Installation/mounting instruction
Installation/mounting instruction
Installation/mounting instruction
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OUT0V<br />
24V<br />
V<br />
I<br />
J5<br />
OUT0V<br />
24V<br />
V<br />
I<br />
J5<br />
C IN CBIN<br />
CCIN<br />
CDIN<br />
A<br />
C IN CBIN<br />
CCIN<br />
CDIN<br />
A<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
OUT0V<br />
24V<br />
V<br />
I<br />
J5<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J2<br />
J3<br />
C IN C IN C IN C IN<br />
A B C D<br />
J4<br />
OUT0V<br />
24V<br />
V<br />
I<br />
J5<br />
C IN CBIN<br />
CCIN<br />
CDIN<br />
A<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
<strong>Installation</strong> Instructions<br />
4DIX/24VAC<br />
Four Digital Input Expander Module (24 Vac/dc)<br />
Important: Retain this <strong>instruction</strong>s<br />
1 unpacking<br />
4DIX/24VAC <strong>Installation</strong><br />
Instructions TG200651<br />
2 STORING It is recommended that the installation<br />
should comply with the local electrical<br />
-10 °C<br />
(14 °F)<br />
+70 °C 0 %RH 95 %RH<br />
(158 °F) 0 <br />
safety installation practices (e.g.<br />
HSE Memorandum of Guidance on<br />
Electricity at Work Regulations 1989,<br />
USA National Electric Code).<br />
3 <strong>Installation</strong><br />
1 Dimensions<br />
2 Requirements<br />
13 mm (0.51”)<br />
a<br />
OUT0V<br />
24V<br />
V<br />
J5<br />
I<br />
J2<br />
C IN C IN A B<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J3<br />
C IN C IN C D<br />
J4<br />
82 mm (3.23”)<br />
b<br />
68 mm (2.68”) 50 mm (1.97”)<br />
The unit is UL rated as<br />
‘UL916 listed accessory to<br />
open energy management<br />
equipment’<br />
c<br />
-10 °C<br />
(14 °F)<br />
+50 °C<br />
(122 °F)<br />
0 <br />
0 %RH 90 %RH<br />
4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013 1
I<br />
J5<br />
V<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
V<br />
J5<br />
I<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
)<br />
*<br />
+<br />
,<br />
$ % & ' <br />
8<br />
! " # $ % & ' ! " #<br />
"8<br />
<br />
, 2<br />
! "# $ % & ' <br />
<br />
6 : 4 :<br />
)<br />
4DIX/24VAC<br />
installation Instructions<br />
3 <strong>Installation</strong> (continued)<br />
3<br />
Mount on DIN rail<br />
c<br />
a<br />
b<br />
4<br />
Specify Output Signal<br />
OUT0V<br />
24V<br />
Current<br />
I<br />
Voltage<br />
V<br />
5<br />
Switch off IQ<br />
<br />
IQ<br />
V<br />
V<br />
1<br />
J1<br />
J1<br />
J2<br />
IN C A<br />
IN C B<br />
C IN C<br />
C IN D<br />
J3<br />
I<br />
I<br />
Caution: This unit contains static sensitive devices. Suitable anti-static precautions<br />
should be taken throughout this operation to prevent damage to the unit.<br />
BS EN100015/1 Basic Specification: protection of electrostatic sensitive devices.<br />
6<br />
Set IQ input channel to Analogue, and to match 4DIX Output Signal Mode<br />
IQ Controller<br />
<strong>Installation</strong> Instructions<br />
V or I<br />
IQ<br />
IN<br />
C<br />
24 V<br />
analogue input<br />
channel<br />
J2 J3<br />
C IN C IN C IN C IN<br />
A B C D<br />
7<br />
Wire 4DIX to Controller<br />
Note that the controller’s 24 Vdc auxiliary supply or an external 24 Vac or dc supply should be used to supply the<br />
4DIX, not the current input 24 V (except for IQ3 with 4DIX in voltage mode - see below).<br />
either using IQ 24 Vdc auxiliary supply<br />
0V<br />
24VDC<br />
OUT 0V 24V<br />
4DIX<br />
OUT<br />
0V<br />
24V<br />
4DIX<br />
OUT<br />
0V<br />
24V<br />
24V<br />
24 V loop<br />
IQ1, IQ2, IQ4<br />
IN<br />
0 V<br />
24V (AUX)<br />
24 V loop<br />
IQ3<br />
0 (0 V)<br />
N (in) N<br />
24V<br />
+ (+24 V)<br />
24V (AUX)<br />
Cable size 0.5 to 2.5 mm 2 (20 to 14 AWG), Cu only<br />
Maximum distance from 4DIX to IQ:<br />
I mode=100 m (1090 yds), V mode=25 m (27 yds)<br />
Analogue input channel<br />
linked as table below<br />
4 DIX output<br />
mode linking<br />
IQ analogue input<br />
channel linking<br />
24 V current<br />
(max.)<br />
24 Vac 24 Vdc<br />
Current I<br />
External powered<br />
current I x<br />
90 mA 48 mA<br />
Voltage V Voltage V 48 mA 20 mA<br />
2 4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013
O<br />
I<br />
J5<br />
V<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
I<br />
J5<br />
V<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
<strong>Installation</strong> Instructions<br />
4DIX/24VAC<br />
3 <strong>Installation</strong> (continued)<br />
7<br />
Wire 4DIX to Controller (continued)<br />
Connecting 4DIX in voltage mode to IQ3. It can supply the<br />
attached single 4DIX in voltage mode<br />
4DIX in voltage mode<br />
24 V loop<br />
or using external 24 Vac/dc supply (e.g. IQeco)<br />
For IQeco check current available carefully, nearly always requires external supply<br />
J2 J3<br />
C IN C IN C IN C IN<br />
A B C D<br />
4DIX<br />
OUT<br />
0V<br />
0V<br />
24VDC<br />
OUT 0V 24V<br />
4DIX<br />
OUT<br />
0V<br />
24V<br />
24 V loop<br />
24V<br />
Note that external 24 V supply should be isolated or earthed<br />
(grounded) to IQ earth (ground); ensure correct polarity<br />
24V<br />
24V<br />
20 mA (max)<br />
IQ3<br />
0 (0 V)<br />
N (in) N<br />
+ (+24 V)<br />
~+ -<br />
PSU<br />
24 Vac/dc<br />
Universal input channel<br />
linked for voltage<br />
Connect signal, 0 V, and<br />
screen to controller as<br />
described above<br />
Check current carefully if using<br />
loop e.g. IQ3 input +(24 V) is<br />
unsuitable for daisy chaining<br />
24 V<br />
XRM<br />
XRM<br />
4DIX<br />
8<br />
I<br />
Ensure Equipment Input<br />
Power Supply is Switched<br />
off<br />
Power Supply<br />
Input Power<br />
Supply<br />
Equipment<br />
4DIX<br />
9<br />
HVAC Equipment<br />
volt free contacts<br />
Connect 4DIX to HVA Equipment<br />
C<br />
A<br />
IN<br />
C<br />
B<br />
IN<br />
C<br />
C<br />
IN<br />
C<br />
D<br />
IN<br />
4DIX<br />
J2 J3<br />
C IN C IN C IN C IN<br />
A B C D<br />
0V<br />
24VDC<br />
OUT 0V 24V<br />
Not suitable for counting inputs<br />
Cable size 0.5 to 2.5 mm 2<br />
(20 to 14 AWG), Cu only<br />
10<br />
Configure Controller<br />
It is recommended to use SET (software tool) for configuring the controller. SET is supplied with 4DIX<br />
strategy blocks for IQ1/2, IQ3/4, and IQeco controllers; the strategy is described in the 4DIX data sheet.<br />
If the SET strategy block is used it will set up both sensor scaling and strategy modules<br />
(a) Sensor scaling:<br />
For all IQ2 series controllers with firmware version 2.1 or greater, IQ3/4, or IQeco controllers, the<br />
appropriate SET Unique Sensor Reference from the following should be used:<br />
Voltage (V) mode: 4DIXV<br />
Current (I) mode: 4DIXI<br />
If not using SET, use sensor type scaling mode 5, characterise, with the appropriate scaling from the<br />
table below for all IQ2 series controllers of firmware version 2.1 or greater, IQ3/4, or IQeco controllers;<br />
for all other IQ controllers see Sensor Scaling Reference Card TB100521A.<br />
Mode Y E U L P I1 I2 O1 O2<br />
I 2 3 270 -1 2 0 20 0 268.25<br />
V 0 3 270 -1 2 0 10 0 268.25<br />
(b) Strategy: The strategy must be set up to decode the digital status from the analogue input. IQ3/4<br />
and IQeco are more responsive than IQ1/2 controllers and require more complex strategy. The SET<br />
4DIX strategy blocks can be used as examples.<br />
4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013 3
OUT0V<br />
24V<br />
V<br />
I<br />
J5<br />
C IN CBIN<br />
CCIN<br />
CDIN<br />
A<br />
0V<br />
24VDC<br />
D<br />
C<br />
B<br />
A<br />
J4<br />
C A<br />
IN<br />
IN<br />
A<br />
B<br />
C<br />
D<br />
OK<br />
16 17 18 19 20<br />
V<br />
TX RX LAN<br />
24V<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
1 2345678910<br />
J5<br />
J4<br />
I<br />
DP<br />
B<br />
A<br />
C<br />
V D<br />
24VDC<br />
0V<br />
OUT 24V<br />
0V<br />
24V<br />
OK<br />
TX RX<br />
12345678910<br />
LAN<br />
4DIX/24VAC<br />
installation Instructions<br />
3 <strong>Installation</strong> (continued)<br />
11<br />
Close<br />
Switch on IQ<br />
Switch on HVAC Equipment<br />
12 13<br />
Panel<br />
Input Power Supply<br />
O<br />
IQ<br />
O<br />
I<br />
Power Supply<br />
I<br />
The unit is UL rated<br />
as ‘UL916 listed<br />
accessory to open<br />
energy management<br />
equipment’<br />
Input Power<br />
Supply<br />
Equipment<br />
4DIX<br />
14<br />
Check 4DIX operation<br />
IQ<br />
DP<br />
HVAC<br />
Equipment<br />
C C IN C IN<br />
B C D<br />
4DIX<br />
A<br />
B<br />
C<br />
D<br />
16 17 18 19 20<br />
V<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
4 DISPOSAL<br />
WEEE Directive :<br />
At the end of their useful life the packaging<br />
and product should be disposed of by a<br />
suitable recycling centre.<br />
Do not dispose of with normal household waste.<br />
Do not burn.<br />
Please send any comments about this or any other Trend technical publication to techpubs@trendcontrols.com<br />
© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls<br />
Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.<br />
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation<br />
to notify any person of such revisions or changes.<br />
Trend Control Systems Limited<br />
Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com<br />
Trend Control System USA<br />
6670 185 th Avenue NE, Redmond, Washington 98052, USA. Tel:(425) 869-3900 Fax:(425) 869-8445 www.trend-americas.com<br />
4 4DIX/24VAC Four Digital Input Expander Module (24 Vac/dc) TG200651 Issue 4, 20/05/2013