Chapter 3 Installing the Switch The chapter contains the following sections: • Rack-Mounting Guidelines, page 3-3 • Unpacking the Switch, page 3-5 • Chassis Installation Kits and Cable Guides, page 3-5 • Installing a Catalyst 6503 or Catalyst 6503-E Switch Chassis, page 3-8 • Installing a Catalyst 6504-E Switch Chassis, page 3-12 • Installing a Catalyst 6506 or Catalyst 6506-E Switch Chassis, page 3-17 • Installing a Catalyst 6509 or Catalyst 6509-E Switch Chassis, page 3-21 • Installing a Catalyst 6509-NEB or Catalyst 6509-NEB-A Switch Chassis, page 3-26 • Installing a Catalyst 6509-V-E Switch Chassis, page 3-36 • Installing a Catalyst 6513 or Catalyst 6513-E Switch Chassis, page 3-42 • Generic Installation Procedures, page 3-47 • Establishing the System Ground, page 3-52 • Installing the Power Supplies in the Switch Chassis, page 3-61 • Attaching the Interface Cables, page 3-61 • Verifying Switch Chassis Installation, page 3-84 Warning Class 1 laser product. Statement 1008 Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017 Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2) while the housing is open, or both. Statement 1043 3-2 Catalyst 6500 Series Switches Installation Guide OL-5781-08

Chapter 3 Installing the Switch Rack-Mounting Guidelines Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045 Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Note If you are installing a freestanding (not rack-mounted) Catalyst 6509-NEB, Catalyst 6513, or Catalyst 6513-E switch, you must install the stabilizer bracket kit, which is included as part of the accessory kit for these two switch chassis. Before starting the installation procedures in this chapter, see the “Site Preparation Checklist” section on page 2-24 to verify that all site planning activities were completed. Rack-Mounting Guidelines The Catalyst 6500 series switches are designed to be installed in both open and enclosed racks. Before rack-mounting the switch, ensure that the equipment rack complies with the following guidelines: • The width of the rack, measured between the two front-mounting strips or rails, must be 17.75 inches (45.09 cm). • The depth of the rack, measured between the front- and rear-mounting strips, must be at least 19.25 inches (48.9 cm). Note All of the Catalyst 6500 series switch chassis are designed to install in standard 19-inch racks. • The rack must have sufficient vertical clearance to insert the chassis. The chassis heights are as follows: – Catalyst 6503 switch—7 inches (17.8 cm) (4 RU) – Catalyst 6503-E switch—7 inches (17.8 cm) (4 RU) – Catalyst 6504-E switch—8.7 inches (22.1 cm) (5 RU) – Catalyst 6506 switch—20.1 inches (51.1 cm) (12 RU) – Catalyst 6506-E switch—20.1 inches (51.1 cm) (12 RU) – Catalyst 6509 switch—25.2 inches (64.0 cm) (15 RU) – Catalyst 6509-E switch—25.2 inches (64.0 cm) (15 RU) – Catalyst 6509-NEB switch—33.3 inches (84.6 cm) (20 RU) – Catalyst 6509-NEB-A switch—36.65 inches (93.1 cm) (21 RU) – Catalyst 6509-V-E switch—36.65 inches (93.1 cm) (21 RU) – Catalyst 6513 switch—33.3 inches (84.6 cm) (20 RU) – Catalyst 6513-E switch—33.3 inches (84.6 cm) (20 RU) OL-5781-08 Catalyst 6500 Series Switches Installation Guide 3-3

Chapter 3<br />

Installing the Switch<br />

The chapter contains the following sections:<br />

• Rack-Mounting <strong>Guide</strong>lines, page 3-3<br />

• Unpacking the Switch, page 3-5<br />

• Chassis <strong>Installation</strong> Kits and Cable <strong>Guide</strong>s, page 3-5<br />

• Installing a <strong>Catalyst</strong> 6503 or <strong>Catalyst</strong> 6503-E Switch Chassis, page 3-8<br />

• Installing a <strong>Catalyst</strong> 6504-E Switch Chassis, page 3-12<br />

• Installing a <strong>Catalyst</strong> 6506 or <strong>Catalyst</strong> 6506-E Switch Chassis, page 3-17<br />

• Installing a <strong>Catalyst</strong> 6509 or <strong>Catalyst</strong> 6509-E Switch Chassis, page 3-21<br />

• Installing a <strong>Catalyst</strong> 6509-NEB or <strong>Catalyst</strong> 6509-NEB-A Switch Chassis, page 3-26<br />

• Installing a <strong>Catalyst</strong> 6509-V-E Switch Chassis, page 3-36<br />

• Installing a <strong>Catalyst</strong> 6513 or <strong>Catalyst</strong> 6513-E Switch Chassis, page 3-42<br />

• Generic <strong>Installation</strong> Procedures, page 3-47<br />

• Establishing the System Ground, page 3-52<br />

• Installing the Power Supplies in the Switch Chassis, page 3-61<br />

• Attaching the Interface Cables, page 3-61<br />

• Verifying Switch Chassis <strong>Installation</strong>, page 3-84<br />

Warning Class 1 laser product. Statement 1008<br />

Warning<br />

This unit is intended for installation in restricted access areas. A restricted access area can be<br />

accessed only through the use of a special tool, lock and key, or other means of security.<br />

Statement 1017<br />

Warning<br />

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.<br />

Statement 1030<br />

Warning<br />

Ultimate disposal of this product should be handled according to all national laws and regulations.<br />

Statement 1040<br />

Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260.<br />

Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The<br />

telecommunications lines must be disconnected 1) before unplugging the main power connector or 2)<br />

while the housing is open, or both. Statement 1043<br />

3-2<br />

<strong>Catalyst</strong> <strong>6500</strong> <strong>Series</strong> <strong>Switches</strong> <strong>Installation</strong> <strong>Guide</strong><br />

OL-5781-08