(3) When two working places belowground have approached within three metres<br />

<strong>of</strong> each other, the blaster shall not fire any shot in any one <strong>of</strong> the said workings unless all<br />

persons have been withdrawn from the other working place and the same has been so<br />

fenced <strong>of</strong>f as to prevent persons inadvertently coming in direct line <strong>of</strong> the shot.<br />

(4) In any mine to which regulation 142 appliles, the following provisions shall<br />

have effect, namely :-<br />

(a) Notwithstanding anything contained in the regulations, no shot shall be<br />

stemmed or fired by any person who does not hold either a Manager’s<br />

Certificate, or Foreman’s or Mate’s Certificate together with a Gas-testing<br />

Certificate.<br />

(b) Where more shots than one are charged for firing, the shots shall be fired<br />

simultaneously. No delay-action detonator shall be used, except with the<br />

previous permission in writing <strong>of</strong> the Chief Inspector and subject to such<br />

conditions as he may specify therein.<br />

(c) If in ventilating district, presence <strong>of</strong> inflammable gas is detected in any<br />

place, no shothole shall be charged, stemmed or fired in that place or in<br />

any other place situated on its return side till such place has been cleared<br />

<strong>of</strong> gas and declared safe.<br />

(d) Immediately before charging a shothole or a round <strong>of</strong> shotholes, and again<br />

before firing the shots, the blaster shall carefully test for inflammable gas<br />

at all places within a radius <strong>of</strong> 20 metres <strong>of</strong> the place <strong>of</strong> firing.<br />

166. Inspections after shotfiring. – (1) After4 a shot has been fired, no person other than<br />

the blaster or any other competent person holding a Manger’s or Foreman’s Certificate<br />

appointed for the purpose by the Manager shall enter, or allow any other person to enter,<br />

the place until the area is free from dust, smoke or fumes. The blaster or other competent<br />

person shall, before any other person enters the place, make a careful examination and<br />

with his assistants, if any, make the place safe. No other person shall enter the place and<br />

where guards have been posted, they shall not be withdrawn until the examination has<br />

been made and the place has been declared to be safe in all respect. In the case <strong>of</strong><br />

opencast workings, after shots have been fired, an all clear signal shall be given except in<br />

the case <strong>of</strong> a misfire.<br />

(2) After shots have been fired, all persons engaged in clearing mineral, rock or<br />

debris shall look for unexploded cartridges and detonators. If such a cartridge and<br />

detonator is found, it shall be removed and shall as soon as possible be handed over to a<br />

blaster or other <strong>of</strong>ficial.<br />

167. Misfires. – (1) The number <strong>of</strong> shots which explode shall, unless shots are fired<br />

electrically or by means <strong>of</strong> an igniter cord, be counted by the blaster and another<br />

competent person authorized for the purpose; and unless it is certain that all the shots<br />

have been exploded, no person shall re-enter or be permitted to re-enter the place until 30<br />

minutes after the firing <strong>of</strong> shots :