APPROVED COMPONENTS Bolt Size Seismic Approval: Transverse and Longitudinal Bracing of Pipe or Conduit. Underwriter's Laboratories Listed for 3 /4" (20mm) thru 8" (200mm). Complies with Federal Specification WW-H-171E Type 4 and Manufacturers' Standardization Society SP-69 Type 4. C U ® L LISTED US C U ® L US B3140 Series STANDARD PIPE CLAMP Nominal Bolt Maximum Design Load For Service Temp. Part No. Pipe Size Size 650°F (343°C) 750°F (399°C) in. (mm) lbs. kN lbs. kN B3140- 1 /2 1/2" (15) 5/16"-18 x 1 1 /4" 500 (2.22) 390 (1.73) B3140- 3 /4 3/4" (20) 5/16"-18 x 1 1 /4" 500 (2.22) 390 (1.73) B3140-1 1" (25) 5 /16"-18 x 1 1 /4" 500 (2.22) 390 (1.73) B3140-1 1 /4 1 1 /4" (32) 5/16"-18 x 1 1 /4" 500 (2.22) 390 (1.73) B3140-1 1 /2 1 1 /2" (40) 5/16"-18 x 1 1 /4" 800 (3.56) 620 (2.76) B3140-2 2" (50) 1/2"-13 x 2" 1040 (4.62) 810 (3.60) B3140-2 1 /2 2 1 /2" (65) 1/2"-13 x 2" 1040 (4.62) 810 (3.60) B3140-3 3" (80) 1/2"-13 x 2" 1040 (4.62) 810 (3.60) B3140-3 1 /2 3 1 /2" (90) 1/2"-13 x 2" 1040 (4.62) 810 (3.60) B3140-4 4" (100) 5/8"-11 x 2 1 /4" 1040 (4.62) 810 (3.60) B3140-5 5" (125) 5/8"-11 x 2 1 /2" 1040 (4.62) 810 (3.60) B3140-6 6" (150) 3/4"-10 x 2 3 /4" 1615 (7.18) 1260 (5.60) B3140-8 8" (200) 3/4"-10 x 3" 1615 (7.18) 1260 (5.60) See note D) on page 9 for required tightening torques. COOPER B-Line 509 West Monroe Street Highland, Illinois 62249 Phone: 800-851-7415 Fax: 618-654-1917 Date: Page No. Sheet Number: 6 - 2 - 06 67 of Raafat S. Aboulhosn Structural Engineer S 3913
APPROVED COMPONENTS Copper Adjustable Tubing Size Clevis Hanger Sleeve in. (mm) Part No. Part No.* 'A' (Rod Size) Hanger Rod Not Included 1/2" (15) B3104CT- 1 /2 B3104CTPS- 1 /2 3/4" (20) B3104CT- 3 /4 B3104CTPS- 3 /4 1" (25) B3104CT-1 B3104CTPS-1 1 1 /4" (32) B3104CT-1 1 /4 B3104CTPS-1 1 /4 1 1 /2" (40) B3104CT-1 1 /2 B3104CTPS-1 1 /2 2" (50) B3104CT-2 B3104CTPS-2 2 1 /2" (65) B3104CT-2 1 /2 B3104CTPS-2 1 /2 3" (80) B3104CT-3 B3104CTPS-3 3 1 /2" (90) B3104CT-3 1 /2 B3104CTPS-3 1 /2 4" (100) B3104CT-4 B3104CTPS-4 *Not included when ordering standard B3104CT Series Clevis Hanger. Finish: Dura-Copper Epoxy Paint. This non-metallic coating eliminates dissimilar metal contact between the hanger and the copper tubing. Seismic Approval: Transverse bracing of copper tubing (insulated or non-insulated). B3104CT Copper Tubing Clevis Hanger Nominal Rod Size Design Load Part No. Tubing Size 'A' in. (mm) lbs. (kN) B3104CT- 1 /2 1/2" (15) 3/8"-16 150 (0.67) B3104CT- 3 /4 3/4" (20) 3/8"-16 250 (1.11) B3104CT-1 1" (25) 3/8"-16 250 (1.11) B3104CT-1 1 /4 1 1 /4" (32) 3 /8"-16 250 (1.11) B3104CT-1 1 /2 1 1 /2" (40) 3/8"-16 250 (1.11) B3104CT-2 2" (50) 3 /8"-16 250 (1.11) B3104CT-2 1 /2 2 1 /2" (65) 1/2"-13 350 (1.55) B3104CT-3 3" (80) 1 /2"-13 350 (1.55) B3104CT-3 1 /2 3 1 /2" (90) 1/2"-13 350 (1.55) B3104CT-4 4" (100) 5/8"-11 400 (1.78) Note: When attaching seismic bracing to clevis hanger, install a B3104CTPS Pipe Sleeve over the cross bolt (See Figure 7 on page 16). Order B3104CTPS (Pipe Sleeve) separately. B3104CTPS Pipe Sleeve COOPER B-Line 509 West Monroe Street Highland, Illinois 62249 Phone: 800-851-7415 Fax: 618-654-1917 Date: Page No. Sheet Number: Raafat S. Aboulhosn Structural Engineer S 3913 6 - 2 - 06 68 of
- Page 19 and 20: CLEVIS HANGER TRANSVERSE BRACING (F
- Page 21 and 22: TRAPEZE BRACING TRAPEZE TRANSVERSE
- Page 23 and 24: TRAPEZE BRACING TRAPEZE TRANSVERSE
- Page 25 and 26: TRAPEZE BRACING Typical Trapeze ATR
- Page 27 and 28: STRUCTURAL ATTACHMENTS ‘T’ Conc
- Page 29 and 30: Concrete Attachments Detail 4 Metal
- Page 31 and 32: Concrete Attachments STRUCTURAL ATT
- Page 33 and 34: STRUCTURAL ATTACHMENTS Minimum dist
- Page 35 and 36: STRUCTURAL ATTACHMENTS Concrete Att
- Page 37 and 38: STRUCTURAL ATTACHMENTS Wood Beam At
- Page 39 and 40: STRUCTURAL ATTACHMENTS Wood Beam At
- Page 41 and 42: Structural Steel Detail 16 Case 1 C
- Page 43 and 44: Concrete Attachments To Slab HANGER
- Page 45 and 46: Concrete Attachments To Slab HANGER
- Page 47 and 48: Concrete Attachments To Slab HANGER
- Page 49 and 50: Concrete Attachments To Slab HANGER
- Page 51 and 52: Strut Attachments Typical All Threa
- Page 53 and 54: HANGER ROD ATTACHMENTS & APPROVED C
- Page 55 and 56: HANGER ROD ATTACHMENTS & APPROVED C
- Page 57 and 58: HANGER ROD ATTACHMENTS & APPROVED C
- Page 59 and 60: HANGER ROD SWIVEL ATTACHMENTS A 2 3
- Page 61 and 62: APPROVED COMPONENTS SC228 HANGER RO
- Page 63 and 64: APPROVED COMPONENTS NOTE: B633 can
- Page 65 and 66: APPROVED COMPONENTS Hardware SEISMI
- Page 67 and 68: APPROVED COMPONENTS 'A' (Rod Size)
- Page 69: APPROVED COMPONENTS 'A' (Rod Size)
- Page 73 and 74: APPROVED COMPONENTS Vertical Load S
- Page 75 and 76: APPROVED COMPONENTS Seismic Approva
- Page 77 and 78: APPROVED COMPONENTS 'A 'T' 2 'A 'T'
- Page 79 and 80: APPROVED COMPONENTS 2” (50.8mm) 3
- Page 81 and 82: APPROVED COMPONENTS 2 9 /16" (65mm)
- Page 83 and 84: APPENDIX - SEISMIC MAP SEISMIC MAP
- Page 85 and 86: Appendix 1 Support Spacing for Sing
- Page 87 and 88: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 89 and 90: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 91 and 92: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 93 and 94: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 95 and 96: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 97 and 98: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 99 and 100: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 101 and 102: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 103 and 104: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 105 and 106: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 107 and 108: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 109 and 110: SUPPORT SPACING FOR SINGLE ROD HANG
- Page 111 and 112: Appendix 2 Seismic Bracing Charts f
- Page 113 and 114: TRAPEZE BRACING Seismic Bracing Cha
- Page 115 and 116: TRAPEZE BRACING Seismic Bracing Cha
- Page 117 and 118: Seismic Bracing Charts for Trapeze
- Page 119 and 120: TRAPEZE BRACING Seismic Bracing Cha
APPROVED COMPONENTS<br />
Copper Adjustable<br />
Tubing Size Clevis Hanger Sleeve<br />
in. (mm) Part No. Part No.*<br />
'A'<br />
(Rod Size)<br />
Hanger Rod<br />
Not Included<br />
1/2" (15) B3104CT- 1 /2 B3104CTPS- 1 /2<br />
3/4" (20) B3104CT- 3 /4 B3104CTPS- 3 /4<br />
1" (25) B3104CT-1 B3104CTPS-1<br />
1 1 /4" (32) B3104CT-1 1 /4 B3104CTPS-1 1 /4<br />
1 1 /2" (40) B3104CT-1 1 /2 B3104CTPS-1 1 /2<br />
2" (50) B3104CT-2 B3104CTPS-2<br />
2 1 /2" (65) B3104CT-2 1 /2 B3104CTPS-2 1 /2<br />
3" (80) B3104CT-3 B3104CTPS-3<br />
3 1 /2" (90) B3104CT-3 1 /2 B3104CTPS-3 1 /2<br />
4" (100) B3104CT-4 B3104CTPS-4<br />
*Not included when ordering standard B3104CT Series<br />
Clevis Hanger.<br />
Finish: Dura-Copper Epoxy Paint.<br />
This non-metallic coating eliminates dissimilar<br />
metal contact between the hanger and the<br />
copper tubing.<br />
<strong>Seismic</strong> Approval:<br />
Transverse bracing of copper tubing<br />
(insulated or non-insulated).<br />
B3104CT<br />
Copper Tubing Clevis Hanger<br />
Nominal Rod Size Design Load<br />
Part No. Tubing Size 'A'<br />
in. (mm) lbs. (kN)<br />
B3104CT- 1 /2 1/2" (15) 3/8"-16 150 (0.67)<br />
B3104CT- 3 /4 3/4" (20) 3/8"-16 250 (1.11)<br />
B3104CT-1 1" (25) 3/8"-16 250 (1.11)<br />
B3104CT-1 1 /4 1 1 /4" (32) 3 /8"-16 250 (1.11)<br />
B3104CT-1 1 /2 1 1 /2" (40) 3/8"-16 250 (1.11)<br />
B3104CT-2 2" (50) 3 /8"-16 250 (1.11)<br />
B3104CT-2 1 /2 2 1 /2" (65) 1/2"-13 350 (1.55)<br />
B3104CT-3 3" (80) 1 /2"-13 350 (1.55)<br />
B3104CT-3 1 /2 3 1 /2" (90) 1/2"-13 350 (1.55)<br />
B3104CT-4 4" (100) 5/8"-11 400 (1.78)<br />
Note: When attaching seismic bracing to clevis<br />
hanger, install a B3104CTPS Pipe Sleeve over the<br />
cross bolt (See Figure 7 on page 16).<br />
Order B3104CTPS (Pipe Sleeve) separately.<br />
B3104CTPS<br />
Pipe Sleeve<br />
COOPER B-<strong>Line</strong><br />
509 West Monroe Street<br />
Highland, Illinois 62249<br />
Phone: 800-851-7415<br />
Fax: 618-654-1917<br />
Date:<br />
Page No.<br />
Sheet Number:<br />
Raafat S. Aboulhosn<br />
Structural Engineer S 3913<br />
6 - 2 - 06<br />
68<br />
of