Default value - 1<br />
Comments - N/A<br />
6.2.3.8.2. Macro name<br />
Function - Defines macro's user friendly name<br />
Data type - Text<br />
Range - 0..20 characters<br />
Default value - M0<br />
Comments - N/A<br />
6.2.3.8.3. Macro's content<br />
Function - The content that is inserted into the SMS message,<br />
instead of macro name.<br />
Data type - text<br />
Range - 0..160 characters<br />
Default value - #lt.ir0 #ld.ir0<br />
Comments - N/A<br />
6.2.4. GPRS<br />
GPRS group contains parameters related to GPRS transmission an logging.<br />
6.2.4.1. APN name<br />
Function<br />
Data type<br />
Range<br />
Default value<br />
Comments<br />
- defines APN name selected for GPRS transmission<br />
- text<br />
- letters, numerals, special characters - max. 63 characters<br />
- empty<br />
- absence of APN name disables login to GPRS network<br />
6.2.4.2. APN user name<br />
Function<br />
Data type<br />
Range<br />
Default value<br />
Comments<br />
- defines APN user name<br />
- text<br />
- letters, numerals, special characters - max. 31 characters<br />
- empty<br />
- Optional parameter used only if required by GSM network<br />
operator<br />
6.2.4.3. APN password<br />
Function<br />
Data type<br />
Range<br />
- defines password for APN user account<br />
- text<br />
- letters, numerals, special characters - max. 31 characters<br />
37