13.11.2014 Views

Samsung | Codes of malfunctions of conditioners | the Insertion of a ...

Samsung | Codes of malfunctions of conditioners | the Insertion of a ...

Samsung | Codes of malfunctions of conditioners | the Insertion of a ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

THE MAIN NEWS CONDITIONERS THE CATALOGUE SITEMAP THE PRICE A PRICE FAQ<br />

Blog | Repair | <strong>Codes</strong> <strong>of</strong> errors | Current article ' <strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a<br />

payment <strong>of</strong> <strong>Samsung</strong>'<br />

>> December, 17th 2011<br />

Search<br />

<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a<br />

payment <strong>of</strong> <strong>Samsung</strong><br />

HEADINGS<br />

Choose a heading a heading<br />

<strong>Samsung</strong> RAC and FJM codes <strong>of</strong> <strong>malfunctions</strong>.<br />

<strong>Samsung</strong>, — еrrors code air conditioning. Many wrongly think that <strong>conditioners</strong> <strong>Samsung</strong> <strong>of</strong>ten break and fail because<br />

<strong>of</strong> quality <strong>of</strong> assemblage and entering details зап.частей <strong>conditioners</strong> <strong>Samsung</strong>.<br />

From a part <strong>the</strong>y will be right, but <strong>Samsung</strong>, — one <strong>of</strong> <strong>the</strong> most sold and national brands <strong>of</strong> <strong>conditioners</strong> with<br />

accessible ценою.<br />

<strong>Samsung</strong> in percentage terms on breakages, — to an exit <strong>of</strong> <strong>conditioners</strong> out <strong>of</strong> operation, practically differs nothing<br />

from <strong>the</strong> colleagues.<br />

Many failures сплит systems <strong>Samsung</strong>, — have constructive character because <strong>of</strong> differences <strong>of</strong><br />

pressure in a network (more than 15 %), and a design <strong>of</strong> conditioner <strong>Samsung</strong> does not mean <strong>the</strong> built<br />

in voltage stabilizer and additional <strong>the</strong> filter for smoothing <strong>of</strong> throws <strong>of</strong> pressure.<br />

Malfunctions <strong>of</strong> a household series <strong>of</strong> <strong>conditioners</strong> <strong>Samsung</strong>:<br />

<strong>Samsung</strong> AQV 09/12/18/24 PSB,<br />

Самсунг AQV 09/12/18/24 ABA,<br />

samsung AQ 07/09/12/18/24 EWF,<br />

самсунг AQ 07/09/12/18/24 TSB,<br />

Malfunctions <strong>of</strong> <strong>conditioners</strong> <strong>Samsung</strong>, codes and possible errors.<br />

DVM Plus III — HR Plus III <strong>Samsung</strong> AVX - CSH, C2H, C4H, CMH, DSH, DUH, TFH<br />

DVM Plus III — HR Plus III <strong>Samsung</strong> AVX - WVH, TJH, WNH, WBH<br />

Conditioners <strong>Samsung</strong> household SH — EAV 1<br />

Мини cartridge <strong>Samsung</strong> TH — EAV 1<br />

<strong>Samsung</strong>. Conditioners <strong>of</strong> cassette type CH — EAV 1<br />

EH - EAV 1<br />

<strong>Samsung</strong>. Channel <strong>conditioners</strong> <strong>of</strong> series DH — EAV 1<br />

Columned <strong>conditioners</strong> <strong>Samsung</strong> <strong>of</strong> an error. FH — EAV 1<br />

Standtruhe JH — EAV 1<br />

Multi-split-systems <strong>Samsung</strong> MH FNEA,-FBEA,-FVEA,-FKEA,-FMEA,-FJEA<br />

Duo Split MH-VV (VF)<br />

Series сплит systems <strong>Samsung</strong> AQ — NSA,-NSB<br />

Inverter <strong>Samsung</strong> AQV - NSAN,-WAN,-VBCN<br />

Service manual <strong>Samsung</strong>, <strong>the</strong> service book. A source. The reference. kody_neispravnostei_samsung<br />

CODES OF ERRORS<br />

Mitsubishi Heavy | <strong>Codes</strong> <strong>of</strong><br />

errors <strong>of</strong> Mitsubishi Heavy<br />

Daikin, <strong>the</strong> table <strong>of</strong><br />

<strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong><br />

Daikin, codes <strong>of</strong> errors<br />

Fujitsu, General Fujitsu.<br />

Conditioner Fujitsu<br />

malfunction codes, control<br />

<strong>of</strong> errors <strong>of</strong> system or<br />

System Controller Error<br />

Panasonic, conditioner<br />

repair | <strong>Codes</strong> <strong>of</strong> errors<br />

Panasonic<br />

Gree, — codes <strong>of</strong> errors and<br />

<strong>malfunctions</strong> | Simple repair<br />

LG | How to find an error<br />

by means <strong>of</strong> indicators —<br />

light-emitting diodes <strong>of</strong> <strong>the</strong><br />

internal block <strong>of</strong><br />

<strong>conditioners</strong><br />

Haier, codes <strong>of</strong><br />

<strong>malfunctions</strong> | Model HSU-<br />

09/12HVA103/R2 or <strong>the</strong>ir<br />

analogues<br />

Carrier, — codes <strong>of</strong> errors |<br />

Malfunctions сплит systems<br />

Carrier<br />

McQuay/Acson, — possible<br />

<strong>malfunctions</strong> | <strong>Codes</strong> <strong>of</strong><br />

errors<br />

AUX, DAX, JAX, Pioneer,<br />

Hansa, Saturn, Rolsen,<br />

Yamatsu, Daihatsu<br />

Mitsubishi Electric | Mr.<br />

Slim — control, codes <strong>of</strong><br />

<strong>malfunctions</strong>. Service<br />

Error code air conditioning<br />

| <strong>Codes</strong> <strong>of</strong> errors, originals<br />

pdf a file<br />

<strong>Samsung</strong> RAC and FJM codes<br />

<strong>of</strong> <strong>malfunctions</strong><br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]


<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

<strong>Codes</strong> <strong>of</strong> errors <strong>Samsung</strong>.<br />

Light-emitting diode (operating mode) =<br />

The blinking display <strong>of</strong> time = Yes<br />

Mode Turbo =<br />

The display <strong>of</strong> a control panel (code) = E1<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The internal block сплит systems, room термистор, — an<br />

error. The conditioner gauge is faulty. Resistance <strong>of</strong> <strong>the</strong> gauge does not correspond to<br />

П/У fig. 1.<br />

face value, — to check up on serviceability and to replace if necessary.<br />

Light-emitting diode (operating mode) = Yes<br />

The blinking display <strong>of</strong> time = Yes<br />

Mode Turbo =<br />

The display <strong>of</strong> a control panel (code) = E2<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The internal block <strong>of</strong> a pipe термистора an error — —<br />

Resistance <strong>of</strong> <strong>the</strong> gauge does not correspond to face value, — to check up on<br />

serviceability and to replace if necessary.<br />

Light-emitting diode <strong>Samsung</strong> (operating mode) =<br />

The blinking display <strong>of</strong> time =<br />

П/У fig. 2<br />

Mode Turbo = Yes<br />

The display <strong>of</strong> a control panel (code) = E3<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner samsung. The internal block <strong>of</strong> <strong>the</strong> engine <strong>of</strong> <strong>the</strong> fan <strong>of</strong> malfunction —<br />

to check up on serviceability and to replace if necessary.<br />

Light-emitting diode (operating mode) =<br />

The blinking display <strong>of</strong> time = Yes<br />

Mode Turbo = Yes<br />

The display <strong>of</strong> a control panel <strong>Samsung</strong> (code) = E6<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. EPROM an error, — to check up on serviceability and to replace<br />

<strong>the</strong> printed-circuit board if it is required.<br />

Light-emitting diode сплит systems (operating mode) = Yes<br />

The blinking display <strong>of</strong> time = Yes<br />

Mode Turbo = Yes<br />

The table fig. 1<br />

The display <strong>of</strong> a control panel (code) = blinking <strong>Samsung</strong><br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner. A variant an error code, — to check up and enter a<br />

new code a variant if it is required by means <strong>of</strong> a wireless remote control.<br />

Light-emitting diode (operating mode) = Yes<br />

The blinking display <strong>of</strong> time <strong>of</strong> <strong>the</strong> conditioner samsung =<br />

Mode Turbo = Yes<br />

The display <strong>of</strong> a control panel (code) =<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The gauge <strong>of</strong> temperature <strong>of</strong> external air unit — Resistance <strong>of</strong> <strong>the</strong> gauge does not<br />

correspond to face value — to check up on serviceability and to replace if necessary.<br />

Malfunctions. External block <strong>Samsung</strong>.<br />

Error code = Er — E1<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner samsung. The internal block at room<br />

temperature gives out a gauge error (will open / will close) — to check up on<br />

serviceability and to replace if necessary.<br />

Error code = Er — E5<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The gauge <strong>of</strong> <strong>the</strong> heat exchanger <strong>of</strong> device <strong>Samsung</strong> , — a<br />

temperature error (will open / will close) is closed, — to check up on serviceability and<br />

to replace if necessary.<br />

The table <strong>of</strong> codes fig. 2<br />

Error code = Er — 05<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The block heat exchanger сплит systems in a temperature error <strong>of</strong> <strong>the</strong> gauge (will open /<br />

will close) is closed — to check up on serviceability and to replace if necessary...<br />

Conditioner error code = Er — 06<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. EPROM an error, — to check up on serviceability and to replace<br />

<strong>the</strong> printed-circuit board if it is required.<br />

Error code = Er — 09<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A variant <strong>of</strong> <strong>Samsung</strong>a, an error code, — to check up and enter a<br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]


<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

new code a variant if it is required by means <strong>of</strong> a wireless remote control.<br />

Error code = Е3 — 01<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The fan <strong>of</strong> <strong>the</strong> internal block <strong>of</strong> <strong>the</strong> engine <strong>of</strong> <strong>the</strong> fan сплит<br />

systems and malfunction <strong>of</strong> a cable — to check up on serviceability and to replace if<br />

necessary.<br />

Error code = Er — 01<br />

The table <strong>of</strong> codes fig.<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The communication error between <strong>the</strong> internal block and <strong>the</strong><br />

3<br />

external block сплит systems, — to check up serviceability <strong>of</strong> interblock connection.<br />

Error code = Er — 11<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A critical error, — increase in a working current. To check up pressure in a network, if<br />

necessary. To dump pressure <strong>of</strong> gas in system on токовым to pincers. — 10 % from face value.<br />

Error code = Er — 12<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A critical error, — rise in temperature OLP<br />

Error code = Er — 13<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Critical error <strong>Samsung</strong>, — forcing rise in temperature<br />

Error code = Er — 14<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. For current ИПМ scheme Comp. The fan<br />

Conditioner error code = Er — 15<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A critical error <strong>of</strong> <strong>the</strong> conditioner, — increase in heat <strong>of</strong> <strong>the</strong><br />

fan temperature a bowl<br />

Error code = Er — 10<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. BLCD <strong>the</strong> conditioner compressor, beginning an error a<br />

computer. PCB, Comp a wire<br />

The table <strong>of</strong> codes<br />

Error code = Er — E6<br />

fig. 4<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. deice rate-gauge — to check up on serviceability and to<br />

replace if necessary.<br />

Error code = Er — 31<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The external temperature <strong>of</strong> <strong>the</strong> gauge — to check up on serviceability and to<br />

replace if necessary.<br />

Error code = Er — 32<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. To check up <strong>the</strong> gauge <strong>of</strong> temperature <strong>of</strong> forcing, — to check<br />

up on serviceability and to replace if necessary.<br />

Error code = Er — 33<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Forcing-gauge temperatures — to check up on serviceability and<br />

to replace if necessary.<br />

Conditioner error code = Er — 17<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. An error <strong>of</strong> communication <strong>Samsung</strong>a between 2 MiCOM on<br />

<strong>the</strong> open printed-circuit board<br />

Error code = Er — 36<br />

The table <strong>of</strong> codes fig. 5<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The gauge <strong>of</strong> a current <strong>of</strong> an error to a payment — to check<br />

up on serviceability and to replace if necessary.<br />

Error code = Er — 37<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>Samsung</strong>. A radiator <strong>of</strong> temperature <strong>of</strong> <strong>the</strong> gauge, an error in a management payment —<br />

to check up on serviceability and to replace if necessary.<br />

Error code = Er — 38<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner. Pressure <strong>of</strong> an error <strong>of</strong> <strong>the</strong> gauge — to check up on serviceability and<br />

to replace if necessary.<br />

Inverter <strong>Samsung</strong>. <strong>Codes</strong> <strong>of</strong> errors.<br />

<strong>Codes</strong> on Display = E1 01<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A communication error (<strong>the</strong> internal block cannot obtain <strong>the</strong> data) — Check up cables<br />

<strong>Codes</strong> on Display = E1 02<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner. A communication error (<strong>the</strong> external block<br />

not in a condition to communicate) — Check <strong>of</strong> addresses<br />

<strong>Codes</strong> on Display = E1 21<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The internal block to room temperature <strong>of</strong> an error <strong>of</strong> <strong>the</strong><br />

gauge (Open / Short) — to check up on serviceability and to replace if necessary.<br />

<strong>Codes</strong> on Display = E1 22<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner. The block — <strong>the</strong> evaporator <strong>of</strong> a pipe <strong>of</strong> an<br />

error <strong>of</strong> <strong>the</strong> gauge (Open / Short) is closed an error <strong>of</strong> <strong>the</strong> gauge — to check up on<br />

serviceability and to replace if necessary.<br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]


<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

<strong>Codes</strong> on Display = E1 23<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The block — <strong>the</strong> evaporator a tube from a gauge error (Open<br />

/ Short) is closed an error <strong>of</strong> <strong>the</strong> gauge — to check up on serviceability and to replace if<br />

necessary.<br />

Panel buttons. Where to<br />

press fingers? П/У 1<br />

<strong>Codes</strong> on Display = E1 28<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The block — <strong>the</strong> evaporator <strong>of</strong> a pipe from <strong>the</strong> gauge separate is closed an error <strong>of</strong> <strong>the</strong><br />

gauge<br />

<strong>Codes</strong> on Display = E1 30<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The heat exchanger and <strong>the</strong> device in from <strong>the</strong> temperature gauge <strong>the</strong> separate is closed<br />

<strong>Codes</strong> on Display = E1 54<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. It is closed <strong>malfunctions</strong> ventilating installation<br />

<strong>Codes</strong> on Display = E1 61<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner. More than 2 internal blocks <strong>of</strong> cooling and heating simultaneously<br />

<strong>Codes</strong> on Display = E1 62<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. EPROM an error.<br />

<strong>Codes</strong> on Display = E1 63<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. An option code wrong installation <strong>of</strong> <strong>the</strong> conditioner.<br />

<strong>Codes</strong> on Display = E1 85<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. There is no connecting cable, <strong>the</strong>re is no signal. An error.<br />

Display = E2 01<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Number <strong>of</strong> <strong>the</strong> internal block discrepancy<br />

Display = E2 02<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A communication error (in <strong>the</strong> open air could not obtain <strong>the</strong><br />

data)<br />

Display = E2 03<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. A communication error between two microcontroller on <strong>the</strong><br />

open printed-circuit board<br />

Display = E2 21<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Greetings from <strong>Samsung</strong>. It is closed an error <strong>of</strong> <strong>the</strong> gauge <strong>of</strong><br />

temperature (Short / to Open) — to check up on serviceability and to replace if<br />

necessary.<br />

What buttons to press?<br />

Display = E2 37<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The condenser <strong>of</strong> <strong>the</strong> gauge <strong>of</strong> temperature, — an error (Short / to Open) — to check up<br />

on serviceability and to replace if necessary.<br />

Display = E2 46<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The conditioner condenser is torn <strong>of</strong>f <strong>the</strong> temperature gauge, check up connection wires,<br />

колодка, — check up contact.<br />

Display = E2 51<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor <strong>of</strong> <strong>the</strong> category <strong>of</strong> an error <strong>of</strong> <strong>the</strong> gauge (Short / to Open) — to check up<br />

on serviceability and to replace if necessary.<br />

Display = E2 59<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. From will close unit error<br />

Display = E2 60<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor <strong>of</strong> <strong>the</strong> category <strong>of</strong> an error <strong>of</strong> <strong>the</strong> gauge (Short / to Open) — to check up<br />

on serviceability and to replace if necessary.<br />

Display = E2 61<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor <strong>of</strong> <strong>the</strong> category <strong>of</strong> <strong>the</strong> gauge <strong>the</strong> separate<br />

Display = E3 20<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner samsung. Compressor OLP <strong>of</strong> an error <strong>of</strong> <strong>the</strong> gauge (Short / to Open) —<br />

to check up on serviceability and to replace if necessary.<br />

<strong>Codes</strong> on Display = E4 01<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The heat exchanger and compressor stops (a cooling mode) is closed freezings <strong>the</strong>rmal unit<br />

<strong>Codes</strong> on Display = E4 04<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. ОтЗамкнут overloads <strong>of</strong> <strong>the</strong> block and a compressor stop (control protection in a heating<br />

mode)<br />

<strong>Codes</strong> on Display = E4 16<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The external block <strong>of</strong> high temperature <strong>of</strong> forcing and a compressor stop (a heating mode)<br />

<strong>Codes</strong> on Display = E4 19<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. External block EEV <strong>of</strong> open errors (self-diagnostics) — to check up on serviceability and to<br />

replace if necessary.<br />

<strong>Codes</strong> on Display = E4 22<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. External block EEV <strong>of</strong> close errors (self-diagnostics) — to check up on serviceability and to<br />

replace if necessary.<br />

<strong>Codes</strong> on Display = E4 40<br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]


<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. High temperature (above 30 °) in <strong>the</strong> open air, as a heating mode<br />

<strong>Codes</strong> on Display = E4 41<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Low temperatures <strong>of</strong> <strong>the</strong> conditioner samsung (to −5 °) Will close, as in a cooling mode<br />

<strong>Codes</strong> on Display = E4 60<br />

Elimination <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>the</strong> conditioner samsung. Wrong connection between communications<br />

and a food cable<br />

<strong>Codes</strong> on Display = E4 61<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor inverter, beginning failures (5 times)<br />

<strong>Codes</strong> on Display = E4 62<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor a trip <strong>of</strong> an entrance current <strong>of</strong> <strong>the</strong> relay <strong>of</strong> protection<br />

<strong>Codes</strong> on Display = E4 63<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor trip OLP control <strong>of</strong> a temperature limit<br />

<strong>Codes</strong> on Display = E4 64<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor a peak current <strong>of</strong> protection<br />

<strong>Codes</strong> on Display = E4 65<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Protection against a compressor overload <strong>the</strong> operating<br />

<strong>Codes</strong> on Display = E4 66<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Chains <strong>of</strong> a direct current pressure <strong>of</strong> an error (at 150V or 410V more)<br />

<strong>Codes</strong> on Display = E4 67<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The compressor <strong>of</strong> rotation to an error<br />

<strong>Codes</strong> on Display = E4 68<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. The current error <strong>of</strong> <strong>the</strong> gauge — to check up on serviceability and to replace if<br />

necessary.<br />

<strong>Codes</strong> on Display = E4 69<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Chains <strong>of</strong> a direct current pressure <strong>of</strong> an error <strong>of</strong> <strong>the</strong> gauge — to check up on<br />

serviceability and to replace if necessary.<br />

<strong>Codes</strong> on Display = E4 70<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. Protection against an overload <strong>of</strong> <strong>the</strong> compressor <strong>of</strong> <strong>the</strong> conditioner samsung — check <strong>of</strong><br />

a coolant and heat exchangers<br />

<strong>Codes</strong> on Display = E4 71<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. EPROM an error — to check up on serviceability and to replace <strong>the</strong> printed-circuit board<br />

if it is required<br />

<strong>Codes</strong> on Display = E4 72<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. AC lines <strong>of</strong> crossing <strong>of</strong> zero <strong>of</strong> detection <strong>of</strong> errors <strong>of</strong> a chain — Check up a food<br />

Display = E5 54<br />

Elimination <strong>of</strong> <strong>malfunctions</strong>. There is no coolant <strong>of</strong> errors (self-diagnostics) — coolant Check<br />

Similar records:<br />

1. Daikin codes <strong>of</strong> errors | Malfunctions <strong>of</strong> <strong>conditioners</strong> Dajkin Daichi<br />

2. The table <strong>of</strong> codes <strong>of</strong> <strong>malfunctions</strong> LG | How to find an error by means <strong>of</strong> indicators — light-emitting<br />

diodes <strong>of</strong> <strong>the</strong> internal block <strong>of</strong> <strong>conditioners</strong><br />

3. Mitsubishi Electric <strong>conditioners</strong> | Malfunctions сплит systems, codes <strong>of</strong> errors<br />

4. Mitsubishi Heavy | <strong>Codes</strong> <strong>of</strong> errors | Malfunctions сплит Mitsubishi systems<br />

5. <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> Fujitsu, General Fujitsu | What and when button to press? Repair сплит systems<br />

6. Gree, — codes <strong>of</strong> errors and <strong>malfunctions</strong> | Simple repair<br />

7. Haier, codes <strong>of</strong> <strong>malfunctions</strong> | Model HSU-09/12HVA103/R2 or <strong>the</strong>ir analogues.<br />

8. Panasonic, for conditioner repair | we Search and we rectify system errors | <strong>Codes</strong> <strong>of</strong> errors Panasonic<br />

<strong>Codes</strong> <strong>of</strong> errors<br />

Conditioners | Diagnostics | The inverter | <strong>the</strong> Central conditioner<br />

Check up a site Split Rostov on errors HTML5 and CSS<br />

Split Rostov © 2011. All rights reserved.<br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]


<strong>Samsung</strong> | <strong>Codes</strong> <strong>of</strong> <strong>malfunctions</strong> <strong>of</strong> <strong>conditioners</strong> | <strong>the</strong> <strong>Insertion</strong> <strong>of</strong> a payment <strong>of</strong> <strong>Samsung</strong>:: Split Rostov<br />

http://split61.ru/remont/kody-oshibok/samsung-kody-neispravnostej-kondicionerov-proshivka-platy-samsung.html[17.12.2011 9:40:59]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!