506-E Switch Chassis, page 3-17<br />
• Installing a <strong>Catalyst</strong> 6509 or <strong>Catalyst</strong> 6509-E Switch Chassis, page 3-21<br />
• Installing a <strong>Catalyst</strong> 6509-NEB or <strong>Catalyst</strong> 6509-NEB-A Switch Chassis, page 3-26<br />
• Installing a <strong>Catalyst</strong> 6509-V-E Switch Chassis, page 3-36<br />
• Installing a <strong>Catalyst</strong> 6513 or <strong>Catalyst</strong> 6513-E Switch Chassis, page 3-42<br />
• Generic <strong>Installation</strong> Procedures, page 3-47<br />
• Establishing the System Ground, page 3-52<br />
• Installing the Power Supplies in the Switch Chassis, page 3-61<br />
• Attaching the Interface Cables, page 3-61<br />
• Verifying Switch Chassis <strong>Installation</strong>, page 3-84<br />
Warning Class 1 laser product. Statement 1008<br />
Warning<br />
This unit is intended for installation in restricted access areas. A restricted access area can be<br />
accessed only through the use of a special tool, lock and key, or other means of security.<br />
Statement 1017<br />
Warning<br />
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.<br />
Statement 1030<br />
Warning<br />
Ultimate disposal of this product should be handled according to all national laws and regulations.<br />
Statement 1040<br />
Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260.<br />
Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The<br />
telecommunications lines must be disconnected 1) before unplugging the main power connector or 2)<br />
while the housing is open, or both. Statement 1043<br />
3-2<br />
<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />
OL-5781-08