Synchronous timers TMR1...TMR4 group:<br />
* - index from 1 to 4<br />
Parameter <strong>MT</strong>Manager description<br />
Default<br />
value<br />
Range<br />
TMR_ON_* Active 2<br />
1<br />
2<br />
TMR_START_* Start [HH:MM] 00:00 00:00...23:59<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
TMR_PERIOD_* Period 14<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
TMR_DOFW_* Days of week 7F from 00 to 7F<br />
TMR_DOFM_* Days of month 00000000<br />
from 00000000<br />
to FFFFFFFF<br />
Definition<br />
Yes<br />
No<br />
1 min.<br />
2 min.<br />
3 min.<br />
5 min.<br />
10 min.<br />
15 min.<br />
30 min.<br />
1 hour.<br />
2 hours.<br />
3 hours.<br />
4 hours.<br />
6 hours.<br />
8 hours.<br />
12 hours.<br />
24 hours.<br />
Days of week<br />
when timer is<br />
active.<br />
1 - Monday<br />
2 - Tuesday<br />
4 - Wednesday<br />
8 - Thursday<br />
10 - Friday<br />
20 - Saturday<br />
40 - Sunday<br />
e.g. Wednesday,<br />
Thursday and<br />
Friday is 1C.<br />
Days of month<br />
when timer is<br />
active. Bit=1 -<br />
day is selected.<br />
Representation -<br />
see reference 2.<br />
State logging group:<br />
Parameter <strong>MT</strong>Manager description Default value Range Definition<br />
STWS Start [HH:MM] 00:00 00:00...23:59<br />
STWP Period 9<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
STWI Logged information empty<br />
max. 160<br />
characters<br />
10 min.<br />
20 min.<br />
30 min.<br />
45 min.<br />
1 h<br />
2 h<br />
3 h<br />
4 h<br />
6 h<br />
8 h<br />
12 h<br />
24 h<br />
75