13.11.2014 Views

O Scale Trains Magazine Online

O Scale Trains Magazine Online

O Scale Trains Magazine Online

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8<br />

together to assemble a single unit. All of these castings were<br />

painted with Polly S Aged White, glazed with microscope cover<br />

slip glass cut with a diamond tip scribe, and installed right after<br />

the exterior sheathing was completed (since later access would<br />

be limited).<br />

The exterior of the boiler house walls were finished off with<br />

board-and-batten siding made from individual HO scale 1” x<br />

24” and 2 x 4 boards that extended down over the side sills<br />

prior to the walls being mounted on the flooring of the boiler<br />

house. An “interior” portion of the East wall, exposed inside of<br />

the slatted exterior trellis wall, was also finished off with this<br />

same board-and-batten sheathing. An HO 8” x 12” was added<br />

to the end of this wall for the header of the trellis part of the slatted<br />

exterior wall to rest on (Photo 8).<br />

Installation of these three walls for the boiler house was done<br />

starting with the North wall. It was first secured to the floor and<br />

to the anchoring 4 x 4 of the main building East wall with CA.<br />

The West wall was then installed, secured to the floor and to<br />

the North boiler house wall, being careful to keep it square and<br />

plumb while running out to the end of that foundation extension.<br />

The South boiler house wall was then slid in between<br />

the East wall of the main building and the previously secured<br />

East wall of the boiler house, and glued in place with CA. The<br />

exposed southern end post of the East wall was doubled on the<br />

interior side of the East wall with scrap wood. This brings the<br />

thickness of this post up to nearly the width of the foundation.<br />

The addition to that post provides the tie-in of the exterior trellis<br />

wall and support beam for the rafters of the boiler house.<br />

Lattice Exterior Wall<br />

The uprights/supports for the lattice/trellis exterior wall were<br />

made from HO 8” x 12” wood, spaced equidistant between<br />

the boiler house East wall and the free end of the lattice wall.<br />

Note that the lattice wall comes adjacent, but actually does not<br />

directly attach to the East wall of the main building. An HO 4’ x<br />

12” beam extends from the end support post of the East boiler<br />

house wall and rests on these supports. This beam then provides<br />

support for the rafters. The lattice or trellis boards were<br />

made from HO 3” x 10” lumber. The east ends of the trellis<br />

boards extend to attach to the HO 8” x 12” end-post of the boiler<br />

house East wall. The joints of these boards were dressed up<br />

with Grandt Line #1 nbw’s. The ceiling, over the area extending<br />

from the South wall to the lattice/trellis header, was closed in<br />

with scrap 1/32” thick Northeastern 3/32” spaced scribed siding<br />

(Photo 9 and Figure 5 on page 46).<br />

Boiler House Rafters<br />

The roof rafters were made from 1/16” x 5/32” dimensional<br />

lumber. They are quite simple, with the two roof rafters resting<br />

on a single center support up from the traversal beam (Figure<br />

6 on Page 46). These were set to match the spacing of the lattice/trellis<br />

supports, then additional rafters were added equidistant<br />

between those. The far western rafter was not attached to<br />

the main building. Instead, the roofing later ties this structure<br />

into the siding of the main building with flashing. I’ll cover the<br />

roofing issues in Part 2. Soffit boards were inserted between<br />

the rafters (1/16” x 3/16” scrap dimensional lumber). A chimney<br />

platform was made from 1/32” scrap, spanning two rafters near<br />

the main building. The chimney was built up on this platform,<br />

well above the rafters and capped with additional Dr. Ben’s<br />

building blocks. Stone steps at each door of the boiler house<br />

were also built from Dr. Ben’s building blocks.<br />

Roofing<br />

The boiler house roof was gap-sheathed with HO 1” x 24”<br />

material for a metal roof. I’ll return to how the entire building<br />

was roofed with metal standing-seam roofing material later, as<br />

all the roof sheathing and finishing was done as a unit.<br />

The First Floor Interior<br />

The interior of the first floor was fitted out at this point, as<br />

later access would be limited. Berkshire Valley supplied the<br />

desk, file cabinets, books, chairs, stove, coal bin, shelving<br />

unit, buckets, and barrels. The interior also features a modified<br />

Grandt Line door between the two buildings, the two cucumber<br />

washing, sorting, and preparation troughs, and the “elevator” to<br />

take barrels upstairs (Photo 10). The large washing basins were<br />

built from sheet copper formed and soldered into shape, then<br />

“wrapped” in 1/32” dimensional lumber with HO 6” x 12” legs<br />

9<br />

10<br />

continued on page 45<br />

July/Aug ’06 - O <strong>Scale</strong> <strong>Trains</strong> • 43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!