TROUBLESHOOTING CHAPTER 5<br />

Connections: Asynchronous<br />

No response from host on the PC screen<br />

If <strong>SkyLite</strong> displays no output on the screen, it is likely that this is because either the<br />

hardware link to the host is inoperable or there is some incompatibility between the line<br />

characteristics <strong>of</strong> the host system and the PC.<br />

If you can:<br />

• Check the host connection by replacing the PC with a terminal. If the terminal<br />

operates satisfactorily, use it to determine the host port parameters such as baud<br />

rate using the appropriate host command. Compare these settings with the<br />

<strong>SkyLite</strong> session parameters.<br />

• Check the cable connections between the PC and the host system carefully.<br />

Ensure that the correct connector is being used on the rear <strong>of</strong> the PC and that the<br />

PC port selected in the currently active session (COM1 to COM8 or network) is<br />

the port being physically used. Check also that the connector is not plugged into<br />

the parallel port.<br />

• You can use a loopback connector in the communications port to test that keys<br />

pressed appear correctly on the screen. A loopback connector is a simple tool that<br />

joins pin2 to pin3.<br />

• Check that the host is not hung on an X<strong>of</strong>f character. To overcome this, press<br />

Ctrl and Q on your keyboard.<br />

• Press Return, Break, or the space bar a couple <strong>of</strong> times to activate the host.<br />

• Check that the host port is not in debug mode. Then enter “OFF” at the keyboard<br />

to close down the session.<br />

• Check that you have not selected the serial mouse port as your communications<br />

port.<br />

• Check that your communications port is set up with the correct IRQ and port<br />

I/O address. Refer to your port reference guide or PC manual for further<br />

information.<br />

• Check that if you have used other manufacturer’s s<strong>of</strong>tware, which uses the port,<br />

that it is not left in an anomalous state. Reboot the PC to reset the port.<br />

Garbled or no response from host<br />

This is usually caused by incompatibilities in port settings between the PC and the host<br />

system.<br />

Check that the terminal type is defined correctly for your application and that it is<br />

identical to that defined on the host port.<br />

Check the settings <strong>of</strong> the host port (from a working terminal) using the appropriate host<br />

command. Compare these with the settings on the PC in <strong>SkyLite</strong>’s menu. The most likely<br />

candidates for mismatch are the baud rate or parity settings for asynchronous<br />

communications.<br />

Character corruption appears on screen<br />

If letters are missing from words on the screen or spurious characters (such as cursor<br />

positioning sequences that might look like "[23;1", etc.) appear on the screen, you should<br />

make the following checks.<br />

If using asynchronous communications, check that flow control is ON for both <strong>SkyLite</strong><br />

and the host port.<br />

If the problem persists and you are running at a baud rate that is too high (say 19,200<br />

bps), try resetting this to a lower baud rate, say 9600 bps. It is possible that your host<br />

system does not correctly support flow control at higher baud rates.<br />

62 <strong>POISE</strong>-<strong>SkyLite</strong> <strong>User</strong> <strong>Guide</strong>