Oil Alert System<br />

The Oil Alert system is designed to prevent engine damage caused<br />

by an insufficient amount of oil in the crankcase. Before the oil level in<br />

the crankcase can fall below a safe limit, the Oil Alert system will<br />

automatically stop the engine (the engine switch will remain in the ON<br />

position). The Oil Alert system should not take the place of checking<br />

the oil level before each use.<br />

If the engine stops and will not restart, check the engine oil level (see<br />

page 30)<br />

before troubleshooting in other areas.<br />

Auto Throttle System<br />

The Auto Throttle system automatically reduces engine speed when<br />

all loads are turned off or disconnected. When appliances are turned<br />

on or reconnected, the engine returns to the rated speed.<br />

Switch Position<br />

AUTO: Recommended to minimize fuel consumption and further<br />

reduce noise levels when no load is applied to the generator.<br />

OFF: The Auto Throttle system does not operate.<br />

Recommended to minimize warm-up time when the<br />

generator is started and when starting a load with large startup<br />

power equipments.<br />

AUTO THROTTLE SWITCH<br />

OFF<br />

OFF<br />

ON<br />

ON<br />