13.11.2014 Views

Price List 2013

Price List 2013

Price List 2013

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EDV - TT<br />

EDV - MF & LF<br />

EDV - MR & LR<br />

Table Top Units<br />

This compact dispense unit is an ideal<br />

solution where space is at a premium.<br />

Connected directly to the mains water<br />

supply, water is filtered and chilled but<br />

can still be served in still or sparkling<br />

variants.<br />

Free-standing units<br />

These self contained, wheeled units<br />

come in two different sizes and single<br />

dispense taps or dual-headed taps.<br />

Filters and cooling chambers are<br />

hidden inside but remain easily<br />

accessible from the door on the front.<br />

Remote cassette units<br />

The slot-in cassette version, available in<br />

two sizes, is operationally identical to<br />

its free-standing unit equivalent.<br />

It can however be installed on existing<br />

shelving and sited remotely from the<br />

dispense tap or taps, affording more<br />

flexibility in confined spaces.<br />

Specifications - EDV-TT<br />

Width ____________________________________ 408 mm<br />

Depth (Excluding Drip Tray) ________________ 533 mm<br />

Depth (Including Drip Tray) _________________ 626 mm<br />

Height (Main Unit) ________________________ 510 mm<br />

Height (Including Taps)_____________________ 540 mm<br />

Cold water mains potable supply ______ ¾ BSP Isolator<br />

Water Pressure _______________ Min 1.5 / Max 3.5 Bar<br />

Excess spillage into drip tray __ (No drainage required)<br />

Mains Supply ______________________ 230 V 1Ph 50 Hz<br />

Run Current______________________________ 5.1 Amps<br />

Start Current ____________________________ 10.7 Amps<br />

Fuse at __________________________________ 10 Amps<br />

Supply Lead __________ 2M Mains Cable 3 Pin UK Plug<br />

Specifications - EDV-MF<br />

Width ___________________________________ 1000 mm<br />

Depth ____________________________________ 750 mm<br />

Height (Including wheels and tap) _________ 1485 mm<br />

Height (Excluding tap) _____________________ 905 mm<br />

Cold water mains potable supply ______ ¾ BSP Isolator<br />

___________________________________(3/4 BSP - 3/8 Adaptor required)<br />

Water Pressure _______________ Min 1.5 / Max 3.5 Bar<br />

Excess spillage into drip tray __ (No drainage required)<br />

Mains Supply ______________________ 230 V 1Ph 50 Hz<br />

_______________________________________(Rated input 800 Watts)<br />

Run Current_____________________________ 3.47 Amps<br />

Start Current _____________________________ 7.0 Amps<br />

Fuse at __________________________________ 10 Amps<br />

Supply Lead __________ 2M Mains Cable 3 Pin UK Plug<br />

Specifications - EDV-MR<br />

Width ____________________________________ 500 mm<br />

Depth ____________________________________ 600 mm<br />

Height (Including wheels and tap)___________ 720 mm<br />

Cold water mains potable supply ______ ¾ BSP Isolator<br />

___________________________________(3/4 BSP - 3/8 Adaptor required)<br />

Water Pressure _______________ Min 1.5 / Max 3.5 Bar<br />

Excess spillage into drip tray __ (No drainage required)<br />

Mains Supply ______________________ 230 V 1Ph 50 Hz<br />

_______________________________________(Rated input 800 Watts)<br />

Run Current_____________________________ 3.47 Amps<br />

Start Current _____________________________ 7.0 Amps<br />

Fuse at __________________________________ 10 Amps<br />

Supply Lead __________ 2M Mains Cable 3 Pin UK Plug<br />

Specifications - EDV-LF<br />

Width ___________________________________ 1000 mm<br />

Depth ____________________________________ 750 mm<br />

Height (Including wheels and tap) _________ 1485 mm<br />

Height (Excluding tap) _____________________ 905 mm<br />

Cold water mains potable supply ______ ¾ BSP Isolator<br />

___________________________________(3/4 BSP - 3/8 Adaptor required)<br />

Water Pressure _______________ Min 1.5 / Max 3.5 Bar<br />

Excess spillage into drip tray __ (No drainage required)<br />

Mains Supply ______________________ 230 V 1Ph 50 Hz<br />

_______________________________________(Rated input 800 Watts)<br />

Run Current_____________________________ 3.47 Amps<br />

Start Current _____________________________ 7.0 Amps<br />

Fuse at __________________________________ 10 Amps<br />

Supply Lead __________ 2M Mains Cable 3 Pin UK Plug<br />

Specifications - EDV-LR<br />

Width ____________________________________ 800 mm<br />

Depth ____________________________________ 600 mm<br />

Height (Including wheels and tap)___________ 720 mm<br />

Cold water mains potable supply ______ ¾ BSP Isolator<br />

___________________________________(3/4 BSP - 3/8 Adaptor required)<br />

Water Pressure _______________ Min 1.5 / Max 3.5 Bar<br />

Excess spillage into drip tray __ (No drainage required)<br />

Mains Supply ______________________ 230 V 1Ph 50 Hz<br />

_______________________________________(Rated input 800 Watts)<br />

Run Current_____________________________ 3.47 Amps<br />

Start Current _____________________________ 7.0 Amps<br />

Fuse at __________________________________ 10 Amps<br />

Supply Lead __________ 2M Mains Cable 3 Pin UK Plug<br />

Table Top Unit - Capacity<br />

Free Standing Units - Capacity<br />

Remote Cassette Units - Capacity<br />

Model<br />

Table Top<br />

Unit<br />

510<br />

533<br />

408<br />

Product<br />

code<br />

EDV-TT<br />

Water production<br />

litres per hour<br />

25 33<br />

Continuous<br />

bottle<br />

production<br />

<strong>Price</strong> £3050<br />

Model<br />

Medium<br />

Free-standing<br />

Unit<br />

905<br />

600<br />

600<br />

1485<br />

905<br />

Product<br />

code<br />

EDV-MF<br />

Water production<br />

litres per hour<br />

70<br />

Continuous<br />

bottle<br />

production<br />

72<br />

<strong>Price</strong> £7355<br />

Model<br />

Medium<br />

Remote Unit<br />

720<br />

600<br />

500<br />

Product<br />

code<br />

EDV-MR<br />

Water production<br />

litres per hour<br />

70 72<br />

Continuous<br />

bottle<br />

production<br />

<strong>Price</strong> £6730<br />

600<br />

1485<br />

600<br />

800<br />

Large<br />

Free-standing<br />

Unit<br />

905<br />

600<br />

905<br />

EDV-LF<br />

100 108<br />

Large<br />

Remote Unit<br />

720<br />

EDV-LR<br />

100 108<br />

<strong>Price</strong> £7880 <strong>Price</strong> £7255<br />