6.2.1.11. Last reading time<br />
Function<br />
Data type<br />
Range<br />
Comments<br />
- displays internal module time recorded during last<br />
configuration reading or during last time setting<br />
- text<br />
- compliant with Date and Time format<br />
- this field is useful in verifying last access time and checking<br />
internal module clock settings (RTC)<br />
6.2.2. General<br />
General group encompasses parameters vital for whole module.<br />
Contains data necessary for successful login to GSM network and password-protection<br />
module configuration.<br />
Note: values set here have impact on module's behavior and in worst case, when chosen<br />
improperly may even lock the module.<br />
6.2.2.1. SIM card PIN number<br />
Function - defines PIN access code for SIM module delivered by GSM<br />
operator. For SIM modules not protected by PIN code, the<br />
value is insignificant.<br />
Data type - Number<br />
Range - numerals, from 4 to 8 characters<br />
Default value - empty<br />
Comments - wrong pin can cause locking of SIM module<br />
CAUTION!<br />
Caution is vital when setting the PIN code value. Entering faulty PIN<br />
code may cause module start-up to be impossible and lock SIM card.<br />
In latest versions of the module, attempting to enter wrong PIN code<br />
twice renders a third attempt impossible.<br />
Procedure in case of blocked module as the result of the wrong PIN value<br />
6.2.2.2. Configuration password<br />
Function - defines the password protecting access to configuration<br />
of the module. The password will be required for both<br />
local and remote access, thus protecting against<br />
unauthorized configuration alterations. The password<br />
does not protect against reading current configuration or<br />
the module status.<br />
Data type - text string<br />
Range - letters and numerals, max. 32 characters<br />
Default value - n/a<br />
Comments - since the only way of unlocking the module is resetting it<br />
to factory settings, it is vital that the password is stored in<br />
a safe way and available when needed.<br />
31