44. South of San Onofre<br />

Revised February 2005<br />

Accepted <strong>Rating</strong><br />

Existing <strong>Rating</strong><br />

Other<br />

Location: South of San Onofre Nuclear Generating Station (SONGS)<br />

San Onofre Interconnection, San Diego County, California<br />

Definition: South of SONGS Lines Metered End<br />

SONGS-San Luis Rey<br />

SONGS<br />

SONGS-San Luis Rey<br />

SONGS<br />

SONGS- San Luis Rey<br />

SONGS<br />

SONGS-Talega #1<br />

SONGS<br />

SONGS-Talega #2<br />

SONGS<br />

Transfer Limit: North to South: 2200/2500 MW (see System Conditions below)<br />

Critical<br />

Disturbance<br />

that limits the<br />

transfer<br />

capability:<br />

South to North: No longer required based on determination made in 1999<br />

through WECC review.<br />

(See letter from PCC Chairman to PCC, OC, and TSS dated June 26, 2001)<br />

The 2200 MW north to south rating is based on flowability on the path under<br />

normal conditions.<br />

During critical contingency operating conditions with a 2500 MW north to<br />

south flow, outage of SCE’s Del Amo-Ellis 230 kV line loads the Barre-Ellis<br />

230 kV line to 99.8% of its N-1 contingency “A” rating of 2850 amps.<br />

When: Accepted dual ratings were approved by PCC on February 11, 2000.<br />

System<br />

For north to south flow, the 2200 MW rating is applicable under normal<br />

Conditions: conditions. The 2500 MW rating is applicable only for times when any<br />

segment of the Southwest PowerLink is out of service for any reason.<br />

Study Criteria: WECC, SDGE, and the California ISO.<br />

Remedial<br />

Actions<br />

Required:<br />

Formal<br />

Operating<br />

Procedure:<br />

Allocation:<br />

Interaction<br />

w/Other<br />

Transfer <strong>Path</strong>s:<br />

Contact Person:<br />

The need for arming RAS for local load shedding will be determined by the<br />

California ISO and SDGE during seasonal operating studies, however, no<br />

load shedding requirement has been identified at this time.<br />

None<br />

San Diego Gas & Electric owns lines as defined above. The California ISO<br />

exercises operational control of the lines and associated facilities.<br />

None<br />

Will Speer<br />

San Diego Gas & Electric<br />

8316 Century Park Court, CP52A<br />

San Diego, CA 92123-1582<br />

Ph: (858) 654-6477<br />

Fax: (858) 654-1692<br />