Authorized numbers group:<br />

* - index from 1 to 32<br />

Parameter <strong>MT</strong>Manager description<br />

Default<br />

value<br />

Range<br />

LPHN Number of phone numbers 1 1...32<br />

SPBS<br />

SALS<br />

Update phone numbers from SIM<br />

card<br />

Phone number from SIM card<br />

always authorized<br />

SMST_* Name NUM * max. 16 characters<br />

SMSN_* Number +48 max. 14 characters<br />

SCFG Configuration FFFFFFFF<br />

SINQ Query 00000000<br />

SMS_AUT Receiving voice calls 00000000<br />

1<br />

1<br />

1<br />

2<br />

1<br />

2<br />

from 00000000<br />

to FFFFFFFF<br />

from 00000000<br />

to FFFFFFFF<br />

from 00000000<br />

to FFFFFFFF<br />

Definition<br />

No<br />

Yes<br />

No<br />

Yes<br />

Bits defining<br />

configuration<br />

access<br />

authorization.<br />

Bit=1 -<br />

authorization<br />

granted.<br />

Representation -<br />

see reference 1.<br />

Bits defining data<br />

polling<br />

authorization.<br />

Bit=1 -<br />

authorization<br />

granted.<br />

Representation -<br />

see reference 1.<br />

Bits defining<br />

receiving calls<br />

authorization.<br />

Bit=1 -<br />

authorization<br />

granted.<br />

Representation -<br />

see reference 1.<br />

Resources group:<br />

Parameter<br />

<strong>MT</strong>Manager description<br />

Default<br />

value<br />

Range<br />

Binary inputs I1...I4 (counter inputs) * -index from 1 to 4<br />

IN_NAME_* Name I* max. 16 characters<br />

IN_MODE_* Input type 1<br />

1<br />

3<br />

IN_DIR_* Counting direction 1<br />

1<br />

2<br />

IN_RANGE_* Counting range (32bits) 0 0...2147483647<br />

1<br />

IN_EDGE_* Triggering slope 1<br />

2<br />

3<br />

IN_FLR_* Filtering constant [s] 10 10...16383<br />

Relay outputs Q1...Q4 * - index from 1 to 4<br />

OUT_NAME_* Name Q* max. 16 characters<br />

OUT_IMP_* Output mode 1<br />

1<br />

2<br />

OUT_IMPLEN_* Pulse duration [s] 1 1...3600<br />

OUT_ONEVT_* On event 0<br />

0<br />

1<br />

...<br />

16<br />

Definition<br />

Binary input<br />

Counter input<br />

Up<br />

Down<br />

Bi 0->1<br />

Bi 1->0<br />

Bi 0->1|1->0<br />

unit is value/100<br />

[s]<br />

Monostable<br />

Bistable<br />

unit is value/10<br />

[s]<br />

None<br />

EVT1<br />

...<br />

EVT16<br />

(* - index from 1<br />

to 16)<br />

73