the inverter that provides a reference voltage, which regulates the motor speed proportional to<br />

this reference voltage.<br />

After the system installation <strong>of</strong> Figure 1 be implanted in the laboratory, a test was<br />

performed to verify energy consumption with the use <strong>of</strong> the main line for all possible<br />

combinations (15 in total) <strong>of</strong> the four lots according to be irrigating (on) or not (<strong>of</strong>f), due to the<br />

fact that the irrigation system without the use <strong>of</strong> the inverter, in general, have a constant<br />

energy consumption.<br />

For each combination was checked the flow and pressure for each outlet pressure after<br />

the pump and before each record <strong>of</strong> the lot. Later, it was performed again the 15 combinations,<br />

but this time using the frequency inverter that, due to the rotation decrease, kept the pressure<br />

<strong>of</strong> 15 MCA for the more critical lot <strong>of</strong> the combination. For the situations was recorded the<br />

power consumed, reactive power, power factor and rotation <strong>of</strong> the motor shaft by means <strong>of</strong> a<br />

tachometer.<br />

1.2 Results and Discussion<br />

With the simulation were found the values <strong>of</strong> pressure for motor-pump and for each<br />

outlet pressure before leaving the lots, being these values obtained for each combination <strong>of</strong><br />

open and close <strong>of</strong> the record possible in the assembled district, as shown in Table 1.<br />

After found the pressures that could be in a real perimeter using the simulation, in a<br />

laboratory assembled a prototype and by the pressure drops register, assembled these<br />

pressures for each combination. As far as using only the engine or using motor coupled to the<br />

frequency inverter, always with a flow rate <strong>of</strong> 2.5 m 3 .h -1 .<br />

Table 1- Values found with the simulation for each point <strong>of</strong> record <strong>of</strong> each possible<br />

combination.<br />

Open Records in<br />

Points <strong>of</strong> outlet pressure (mca)<br />

the lots<br />

Combinations<br />

1 2 3 4 Pump Record 1 Record 2 Record Tomada 31<br />

Record 4<br />

1 X X X X 32.08 22.73 19.87 17.46 15.34<br />

2 X X X - 33.16 26.05 23.64 21.52 19.52<br />

3 X X - X 33.16 26.05 23.64 21.52 19.41<br />

4 X - X X 33.16 26.05 23.64 21.23 19.12<br />

5 - X X X 33.16 26.05 23.18 20.77 18.66<br />

6 X X - - 33.92 29.96 27.85 26.35 24.35<br />

7 X - X - 33.92 28.46 26.35 24.24 22.24<br />

8 X - - X 33.92 28.46 26.35 24.24 22.12<br />

9 - X X - 33.92 28.46 26.05 23.94 21.94<br />

10 - X - X 33.92 28.46 26.05 23.94 21.83<br />

11 - - X X 33.92 28.46 26.05 23.65 21.53<br />

12 X - - - 34.36 29.96 27.96 25.96 23.96<br />

13 - X - - 34.36 29.96 27.85 25.85 23.85<br />

14 - - X - 34.36 29.96 27.85 25.74 23.74<br />

15 - - - X 34.36 29.96 27.85 25.85 23.85<br />

(X )for opened record, (-) for closed record