LUMINAIRE TESTING LABORATORY, INC.<br />

SUSTAINING<br />

MEMBER<br />

of the<br />

IESNA<br />

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com<br />

LTL NUMBER: 28146 DATE: 2011-12-29<br />

PREPARED FOR: MAXLITE SK AMERICA, INC<br />

CATALOG NUMBER: <strong>MLAR100<strong>LED</strong>50</strong><br />

LUMINAIRE: CAST ALUMINUM HOUSING, MOLDED SPECULAR STEPPED<br />

PLASTIC REFLECTORS, BLACK LAMINATED GLASS<br />

ENCLOSURE WITH CLEAR SECTION BELOW <strong>LED</strong>S<br />

LAMP: 45 WHITE <strong>LED</strong>S<br />

<strong>LED</strong> POWER SUPPLY: ONE INVENTRONICS EUC-096S350ST<br />

ELECTRICAL VALUES: 120.0VAC, 0.8543A, 101.9W, PF=0.994<br />

LUMINAIRE EFFICACY: 68.3 LUMENS/WATT<br />

NOTE: THIS TEST WAS PERFORMED USING THE CALIBRATED<br />

PHOTODETECTOR METHOD OF ABSOLUTE PHOTOMETRY.*<br />

13.88"<br />

IES CLASSIFICATION: AREA LIGHT<br />

CUTOFF CLASSIFICATION: FULL-CUTOFF**<br />

**CUTOFF DESIGNATION IS NOT DEFINED FOR ABSOLUTE PHOTOMETRIC<br />

TESTS. THIS CUTOFF RATING IS BASED ON THE MAXIMUM CANDELA<br />

READING PER LUMINAIRE RATED AT 1000 LUMENS.<br />

10.00"<br />

0 Horizontal<br />

FLUX DISTRIBUTION<br />

LUMENS DOWNWARD UPWARD TOTALS<br />

HOUSE<br />

SIDE<br />

STREET<br />

SIDE<br />

3481.80 0.00 3481.80<br />

3481.80 0.00 3481.80<br />

TOTALS 6963.61 0.00 6963.61<br />

Approved By:<br />

*DATA WAS ACQUIRED USING THE CALIBRATED PHOTODETECTOR METHOD OF ABSOLUTE PHOTOMETRY. A UDT MODEL<br />

#211 PHOTODETECTOR AND UDT MODEL #S370 OPTOMETER COMBINATION WERE USED AS A STANDARD. A SPECTRAL<br />

MISMATCH CORRECTION FACTOR WAS EMPLOYED BASED ON THE SPECTRAL RESPONSIVITY OF THE PHOTODETECTOR AND<br />

THE SPECTRAL POWER DISTRIBUTION OF THE TEST SUBJECT.<br />

TESTING WAS PERFORMED IN ACCORDANCE WITH IES LM-79-08.<br />

TEST ANGULAR INCREMENTS AND REPORT FORMATTING WAS BASED ON IES LM-31-95 (WITHDRAWN).


0.02<br />

LUMINAIRE TESTING LABORATORY, INC.<br />

SUSTAINING<br />

MEMBER<br />

of the<br />

IESNA<br />

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com<br />

-3<br />

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION<br />

VALUES BASED ON 10.00 FOOT MOUNTING HEIGHT<br />

-2<br />

0.02<br />

0.01<br />

Transverse Distance in Units of Mounting Heights<br />

-1<br />

0<br />

1<br />

2<br />

2<br />

5<br />

1<br />

50<br />

5<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

2<br />

0.02<br />

10<br />

20<br />

0.01<br />

1<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

0.01<br />

street side house side<br />

3<br />

4<br />

5<br />

0 1 2 3 4 5 6 7<br />

Longitudinal Distance in Units of Mounting Heights<br />

PROJECTION OF HALF-MAX CANDELA CONTOUR<br />

PAGE 2-LTL NUMBER 28146


LUMINAIRE TESTING LABORATORY, INC.<br />

SUSTAINING<br />

MEMBER<br />

of the<br />

IESNA<br />

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com<br />

CANDELA DISTRIBUTION<br />

0 5 15 25 35 45 55 65 75 85 90<br />

180 0 0 0 0 0 0 0 0 0 0 0<br />

175 0 0 0 0 0 0 0 0 0 0 0<br />

165 0 0 0 0 0 0 0 0 0 0 0<br />

155 0 0 0 0 0 0 0 0 0 0 0<br />

145 0 0 0 0 0 0 0 0 0 0 0<br />

135 0 0 0 0 0 0 0 0 0 0 0<br />

125 0 0 0 0 0 0 0 0 0 0 0<br />

115 0 0 0 0 0 0 0 0 0 0 0<br />

105 0 0 0 0 0 0 0 0 0 0 0<br />

95 0 0 0 0 0 0 0 0 0 0 0<br />

90 0 0 0 0 0 0 0 0 0 0 0<br />

87.5 0 0 0 0 0 0 0 0 0 0 0<br />

85 0 0 0 0 0 0 0 0 0 0 0<br />

82.5 0 0 0 0 0 0 0 0 0 0 0<br />

80 0 0 0 0 0 0 0 0 0 0 0<br />

77.5 0 0 0 0 0 0 0 0 0 0 0<br />

75 0 1 0 0 0 0 0 0 1 2 2<br />

72.5 6 6 3 2 0 0 1 3 4 7 7<br />

70 10 10 7 5 4 1 4 6 8 11 11<br />

67.5 14 14 11 9 7 4 7 11 13 16 15<br />

65 21 22 17 15 11 8 12 15 18 23 22<br />

62.5 28 29 22 19 15 12 16 20 23 31 29<br />

60 35 36 26 23 21 19 20 24 27 37 35<br />

57.5 41 42 32 31 29 26 28 31 32 43 41<br />

55 53 54 46 75 46 40 43 72 48 54 53<br />

52.5 107 109 101 108 81 178 81 107 103 102 98<br />

50 138 141 137 150 216 610 211 148 136 139 136<br />

47.5 185 188 184 234 828 1356 799 238 184 182 179<br />

45 249 255 317 773 1581 2289 1553 744 314 253 247<br />

40 1491 1525 1767 2284 2947 3211 2937 2264 1747 1493 1457<br />

35 2993 3023 3193 3413 3576 3673 3595 3419 3210 3021 2984<br />

30 4016 4030 4119 4124 3980 3957 3987 4143 4161 4070 4047<br />

25 4567 4571 4570 4514 4348 4248 4352 4524 4615 4612 4600<br />

20 4851 4853 4835 4824 4761 4758 4793 4853 4871 4886 4880<br />

15 5187 5187 5194 5230 5260 5296 5308 5275 5258 5248 5235<br />

10 5565 5566 5574 5609 5611 5619 5626 5617 5614 5610 5598<br />

5 5723 5727 5722 5738 5723 5728 5735 5732 5738 5742 5730<br />

0.5 5757 5760 5753 5769 5753 5759 5769 5769 5774 5785 5771<br />

0 5766 5766 5766 5766 5766 5766 5766 5766 5766 5766 5766<br />

PAGE 3-LTL NUMBER 28146


LUMINAIRE TESTING LABORATORY, INC.<br />

SUSTAINING<br />

MEMBER<br />

of the<br />

IESNA<br />

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com<br />

MAXIMUM PLANE AND CONE PLOTS OF CANDELA<br />

150 180<br />

150<br />

5820<br />

120<br />

3880<br />

120<br />

1940<br />

HOUSE<br />

SIDE<br />

90<br />

90<br />

STREET<br />

SIDE<br />

60<br />

60<br />

30<br />

0 30<br />

VERTICAL PLANE THROUGH 85.0 DEGREES LATERAL<br />

LATERAL CONE THROUGH 0.5 DEGREES VERTICAL<br />

PAGE 4-LTL NUMBER 28146


LUMINAIRE TESTING LABORATORY, INC.<br />

SUSTAINING<br />

MEMBER<br />

of the<br />

IESNA<br />

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com<br />

FLUX DISTRIBUTION TABLE BASED ON THE IESNA LUMINAIRE CLASSIFICATION SYSTEM<br />

180°<br />

ZONE<br />

LUMINAIRE<br />

LUMENS<br />

FLUX<br />

% OF<br />

LUMINAIRE<br />

LUMENS<br />

100°<br />

90°<br />

80°<br />

UH<br />

UL<br />

BVH<br />

BH<br />

UH<br />

UL<br />

FVH<br />

FH<br />

100°<br />

90°<br />

80°<br />

FORWARD LIGHT 3482 50.0<br />

FL ( 0°-30°) 2038 29.3<br />

FM (30°-60°) 1436 20.6<br />

FH (60°-80°) 8 0.1<br />

FVH (80°-90°) 0 0.0<br />

60°<br />

FM<br />

BM 60°<br />

BACK LIGHT 3482 50.0<br />

BL<br />

FL<br />

BL ( 0°-30°) 2038 29.3<br />

BACK LIGHT<br />

FORWARD LIGHT<br />

BM (30°-60°) 1436 20.6<br />

30°<br />

30°<br />

BH (60°-80°) 8 0.1<br />

BVH (80°-90°) 0 0.0<br />

BACK<br />

FRONT<br />

UPLIGHT 0 0.0<br />

UL (90°-100°) 0 0.0<br />

UH (100°-180°) 0 0.0<br />

TRAPPED LIGHT NA NA<br />

BUG (Backlight, Uplight, Glare) Rating<br />

Asymmetrical Luminaire Types<br />

(Type I, II, III, IV)<br />

B3 U0 G0<br />

Quadrilateral Symmetrical Luminaire Types<br />

(Type V, Area Light)<br />

B3 U0 G0<br />

PAGE 5-LTL NUMBER 28146

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!