09.11.2014 Views

Installation/mounting instruction

Installation/mounting instruction

Installation/mounting instruction

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

OUT0V<br />

24V<br />

V<br />

I<br />

J5<br />

OUT0V<br />

24V<br />

V<br />

I<br />

J5<br />

C IN CBIN<br />

CCIN<br />

CDIN<br />

A<br />

C IN CBIN<br />

CCIN<br />

CDIN<br />

A<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

OUT0V<br />

24V<br />

V<br />

I<br />

J5<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J2<br />

J3<br />

C IN C IN C IN C IN<br />

A B C D<br />

J4<br />

OUT0V<br />

24V<br />

V<br />

I<br />

J5<br />

C IN CBIN<br />

CCIN<br />

CDIN<br />

A<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

<strong>Installation</strong> Instructions<br />

4DIX/24VAC<br />

Four Digital Input Expander Module (24 Vac/dc)<br />

Important: Retain this <strong>instruction</strong>s<br />

1 unpacking<br />

4DIX/24VAC <strong>Installation</strong><br />

Instructions TG200651<br />

2 STORING It is recommended that the installation<br />

should comply with the local electrical<br />

-10 °C<br />

(14 °F)<br />

+70 °C 0 %RH 95 %RH<br />

(158 °F) 0 <br />

safety installation practices (e.g.<br />

HSE Memorandum of Guidance on<br />

Electricity at Work Regulations 1989,<br />

USA National Electric Code).<br />

3 <strong>Installation</strong><br />

1 Dimensions<br />

2 Requirements<br />

13 mm (0.51”)<br />

a<br />

OUT0V<br />

24V<br />

V<br />

J5<br />

I<br />

J2<br />

C IN C IN A B<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J3<br />

C IN C IN C D<br />

J4<br />

82 mm (3.23”)<br />

b<br />

68 mm (2.68”) 50 mm (1.97”)<br />

The unit is UL rated as<br />

‘UL916 listed accessory to<br />

open energy management<br />

equipment’<br />

c<br />

-10 °C<br />

(14 °F)<br />

+50 °C<br />

(122 °F)<br />

0 <br />

0 %RH 90 %RH<br />

4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013 1


I<br />

J5<br />

V<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

V<br />

J5<br />

I<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

)<br />

*<br />

+<br />

,<br />

$ % & ' <br />

8<br />

! " # $ % & ' ! " #<br />

"8<br />

<br />

, 2<br />

! "# $ % & ' <br />

<br />

6 : 4 :<br />

)<br />

4DIX/24VAC<br />

installation Instructions<br />

3 <strong>Installation</strong> (continued)<br />

3<br />

Mount on DIN rail<br />

c<br />

a<br />

b<br />

4<br />

Specify Output Signal<br />

OUT0V<br />

24V<br />

Current<br />

I<br />

Voltage<br />

V<br />

5<br />

Switch off IQ<br />

<br />

IQ<br />

V<br />

V<br />

1<br />

J1<br />

J1<br />

J2<br />

IN C A<br />

IN C B<br />

C IN C<br />

C IN D<br />

J3<br />

I<br />

I<br />

Caution: This unit contains static sensitive devices. Suitable anti-static precautions<br />

should be taken throughout this operation to prevent damage to the unit.<br />

BS EN100015/1 Basic Specification: protection of electrostatic sensitive devices.<br />

6<br />

Set IQ input channel to Analogue, and to match 4DIX Output Signal Mode<br />

IQ Controller<br />

<strong>Installation</strong> Instructions<br />

V or I<br />

IQ<br />

IN<br />

C<br />

24 V<br />

analogue input<br />

channel<br />

J2 J3<br />

C IN C IN C IN C IN<br />

A B C D<br />

7<br />

Wire 4DIX to Controller<br />

Note that the controller’s 24 Vdc auxiliary supply or an external 24 Vac or dc supply should be used to supply the<br />

4DIX, not the current input 24 V (except for IQ3 with 4DIX in voltage mode - see below).<br />

either using IQ 24 Vdc auxiliary supply<br />

0V<br />

24VDC<br />

OUT 0V 24V<br />

4DIX<br />

OUT<br />

0V<br />

24V<br />

4DIX<br />

OUT<br />

0V<br />

24V<br />

24V<br />

24 V loop<br />

IQ1, IQ2, IQ4<br />

IN<br />

0 V<br />

24V (AUX)<br />

24 V loop<br />

IQ3<br />

0 (0 V)<br />

N (in) N<br />

24V<br />

+ (+24 V)<br />

24V (AUX)<br />

Cable size 0.5 to 2.5 mm 2 (20 to 14 AWG), Cu only<br />

Maximum distance from 4DIX to IQ:<br />

I mode=100 m (1090 yds), V mode=25 m (27 yds)<br />

Analogue input channel<br />

linked as table below<br />

4 DIX output<br />

mode linking<br />

IQ analogue input<br />

channel linking<br />

24 V current<br />

(max.)<br />

24 Vac 24 Vdc<br />

Current I<br />

External powered<br />

current I x<br />

90 mA 48 mA<br />

Voltage V Voltage V 48 mA 20 mA<br />

2 4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013


O<br />

I<br />

J5<br />

V<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

I<br />

J5<br />

V<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

<strong>Installation</strong> Instructions<br />

4DIX/24VAC<br />

3 <strong>Installation</strong> (continued)<br />

7<br />

Wire 4DIX to Controller (continued)<br />

Connecting 4DIX in voltage mode to IQ3. It can supply the<br />

attached single 4DIX in voltage mode<br />

4DIX in voltage mode<br />

24 V loop<br />

or using external 24 Vac/dc supply (e.g. IQeco)<br />

For IQeco check current available carefully, nearly always requires external supply<br />

J2 J3<br />

C IN C IN C IN C IN<br />

A B C D<br />

4DIX<br />

OUT<br />

0V<br />

0V<br />

24VDC<br />

OUT 0V 24V<br />

4DIX<br />

OUT<br />

0V<br />

24V<br />

24 V loop<br />

24V<br />

Note that external 24 V supply should be isolated or earthed<br />

(grounded) to IQ earth (ground); ensure correct polarity<br />

24V<br />

24V<br />

20 mA (max)<br />

IQ3<br />

0 (0 V)<br />

N (in) N<br />

+ (+24 V)<br />

~+ -<br />

PSU<br />

24 Vac/dc<br />

Universal input channel<br />

linked for voltage<br />

Connect signal, 0 V, and<br />

screen to controller as<br />

described above<br />

Check current carefully if using<br />

loop e.g. IQ3 input +(24 V) is<br />

unsuitable for daisy chaining<br />

24 V<br />

XRM<br />

XRM<br />

4DIX<br />

8<br />

I<br />

Ensure Equipment Input<br />

Power Supply is Switched<br />

off<br />

Power Supply<br />

Input Power<br />

Supply<br />

Equipment<br />

4DIX<br />

9<br />

HVAC Equipment<br />

volt free contacts<br />

Connect 4DIX to HVA Equipment<br />

C<br />

A<br />

IN<br />

C<br />

B<br />

IN<br />

C<br />

C<br />

IN<br />

C<br />

D<br />

IN<br />

4DIX<br />

J2 J3<br />

C IN C IN C IN C IN<br />

A B C D<br />

0V<br />

24VDC<br />

OUT 0V 24V<br />

Not suitable for counting inputs<br />

Cable size 0.5 to 2.5 mm 2<br />

(20 to 14 AWG), Cu only<br />

10<br />

Configure Controller<br />

It is recommended to use SET (software tool) for configuring the controller. SET is supplied with 4DIX<br />

strategy blocks for IQ1/2, IQ3/4, and IQeco controllers; the strategy is described in the 4DIX data sheet.<br />

If the SET strategy block is used it will set up both sensor scaling and strategy modules<br />

(a) Sensor scaling:<br />

For all IQ2 series controllers with firmware version 2.1 or greater, IQ3/4, or IQeco controllers, the<br />

appropriate SET Unique Sensor Reference from the following should be used:<br />

Voltage (V) mode: 4DIXV<br />

Current (I) mode: 4DIXI<br />

If not using SET, use sensor type scaling mode 5, characterise, with the appropriate scaling from the<br />

table below for all IQ2 series controllers of firmware version 2.1 or greater, IQ3/4, or IQeco controllers;<br />

for all other IQ controllers see Sensor Scaling Reference Card TB100521A.<br />

Mode Y E U L P I1 I2 O1 O2<br />

I 2 3 270 -1 2 0 20 0 268.25<br />

V 0 3 270 -1 2 0 10 0 268.25<br />

(b) Strategy: The strategy must be set up to decode the digital status from the analogue input. IQ3/4<br />

and IQeco are more responsive than IQ1/2 controllers and require more complex strategy. The SET<br />

4DIX strategy blocks can be used as examples.<br />

4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013 3


OUT0V<br />

24V<br />

V<br />

I<br />

J5<br />

C IN CBIN<br />

CCIN<br />

CDIN<br />

A<br />

0V<br />

24VDC<br />

D<br />

C<br />

B<br />

A<br />

J4<br />

C A<br />

IN<br />

IN<br />

A<br />

B<br />

C<br />

D<br />

OK<br />

16 17 18 19 20<br />

V<br />

TX RX LAN<br />

24V<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

1 2345678910<br />

J5<br />

J4<br />

I<br />

DP<br />

B<br />

A<br />

C<br />

V D<br />

24VDC<br />

0V<br />

OUT 24V<br />

0V<br />

24V<br />

OK<br />

TX RX<br />

12345678910<br />

LAN<br />

4DIX/24VAC<br />

installation Instructions<br />

3 <strong>Installation</strong> (continued)<br />

11<br />

Close<br />

Switch on IQ<br />

Switch on HVAC Equipment<br />

12 13<br />

Panel<br />

Input Power Supply<br />

O<br />

IQ<br />

O<br />

I<br />

Power Supply<br />

I<br />

The unit is UL rated<br />

as ‘UL916 listed<br />

accessory to open<br />

energy management<br />

equipment’<br />

Input Power<br />

Supply<br />

Equipment<br />

4DIX<br />

14<br />

Check 4DIX operation<br />

IQ<br />

DP<br />

HVAC<br />

Equipment<br />

C C IN C IN<br />

B C D<br />

4DIX<br />

A<br />

B<br />

C<br />

D<br />

16 17 18 19 20<br />

V<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

4 DISPOSAL<br />

WEEE Directive :<br />

At the end of their useful life the packaging<br />

and product should be disposed of by a<br />

suitable recycling centre.<br />

Do not dispose of with normal household waste.<br />

Do not burn.<br />

Please send any comments about this or any other Trend technical publication to techpubs@trendcontrols.com<br />

© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls<br />

Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.<br />

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation<br />

to notify any person of such revisions or changes.<br />

Trend Control Systems Limited<br />

Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com<br />

Trend Control System USA<br />

6670 185 th Avenue NE, Redmond, Washington 98052, USA. Tel:(425) 869-3900 Fax:(425) 869-8445 www.trend-americas.com<br />

4 4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!