HP BladeSystem Family - Critical Facilities Round Table
HP BladeSystem Family - Critical Facilities Round Table HP BladeSystem Family - Critical Facilities Round Table
Dynamic Power Saver 3+3 Power Supply Efficiency Dynamic Power Saver 1+1 up to 2250W 2+2 up to 4500W 3+3 up to 6750W Power Supply Efficiency Typical power supply curve High efficiency maintained from 1150W to 6750 W 2+2 Not Managed 3+3 Not Managed 3+3 Managed Typical PSU 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 Power Supply Output Power (Watts) HP Confidential
ProLiant Power Regulator: advanced power management • Monitor and manage individual and groups of servers by physical or logical location (power domain) • Monitor vital power information − power usage in watts − BTU/hr output − ambient air temperature • Policy based management − Power cap policy: Set maximum BTU’s/hr or wattage threshold (capped on a server by server basis) − Temporary conservation policy: Set time of day to drop lower selected priority servers into lower power state − Severe facilities issue: drop lower priority servers into lower power state when severe facilities issue occurs − Energy efficiency policy: Set all servers in power domain to dynamic power regulating
- Page 1 and 2: The Case for BladeSystem Servers No
- Page 3 and 4: Hardware Density Directions • Tre
- Page 5 and 6: Processors • Today and near futur
- Page 7 and 8: Long Term Server Power Density Cust
- Page 9 and 10: Datacenter Inefficiencies • Unman
- Page 11 and 12: Addressing High Density Zones • D
- Page 13 and 14: Problem: Limited power budget and g
- Page 15 and 16: The HP BladeSystem approach to simp
- Page 17 and 18: c7000 Enclosure Front View Server b
- Page 19 and 20: Processor Naming Decoder - AMD AMD
- Page 21 and 22: The Impact of New Memory Styles •
- Page 23 and 24: Using 32A 3Ø PDU - Intl • S332 -
- Page 25 and 26: Greater efficiency and cost savings
- Page 27: Dynamic Power Saver Operation Switc
- Page 31 and 32: Power Regulator for ProLiant Overvi
- Page 33 and 34: ProLiant Power Management ROM or Op
- Page 35 and 36: c7000 PARSEC Architecture • Hybri
- Page 37 and 38: Fans • Fan Laws − Volume of air
- Page 39 and 40: HP Active Cool Fan • Custom fan d
- Page 41 and 42: Enclosure Management Enclosure infl
- Page 43 and 44: HP Insight Display Local BladeSyste
- Page 45 and 46: Cooling Strategies: How is the mark
- Page 47 and 48: Industry needs to benchmark data ce
- Page 49 and 50: It’s now one conversation Cooling
- Page 51 and 52: Introducing HP Dynamic Smart Coolin
- Page 53 and 54: HP Data Center Solution Builder Pro
- Page 55: Thank you! Ken Baker BladeSystem In
Dynamic Power Saver<br />
3+3 Power Supply Efficiency<br />
Dynamic Power Saver<br />
1+1 up to 2250W 2+2 up to 4500W 3+3 up to 6750W<br />
Power Supply Efficiency<br />
Typical power<br />
supply curve<br />
High efficiency maintained<br />
from 1150W to 6750 W<br />
2+2 Not Managed<br />
3+3 Not Managed<br />
3+3 Managed<br />
Typical PSU<br />
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500<br />
Power Supply Output Power (Watts)<br />
<strong>HP</strong> Confidential