Specification sheet (English) - Trend
Specification sheet (English) - Trend
Specification sheet (English) - Trend
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
IQ23x<br />
Data Sheet<br />
Cables: The KIT/NODE/IQ23x contains the cables which are required to connect a node to the IQ23x.<br />
Connection Description Connectors Code Applies to Available in Notes<br />
Power<br />
Network<br />
24 Vdc supply to<br />
node<br />
<strong>Trend</strong> network<br />
connection<br />
2 pin in line polarised<br />
socket (Molex) to<br />
two screw terminal<br />
socket. 450 mm<br />
4 pin in line polarised<br />
socket to 4 screw<br />
terminal socket. 500<br />
mm<br />
<strong>Trend</strong> internetwork external wiring to<br />
4 screw terminal<br />
socket<br />
LonWorks external wiring to 2<br />
off 2 way terminal<br />
sockets<br />
Earth Earth connection<br />
between IQ23x and<br />
node<br />
RS232<br />
PSTN<br />
Device/Printer<br />
connection<br />
0.25” fast-on blade<br />
type receptacle to<br />
0.25” fast-on blade<br />
type receptacle. 210<br />
mm<br />
10 pin in line<br />
polarised socket<br />
(Molex) to 25 way<br />
female D type. 200<br />
mm<br />
EJ103087 all nodes KIT/NODE/<br />
IQ23x<br />
EJ103086 all nodes except LINC. KIT/NODE/<br />
IQ23x<br />
- INC.<br />
ANC, AND, XN28, TMN if<br />
on internetwork.<br />
LINC if internetworkLon<br />
extension.<br />
Screw terminals must<br />
connect to correct<br />
terminal pins on node.<br />
Not used by INC if used<br />
as internetwork repeater,<br />
or ANC, AND, XN28,<br />
TMN on internetwork.<br />
LINC requires 2 off 2 way<br />
terminal sockets, and<br />
doesn’t use this cable if<br />
used as internetwork Lon<br />
extension.<br />
- Bring wires though 1 cm<br />
diameter knockout<br />
- LINC - Bring wires through1 cm<br />
diameter knockout<br />
EJ101835 all nodes KIT/NODE/<br />
IQ23x<br />
EJ100179A001<br />
(was 78-0902)<br />
Black sheath<br />
Modem 10 pin in line EJ103817<br />
polarised socket Red sheath<br />
(Molex) to 25 way<br />
male D type. 230<br />
mm<br />
10 pin in line socket<br />
(Stocko) to 25 way<br />
male D type. 230<br />
mm<br />
Non-<strong>Trend</strong> device Special wiring to 10<br />
pin in line socket<br />
(Stocko)<br />
Flying lead to BT600<br />
plug<br />
Fibre optic to EMMPO meter<br />
Flying lead, optic<br />
cable from meter<br />
plugs into socket<br />
in adapter<br />
78-0903/1<br />
No sheath<br />
CNC, CNC2, PNC, PNC2<br />
TMNE<br />
ANC, AND, XN28<br />
KIT/NODE/<br />
IQ23x<br />
KIT/NODE/<br />
IQ23x<br />
KIT/NODE/<br />
IQ23x<br />
-<br />
If plug and socket are not<br />
both polarised, ensure<br />
correct polarity.<br />
D type fixes in RS232/<br />
Modem knockout.<br />
Additional external<br />
adapter<br />
cable<br />
required:PNC(2), to<br />
connect to printer (25<br />
way D type male to male<br />
cable, pins 3, 7 , and<br />
20 connected straight<br />
though); CNC(2), to<br />
connect to supervisor<br />
(25 way D type male to<br />
9 way D type female -<br />
CABLE/58-0750)<br />
If plug and socket are not<br />
both polarised, ensure<br />
correct polarity.<br />
D type fixes in RS232/<br />
Modem knockout.<br />
Additional external<br />
adapter cable require<br />
(25 way D type female<br />
to 25 way D type male -<br />
CABLE/58-2984)<br />
- XNC+ - If plug and socket are not<br />
both polarised, ensure<br />
correct polarity.<br />
- MNC, TMNH supplied with<br />
node<br />
- ENC supplied<br />
with meter<br />
Bring cable through 1<br />
cm diameter knockout<br />
(remove adapter from<br />
TMNH cable first)<br />
Bring cable through 1<br />
cm diameter knockout<br />
8 IQ23x Series Controllers Data Sheet TA200538 Issue 2, 18-Jan-2012