4. Equip the person working on the batten strips inside with an air impact<br />

gun and apron full of 1 /4" x 11 /16" buck rivets. Prior to installing the battens,<br />

make an alignment reference mark on the interior extrusion just above<br />

where the two lower panels meet.<br />

5. Use the marks to center the strip equally over the vertical seam before<br />

drilling the first hole from outside inward. Prior to drilling holes, both inside<br />

and outside batten strips must be held tightly against the side panel to<br />

prevent shavings from accumulating underneath.<br />

6. The person outside must be prepared to back drill the 1 /4" holes, using an<br />

F bit (.257), and simultaneously place buck rivets, which are to be<br />

installed from inside. Install the first few rivets at the top, middle, and<br />

bottom of the batten sides to hold the strips secure while the remaining<br />

holes are being drilled.<br />

Figure 17, Aligning and Installing Batten Strips Over the Vertical Seams<br />