L i n M o t ®<br />

Motion Control SW<br />

Can be used in a linked command table sequence.<br />

4.3.177 Wait Until Difference Position Greater Than (224xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 224xh: Wait Until Difference Position Greater Than UInt16 -<br />

1. Par 2 Diff Pos Trig Level SInt32 0.1 um<br />

Can be used in a linked command table sequence.<br />

4.3.178 Wait Until Difference Position Less Than (225xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 225xh: Wait Until Difference Position Less Than UInt16 -<br />

1. Par 2 Diff Pos Trig Level SInt32 0.1 um<br />

Can be used in a linked command table sequence.<br />

4.3.179 Wait Until Difference Position Unsigned Greater Than (226xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 226xh: Wait Until Difference Position Unsigned UInt16 -<br />

Greater Than<br />

1. Par 2 Diff Pos Trig Level SInt32 0.1 um<br />

Can be used in a linked command table sequence.<br />

4.3.180 Wait Until Difference Position Unsigned Less Than (227xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 227xh: Wait Until Difference Position Unsigned UInt16 -<br />

Less Than<br />

1. Par 2 Diff Pos Trig Level SInt32 0.1 um<br />

Can be used in a linked command table sequence.<br />

4.3.181 Wait Until Demand Velocity Greater Than (228xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 228xh: Wait Until Demand Velocity Greater Than UInt16 -<br />

1. Par 2 Dem Vel Trig Level SInt32 1E-6 m/s<br />

Can be used in a linked command table sequence.<br />

4.3.182 Wait Until Demand Velocity Less Than (229xh)<br />

Name Byte Description Type Unit<br />

Offset<br />

Header 0 229xh: Wait Until Demand Velocity Less Than UInt16 -<br />

1. Par 2 Dem Vel Trig Level SInt32 1E-6 m/s<br />

Can be used in a linked command table sequence.<br />