08.11.2014 Views

Product Guide - Lantech Communications Global Inc

Product Guide - Lantech Communications Global Inc

Product Guide - Lantech Communications Global Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Lantech</strong> TM<br />

2011<br />

<strong>Product</strong><br />

<strong>Guide</strong>


Contents<br />

iAbout <strong>Lantech</strong><br />

About <strong>Lantech</strong><br />

Industrial Solutions<br />

Rail Train System<br />

Building Automation<br />

Factory Automation<br />

Petroleum Industry<br />

Bus Network<br />

Tunnel Traffic Monitoring<br />

Wind Power Monitoring<br />

Power-Substation<br />

Offshore Platform<br />

Cruise Liner<br />

Water Treatment Plant<br />

ISP Infrastructure<br />

About <strong>Lantech</strong><br />

With a long background in IP Ethernet products, <strong>Lantech</strong> brings the best network solutions for<br />

Industrial and IP networks to the marketplace. The <strong>Lantech</strong> group is devoted to providing feature rich,<br />

high-quality networking solutions with outstanding service and support to our world-wide partners.<br />

<strong>Lantech</strong>’s core competency is centered around our network software and hardware, which allows for<br />

the seamless delivery of a variety of applications and services in diverse network environments.<br />

<strong>Lantech</strong> products are integrated with X-Ring, our proprietary auto network recovery protocol, and<br />

<strong>Lantech</strong>-View, a Windows utility for monitoring and configuring multiple switches at one time. <strong>Lantech</strong><br />

is committed to providing our partners with the products, service and support necessary to help<br />

promote our brand in the marketplace.<br />

<strong>Lantech</strong> offers a complete family of commercial and industrial grade networking products in support<br />

of the global transition to all Ethernet services. <strong>Lantech</strong> products and solutions provide for the delivery<br />

of universal Ethernet services across various markets and applications including:<br />

i<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

Technology<br />

<strong>Lantech</strong>-View Lite 13<br />

<strong>Lantech</strong>-View Pro 14<br />

Pro-Ring System 15<br />

Pro-Ring II System 17


Industrial Ethernet Switches<br />

Industrial EN50155 Switches<br />

Industrial IEC 61850-3 Switches<br />

Industrial DNV Type Switches<br />

Industrial Managed Switches<br />

Industrial PoE Switches<br />

Industrial Smart-Ring Switches<br />

Industrial Entry Switches<br />

Industrial Converters Series<br />

Universal Redundant Fiber Controller<br />

Industrial Wireless Access Point<br />

Business Ethernet Switches<br />

Central Managed Switches<br />

Smart Switches<br />

PoE Series<br />

Serial Devices<br />

Fiber Converters<br />

MiniGBIC<br />

Power and Accessories<br />

19<br />

21<br />

23<br />

25<br />

27<br />

29<br />

30<br />

31<br />

32<br />

33<br />

35<br />

37<br />

38<br />

39<br />

41<br />

42<br />

43<br />

Transportation Power and Utilities Maritime / Ship / Offshore Platform<br />

Oil and Gas Telecom and ISP / WISP Surveillance<br />

Building Automation and Security<br />

Process / Manufacturing Automation<br />

Mining Rail Train EN50155 Others<br />

<strong>Lantech</strong> products are distributed worldwide. We provide high quality products with<br />

customer-centered services from our sales offices located in Taiwan, United States, Germany, and<br />

Korea. By combining our outstanding products and services with knowledgeable and respected<br />

channel partners, <strong>Lantech</strong> is able to provide a significant price-performance value to any Industrial or<br />

IP network.<br />

<strong>Lantech</strong> products are successfully transporting Ethernet services around the globe, including networks<br />

at The Taiwan Post Office, In-store Broadcasting Networks, Stanford University, CNN, Universität<br />

Würzburg (The University of Wurzburg), Korea U-city FTTX, Korea’s Subway System, Thailand’s<br />

Subway System, Japan’s High-speed Railway, Israel’s wireless backhaul network and many more.<br />

ii


Rail Train System<br />

Challenges: The current conventional train<br />

communication networks (TCN) are facing several<br />

challenges to improve the service including the<br />

limitation of bandwidth and integration. The devices in<br />

railway systems often operate in a narrow and harsh<br />

environment with unique requirements. For example,<br />

severe air pollution, vibration, shock and EMC are<br />

commonly seen.<br />

Entertainment System<br />

Digital Display<br />

Wireless Service<br />

To interact with passengers fluently, the<br />

Connected with the control center, the digital<br />

Rail train provides Wi-Fi hotspot for passengers<br />

Industrial Solutions<br />

entertainment system requires Ethernet<br />

network with high performances. Switches<br />

which support IGMP protocol are able to satisfy<br />

the requirement with the multicast ability.<br />

display is able to show the news and passenger<br />

information immediately.<br />

to connect on the Internet, even during the high<br />

speed moving status.<br />

Railway transportation has been becoming major trend for eco-friendly<br />

and highly efficient transportation way, the major challenges are<br />

security and control management. Train Communication Networks<br />

consist of four elements- Security, Information, Control and Passenger<br />

communications, in which every part is essential to make train cruise<br />

safe and sound. Vibration, EMI/RFI, pollutants, input voltage ripple and<br />

surge are the issues often found in the rail train network.<br />

<strong>Product</strong> Selections<br />

IES-2208F-67 (P.19)<br />

The EN50155 standard, which is “Railways Applications Electronic<br />

Equipment Used on Rolling Stock”, is commonly adopted by many<br />

countries and electronics manufacturers. Electronic equipment shall be<br />

designed and manufactured to meet the full performance specification<br />

requirement for the selected categories such as ambient temperature,<br />

shock and vibration, relative humidity, atmospheric pollutants,<br />

electrical service conditions, etc. <strong>Lantech</strong> provides a series of models<br />

which is fully compliant with EN50155 standard.<br />

IPES-0008-4-M12 (P.19)<br />

IWP-2000-68 (P.33)<br />

P1


Challenges: Historically, building owners in the<br />

market for a new Building Management Systems<br />

(BMS) have been forced to choose between one of<br />

several proprietary equipment manufacturers.<br />

Upon the purchase, the building owner is locked in<br />

to one product for a considerable amount of time<br />

or has to change the whole system which is costly<br />

in terms of time and money.<br />

Building Automation<br />

Ethernet<br />

IES-1204FT<br />

Web Server<br />

Email,<br />

Trap Events<br />

RS-485<br />

IDS-2101F<br />

IES-1204FT<br />

<strong>Lantech</strong><br />

LonTalk<br />

Controller<br />

Lighting<br />

Controller<br />

Pro-Ring < 10ms<br />

PLC<br />

(Programmable<br />

Logic Controller)<br />

Ventilation<br />

Controller<br />

<strong>Lantech</strong><br />

Boiler<br />

Controller<br />

IES-1204FT<br />

IDS-2101F<br />

Central<br />

Plant<br />

Controller<br />

PLC<br />

(Programmable<br />

Logic Controller)<br />

Package<br />

Unit<br />

Controller<br />

Computer<br />

Workstation<br />

Heating<br />

Controller<br />

Industrial Solutions<br />

<strong>Product</strong> Selections<br />

IES-1005T (P.29)<br />

Elevator Control<br />

As the most important vertical<br />

transport equipment that<br />

Lighting Control<br />

To save the energy, the lighting in<br />

a building should be adjusted<br />

Centralized Air<br />

Conditioner<br />

Not only keeping temperature<br />

IES-1204FT (P.29)<br />

efficiently moves people or goods<br />

based on the sun’s position<br />

constantly, centralized air<br />

between floors, elevator must<br />

throughout the day, based on the<br />

conditioner may clean the air of<br />

under total control.<br />

season, and building location and<br />

whole building with sophisticated<br />

facade.<br />

filtering system.<br />

Over the last few years there has been a move away from manufacturers proprietary<br />

communication protocols towards more open protocols such as TCP/IP and BACnet®/IP. The use<br />

of TCP/IP for BMS system communications has brought about increased choice in selecting<br />

products from different vendors in the same BMS system and reducing the associated cabling and<br />

network hardware costs.<br />

IDS-2101F (P.39)<br />

For any Building network it is important to use switches with an appropriate technical<br />

specification to ensure high level network reliability and to meet necessary installation<br />

requirements. Normally BMS equipment is fitted in compact wall mounted control cabinets that<br />

are distributed around the building, with most devices being DIN Rail mounted and typically<br />

requiring a low voltage power feed of 24VAC or 24VDC (varies by Country). For cable runs which<br />

exceed the 100 meter limitation of Cat5e or for links between different buildings, a fiber optic link<br />

is the ideal solution.<br />

IDS-2204 (P.39)<br />

P2


Factory Automation<br />

Challenges: The most dynamic and challenging part for<br />

factory automation floor network is redundancy and<br />

real-time. Factory automation needs to be absolutely<br />

accurate because any interruption or delay could result<br />

in huge amount of lost, especially when the operation<br />

is non-stop, 7/24/365. On the other hand, to satisfy the<br />

rapid changing industry environment, manufacturing<br />

process must have high flexibility than before.<br />

Industrial Solutions<br />

Ethernet<br />

RS-485<br />

IES-2208C<br />

Web Server<br />

Email,<br />

Trap Events<br />

Human Interface Device<br />

Computer Workstation<br />

Pro-Ring < 10ms<br />

IES-2208C<br />

IES-2208C<br />

Conveyor system<br />

The mechanical handling equipment<br />

moves materials from one location to<br />

another, especially useful for the<br />

IDS-2102<br />

IDS-2102<br />

<strong>Lantech</strong><br />

PLC<br />

Robotic<br />

Arm<br />

Robotic Arm<br />

The programmable robot manipulator<br />

is designed to perform any desired<br />

task such as welding, gripping,<br />

transportation of heavy or bulky<br />

materials. It’s quick, efficient, and<br />

popular in the material handling and<br />

packaging industries.<br />

PLC<br />

<strong>Lantech</strong><br />

Industrial<br />

Motors/Drives<br />

I/O Devices<br />

Robotic<br />

Arm<br />

spinning etc., depending on the<br />

application. The robot arm in<br />

automotive assembly lines performs a<br />

variety of tasks with great accuracy.<br />

In factory automation applications, the most common structure consists of PLC, DCS, and<br />

SCADA. Based on IP protocol, managers are able to control equipments and transmit data to<br />

SCADA, where connects with database and then generate statistic data for monitoring the<br />

operating status. <strong>Lantech</strong>’s Pro-Ring system provides the reliable Ethernet network among<br />

these devices and software with the fastest recovery time if failure. As the equipments are all<br />

utilizing IP protocol and connect to the Ethernet, it’s easier to integrate and change<br />

configuration through Internet.<br />

<strong>Product</strong> Selections<br />

IES-2208C (P.25)<br />

Due to the requirement of absolute accurate data transmission, there is a huge need for real<br />

time protocols in factory automation applications, including ProfiNet by Siemens, EthernetIP by<br />

Rockwell, and ModBUS by Schneider. The real time protocols were developed by the need of<br />

PLC’s connecting with robotic arms, conveyor belts and other automation devices for factory<br />

automation. This created the need for switches to be compatible with real time protocols. By<br />

collocating with Ethernet switches, managers are able to monitor the status, detect the failure,<br />

and solve the problem immediately.<br />

IDS-2102 (P.39)<br />

*All rights of brand names of Siemens, Rockwell, and Schneider mentioned herein belong to their respective holders.<br />

P3


<strong>Lantech</strong><br />

Challenges: The whole petroleum industrial system<br />

starts from wellhead and ends with the refine system.<br />

Between wellhead and refine factory is the distributed<br />

system such as pump station and pipeline. Operating<br />

environments of this industry are full of explode-able<br />

materials which may cause tremendous damages, no<br />

matter at which part of production processes.<br />

Petroleum Industry<br />

Oil wellhead process<br />

Automated oil tank monitoring system is one of the<br />

most important elements in oil wellhead process. This<br />

Oil transmission<br />

Oil is transmitted via pipelines and pump stations. In<br />

order to ensure high and uniform flow of oil, pump<br />

Oil refining process<br />

It is consist of several complicated and a large variety<br />

of equipments/devices and need to be deployed by<br />

Industrial Solutions<br />

system combines with data transferring, video<br />

stations are needed at regular intervals and pipelines<br />

distributed control system (DCS). DCS systems allow<br />

recording, and voice, which requires huge bandwidth,<br />

must be under control. For example, to keep the<br />

the entire system of controllers to be connected by<br />

real-time reaction, and reliable durability.<br />

pressure in the pipeline at 50 bar pressure, managers<br />

networks for communication and monitoring.<br />

must monitor the status continuously.<br />

Human Interface Device<br />

Computer Workstation<br />

IES-2307C<br />

UL<br />

C1D2<br />

IES-2307C<br />

IPES-0005T-4<br />

IP Phone<br />

<strong>Product</strong> Selections<br />

IES-2307C (P.25)<br />

Pro-Ring


Bus Network<br />

Challenges: The primary applications for Bus Network<br />

consist of Surveillance, Smart Ticketing and Video on<br />

Demand. One of the key issues for BUS network is the<br />

24VDC or lower power input, which is not enough for<br />

standard 802.3af PoE switches or standard Ethernet<br />

switches. The other challenges like shock, vibration<br />

and limited spaces are also needed to cope with.<br />

IWP-1000<br />

PoE<br />

UTP<br />

Industrial Solutions<br />

NVR<br />

IP Camera<br />

IPES-0008-4<br />

Digital Infomation Display<br />

IES-0216C<br />

Ticket System<br />

Low voltage<br />

when engine starts<br />

IP camera<br />

It is one of the most important<br />

NVR<br />

It is a storage device collecting video<br />

<strong>Product</strong> Selections<br />

When bus starts engine from battery,<br />

it will draw a lot of current hence to<br />

devices and is able to record video<br />

24/7/365. PoE cameras normally<br />

files and integrated with powerful<br />

surveillance software, manager will<br />

IES-0216C (P.30)<br />

make the voltage low and cause<br />

need 48VDC power supply with<br />

get notice when any abnormal event<br />

on-board devices not able to operate.<br />

switches that fully comply with the<br />

happens through it.<br />

PoE standard to be fed power by<br />

Ethernet cable.<br />

<strong>Lantech</strong> industrial switches are able to run with voltage as low as 9Vdc and offers the series of<br />

PoE switch accepting 24V DC and boost to 48VDC for feeding power to surveillance system of<br />

moving vehicles. The 24V/48V DC <strong>Lantech</strong> PoE switch series are able to work in harsh<br />

environment and provide up to 15.4w/port@48VDC to PDs. They are the best choice to<br />

construct a surveillance system for moving vehicles such as bus or railcar. Constructers don’t<br />

have to install an external booster, which may need extra cost and space.<br />

IPES-0008-4 (P.27)<br />

To meet with the critical network environment of a moving bus, the switch is protected by IP30<br />

housing and tested under extensive industrial EMI and safety standards. It also passed stability<br />

tests including free fall, shock and vibration. The wide operating temperature range of -40°C to<br />

75°C ensures the durability as well.<br />

IWP-1000 (P.33)<br />

<strong>Lantech</strong> PoE models comply with most of the leading PoE IP camera brands in the market, such<br />

as AXIS, MOBOTIX, Sony, Panasonic, Samsung, NICE etc which ensures the stability when<br />

construct an Ethernet network for the bus surveillance system.<br />

*All rights of brand names of AXIS, MOBOTIX, Sony, Panasonic, Samsung, NICE mentioned herein belong to their respective holders.<br />

P5


Challenges: Undoubtedly, the operating environment<br />

of tunnel is harsh coping with humid with extreme<br />

temperature and pollutants in a tunnel generating by<br />

cars and other moving vehicles, the vibration caused by<br />

moving vehicles is another challenge for network<br />

devices. Thus, a reliable Ethernet network is the top<br />

priority for tunnel traffic monitor application.<br />

Tunnel Traffic Monitoring<br />

IP phone<br />

IP phone is installed between<br />

selected intervals and is a vital<br />

tool when there’s an emergency<br />

in a tunnel.<br />

Ventilation fan<br />

Due to the pollutant and heat<br />

caused during driving, the tunnel<br />

must have these fans to maintain<br />

the air circulation.<br />

Variable message sign<br />

It shows immediate traffic status,<br />

speed restriction, or weather<br />

forecast. The message is<br />

controlled by control center<br />

remotely via Ethernet network.<br />

To Upper Layer Switches via Dual Homing<br />

Industrial Solutions<br />

HEED<br />

YOUR<br />

SPEED<br />

! O O X<br />

Tunnel A<br />

Tunnel B<br />

X-Ring Group 1<br />

O O X<br />

!<br />

HEED<br />

YOUR<br />

SPEED<br />

X-Ring Group 2,3<br />

IP Phone<br />

Traffic Sign<br />

Fan<br />

Controller<br />

VMS<br />

IP Cam<br />

<strong>Product</strong> Selections<br />

<strong>Lantech</strong> industrial switches are able to sustain in tunnel projects by providing our high-quality<br />

industrial switches with redundancy of network recovery scheme. The Ethernet-based network<br />

connects IP CCTV, audio PA, telephones, VMS (Variable Message Signs), lighting control and<br />

ventilation fans (SCADA system) and also some traffic control systems for management remotely.<br />

IES-2208F (P.25)<br />

<strong>Lantech</strong> managed switch support full management functions, including the IGMP protocol for<br />

multicasting, which is important for video transmission. To against the harsh environment,<br />

<strong>Lantech</strong> models operate well in the range from -40°C to 75°C and also pass several stability and<br />

safety test including vibration, free fall, shock, EMI and EMC, to meet the difficult tunnel<br />

environment.<br />

IPES-2208C (P.27)<br />

<strong>Lantech</strong> products help to construct a highly reliable network connection by Pro-Ring system,<br />

which is the most important factor for an efficient traffic monitoring system, under the harsh<br />

environment in tunnel.<br />

P6


Wind Power Monitoring<br />

Challenges: Long distance transmission between wind<br />

turbines with stable and no data loss is one of the<br />

major requirements in a wind power park. Doing<br />

maintenance without interrupting network connection<br />

is not easy, on the other hand. Harsh environment<br />

requires hardened network devices to overcome wide<br />

temperature range and strong vibration caused by<br />

wind as well as electrical interference.<br />

Industrial Solutions<br />

Wind turbine tower<br />

The control box, which is at the top of<br />

each wind turbine tower, comprises a<br />

PLC, power inverter, control board, and<br />

I/O device. There’re sensors which collect<br />

wind speed, wind direction, shaft rotation<br />

speed, and numerous other factors and<br />

then transfer data to the PLC.<br />

Email,<br />

Trap Events<br />

Web Server<br />

Human Interface Device<br />

Computer Workstation<br />

Pro-Ring < 10ms<br />

<strong>Lantech</strong> provides a complete Ethernet solution with IES-2307C, the managed industrial switch,<br />

and IFR-0202, the universal redundant fiber controllers. The wind turbines are connected with<br />

each other via optical fibers, providing the long distance transmission with stable quality.<br />

Several wind turbine towers are connected in a ring topology, where <strong>Lantech</strong> Pro-ring system<br />

provides the fastest redundant protection to prevent network interruption. Integrated with<br />

unique universal redundant fiber controllers, the fiber ring will be more reliable when facing<br />

multiple switches’ power off. As for maintenance, it will be able to maintain one switch and<br />

keep the connection active.<br />

All <strong>Lantech</strong> industrial products are passed several tests such as shock, vibration and free fall and<br />

meet industrial EMI and EMC standards. The IP30 case and industrial grade components help to<br />

overcome the harsh operating environment in the wind power park.<br />

<strong>Product</strong> Selections<br />

IES-2307C (P.25)<br />

IFR-0202 (P.32)<br />

P7


Challenges: The Ethernet network is one of the most<br />

significant infrastructure components used to<br />

construct the smart grid and the quality of network is<br />

the key factor that affects the operating performance.<br />

The switches must overcome the harsh environment<br />

with strong EMI and support the real time protocol for<br />

seamless data transmission.<br />

Power-Substation<br />

IED<br />

Via an Ethernet network, the<br />

Intelligent Electronic Devices (IEDs)<br />

are able to connect with a RTU and<br />

satisfy all management needs.<br />

RTU<br />

The Remote Terminal Unit (RTU)<br />

collects and sends data to a central<br />

control room, which may be located a<br />

long way from the substations which<br />

make up the Transmission /<br />

Distribution system.<br />

Industrial Solutions<br />

IP Camera<br />

RTU<br />

IES-2224-2P<br />

Human Interface Device<br />

Computer Workstation<br />

IP Phone<br />

IES-2224-2P<br />

Pro-Ring


Offshore Platform<br />

Challenges: The challenges of offshore platform<br />

network application include coping with harsh<br />

environmental conditions that has extreme operating<br />

temperatures, heavy moisture, erosion, extensive<br />

shock and vibration. Also, extensive EMI can prevent<br />

some of the equipment used in the ship, especially the<br />

compass and navigation systems, from operating<br />

improperly.<br />

Industrial Solutions<br />

DNV ( Det Norske Veritas)<br />

The DNV Organization<br />

originated in Norway. Initially,<br />

DNV was to provide<br />

consulting services for<br />

managing the risk and quality<br />

control systems onboard ships.<br />

Today, DNV Maritime is<br />

recognized by 80 national<br />

maritime authorities in<br />

managing their risk for the<br />

“Tough” maritime environmental<br />

conditions.<br />

Bypass hydraulic<br />

control system<br />

Normally, an offshore<br />

platform equips with one<br />

or several cranes to lift<br />

cargo around the<br />

platform and between<br />

boats. This control<br />

system helps adjust the<br />

cranes.<br />

Crane heave motion<br />

compensator<br />

Located near the bypass hydraulic<br />

control system, the compensator is<br />

for keeping the load at a fixed<br />

position relative to the seabed, and to<br />

avoid that the vessel motion is being<br />

transferred to the load. The AHC<br />

control is connected to a motion<br />

reference unit (MRU) that feeds the<br />

system with accurate real-time<br />

information of the crane tip motion.<br />

Helicopter landing pad<br />

Commonly abbreviated as helipad,<br />

which is the landing area for<br />

helicopters. For offshore platform,<br />

helipad also referred to as helideck.<br />

<strong>Product</strong> Selections<br />

IES-0204FT-DNV (P.23)<br />

IES-0008T-DNV (P.23)<br />

Problems caused by erosion, heavy moisture and extreme working temperatures are commonly<br />

seen on offshore platforms. <strong>Lantech</strong>’s DNV (Det Norske Veritas) type industrial switches are<br />

designed to cope with this kind of harsh environment. Given the diversity of locations that<br />

switches may be used, Industrial Switches are needed for the various types of approvals under<br />

DNV classification.<br />

DNV maritime certification specifics the test criteria for all equipment used for offshore<br />

platforms. Most of the <strong>Lantech</strong> DNV models are UL class I division II certified, which ensures the<br />

safety when installed at the flammable places.<br />

LES-2400-RPS-DNV (P.23)<br />

P9


Cruise Liner<br />

Challenges: Marine ships are confronted with several<br />

challenges for on-board equipment including vibration,<br />

high voltage, conducted radio frequency immunity and<br />

emission. For the adventure of on-board passengers,<br />

entertainment system is featured by cruise liners, so a<br />

reliable and high efficient Ethernet network is essential<br />

to handle all video, voice and data packets from<br />

everywhere in the ship.<br />

Sonar system<br />

The sonar system, which helps to locate<br />

the position, requires a high-speed<br />

network to connect devices in the hull<br />

unit room with other devices on the<br />

bridge.<br />

Entertainment system<br />

To offer best comfort and luxury joy for<br />

passengers on-board, cruise liner has<br />

amenity of room-entertainment systems<br />

where can choose movie, music or other<br />

entertainment programs they want at<br />

anytime.<br />

Control Room<br />

UTP<br />

Fiber<br />

DHCP<br />

Server<br />

DHCP<br />

Server<br />

LES-2400-RPS<br />

IEC-0101FT-DNV<br />

Pro-Ring<br />

Pro-Ring<br />

Pro-Ring<br />

IES-2208F-DNV<br />

Deck A<br />

IES-2216C-DNV<br />

Deck B<br />

Deck C<br />

Deck surveillance<br />

system<br />

Since the cruise liner<br />

carries a lot of<br />

passengers, it is<br />

important to monitor<br />

everyone’s safety. The<br />

surveillance system at<br />

each deck is connected to<br />

the central control room.<br />

Industrial Solutions<br />

For sonar system, the Ethernet network allows the transmission of signals<br />

from the sonar to the ship’s bridge in real time. <strong>Lantech</strong> provides a total<br />

solution, combining our industrial grade and business grade models to<br />

maximize the benefit. Both industrial grade and business grade models<br />

passed the extreme tests of DNV, providing the qualified protection for<br />

the cruise liner. For example, extensive EMI can prevent some of the<br />

equipment used in the ship, especially the compass and navigation<br />

systems, from operating improperly.<br />

IEC-0101FT-DNV (P.23)<br />

<strong>Product</strong> Selections<br />

LES-2400-RPS-DNV (P.23)<br />

Industrial switches can be used in the hull unit room to connect to<br />

different sonar devices, while the aggregated switches are installed in the<br />

bridge. Together, the switches create a redundant ring that connects the<br />

end devices to the control center. On the other hand, the fiber optical<br />

connection ensures the smooth and seamless video transmission for<br />

surveillance system at each deck with its huge bandwidth.<br />

IES-2208F-DNV (P.23)<br />

IES-2216C-DNV (P.23)<br />

P10


Water Treatment Plant<br />

Challenges: Water treatment process is essential for<br />

modern life to make water more acceptable and<br />

eliminating bad residues existing in many public<br />

sanitation systems then to return water back into<br />

natural environment without ecological impacts for the<br />

use of drinking water, industrial process, medical, hotel<br />

process and others.<br />

Industrial Solutions<br />

Upper Layer Switch<br />

Sedimentation tank<br />

It is the final step in the secondary treatment stage, which is the most<br />

representational structure of a water treatment plant. Through a<br />

RTU<br />

RTU<br />

secondary clarifier, the biological floc or filter material is settled out. After<br />

this step, sewage water containing low levels of organic material and<br />

Ragular Ethernet Path<br />

suspended matter is produced.<br />

X-Ring Backup Path<br />

Dual Homing Backup Path<br />

RTU<br />

IP Camera<br />

RTU<br />

IP Phone<br />

<strong>Product</strong> Selections<br />

Using the industrial Ethernet network is the most convenient and reliable solution for water<br />

treatment system to connect with SCADA, PLC, water sensors, water bumps etc. Since the<br />

water treatment plant might cover huge floor space, the long transmission distance becomes<br />

one of the major considerations.<br />

IES-1005T (P.29)<br />

By utilizing <strong>Lantech</strong>’s Pro-Ring system, the connection quality is protected under this fast<br />

redundant ring protocol, which is less than 10ms. Subject to different areas connection such as<br />

drainage well and leveraged wells, the switches could connect with aerator RTU, sludge removal<br />

RTU, or primary clarifier RTU, etc and protect all by Pro-Ring scheme. Via <strong>Lantech</strong> products, the<br />

whole network system is able to be monitored from control room remotely.<br />

IES-1204FT (P.29)<br />

P11


Challenges: Due to extremely connection demand, the<br />

ISP infrastructure requires absolutely high density<br />

network capacity. To transmit data efficiently, there<br />

should be a useful and universal network protocol. To<br />

manage the large amount of users is another issue,<br />

which is very important for customer satisfaction.<br />

ISP Infrastructure<br />

ISP<br />

Pro Ring < 10ms<br />

End Users<br />

Triple Play<br />

It is a marketing term for the<br />

provisioning of two<br />

bandwidth-intensive services,<br />

high-speed Internet access<br />

and television, and a less<br />

bandwidth-demanding<br />

service, telephone, over a<br />

single broadband connection.<br />

Although voice service<br />

requires less bandwidth, it is<br />

more latency-sensitive due to<br />

real time communications.<br />

Industrial Solutions<br />

Fiber<br />

RJ45<br />

Fiber<br />

Node<br />

<strong>Product</strong> Selections<br />

With <strong>Lantech</strong>’s high density fiber gigabit or 100M aggregation switches, it is easy to build up a<br />

backbone network for ISP demand. The bandwidth-intensive services such as internet access<br />

and video can be transmitted fluently. Fiber connection allows long distance data transmission<br />

up to 120km, making remote management more easily.<br />

IGS-2404 (P.25)<br />

IGMP, which is a universal network protocol, helps to reduce network traffic and provides good<br />

network quality for triple play usage. The power input range is another issue when installing ISP<br />

infrastructure since most of the power supply is restricted to 48VDC in ISP infrastructure<br />

environment. To solve the problem, <strong>Lantech</strong> industrial switches provide wide range redundant<br />

power inputs, which make <strong>Lantech</strong> products the best choice for ISP applications.<br />

IGS-2206C (P.25)<br />

P12


<strong>Lantech</strong>-View Lite<br />

<strong>Lantech</strong>-View Lite and Pro are powerful and easy-to-use network management softwares that allow the<br />

topology of entire networks to be viewed as simple and straightforward topology maps. Having a readily<br />

available visual representation of your network allows streamlined network monitoring, event handling, and<br />

troubleshooting.<br />

<strong>Lantech</strong>-View Lite and Pro are highly compatible and can automatically discover SNMP switches for network<br />

topology visualization. <strong>Lantech</strong>-View Lite and Pro provide a powerful management platform for <strong>Lantech</strong><br />

network devices by offering innovative live-view topology maps for real-time network management.<br />

<strong>Lantech</strong>-View Lite<br />

• Network topology view<br />

• Device discovery<br />

• Network statistic<br />

• Device fault alarm<br />

• Device web interface<br />

• Batch firmware upgrade<br />

• Batch IP assignment<br />

P13


<strong>Lantech</strong>-View Pro<br />

• Network topology view • Device discovery • Network statistic<br />

• Device Fault alarm • Device Web Interface • Batch firmware upgrade<br />

• Batch IP assignment • Device management • Telnet via NMS<br />

• MIB browser • MIB Complier • Polling Node<br />

• Event Count • Editable tool bar • Threshold Event Monitor<br />

• Throughput Monitor • Trap View Monitor<br />

<strong>Lantech</strong>-View Pro<br />

P14


Pro-Ring System<br />

For Ethernet, network redundancy means a network hardware link down or disconnection cable will not<br />

interrupt communications. Also, to achieve network redundancy, one must use a managed switch, since<br />

advanced traffic management is required to prevent "looping" of data packets.<br />

Where an interruption of a few seconds is acceptable in the office, it’s an eternity for most manufacturing<br />

environments or other mission-critical networks. A communication gap of a few seconds or more could<br />

cause loss of critical data or worse yet -- system shutdown.<br />

Common enterprise technologies like Rapid Spanning Tree Protocol (RSTP) generally take between 2 to 10<br />

seconds to recover after a fault, and older technologies like Spanning Tree Protocol (STP) could take even<br />

longer -- 30 to 60 seconds.<br />

Pro-Ring System<br />

Pro-Ring system is a proprietary protocol, for applications where a ring architecture is desired (most<br />

manufacturing or other mission-critical projects) that uses a pulling scheme to detect whenever a cable<br />

break or link fault occurs, it will automatically find a backup path in under 10 milliseconds for networks of up<br />

to 250 <strong>Lantech</strong> switches.<br />

As a result, Pro-Ring system is very important in applications where downtime is expensive.<br />

<strong>Lantech</strong> new Pro-Ring II system eliminates the need to manually set ring master and evolves comprehensive<br />

redundant ring architectures.<br />

X-Ring Application<br />

Basic Pro-Ring system is X-Ring.<br />

Data collect server<br />

Enterprise Switch<br />

Human Management Interface<br />

Pro-Ring<br />

Backup path<br />

Pro-Ring<br />

R.T. < 10ms<br />

Field Management<br />

Industrial Switch<br />

Industrial Switch<br />

Distribute I/O control system<br />

Programmable logic controller<br />

Field Automatic device<br />

Serial Device Server<br />

Field Automatic device<br />

P15


Coupling Ring Application<br />

Couple Ring is designed for the Network redundancy between two Rings.<br />

Coupling Port<br />

Coupling Ring<br />

Backup Path<br />

Coupling Port<br />

Backup path<br />

Switch 1<br />

Control Port<br />

Coupling Ring<br />

Group<br />

Control Port<br />

Switch 3<br />

Pro-Ring Group A<br />

R.T. < 10ms<br />

Switch 2<br />

Coupling Port<br />

Switch 4<br />

Pro-Ring Group B<br />

R.T. < 10ms<br />

Backup Path<br />

Blocking<br />

Port<br />

Dual Ring<br />

Backup path<br />

Central / Dual Ring Application<br />

Central Ring can ring together 4 ring in which one managed switch could be the ring master, while Dual Ring is<br />

structed within two rings by one ring master.<br />

Pro-Ring System<br />

Ring 3<br />

R.T. < 10ms<br />

Ring 1<br />

R.T. < 10ms<br />

Ring 2<br />

R.T. < 10ms<br />

Ring<br />

Master<br />

Ring 4<br />

R.T. < 10ms<br />

Forwarding<br />

Port<br />

Dual Homing Application<br />

Dual Homing is to have back up path when the ring is connected to upper switch that is from third-party by RSTP<br />

algorithem to be recoverd in 5 seconds.<br />

Enterprise Switch<br />

Rapid Spanning Tree Protocol<br />

Enterprise Switch<br />

Hot Standby Link<br />

Pro-Ring<br />

Backup path<br />

Industrail<br />

Switch<br />

Primary Dual-Homming<br />

Pro-Ring Group A<br />

R.T. < 10ms<br />

Dual Homming<br />

Backup port<br />

Primary Dual-Homming<br />

Pro-Ring Group B<br />

R.T. < 10ms<br />

Industrail<br />

Switch<br />

Secondary Dual-Homming<br />

Pro-Ring<br />

Backup path<br />

Ring Masters<br />

Ring Masters<br />

P16


Pro-Ring II System<br />

Pro-Ring II is a new Ring mechanism for <strong>Lantech</strong> Industrial Switches in which it eliminates the need to pre-set<br />

the Master switch in old Pro-Ring and yet to protect the network by much secure topologies than ever.<br />

Pro-Ring II works as a Ring Chain to reduce the risk of master switch linking down whereas the setup<br />

becomes much easier. Pro-Ring II can be backward compatible with old Pro-Ring by down-grading the Ring<br />

scheme to old one.<br />

Daisy-Couple Ring<br />

For larger and single LAN group, Daisy-Couple Ring could achieve self-recovery time in less than 10ms in<br />

which the ring group will choose automatically for Master switch, detect loop and form path recovery<br />

architecture.<br />

Pro-Ring II System<br />

Backup Path Backup Path Backup Path Backup Path<br />

Pro-Ring II Pro-Ring II Pro-Ring II Pro-Ring II<br />

Backup Path Backup Path Backup Path<br />

Multi-Couple Ring<br />

For multiple ring groups, it helps to structure ring activities among different LANs. Each ring group has more<br />

than 3 redundant paths for backup.<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Backup Path<br />

Backup Path<br />

Backup Path<br />

Backup Path Backup Path Backup Path Backup Path<br />

Pro-Ring II Pro-Ring II Pro-Ring II Pro-Ring II<br />

Backup Path Backup Path Backup Path<br />

Advanced Dual Homing<br />

When the ring group is connected to upper switch by RSTP algorithm, it strengths the uplink connection<br />

with its own redundant path which double secures the link than of traditional Dual Homing.<br />

RSTP<br />

Backup Path<br />

Backup Path<br />

Backup Path<br />

Pro-Ring II<br />

Pro-Ring II<br />

Backup Path<br />

P17


Key Ring<br />

When the middle or aggregation points are critical, Key Ring can protect the middle connection<br />

to the core or upper switch by separating different layers of links or ring groups.<br />

Backup Path<br />

Pro-Ring II<br />

Key-Ring<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Pro-Ring II<br />

Multi-Key Ring<br />

Multi-Key Ring forms triangle connection among different ring groups to create the de-militarized<br />

zone in the network topology and maintain the redundancy.<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Pro-Ring II System<br />

Backup Path<br />

Backup Path<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Backup Path<br />

Backup Path<br />

Pro-Ring II<br />

Backup Path<br />

Backup Path<br />

Features Pro-Ring II Pro-Ring<br />

Redundancy Solution ★15 3<br />

Auto Master Selection ★Yes No<br />

Max. unit 250 250<br />

Single algorithm ★Yes No<br />

Recovery time for Dual-Homing ★


Industrial EN50155 Switches<br />

Designed for railway and other rugged applications,<br />

<strong>Lantech</strong> EN50155 compliant series provides IP67/IP41<br />

protection to against dust and water jet or immersion.<br />

The M12 connectors ensure reliable operation with<br />

on-board devices. The series also supports fully<br />

managed functions with high level security and <strong>Lantech</strong><br />

Pro-Ring redundant system.<br />

Industrial Ethernet Switches<br />

IES-0005-M12<br />

5 10/100TX M12 /<br />

IP41 Industrial Switch<br />

IES-2008-67<br />

8 10/100TX M12 /<br />

IP67 Managed Industrial Switch<br />

-UL508<br />

IES-0008-M12<br />

8 10/100TX M12 /<br />

IP41 Industrial Switch<br />

IES-2208F-67<br />

8 10/100TX + 2 100FX M12 /<br />

IP67 Managed Industrial Switch<br />

IPES-0008-4-M12<br />

8 10/100TX M12 /<br />

IP41 Industrial Switch<br />

w/4 PoE Injectors<br />

-24~48VDC Power Input<br />

IPES-2208GF-67<br />

8 10/100TX + 2 1000FX M12 /<br />

IP67 Managed Industrial Switch<br />

w/8 PoE Injectors<br />

-UL508 / UL C1D2<br />

128-bit<br />

Encryption<br />

Pro-Ring<br />

50 mm 1 Dripping water<br />

2 > 12.5 mm 2 Dripping water when tilted up to 15°<br />

3 > 2.5 mm 3 Spraying water<br />

4 > 1 mm 4 Splashing water<br />

5 Dust protected 5 Water jets<br />

6 Dust tight 6 Powerful water jets<br />

7 Immersion up to 1m<br />

8 Immersion beyond 1m<br />

P19


HARDWARE FEATURES<br />

Port<br />

IES-0005-M12 IES-0008-M12 IPES-0008-4-M12 IES-2008-67 IES-2208F-67 IPES-2208GF-67<br />

10/100TX 5 (M12) 8 (M12) 8 (M12) 8 (M12) 8 (M12) 8 (M12)<br />

100FX - - - - 2 (LC) -<br />

1000FX - - - - - 2 (LC)<br />

1000M SFP - - - - - -<br />

10/100/1000T/Dual Speed SFP Combo - - - - - -<br />

RS232 connector M12 M12 M12 M12 M12 M12<br />

PoE Injector - - 4 - - 8<br />

Switching Fabric 1.0Gbps 1.6Gbps 1.6Gbps 5.6Gbps 5.6Gbps 5.6Gbps<br />

Packet Buffer 448Kbits 448Kbits 448Kbits 1Mbits 1Mbits 1Mbits<br />

Mac Address 2K 2K 2K 8K 8K 8K<br />

Flash ROM - - - 4Mbytes 4Mbytes 4Mbytes<br />

DRAM - - - 32Mbytes 32Mbytes 32Mbytes<br />

Power Supply<br />

*Optional<br />

9~56VDC<br />

(M12 connector)<br />

9~56VDC<br />

(M12 connector)<br />

24~48VDC<br />

(M12 connector)<br />

9~56VDC<br />

(M12 connector)<br />

9~56VDC<br />

(M12 connector)<br />

48VDC (45~56VDC)<br />

(M12 connector)<br />

Redundant Power ● ● ● ● ● ●<br />

Power Consumption 10.7 Watts 10.7 Watts 72 Watts@24VDC 14 Watts 14 Watts 14 Watts<br />

Overload Current Protection ● ● ● ● ● ●<br />

Polarity Reverse Protection ● ● ● ● ● Polarity Protection<br />

Relay Contact with Alarm System ● ● ● ● ● ●<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

● ● ● ● ● ●<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

● ● ● ● ● ●<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

● ● ● ● ● ●<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

92 x 180 x 42 92 x 180 x 42 92 x 180 x 42 193 x 62.5 x 176 193 x 62.5 x 176 193 x 62.5 x 176<br />

Case Protection IP41 IP41 IP41 IP67 IP67 IP67<br />

Weight 750g 800g 900g 1630g 1630g 1730g<br />

DIN Rail Installation ● ● ● - - -<br />

Wall Mount Installation ● ● ● ● ● ●<br />

CE/ FCC/ UL ● ● ● CE/ FCC/ UL508 ● CE/ FCC/ UL508<br />

RoHS/ WEEE ● ● ● ● ● ●<br />

EN50155/ e-Mark Pending Pending Pending Pending Pending Pending<br />

Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ●<br />

MTBF 391,306 hours 391,306 hours 348,384 hours 388,201 hours 320,420 hours 320,420 hours<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 - - - ● ● ●<br />

Web Browser - - - ● ● ●<br />

Telnet - - - ● ● ●<br />

CLI - - - ● ● ●<br />

<strong>Lantech</strong>-View - - - ● ● ●<br />

IGMP snooping v1 v2/ IGMP query - - - ● ● ●<br />

VLAN - - - ● ● ●<br />

Port Trunk with LACP - - - ● ● ●<br />

LLDP - - - ● ● ●<br />

SSL/ SSH - - - ● ● ●<br />

Port Security - - - ● ● ●<br />

IP Security - - - ● ● ●<br />

Login Security (RADIUS) - - - ● ● ●<br />

SNTP - - - ● ● ●<br />

SMTP - - - 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts<br />

Bandwidth Control - - - ● ● ●<br />

Flow Control - - - ● ● ●<br />

Pro-Ring System<br />

X-Ring - - - ● ● ●<br />

Dual Homing - - - ● ● ●<br />

Couple Ring - - - ● ● ●<br />

Central Ring - - - - - -<br />

Dual Ring - - - - - -<br />

Spanning Tree/ RSTP - - - ● ● ●<br />

Port Mirror - - - ● ● ●<br />

Quality of Service - - - ● ● ●<br />

Class of Service - - - ● ● ●<br />

System Log - - - ● ● ●<br />

Relay Alarm - - - ● ● ●<br />

SNMP Trap - - - ● ● ●<br />

DHCP - - - Client/ Server Client/ Server Client/ Server<br />

DNS Client/ Server - - - ● ● ●<br />

TFTP Firmware Update/ Backup /Resotre - - - ● ● ●<br />

Configuration upload and download - - - ● ● ●<br />

ORDERING INFORMATION (part number)<br />

Wide Operating Temp. (-40°C~75°C)<br />

IES-0005-M12 IES-0008-M12 IPES-0008-4-M12 IES-2008-67 IES-2208F-67 IPES-2208GF-67<br />

8360-480 (MM, 2KM) 8350-950 (MM, 2KM)<br />

8360-556 8360-550<br />

8360-540<br />

8360-490<br />

8360-481 (SM, 30KM) 8350-951 (SM, 30KM)<br />

P20


Industrial IEC 61850-3 Switches<br />

<strong>Lantech</strong> IEC 61850-3 series features high reliability and<br />

robustness. Each model is compliant with IEC 61850-3<br />

& IEEE 1613 standards sustaining the high interference<br />

EMI / RFI environment in substations. Widely<br />

operational temperature capacity and GOOSE<br />

compliance ensure the switch runtime among the<br />

harsh environment of power utilities. They are also<br />

good at rail train on-board network where the power<br />

input is 100VDC.<br />

Industrial Ethernet Switches<br />

IES-2224-2P<br />

24 10/100TX + 2 1000 SFP<br />

Industrial L2 Plus Managed Switch<br />

IEC 61850 features include:<br />

IES-22812F-2P<br />

12 100FX + 8 10/100TX + 2 1000 SFP<br />

Industrial L2 Plus Managed Switch<br />

Data Modeling -- Primary process objects as well as protection and control functionality in the substation is modeled into different standard<br />

logical nodes which can be grouped under different logical devices. There are logical nodes for data/functions related to the logical device<br />

(LLN0) and physical device (LPHD).<br />

Reporting Schemes -- There are various reporting schemes (BRCB & URCB) for reporting data from server through a server-client relationship<br />

which can be triggered based on pre-defined trigger conditions.<br />

Fast Transfer of events -- Generic Substation Event (GSE) are defined for fast transfer of event data for a peer-to-peer communication mode.<br />

This is again subdivided into GOOSE & GSSE.<br />

Setting Groups -- The setting group control Blocks (SGCB) are defined to handle the setting groups so that user can switch to any active group<br />

according to the requirement.<br />

Sampled Data Transfer -- Schemes are also defined to handle transfer of sampled values using Sampled Value Control blocks (SVCB)<br />

Commands -- Various command types are also supported by IEC 61850 which include direct & select before operate (SBO) commands with<br />

normal and enhanced securities.<br />

Data Storage-- SCL(Substation Configuration Language) is defined for complete storage of configured data of the substation in a specific<br />

format.<br />

Pro-Ring<br />


IES-2224-2P<br />

IES-22812F-2P<br />

HARDWARE FEATURES<br />

Port<br />

10/100TX 24 8<br />

100FX - 12 (SC)<br />

1000M SFP 2 2<br />

RS232 connector RJ-45 RJ-45<br />

Switching Fabric 8.8Gbps 8.0Gbps<br />

Packet Buffer 4Mbits 4Mbits<br />

Jumbo Frame 9K (for Gigabit Ports) 9K (for Gigabit Ports)<br />

Mac Address 8K 1K<br />

Flash ROM 4Mbytes 4Mbytes<br />

DRAM 32Mbytes 32Mbytes<br />

Power Supply<br />

*Optional<br />

2 X VAC/VDC 100V~240V 2 X VAC/VDC 100V~240V<br />

Redundant Power ● ●<br />

17.5 Watts@VDC<br />

23 Watts@VDC<br />

Power Consumption<br />

21.5 Watts@VAC<br />

27 Watts@VAC<br />

Overload Current Protection ● ●<br />

Polarity Reverse Protection ● ●<br />

Relay Contact with Alarm System ● ●<br />

Operating Temperature<br />

-40°C ~85°C<br />

-40°F ~185°F<br />

-40°C ~85°C<br />

-40°F ~185°F<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

●<br />

●<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

●<br />

●<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

440 x 280 x 44 440 x 280 x 44<br />

Case Protection IP30 IP30<br />

Weight 3000g 4900g<br />

19-inch Rack Mount ● ●<br />

CE/ FCC/ UL ● ●<br />

RoHS/ WEEE ● ●<br />

IEC 61850-3 / IEEE1613 Pending Pending<br />

Stability Testing (Free fall/ Shock/ Vibration) ● ●<br />

MTBF 109,064 hours 89,370 hrs<br />

Warranty 5 years 5 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ●<br />

Web Browser ● ●<br />

Telnet ● ●<br />

CLI ● ●<br />

<strong>Lantech</strong>-View ● ●<br />

IGMP snooping v1 v2/ IGMP query ● ●<br />

VLAN ● ●<br />

Port Trunk with LACP ● ●<br />

LLDP ● ●<br />

Port Security ● ●<br />

IP Security ● ●<br />

Login Security (RADIUS) ● ●<br />

SNTP ● ●<br />

SMTP 6 e-mail accounts 6 e-mail accounts<br />

Bandwidth Control ● ●<br />

Flow Control ● ●<br />

Pro-Ring System<br />

X-Ring ● ●<br />

Dual Homing ● ●<br />

Couple Ring ● ●<br />

Central Ring - -<br />

Dual Ring - -<br />

Spanning Tree/ RSTP ● ●<br />

Port Mirror ● ●<br />

Quality of Service ● ●<br />

Class of Service ● ●<br />

System Log ● ●<br />

Relay Alarm ● ●<br />

SNMP Trap ● ●<br />

DHCP ● ●<br />

DNS Client/ Server Client/ Server Client/ Server<br />

TFTP Firmware Update/ Backup /Resotre ● ●<br />

Configuration upload and download ● ●<br />

ifAlias - -<br />

ORDERING INFORMATION (part number)<br />

Wide Operating Temp. (-40°C~85°C)<br />

IES-2224-2P<br />

8350-715<br />

IES-22812F-2P<br />

8360-320 (MM, 2KM)<br />

8360-321 (SM, 30KM)<br />

P22


Industrial DNV Type Switches<br />

Meet with the most critical test criteria in DNV Type<br />

test, <strong>Lantech</strong> DNV type approval switches ensure the<br />

switches sustaining the harsh on-board environments<br />

often founded in Ships, Crafts and Offshore platforms.<br />

The wide product line provides the most flexibility for<br />

maritime applications.<br />

Industrial Ethernet Switches<br />

IES-0005T-DNV<br />

5 10/100TX Slim Type<br />

Industrial Switch<br />

IEC-0101FT-DNV<br />

1 10/100TX to 100M-FX<br />

Slim Type Converter<br />

IES-0008T-DNV<br />

8 10/100TX Slim Type<br />

Industrial Switch<br />

IES-2216C-DNV<br />

16 10/100TX + 2 10/100/1000T/Dual<br />

Speed SFP Combo w/Pro-Ring<br />

Managed Industrial Switch<br />

IES-0104FT-DNV*<br />

4 10/100TX + 1 100FX<br />

Industrial Switch<br />

LES-2400-RPS-DNV*<br />

3 slots 10/100M Modularized + 2 x<br />

Gigabit Combo L2 Plus Managed<br />

Switch w/Redundant Power Supply<br />

Type Industrial Switch<br />

IES-0204FT-DNV*<br />

4 10/100TX + 2 100FX<br />

Industrial Switch<br />

IES-2208F-DNV*<br />

8 10/100TX + 2 100FX<br />

Managed Industrial Switch<br />

w/Pro-Ring<br />

Pro-Ring<br />


IES-0005T-DNV IES-0008T-DNV IES-0104FT-DNV IES-0204FT-DNV IEC-0101FT-DNV IES-2208F-DNV IES-2216C-DNV LES-2400-RPS-DNV<br />

HARDWARE FEATURES<br />

Port<br />

10/100TX 5 8 4 4 1 8 16 Max 24<br />

100FX - - 1 (SC) 2 (SC) 1 (SC or ST) 2 (SC) - Max 24<br />

100M SFP - - - - - - - Max 24<br />

10/100/1000T/Dual Speed SFP Combo - - - - - - 2 2<br />

RS232 connector - - - - - RJ-45 RJ-45 DB-9 Female<br />

Switching Fabric 1.0Gbps 1.6Gbps 1.0Gbps 1.2Gbps - 1.6Gbps 7.2Gbps 8.8Gbps<br />

Packet Buffer 448Kbits 448Kbits 448Kbits 448Kbits - 1Mbits 1Mbits 4Mbits<br />

Jumbo Frame - - - - - - - 9K (for Gigabit Ports)<br />

Mac Address 2K 2K 2K 2K 2K 8K 8K 8K<br />

Flash ROM - - - - - 4Mbytes 4Mbytes -<br />

DRAM - - - - - 32Mbytes 32Mbytes -<br />

Power Supply<br />

*Optional<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

Redundant Power ● ● ● ● ● ● ● 12~48VDC<br />

Power Consumption 2.93 Watts 4.71 Watts 4.44 Watts 6.41 Watts 2.74 Watts 11.28 Watts 10 Watts 18 Watts<br />

Overload Current Protection ● ● ● ● ● ● ● -<br />

Polarity Reverse Protection ● ● ● ● ● ● ● -<br />

Relay Contact with Alarm System ● ● ● ● ● ● ● -<br />

100~240VAC,<br />

50/60Hz<br />

Standard Operating Temperature<br />

● ● ● ● ● ● ●<br />

-20°C~60°C / -4°F~140°F<br />

-20°C~60°C<br />

Wide Operating Temperature<br />

-4°F~140°F<br />

● ● ● ● ● ● ●<br />

-40°C~75°C / -40°F~167°F<br />

Storage Temperature<br />

-40°C~70°C<br />

● ● ● ● ● ● ●<br />

-40°C~85°C / -40°F~185°F<br />

-40°F~158°F<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

● ● ● ● ● ● ● 5%~95%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 72 x 105 x 152 72 x 105 x 152 440 x 200 x 44<br />

Case Protection IP30 IP30 IP30 IP30 IP30 IP30 IP30 -<br />

Weight 430g 480g 800g 810g 600g 1000g 1049g 5000g<br />

DIN Rail Installation ● ● ● ● ● ● ● -<br />

Wall Mount Installation ● ● ● ● ● ● ● -<br />

19-inch Rack Mount - - - - - - - ●<br />

CE/ FCC/ UL ● ● CE/ FCC CE/ FCC ● ● ● ●<br />

RoHS/ WEEE ● ● ● ● ● ● ● ●<br />

UL Class I Division II Certification ● ● - - ● ● ● -<br />

DNV Type Approved ● ● Pending Pending ● Pending ● Pending<br />

Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ● ● -<br />

MTBF 412,590 hours 388,566 hours 380,717 hours 347,014 hours 405,486 hours 232,194 hours 220,111 hours 75,900 hours<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years 5 years 2 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ● ●<br />

Web Browser ● ● ●<br />

Telnet ● ● ●<br />

CLI ● ● ●<br />

<strong>Lantech</strong>-View ● ● -<br />

IGMP snooping v1 v2/ IGMP query ● v1 v2 v3 ●<br />

VLAN ● ● ●<br />

Port Trunk with LACP ● ● ●<br />

LLDP ● ● ●<br />

Port Security ● ● ●<br />

IP Security ● ● ●<br />

Login Security (RADIUS) ● ● ●<br />

SNTP ● ● ●<br />

SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts<br />

Bandwidth Control ● ● ●<br />

Flow Control ● ● ●<br />

Pro-Ring System<br />

X-Ring ● ● ●<br />

Dual Homing ● ● ●<br />

Couple Ring ● ● ●<br />

Spanning Tree/ RSTP ● ●<br />

STP/ RSTP/<br />

MSTP (Optional)<br />

Port Mirror ● ● ●<br />

Quality of Service ● ● ●<br />

Class of Service ● ● ●<br />

System Log ● ● ●<br />

Relay Alarm ● ● -<br />

SNMP Trap ● ● ●<br />

DHCP Client/ Server Client/ Server Client/ Server<br />

DNS Client/ Server ● ● ●<br />

TFTP Firmware Update/ Backup /Resotre ● ● ●<br />

Configuration upload and download ● ● ●<br />

ifAlias ● ● -<br />

ORDERING INFORMATION (part number)<br />

IES-0005T-DNV IES-0008T-DNV IES-0104FT-DNV IES-0204FT-DNV IEC-0101FT-DNV IES-2208F-DNV IES-2216C-DNV LES-2400-RPS-DNV<br />

-40°C~75°C, DNV type<br />

-40°C~75°C, AC input, DNV type<br />

8350-632DNV<br />

8350-632DNV-AC<br />

8350-621DNV<br />

8350-621DNV-AC<br />

8350-335DNV<br />

(MM, 2KM)<br />

8350-336DNV<br />

(SM, 30KM)<br />

8350-335DNV-AC<br />

(MM, 2KM)<br />

8350-336DNA-AC<br />

(SM, 30KM)<br />

8350-345DNV<br />

(MM, 2KM)<br />

8350-346DNV<br />

(SM, 30KM)<br />

- -<br />

- -<br />

- -<br />

8350-345DNV-AC<br />

(MM, 2KM)<br />

8350-346DNV-AC<br />

(SM, 30KM)<br />

- -<br />

- -<br />

- -<br />

8350-025DNV<br />

(SC, MM, 2KM)<br />

8350-023DNV<br />

(ST, MM, 2KM)<br />

8350-004DNV<br />

(SC, MM, 5KM)<br />

8350-005DNV<br />

(ST, MM, 5KM)<br />

8350-026DNV<br />

(SC, SM, 30KM)<br />

8350-025DNV-AC<br />

(SC, MM, 2KM)<br />

8350-023DNV-AC<br />

(ST, MM, 2KM)<br />

8350-004DNV-AC<br />

(SC, MM, 5KM)<br />

8350-005DNV-AC<br />

(ST, MM, 5KM)<br />

8350-026DNV-AC<br />

(SC, SM, 30KM)<br />

8350-419DNV<br />

(SC, MM, 2KM)<br />

8350-418DNV<br />

(SC, SM, 30KM)<br />

8350-419DNV-AC<br />

(SC, MM, 2KM)<br />

8350-418DNV-AC<br />

(SC, SM, 30KM)<br />

8350-655DNV<br />

8350-655DNV-AC<br />

8220-600DNV<br />

(-20°C~60°C)<br />

P24


Industrial Managed Switches<br />

<strong>Lantech</strong> SNMP managed switches offer advanced<br />

functions to cover most of the network requirements.<br />

Each model also supports Pro-Ring system for less than<br />

10ms auto-recovery network protection.<br />

Industrial Ethernet Switches<br />

IES-2008A<br />

8 10/100TX Managed<br />

Industrial Switch<br />

IES-2216C<br />

16 10/100TX + 2 10/100/1000T/Dual<br />

Speed SFP Combo Industrial Switch<br />

- UL C1D2<br />

IES-2206F-II<br />

6 10/100TX + 2 100FX Industrial<br />

Managed Switch<br />

IES-2307C<br />

7 10/100TX + 3 10/100/1000T with<br />

100/1000M SFP Combo Industrial<br />

Managed Switch<br />

- with DIDO<br />

- UL C1D2<br />

IES-2208C<br />

8 10/100TX + 2 10/100/1000T/<br />

Dual Speed SFP Combo Industrial<br />

Switch<br />

IGS-2206C<br />

6 10/100/1000T + 2<br />

10/100/1000T/Dual Speed<br />

SFP Combo Industrial Switch<br />

- UL C1D2<br />

IES-2208F<br />

8 10/100TX +2 100FX Managed<br />

Industrial Switch<br />

IGS-2404<br />

4 10/100/1000T + 4<br />

10/100/1000T/SFP<br />

Industrial Switch<br />

- UL C1D2 (Standard Model)<br />

- UL508 (-E Model)<br />

LES-2400-RPS<br />

3 slots 10/100M Modularized + 2 x<br />

Gigabit Combo L2 Plus Managed<br />

Switch w/Redundant Power Supply<br />

Type Industrial Switch<br />

- 2 Years Warranty<br />

Pro-Ring<br />


HARDWARE FEATURES<br />

Port<br />

IES-2008A IES-2206F-II IES-2208C IES-2208F IES-2216C IES-2307C IGS-2206C IGS-2404 LES-2400-RPS<br />

10/100TX 8 6 8 8 16 7 - - Max 24<br />

100FX - 2 (SC) - 2 (SC) - - - - Max 24<br />

1000FX - - - - - - - - -<br />

10/100/1000T - - - - - - 6 4 -<br />

100M SFP - - - - - - - Max 24<br />

4 (Dual Speed)<br />

1000M SFP - - - - - - - -<br />

10/100/1000T/Dual Speed SFP Combo - - 2 - 2 3 2 - 2<br />

RS232 connector RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 DB-9 Female<br />

PoE Injector - - - - - - - - -<br />

Switching Fabric 5.6Gbps 1.6Gbps 5.6Gbps 1.6Gbps 7.2Gbps 7.4Gbps 16Gbps 16Gbps 8.8Gbps<br />

Packet Buffer 1Mbits 1Mbits 1Mbits 1Mbits 1Mbits 1Mbits 1Mbits 1Mbits 4Mbits<br />

Jumbo Frame - - - - - - - 9K (for Gigabit Ports) 9K (for Gigabit Ports)<br />

Mac Address 8K 8K 8K 8K 8K 8K 8K 8K 8K<br />

Flash ROM 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4Mbytes 4Mbytes -<br />

DRAM 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32Mbytes 32Mbytes -<br />

Power Supply<br />

*Optional<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

Redundant Power ● ● ● ● ● ● ● ● 12~48VDC<br />

Power Consumption 8.8 Watts 9 Watts 9.5 Watts 11.28 Watts 10 Watts 10.2 Watts 18 Watts 17 Watts 18 Watts<br />

Overload Current Protection - ● ● ● ● ● - - -<br />

Polarity Reverse Protection ● ● ● ● ● ● ● ● -<br />

Relay Contact with Alarm System ● ● ● ● ● ● ● ● -<br />

DIDO (Digital Input/ Digital Output) - - - - - 2/2 - - -<br />

100~240VAC,<br />

50/60Hz<br />

Standard Operating Temperature<br />

-20°C~60°C / -4°F~140°F<br />

● ● ● ● ● ● ● ● ●<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

● ● ● ● ● ● ● - -<br />

Storage Temperature<br />

-40°C~70°C<br />

● ● ● ● ● ● ● ●<br />

-40°C~85°C / -40°F~185°F<br />

-40°F~158°F<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

● ● ● ● ● ● ● ● ●<br />

Case Dimension<br />

72 x 105 x 152<br />

72 x 105 x 152 52 x 106 x 144 72 x 105 x 152 72 x 105 x 152 72 x 105 x 152 72 x 105 x 152 72 x 105 x 152<br />

W x D x H (unit=mm)<br />

59.6 x 105 x 152 (-E)<br />

440 x 200 x 44<br />

Case Protection IP30 IP30 IP30 IP30 IP30 IP30 IP30 IP30 -<br />

Weight 1302g 735g 1302g 1000g 1049g 1300g 1418g 1250g 5000g<br />

DIN Rail Installation ● ● ● ● ● ● ● ● -<br />

Wall Mount Installation ● ● ● ● ● ● ● ● -<br />

19-inch Rack Mount - - - - - - - - ●<br />

CE/ FCC/ UL CE/ FCC CE/ FCC ● ● ● ● ● ● ●<br />

RoHS/ WEEE ● ● ● ● ● ● ● ● ●<br />

UL Class I Division II Certification - - - ● ● ● ● ● -<br />

DNV Type Approved - - - Pending ● - - - Pending<br />

EN50155 - - - - - - - - -<br />

IEC 61850 - - - - - - - - -<br />

Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ● ● ● ● -<br />

MTBF 272,761 hours 232,194 hours 272,761 hours 232,194 hours 220,111 hours 260,818 hours 248,507 hours 286,945 hours 75,900 hours<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years 5 years 5 years 2 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ● ● ● ● ● ● ● ●<br />

Web Browser ● ● ● ● ● ● ● ● ●<br />

Telnet ● ● ● ● ● ● ● ● ●<br />

CLI ● ● ● ● ● ● ● ● ●<br />

<strong>Lantech</strong>-View ● ● ● ● ● ● ● ● -<br />

Menu Driven - - - - - - Optional - -<br />

IGMP snooping v1 v2/ IGMP query ● ● ● ● ● ● ● ● ●<br />

VLAN ● ● ● ● ● ● ● ● ●<br />

Port Trunk with LACP ● ● ● ● ● ● ● ● ●<br />

LLDP ● ● ● ● ● ● ● ● ●<br />

Port Security ● ● ● ● ● ● ● ● ●<br />

IP Security ● ● ● ● ● ● ● ● ●<br />

Login Security (RADIUS) ● ● ● ● ● ● ● ● ●<br />

SNTP ● ● ● ● ● ● ● ● ●<br />

SMTP 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts 6 e-mail accounts<br />

Bandwidth Control ● ● ● ● ● ● ● ● ●<br />

Flow Control ● ● ● ● ● ● ● ● ●<br />

Pro-Ring System<br />

X-Ring ● ● ● ● ● ● ● ● ●<br />

Dual Homing ● ● ● ● ● ● ● ● ●<br />

Couple Ring ● ● ● ● ● ● ● ● ●<br />

Central Ring - - - - - - - - -<br />

Dual Ring ● - ● - - ● - - -<br />

Spanning Tree/ RSTP ● STP/ RSTP/ MSTP ● ● ● ● ● ●<br />

STP/ RSTP/ MSTP<br />

(Optional)<br />

Port Mirror ● ● ● ● ● ● ● ● ●<br />

Quality of Service ● ● ● ● ● ● ● ● ●<br />

Class of Service ● ● ● ● ● ● ● ● ●<br />

System Log ● ● ● ● ● ● ● ● ●<br />

Relay Alarm ● ● ● ● ● ● ● ● -<br />

SNMP Trap ● ● ● ● ● ● ● ● ●<br />

DHCP Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server Client/ Server<br />

DNS Client/ Server ● ● ● ● ● ● ● ● ●<br />

TFTP Firmware Update/ Backup /Resotre ● ● ● ● ● ● ● ● ●<br />

Configuration upload and download ● ● ● ● ● ● ● ● ●<br />

ifAlias ● ● ● ● ● ● - - -<br />

ORDERING INFORMATION (part number)<br />

IES-2008A IES-2206F-II IES-2208C IES-2208F IES-2216C IES-2307C IGS-2206C IGS-2404 LES-2400-RPS<br />

-20°C~60°C<br />

-20°C~60°C, AC input<br />

-40°C~75°C<br />

-40°C~75°C, AC input<br />

-40°C~75°C, DNV Type<br />

8350-2302<br />

8350-2302-AC<br />

8350-2312<br />

8350-2312-AC<br />

-<br />

8350-2208 (MM, 2KM)<br />

8350-2258 (SM, 30KM)<br />

8350-2208-AC (MM, 2KM)<br />

8350-2258-AC (SM, 30KM)<br />

8350-2218 (MM, 2KM)<br />

8350-2268 (SM, 30KM)<br />

8350-2218-AC (MM, 2KM)<br />

8350-2268-AC (SM, 30KM)<br />

-<br />

-<br />

8350-450<br />

8350-450-AC<br />

8350-440<br />

8350-440-AC<br />

8350-410 (SC, MM, 2KM)<br />

8350-412 (ST, MM, 2KM)<br />

8350-415 (SC, SM, 30KM)<br />

8350-655-AC<br />

-<br />

8350-419DNV-AC (SC, MM)<br />

-40°C~75°C, DNV Type, AC input - - 8350-655DNV-AC<br />

-<br />

-<br />

8350-418DNV-AC (SC, SM)<br />

-<br />

-<br />

8350-410-AC (SC, MM)<br />

8350-412-AC (ST, MM)<br />

8350-415-AC (SC, SM)<br />

8350-411 (SC, MM, 2KM)<br />

8350-413 (ST, MM, 2KM)<br />

8350-416 (SC, SM, 30KM)<br />

8350-411-AC (SC, MM)<br />

8350-413-AC (ST, MM)<br />

8350-416-AC (SC, SM)<br />

8350-419DNV (SC, MM)<br />

8350-418DNV (SC, SM)<br />

8350-650<br />

8350-650-AC<br />

8350-655<br />

8350-655DNV<br />

8350-460<br />

8350-460-AC<br />

8350-465<br />

8350-465-AC<br />

-<br />

8350-604<br />

8350-604-AC<br />

8350-640<br />

8350-640-AC<br />

-<br />

8350-800<br />

8350-800-AC<br />

8350-850<br />

8350-850-AC<br />

-<br />

-<br />

8220-600<br />

-<br />

-<br />

-<br />

8220-600DNV<br />

(-20°C~60°C)<br />

-<br />

P26


Industrial PoE Switches<br />

Fully compliant with IEEE 802.3af PoE standard,<br />

<strong>Lantech</strong> Industrial PoE Switches provide<br />

comprehensive PoE solution with durability and<br />

reliability. It can adjust power output at each port for<br />

12.9w (15.4w) or 16.5w (22.6w).<br />

Industrial Ethernet Switches<br />

IPEC-0101FT<br />

1 10/100TX to 100M-FX Slim Type<br />

Media Converter w/PoE injector<br />

IPES-2208C<br />

8 10/100TX + 2 10/100/1000T/Dual<br />

Speed SFP Combo w/8 PoE Injector<br />

Pro-Ring Industrial Managed Switch<br />

Technology Highlights:<br />

What is PoE?<br />

It’s a system to safely pass electrical<br />

power, along with data, on Ethernet<br />

cabling. Standard versions of PoE specify<br />

CAT. 5 cable or higher. Power can come<br />

from a power supply within a PoE-enabled<br />

networking device such as an Ethernet<br />

switch or from a device built for<br />

"injecting" power onto the Ethernet<br />

cabling.<br />

IPES-0005T-4<br />

5 10/100TX w/4 PoE Injector<br />

Industrial Switch<br />

IPES-2224C-24<br />

24 10/100TX + 2 100/1000T/SFP<br />

Combo w/24 PoE Injector Pro-Ring<br />

Industrial Managed Switch<br />

Power levels available<br />

IPES-0008-4<br />

8 10/100TX w/4 PoE Injector<br />

24~48VDC Industrial Switch<br />

- UL508<br />

- 24~48VDC Power Input<br />

Pro-Ring<br />


HARDWARE FEATURES<br />

Port<br />

IPEC-0101FT IPES-0005T-4 IPES-0104FT IPES-0008-4 IPES-2208C IPES-2224C-24<br />

10/100TX 1 5 4 8 8 24<br />

100FX 1 (SC) - 1 (SC) - - -<br />

1000FX - - - - - -<br />

10/100/1000T - - - - - -<br />

100M SFP - - - - - -<br />

1000M SFP - - - - - -<br />

10/100/1000T/Dual Speed SFP Combo - - - - 2 2 (1000M SFP only)<br />

RS232 connector - - - - RJ-45 DB-9 Female<br />

PoE Injector 1 4 4 8 8 24<br />

Switching Fabric - 1.0Gbps 1.0Gbps 1.6Gbps 5.6Gbps 8.8Gbps<br />

Packet Buffer - 448Kbits 448Kbits 56Kbytes 1Mbits 4Mbits<br />

Jumbo Frame - - - - - 9Kbytes<br />

Mac Address 2K 2K 2K 2K 8K 8K<br />

Flash ROM - - - - 4Mbytes 4Mbytes<br />

DRAM - - - - 32Mbytes 32Mbytes<br />

Power Supply<br />

*Optional<br />

48VDC (45~56VDC) 48VDC (45~56VDC) 48VDC (45~56VDC) 24/ 48VDC 48VDC (45~56VDC) 48VDC (45~56VDC)<br />

Redundant Power ● ● ● ● ● ●<br />

Power Consumption 3.3 Watts 5.4 Watts 6.6 Watts 1.9/ 2.4 Watts NA 15.76 Watts<br />

Overload Current Protection ● ● ● ● ● ●<br />

Polarity Reverse Protection Polarity Protection Polarity Protection Polarity Protection Polarity Protection Polarity Protection Polarity Protection<br />

Relay Contact with Alarm System ● ● ● ● ● ●<br />

DIDO (Digital Input/ Digital Output) - - - - - -<br />

Standard Operating Temperature<br />

-20°C~60°C / -4°F~140°F<br />

● ● ● - ● -<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

● ● - ● ● ●<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

● ● ● ● ● ●<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

● ● ● ● ● ●<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 48.6 x 140 x 95 72 x 105 x 152 440 x 280 x 44<br />

Case Protection IP30 IP30 IP30 IP30 IP30 IP30<br />

Weight 600g 648g 824g 670g 1418g 3700g<br />

DIN Rail Installation ● ● ● ● ● -<br />

Wall Mount Installation ● ● ● ● ● -<br />

19-inch Rack Mount - - - - - ●<br />

CE/ FCC/ UL ● ● ● CE/ FCC/ UL508 ● ●<br />

RoHS/ WEEE ● ● ● ● ● ●<br />

UL Class I Division II Certification - - - ● - -<br />

Stability Testing (Free fall/ Shock/ Vibration) ● ● ● ● ● ●<br />

MTBF 391,515 hours 443,153 hours 259,356 hours 241,413 hours 190,288 hours 133,495 hours<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ●<br />

Web Browser ● ●<br />

Telnet ● ●<br />

CLI ● ●<br />

<strong>Lantech</strong>-View ● ●<br />

IGMP snooping v1 v2/ IGMP query ● ●<br />

VLAN ● ●<br />

Port Trunk with LACP ● ●<br />

LLDP ● ●<br />

Port Security ● ●<br />

IP Security ● ●<br />

Login Security (RADIUS) ● ●<br />

SNTP ● ●<br />

SMTP 6 e-mail accounts 6 e-mail accounts<br />

Bandwidth Control ● ●<br />

Flow Control ● ●<br />

Pro-Ring System<br />

X-Ring ● ●<br />

Dual Homing ● ●<br />

Couple Ring ● ●<br />

Central Ring - ●<br />

Dual Ring ● -<br />

Spanning Tree/ RSTP ● ●<br />

Port Mirror ● ●<br />

Quality of Service ● ●<br />

Class of Service ● ●<br />

System Log ● ●<br />

Relay Alarm ● ●<br />

SNMP Trap ● ●<br />

DHCP Client/ Server Client/ Server<br />

DNS Client/ Server ● ●<br />

TFTP Firmware Update/ Backup /Resotre ● ●<br />

Configuration upload and download ● ●<br />

ifAlias ● ●<br />

ORDERING INFORMATION (part number)<br />

IPEC-0101FT IPES-0005T-4 IPES-0104FT IPES-0008-4 IPES-2208C IPES-2224C-24<br />

-20°C~60°C<br />

8350-900 (MM, 2KM)<br />

8350-910<br />

8350-911 (MM, 2KM)<br />

-<br />

8350-700<br />

-<br />

8350-901 (SM, 30KM) 8350-912 (SM, 30KM)<br />

-20°C~60°C, High Power Model - 8350-918 - - - -<br />

-40°C~75°C<br />

8350-905 (MM, 2KM)<br />

8350-916<br />

-<br />

8450-560<br />

8350-705<br />

8350-710<br />

8350-906 (SM, 30KM) -<br />

-40°C~75°C, High Power Model - 8350-919 - - - -<br />

P28


Industrial Smart-Ring Switches<br />

<strong>Lantech</strong> Smart-Ring series provides the redundant<br />

Pro-Ring 10ms protocol by enabled DIP switch or<br />

through Web GUI for self-heal. Each model also<br />

provides smart and easy functions including Port based<br />

VLANs, RSTP/STP, E-mail alert, SNMP Trap, DHCP, DNS<br />

client to satisfy the basic management requirements.<br />

Industrial Ethernet Switches<br />

IES-1005T<br />

5 10/100TX Smart Industrial<br />

Ethernet Switch w/Pro-Ring<br />

IES-1204FT<br />

4 10/100TX + 2 100SFP Smart<br />

Industrial Ethernet Switch<br />

w/Pro-Ring<br />

DIP-Switch Setting<br />

When power fault enable relay warning system<br />

P.F.<br />

(On : Enable, Off : Disable function)<br />

R.E.<br />

R.M.<br />

R.S.<br />

Enable/Disable Ring function (On : Enable, Off : Disable)<br />

Enable/Disable Ring Master Mode (On : Enable, Off : Disable)<br />

Ring redundant port select (On : ring port set to port-1 and port-5,<br />

Off : ring port set to port-1 and port-2)<br />

HARDWARE FEATURES<br />

Port<br />

IES-1005T<br />

IES-1204FT<br />

10/100TX 5 4<br />

100M SFP - 2<br />

Switching Fabric 1.0Gbps 1.2Gbps<br />

Packet Buffer 1Mbits 1Mbits<br />

Mac Address 2K 2K<br />

Power Supply<br />

*Optional<br />

24VDC (9~56VDC) 24VDC (9~56VDC)<br />

Redundant Power ● ●<br />

Power Consumption 3 Watts 7 Watts<br />

Overload Current Protection ● ●<br />

Polarity Reverse Protection ● ●<br />

Relay Contact with Alarm System ● ●<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

●<br />

●<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

●<br />

●<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

●<br />

●<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

26.1 x 95 x 144.3 26.1 x 95 x 144.3<br />

Case Protection IP30 IP30<br />

Weight 395g 395g<br />

DIN Rail Installation ● ●<br />

Wall Mount Installation ● ●<br />

CE/ FCC ● ●<br />

RoHS/ WEEE ● ●<br />

Stability Testing (Free fall/ Shock/ Vibration) ● ●<br />

MTBF 390,800 hours 383,478 hours<br />

Warranty 5 years 5 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ●<br />

Web Browser ● ●<br />

<strong>Lantech</strong>-View ● ●<br />

Pro-Ring<br />


Industrial Entry Switches<br />

<strong>Lantech</strong> Industrial Entry Switches are unmanaged models which are designed to meet the demands of<br />

industrial network for Plug-and-Play usage. Each model is in a robust IP 30 housing and has been<br />

tested extensively to meet with Industrial EMI / EMC standards and UL safety.<br />

IES-0005T<br />

5 10/100TX Slim Type<br />

Industrial Switch<br />

- UL C1D2<br />

- DNV<br />

IES-0216C<br />

16 10/100TX + 2 10/100/1000T/<br />

Giga or 100M SFP Combo<br />

Industrial Switch<br />

HARDWARE FEATURES<br />

Port<br />

IES-0008T<br />

8 10/100TX Slim Type<br />

Industrial Switch<br />

- UL C1D2<br />

- DNV<br />

IGS-0008T<br />

8 10/100/1000T<br />

Industrial Switch<br />

- UL C1D2<br />

IES-0104FT<br />

4 10/100TX + 1 100FX<br />

Industrial Switch<br />

- DNV (Pending)<br />

IP30 -40°C<br />

to<br />

+75°C<br />

IES-0204FT<br />

4 10/100TX + 2 100FX<br />

Industrial Switch<br />

- DNV (Pending)<br />

Redundant<br />

Power Supply<br />

9-56V<br />

5Years<br />

Warranty<br />

IES-0005T IES-0008T IES-0104FT IES-0204FT IES-0216C IGS-0008T<br />

10/100TX 5 8 4 4 16 -<br />

100FX - - 1 (SC) 2 (SC) - -<br />

10/100/1000T - - - - - 8<br />

10/100/1000T/Dual Speed SFP Combo - - - - 2 -<br />

Switching Fabric 1.0Gbps 1.6Gbps 1.0Gbps 1.2Gbps 7.2Gbps 16Gbps<br />

Packet Buffer 448Kbits 448Kbits 448Kbits 448Kbits 1Mbits 176Kbytes<br />

Jumbo Frame - - - - - 9.6Kbytes<br />

Mac Address 2K 2K 2K 2K 8K 8K<br />

Power Supply<br />

*Optional<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

24VDC (9~56VDC)<br />

12~36VAC*<br />

Redundant Power ● ● ● ● ● ●<br />

Power Consumption 2.93 Watts 4.71 Watts 4.44 Watts 6.41 Watts 9 Watts 7.39 Watts @ 48V<br />

Overload Current Protection ● ● ● ● ● ●<br />

Polarity Reverse Protection ● ● ● ● ● ●<br />

Relay Contact with Alarm System ● ● ● ● ● ●<br />

Industrial Ethernet Switches<br />

Standard Operating Temperature<br />

-20°C~60°C / -4°F~140°F<br />

● ● ● ● ● ●<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

● ● ● ● ● ●<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

● ● ● ● ● ●<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

● ● ● ● ● ●<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 72 x 105 x 152 30 x 95 x 140<br />

Case Protection IP30 IP30 IP30 IP30 IP30 IP30<br />

Weight 430g 480g 800g 810g 1300g 500g<br />

DIN Rail Installation ● ● ● ● ● ●<br />

Wall Mount Installation ● ● ● ● ● ●<br />

CE/ FCC/ UL ● ● CE/ FCC CE/ FCC ● ●<br />

RoHS/ WEEE ● ● ● ● ● ●<br />

UL Class I Division II Certification ● ● - - - -<br />

DNV Type Approved ● ● ● ● - -<br />

Stability Testing (Free fall/ Shock/ Vibration) ● ● ● ● ● ●<br />

MTBF 412,590 hours 388,566 hours 380,717 hours 347,014 hours 243,301 hours 585,810 hours<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years<br />

ORDERING INFORMATION (part number)<br />

-20°C~60°C<br />

-20°C~60°C, AC input<br />

-40°C~75°C<br />

-40°C~75°C, AC input<br />

-40°C~75°C, DNV Type<br />

-40°C~75°C, DNV Type, AC input<br />

IES-0005T IES-0008T IES-0104FT IES-0204FT IES-0216C IGS-0008T<br />

8350-330 (MM, 2KM) 8350-340 (MM, 2KM)<br />

8350-630<br />

8350-620<br />

8350-651<br />

8350-830<br />

8350-331 (SM, 30KM) 8350-341 (SM, 30KM)<br />

8350-330-AC (MM, 2KM) 8350-340-AC (MM, 2KM)<br />

8350-630-AC<br />

8350-620-AC<br />

8350-651-AC<br />

8350-830-AC<br />

8350-331-AC (SM, 30KM) 8350-341-AC (SM, 30KM)<br />

8350-335 (MM, 2KM) 8350-345 (MM, 2KM)<br />

8350-632<br />

8350-621<br />

8350-656<br />

8350-831<br />

8350-336 (SM, 30KM) 8350-346 (SM, 30KM)<br />

8350-335-AC (MM, 2KM) 8350-345-AC (MM, 2KM)<br />

8350-632-AC<br />

8350-621-AC<br />

8350-656-AC<br />

8350-831-AC<br />

8350-336-AC (SM, 30KM) 8350-346-AC (SM, 30KM)<br />

8350-335DNV (MM, 2KM) 8350-345DNV (MM, 2KM)<br />

8350-632DNV<br />

8350-621DNV<br />

-<br />

-<br />

8350-336DNV (SM, 30KM) 8350-346DNV (SM, 30KM)<br />

8350-335DNV-AC (MM, 2KM) 8350-345DNV-AC (MM, 2KM)<br />

8350-632DNV-AC<br />

8350-621DNV-AC<br />

-<br />

-<br />

8350-336DNA-AC (SM, 30KM) 8350-346DNV-AC (SM, 30KM)<br />

P30


Industrial Converters Series<br />

Featured with the unique DIP switch for LLF and duplex<br />

mode, <strong>Lantech</strong> Industrial Converters provide the most<br />

convenient choice with reliability. Each model is<br />

designed to meet the demands of harsh industrial<br />

environments with robust IP 30 housing. The series has<br />

also been tested extensively to meet with EMI / EMC<br />

standards and UL safety.<br />

Industrial Ethernet Converters<br />

IEC-0101FT<br />

1 10/100TX to 100M-FX<br />

Slim Type Converter<br />

IGC-0101GB<br />

10/100/1000T to Mini-GBIC<br />

Industrial Switch Converter<br />

IPEC-0101FT<br />

1 10/100TX to 100M-FX<br />

Slim Type Media Converter<br />

w/PoE injector<br />

HARDWARE FEATURES<br />

Port<br />

IEC-0101FT-SC IEC-0101FT-ST IGC-0101GB IPEC-0101FT IVC-0101<br />

10/100TX 1 1 - 1 1<br />

100FX 1 (SC) 1 (ST) - 1 (SC) -<br />

10/100/1000T - - 1 - -<br />

1000M SFP - - 1 - -<br />

- - - - RJ-45*1<br />

VDSL<br />

with Female Phone Jack<br />

PoE Injector - - - 1 -<br />

Jumbo Frame - - 9Kbytes - -<br />

Mac Address 2K 2K 2K 2K -<br />

Power Supply<br />

24VDC (9~56VDC)<br />

24VDC (9~56VDC)<br />

24VDC (9~56VDC)<br />

24VDC (9~56VDC)<br />

48VDC (45~56VDC)<br />

*Optional<br />

12~36VAC*<br />

12~36VAC*<br />

12~36VAC*<br />

24VAC<br />

Redundant Power ● ● ● ● ●<br />

Power Consumption 2.74 Watts 2.74 Watts 5.3 Watts 3.3 Watts<br />

4.8 Watts (48VDC)<br />

7.7 Watts (24VAC)<br />

Overload Current Protection ● ● ● ● ●<br />

Polarity Reverse Protection ● ● ● Polarity Protection ●<br />

Relay Contact with Alarm System ● ● ● ● ●<br />

Standard Operating Temperature<br />

-20°C~60°C / -4°F~140°F<br />

Wide Operating Temperature<br />

-40°C~75°C / -40°F~167°F<br />

Storage Temperature<br />

-40°C~85°C / -40°F~185°F<br />

Operating Humidity<br />

5% to 95% (Non-condensing)<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

● ● ● ● -<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

● ● ● ● ●<br />

30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140 30 x 95 x 140<br />

Case Protection IP30 IP30 IP30 IP30 IP30<br />

Weight 600g 600g 600g 600g 600g<br />

DIN Rail Installation ● ● ● ● ●<br />

Wall Mount Installation ● ● ● ● ●<br />

CE/ FCC/ UL ● ● ● ● CE/ FCC/ UL508<br />

RoHS/ WEEE ● ● ● ● ●<br />

UL Class I Division II Certification ● ● ● - ●<br />

DNV Type Approved ● ● - - -<br />

Stability Testing (Free fall/ Shock/ Vibration) ● ● ● ● ●<br />

MTBF 405,486 hours 405,486 hours 525,424 hours 391,515 hours -<br />

Warranty 5 years 5 years 5 years 5 years 5 years<br />

ORDERING INFORMATION (part number)<br />

-20°C~60°C<br />

-20°C~60°C, AC input<br />

-40°C~75°C<br />

-40°C~75°C, AC input<br />

-40°C~75°C, DNV Type<br />

-40°C~75°C, DNV Type, AC input<br />

IEC-0101FT-SC IEC-0101FT-ST IGC-0101GB IPEC-0101FT IVC-0101<br />

8350-020 (MM,2KM) 8350-022 (MM,2KM) 8350-900 (MM,2KM)<br />

8350-002 (MM,5KM) 8350-003 (MM,5KM) 8350-050<br />

8350-901 (SM,30KM)<br />

8350-021 (SM,30KM) - -<br />

8350-020-AC (MM,2KM) 8350-022-AC (MM,2KM)<br />

-<br />

8350-002-AC (MM,5KM) 8350-003-AC (MM,5KM)<br />

8350-050-AC<br />

-<br />

8350-021-AC (SM,30KM) -<br />

-<br />

8350-025 (MM,2KM) 8350-023 (MM,2KM) 8350-905 (MM,2KM)<br />

8350-004 (MM,5KM) 8350-005 (MM,5KM) 8350-055<br />

8350-906 (SM,30KM)<br />

8350-026 (SM,30KM) - -<br />

8350-025-AC (MM,2KM)<br />

8350-004-AC (MM,5KM)<br />

8350-023-AC (MM,2KM)<br />

8350-005-AC (MM,5KM)<br />

8350-026-AC (SM,30KM) -<br />

8350-055-AC<br />

8350-025DNV (MM,2KM) 8350-023DNV (MM,2KM) -<br />

8350-004DNV (MM,5KM) 8350-005DNV (MM,5KM) -<br />

-<br />

8350-026DNV (SM,30KM) - -<br />

8350-025DNV-AC (MM,2KM) 8350-023DNV-AC (MM,2KM) -<br />

8350-004DNV-AC (MM,5KM) 8350-005DNV-AC (MM,5KM) -<br />

-<br />

8350-026DNV-AC (SM,30KM) - -<br />

-<br />

-<br />

-<br />

-<br />

8350-030<br />

-<br />

IVC-0101<br />

1 10/100TX to VDSL2<br />

Industrial Converter<br />

IP30 -40°C<br />

to<br />

+75°C<br />

Redundant<br />

Power Supply<br />

9-56V<br />

5Years<br />

Warranty<br />

P31


Universal Redundant Fiber Controller<br />

The <strong>Lantech</strong> Universal Redundant Fiber Controller<br />

provides a permanent and trouble-free access port for<br />

in-line network devices. The controller automatically<br />

switches network traffic through added in-line devices<br />

or bypasses devices that are about to be removed.<br />

Prevent link failure when attached in-line devices lose<br />

power by powering the controller and in-line device<br />

from the same power source.<br />

IFR-0202-LC<br />

Universal Redundant<br />

LC Fiber Controller<br />

HARDWARE FEATURES<br />

Port<br />

IFR-0202-SC<br />

Universal Redundant<br />

SC Fiber Controller<br />

IFR-0202-ST<br />

Universal Redundant<br />

ST Fiber Controller<br />

IP30 -5°C<br />

to<br />

+70°C<br />

Redundant<br />

Power Supply<br />

9-56V<br />

5Years<br />

Warranty<br />

IFR-0202-LC-MM IFR-0202-LC-SM IFR-0202-SC-MM IFR-0202-SC-SM IFR-0202-ST-MM IFR-0202-ST-SM<br />

In-Line 2 2 2 2 2 2<br />

Network 2 2 2 2 2 2<br />

Connector Type LC LC SC SC ST ST<br />

Fiber Type Multi-mode Single-mode Multi-mode Single-mode Multi-mode Single-mode<br />

Corning 62.5/ 125μm 9/ 125μm 62.5/ 125μm 9/ 125μm 62.5/ 125μm 9/ 125μm<br />

Wavelength 850nm 1300~1550nm 850nm 1300~1550nm 850nm 1300~1550nm<br />

Insertion Loss<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Max 1.6dB<br />

(Bypass Mode)<br />

Power 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC)<br />

Redundant Power ● ● ● ● ● ●<br />

LED Power Status Power Status Power Status Power Status Power Status Power Status<br />

Operating Temperature<br />

-5°C~70°C<br />

-5°C~70°C<br />

-5°C~70°C<br />

-5°C~70°C<br />

-5°C~70°C<br />

-5°C~70°C<br />

23°F~158°F<br />

23°F~158°F<br />

23°F~158°F<br />

23°F~158°F<br />

23°F~158°F<br />

23°F~158°F<br />

Storage Temperature<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°F~185°F<br />

-40°F~185°F<br />

-40°F~185°F<br />

-40°F~185°F<br />

-40°F~185°F<br />

-40°F~185°F<br />

Operating Humidity (Non-condensing) 10%~90% 10%~90% 10%~90% 10%~90% 10%~90% 10%~90%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3 50.6 x 95.4 x 140.3<br />

Case Protection IP30 IP30 IP30 IP30 IP30 IP30<br />

Weight 500g 500g 500g 500g 500g 500g<br />

DIN Rail Installation ● ● ● ● ● ●<br />

Wall Mount Installation ● ● ● ● ● ●<br />

CE/ FCC/ UL ● ● ● ● ● ●<br />

RoHS/ WEEE ● ● ● ● ● ●<br />

MTBF - - - - - -<br />

Warranty 5 years 5 years 5 years 5 years 5 years 5 years<br />

ORDERING INFORMATION (part number)<br />

*The insertion loss is less than 1dB when the switch receiving power and is in Normal mode<br />

IFR-0202-LC-MM IFR-0202-LC-SM IFR-0202-SC-MM IFR-0202-SC-SM IFR-0202-SC-SM IFR-0202-ST-SM<br />

8800-140 8800-141 8800-145 8800-146 8800-147 8800-148<br />

Universal Redundant Fiber Controller<br />

Technology Highlights: How does Universal Redundant Fiber Controller work?<br />

Normal status<br />

Bypass status<br />

Power Fail<br />

Switch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202 Switch IFR-0202<br />

P32


Industrial Wireless Access Point<br />

The <strong>Lantech</strong> high quality access point series ensure the<br />

most reliable wireless connectivity from basic IP30<br />

model to high-end IP68/65 model. The three models<br />

provide different software features for comprehensive<br />

network plans. All models support IEEE 802.11a/b/g<br />

standard with PoE. Integrated with <strong>Lantech</strong> switches,<br />

we are able to provide total solutions without<br />

boundary.<br />

Industrial Wireless Access Point<br />

IWP-1000<br />

Industrial 802.11 a/b/g<br />

Redundant Access Point<br />

Technology Highlights:<br />

What is MESH?<br />

IWP-2000-65<br />

Industrial 802.11 a/b/g<br />

IP65 Redundant Access Point<br />

w/MESH<br />

IWP-2000-68<br />

Industrial 802.11 a/b/g<br />

IP68 Redundant Access Point<br />

w/MESH<br />

IP 30<br />

65<br />

68<br />

A wireless mesh network is a communications network which often consists of mesh clients, mesh routers and gateways. A mesh network<br />

is reliable and offers redundancy securely and cost effectively for enterprises and end users. When one node can no longer operate, the<br />

rest of the nodes can still communicate with each other, directly or through one or more intermediate nodes. In areas that do not support<br />

a wired backhaul, <strong>Lantech</strong> provides the wireless mesh network solution for seamless roaming beyond traditional WLAN boundaries with<br />

easy deployment.<br />

-10°C<br />

to<br />

+55°C<br />

-20°C<br />

to<br />

+70°C<br />

5Years<br />

Warranty<br />

P33


HARDWARE FEATURES<br />

IWP-1000 IWP-2000-65 IWP-2000-68<br />

Data Rates<br />

Standards<br />

802.11b: 1, 2, 5.5, 11 Mbps<br />

802.11g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps<br />

802.11a: 6, 9, 12, 18, 24, 36, 48, 54 Mbps<br />

IEEE802.11 a/b/g,<br />

IEEE802.1x,<br />

IEEE802.3,<br />

IEEE802.3u,<br />

IEEE802.3af<br />

802.11b: 1, 2, 5.5, 11 Mbps<br />

802.11g: 6,9,12,18,24,36,48,54 Mbps<br />

802.11a: 6,9,12,18,24,36,48,54 Mbps<br />

IEEE802.11 a/b/g,<br />

IEEE802.1x,<br />

IEEE802.3,<br />

IEEE802.3u,<br />

IEEE802.3af<br />

802.11b: 1, 2, 5.5, 11 Mbps<br />

802.11g: 6,9,12,18,24,36,48,54 Mbps<br />

802.11a: 6,9,12,18,24,36,48,54 Mbps<br />

IEEE802.11 a/b/g,<br />

IEEE802.1x,<br />

IEEE802.3,<br />

IEEE802.3u,<br />

IEEE802.3af<br />

Interface 2* 10/100TX RJ45 (for PoE) 1* 10/100TX RJ45 (for PoE) 1* 10/100TX RJ45 (for PoE)<br />

Flash 8M bytes 16M bytes 16M bytes<br />

Memory 32MB 64 MB SDRAM 64 MB SDRAM<br />

Power Requirements<br />

RF Information<br />

Output power (± 1.5dBm)<br />

Sensitivity<br />

(Typical)<br />

12~48 VDC on terminal block<br />

with Reverse Polarity Protection<br />

IEEE802.11a/b/g : 20dBm max<br />

-81dBm @ 11Mbps, PER< 8%;<br />

-64dBm @ 54Mbps, PER< 10%<br />

Active Ethernet (Power over Ethernet)<br />

48 VDC/0.375A<br />

External Unit: Auto sensing<br />

100/240 VAC; 50/60 Hz<br />

802.11a<br />

24dBm@6Mps<br />

22dBm@36Mps<br />

21dBm@48Mps<br />

20dBm@54Mps<br />

802.11b<br />

26dBm@11Mps<br />

802.11g<br />

26dBm@6~24Mps<br />

25dBm@36Mps<br />

24dBm@48Mps<br />

23dBm@54Mps<br />

802.11a<br />

-92dBm @ 6Mbps, -72dBm @ 54Mbps<br />

802.11b<br />

-95dBm @ 1Mbps, -90dBm @ 11Mbps<br />

802.11g<br />

-92dBm @ 6Mbps, -73dBm @ 54Mbps<br />

Active Ethernet (Power over Ethernet)<br />

48 VDC/0.375A<br />

External Unit: Auto sensing<br />

100/240 VAC; 50/60 Hz<br />

802.11a<br />

24dBm@6Mps<br />

22dBm@36Mps<br />

21dBm@48Mps<br />

20dBm@54Mps<br />

802.11b<br />

26dBm@11Mps<br />

802.11g<br />

26dBm@6~24Mps<br />

25dBm@36Mps<br />

24dBm@48Mps<br />

23dBm@54Mps<br />

802.11a<br />

-92dBm @ 6Mbps, -72dBm @ 54Mbps<br />

802.11b<br />

-95dBm @ 1Mbps, -90dBm @ 11Mbps<br />

802.11g<br />

-92dBm @ 6Mbps, -73dBm @ 54Mbps<br />

Operating Temperature<br />

-10°C~55°C<br />

-20°C~70°C<br />

-20°C~70°C<br />

14°F~131°F<br />

-4°F~158°F<br />

-4°F~158°F<br />

Storage Temperature<br />

-40°C~85°C<br />

-40°C~80°C<br />

-40°C~80°C<br />

-40°F~185°F<br />

-40°F~176°F<br />

-40°F~176°F<br />

Operating Humidity (Non-condensing) 5%~95% 5%~95% 5%~95%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

52 x 106 x 144 230 x 230 x 60 230 x 230 x 60<br />

Case Protection IP30 IP65 IP68<br />

Weight 800g 1200g 3000g<br />

DIN Rail Installation ● - -<br />

Wall Mount Installation ● - -<br />

Pole Mount Installation - ● ●<br />

CE/ FCC/ UL CE/ FCC CE/ FCC CE/ FCC<br />

RoHS/ WEEE ● ● ●<br />

Stability Tests (Free fall/ Shock/ Vibration) ● ● ●<br />

MTBF - - -<br />

Warranty 5 years 5 years 5 years<br />

SOFTWARE FEATURES<br />

Management<br />

IP Auto-configuration DHCP client/ server DHCP client/ server DHCP client/ server<br />

SNMP V1/ V2 V1/ V2c/ V3 V1/ V2c/ V3<br />

NTP server Support NTP client Support NTP client Support NTP client<br />

Remote Configuration<br />

Web‐based configuration (HTTP)<br />

• Web‐based configuration (HTTP)<br />

• Telnet<br />

• Web‐based configuration (HTTP)<br />

• Telnet<br />

Max Client up to 64 users (simultaneously) per radio 32 users (simultaneously) per radio 32 users (simultaneously) per radio<br />

Network management - <strong>Lantech</strong>-View Pro <strong>Lantech</strong>-View Pro<br />

Operation Mode<br />

AP, Bridge, Repeater, AP-Client, Client<br />

MESH_AP (OLSR), MESH_AP (AODV), AP-<br />

Bridge, AP-CB-Bridge, AP-CB- route, CB-CBroute,<br />

VLAN-AP , WDS (Repeater)<br />

MESH_AP (OLSR), MESH_AP (AODV), AP-<br />

Bridge, AP-CB-Bridge, AP-CB- route, CB-CBroute,<br />

VLAN-AP , WDS (Repeater)<br />

SSID ● Multiple SSID Multiple SSID<br />

Security<br />

• WEP 64-bit, 128-bit key supported<br />

• WPA-WiFi Protected Access<br />

• WPA2 (802.11i)<br />

• PSK (256-bit key pre-shared key supported)<br />

• IEEE802.1x / RADIUS<br />

• TKIP encryption<br />

• MAC address filtering<br />

• IEEE802.1x / RADIUS Client (TTLS, PEAP)<br />

Support in AP Mode<br />

• IEE802.1x Supplicant (TTLS, PEAP)<br />

Support in Client Bridge Mode<br />

• WPA-WiFi Protected Access<br />

• WPA2 (802.11i)<br />

• WEP 64,128 bits<br />

• MAC address filtering<br />

• Layer2 Isolation<br />

• VLAN tunneling Support<br />

• Hide SSID<br />

• IEEE802.1x / RADIUS Client (TTLS, PEAP)<br />

Support in AP Mode<br />

• IEE802.1x Supplicant (TTLS, PEAP)<br />

Support in Client Bridge Mode<br />

• WPA-WiFi Protected Access<br />

• WPA2 (802.11i)<br />

• WEP 64,128 bits<br />

• MAC address filtering<br />

• Layer2 Isolation<br />

• VLAN tunneling Support<br />

• Hide SSID<br />

LLDP ● ● ●<br />

AP Scan ● ● ●<br />

STP/RSTP ● ● ●<br />

QoS - WMM WMM<br />

Mac Filter Setting 30 Mac Address Setting 15 Mac Address Setting 15 Mac Address<br />

Bandwidth limitation -<br />

Traffic shaping by IP for each client in Route<br />

mode only 30 list<br />

Traffic shaping by IP for each client in Route<br />

mode only 30 list<br />

Firmware Upgrade WEB WEB and TFTP/FTP WEB and TFTP/FTP<br />

ORDERING INFORMATION (part number)<br />

IWP-1000 IWP-2000-65 IWP-2000-68<br />

8810-555 8810-885 8810-888<br />

P34


Central Managed Switches<br />

<strong>Lantech</strong> business grade managed switches provide fully<br />

management functions with Pro-Ring system, which<br />

ensures the highest network redundancy. The modular<br />

fiber high density switches provide fiber aggregation<br />

points with flexible configuration.<br />

Central Managed Switches<br />

LGS-2300-RPS<br />

3-Gigabit-Modular-Slots Chassis L2 +<br />

Managed Switch with 12-48V DC<br />

Redundant Power Supply Socket<br />

Technology Highlights:<br />

What is IGMP?<br />

LES-2400-RPS<br />

3 Slots 10/100M Modularized + 2 x<br />

Gigabit Combo L2 Plus Managed<br />

Switch w/Redundant Power Supply<br />

- Pro-Ring<br />

LGS-2816C-RPS<br />

16 100/1000M SFP<br />

+ 8 10/100/1000TX Combo<br />

L2 Plus Managed Switch<br />

w/Redundant Power Supply<br />

LGS-2424C<br />

24 10/100/1000T with 4 1000SFP<br />

shared cage SNMP Managed Switch<br />

Power Supply<br />

100<br />

to<br />

240 VAC 2Years<br />

Warranty<br />

The Internet Group Management<br />

Protocol (IGMP) is a<br />

communications protocol used to<br />

manage the membership of<br />

Internet Protocol multicast groups.<br />

IGMP is used by IP hosts and<br />

adjacent multicast routers to<br />

establish multicast group<br />

memberships. IGMP is only<br />

needed for IPv4 networks, as<br />

multicast is handled differently in<br />

IPv6 networks. IP Multicast is an<br />

application where needs IGMP<br />

Query and IGMP Snooping. In IP<br />

Multicasting network, a Query<br />

mode must be enabled first<br />

otherwise the switch would not<br />

know that group members exist.<br />

Query mode is usually built in a L3<br />

router. <strong>Lantech</strong> Industrial Switch is<br />

built-in with IGMP Query and<br />

Snooping mode to fill specific<br />

needs, so they are the best to be<br />

used in Transportation, Factory<br />

Automation, Warehouse, Traffic<br />

Control, Community Surveillance<br />

applications.<br />

IP TV figure<br />

IP TV Viewer<br />

IP TV Viewer<br />

IP TV Viewer<br />

Surveillance figure<br />

IP TV Viewer<br />

Leave<br />

Switch<br />

Switch<br />

Join<br />

Leave<br />

Join<br />

Switch<br />

Switch<br />

Server<br />

Media MMS Server<br />

IP Camera<br />

IP Camera<br />

P35


LGS-2300-RPS LES-2400-RPS LGS-2816C-RPS LGS-2424C<br />

HARDWARE FEATURES<br />

Port<br />

10/100TX - Max 24 - -<br />

100FX - Max 24 - -<br />

10/100/1000T Max 24 - - 20<br />

100M SFP - Max 24 -<br />

1000M SFP Max 24 -<br />

16 (Dual Speed SFP)<br />

-<br />

10/100/1000T/1000M SFP Combo - 2 8 (Dual Speed SFP) 4<br />

RS232 connector DB-9 Female DB-9 Female DB-9 Female DB-9 Female<br />

Switching Fabric 48Gbps 8.8Gbps 48Gbps 48Gbps<br />

Packet Buffer 6Mbits 4Mbits 1392KB 500Kbytes<br />

Jumbo Frame 10KB 9K (for Gigabit Ports) 9K 10K<br />

Mac Address 16K 8K 8K 8K<br />

Flash ROM 8Mbytes - 128M ROM: 512Kbytes x 2<br />

DRAM - - 512M RAM: 128Kbytes<br />

System Memory 32Mbytes - - -<br />

Power Supply<br />

100~240VAC,<br />

50/60Hz<br />

100~240VAC,<br />

50/60Hz<br />

100~240VAC,<br />

50/60Hz<br />

Redundant Power 12~48VDC 12~48VDC 12+VDC -<br />

100~240VAC,<br />

50/60Hz<br />

Power Consumption 35 Watts 18 Watts 40 Watts 17.9 Watts<br />

Operating Temperature<br />

0°C~45°C<br />

-20°C~60°C<br />

0°C~40°C<br />

0°C~45°C<br />

32°F~113°F<br />

-4°F~140°F<br />

32°F~104°F<br />

32°F~113°F<br />

Storage Temperature<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

Operating Humidity (Non-condensing) 5%~95% 5%~95% 5%~90% 10%~95%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

440 x 280 x 44 440 x 200 x 44 442 x 209 x 44 440 x 161 x 44<br />

Weight 4900g 5000g 2900g 3200g<br />

19-inch Rack Mount ● ● ● ●<br />

CE/ FCC/ UL ● ● CE/ FCC ●<br />

RoHS/ WEEE ● ● ● ●<br />

DNV Type Approved - ● - -<br />

MTBF 85,203 hours 75,900 hours - 143,964 hours<br />

Warranty 2 years 2 years 2 years 2 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 v1 v2c ● ● v1<br />

Web Browser ● ● ● ●<br />

Telnet ● ● ● ●<br />

CLI ● ● ● ●<br />

<strong>Lantech</strong>-View - - - -<br />

Menu Driven - - - -<br />

IGMP snooping v1 v2/ IGMP query v3 (Optional) ● ● ●<br />

VLAN ● ● ● ●<br />

Port Trunk with LACP ● ● ● ●<br />

LLDP ● ● ● -<br />

Port Security ● ● ● -<br />

IP Security ● ● ● ●<br />

Login Security (RADIUS) ● ● ● ●<br />

TACACS+ - - ● -<br />

SNTP ● ● NTP -<br />

SMTP 5 e-mail accounts 6 e-mail accounts 6 e-mail accounts -<br />

Bandwidth Control ● ● ● ●<br />

Flow Control ● ● ● ●<br />

Pro-Ring System<br />

X-Ring - ● - -<br />

Dual Homing - ● - -<br />

Couple Ring - ● - -<br />

Spanning Tree/ RSTP<br />

STP/ RSTP/<br />

MSTP (Optional)<br />

STP/ RSTP/<br />

MSTP (Optional)<br />

STP/ RSTP/ MSTP<br />

Port Mirror ● ● ● ●<br />

Quality of Service ● ● ● ●<br />

Class of Service ● ● ● ●<br />

System Log ● ● ● -<br />

SNMP Trap ● ● ● ●<br />

DHCP Client/ Server Client/ Server Client/ Server Client<br />

DNS Client/ Server ● ● ● -<br />

TFTP Firmware Update/ Backup /Resotre ● ● ● ●<br />

Configuration upload and download ● ● ● ●<br />

●<br />

ORDERING INFORMATION (part number)<br />

LGS-2300-RPS LES-2400-RPS LGS-2816C-RPS LGS-2424C<br />

Standard model 8370-550 8220-600 8370-900 8370-502<br />

DNV model - 8220-600DNV - -<br />

8 100TX Module - 8220-510 - -<br />

8 100SFP Module - 8220-570 - -<br />

8 GigaT Module 8370-560 - - -<br />

8 GigaSFP Module 8370-590 - - -<br />

4 GT + 4 SFP Module 8370-595 - - -<br />

P36


Smart Switches<br />

<strong>Lantech</strong> smart series Web Management switches with<br />

4, 8 10/100/1000T ports specially designed for the<br />

small office or department where require high<br />

bandwidth. With the Web UI, users are able to manage<br />

smart series, which supports port based VLAN, VLAN<br />

Tag and port trunk features. They also support CoS to<br />

improve the security and performance of the network.<br />

<strong>Lantech</strong> Smart series is the best solution for the users<br />

in aspect of easy management and budget concern.<br />

HARDWARE FEATURES<br />

Port<br />

LGS-1108C<br />

LGS-1104<br />

10/100/1000T 7 4<br />

1000M SFP - 1<br />

10/100/1000T/1000M SFP Combo 1 -<br />

Switching Fabric 16Gbps 10Gbps<br />

Packet Buffer 144Kbytes 112Kbytes<br />

Jumbo Frame 9Kbytes 8Kbytes<br />

Mac Address 8K 8K<br />

Flash ROM - ROM: 512Kbytes<br />

DRAM - RAM: 32Kbytes<br />

Power Supply<br />

100~240VAC,<br />

50/60Hz<br />

100~240VAC,<br />

50/60Hz<br />

Power Consumption 3.75 Watts 5.1 Watts<br />

Smart Switches<br />

LGS-1108C<br />

8 10/100/1000T with 1 1000SFP<br />

shared cage Web Managed Switch<br />

Web<br />

Management<br />

LGS-1104<br />

4 10/100/1000T + 1mini GBIC Web<br />

Managed Switch<br />

0°C<br />

to<br />

Power Supply<br />

100<br />

+45°C<br />

to<br />

2Years<br />

240 VAC Warranty<br />

Operating Temperature<br />

0°C~45°C<br />

0°C to 45°C<br />

32°F~113°F<br />

32°F to 113°F<br />

Storage Temperature<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°F~158°F<br />

-40°F~158°F<br />

Operating Humidity (Non-condensing) 10%~90% 10%~90%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

217 x 140 x 43 165 x 100 x 32.5<br />

Weight 1060g 900g<br />

19-inch Rack Mount 10-inch Rack -<br />

CE/ FCC/ UL ● CE/ FCC<br />

RoHS/ WEEE ● ●<br />

MTBF 126,420 hours 304,057 hours<br />

Warranty 2 years 2 years<br />

SOFTWARE FEATURES<br />

Management<br />

Web Browser ● ●<br />

VLAN ● ●<br />

Port Trunk with LACP ● ●<br />

Login Security (RADIUS) ● ●<br />

Flow Control ● ●<br />

Spanning Tree/ RSTP ● ●<br />

Port Mirror - -<br />

Quality of Service ● ●<br />

Class of Service ● ●<br />

DHCP Client Client<br />

TFTP Firmware Update/ Backup /Resotre web UI web UI<br />

Configuration upload and download ● ●<br />

ORDERING INFORMATION (part number)<br />

LGS-1108C LGS-1104<br />

Standard model 8370-700 8370-145<br />

Technology Highlights:<br />

What is RSTP?<br />

In 1998, the IEEE with document 802.1w<br />

introduced an evolution of the Spanning<br />

Tree Protocol: Rapid Spanning Tree<br />

Protocol (RSTP), which provides for faster<br />

spanning tree convergence after a<br />

topology change. Standard IEEE<br />

802.1D-2004 now incorporates RSTP and<br />

obsoletes STP. While STP can take 30 to 50<br />

seconds to respond to a topology change,<br />

RSTP is typically able to respond to<br />

changes within 3*Hello (default is 6<br />

seconds).<br />

RSTP<br />

Symbol Number Description<br />

1 Router<br />

5 Switch<br />

1 PC<br />

3 User<br />

3 Mainframe<br />

P37


PoE Series<br />

<strong>Lantech</strong> PoE series includes<br />

fully-managed switches,<br />

splitters and injectors,<br />

providing a total PoE solution<br />

for our customers. Fully<br />

complies with IEEE802.3af PoE<br />

standard, <strong>Lantech</strong> PoE series is<br />

integrating “Pro-Ring” to<br />

double secure the network,<br />

and equipped with IGMP<br />

Query and snooping function<br />

for IGMP applications where<br />

can release the video network<br />

burden immediately.<br />

LPES-2224CA<br />

24 10/100TX + 2 1000T/SFP Combo<br />

w/24 PoE Injector Managed Switch<br />

LPES-2208CA<br />

8 10/100TX + 2 100/1000 Dual SFP<br />

Combo Managed Switch w/8 PoE<br />

Injectors<br />

- Pro-Ring < 10ms<br />

POA-100A<br />

Single Port POE Power Source<br />

Injector with Internal Power<br />

HARDWARE FEATURES<br />

Port<br />

LPES-2224CA LPES-2208CA POA-100A POS-100A<br />

10/100TX 24 8 1 1<br />

10/100/1000T/1000M SFP Combo 2 2 (Dual Speed SFP) - -<br />

RS232 connector DB-9 Female DB-9 Female - -<br />

PoE Injector 24 8 1 -<br />

Switching Fabric 8.8Gbps 5.6Gbps - -<br />

Packet Buffer 3Mbits 1Mbits - -<br />

Mac Address 8K 8K - -<br />

Flash ROM 512Kbytes x 2 - - -<br />

System Memory 8Mbytes - - -<br />

100~240VAC, 100~240VAC, 100~240VAC,<br />

Power Input<br />

48VDC/0.3A<br />

50/60Hz<br />

50/60Hz<br />

50/60Hz<br />

Per port feeding Per port feeding<br />

Power Output<br />

power: 15.4Watts power: 15.4Watts 15.4W 48VDC, 0.32A 5V(2.4A),9V(1.3A),12V<br />

(1A); Maximum 12W<br />

(maximum)<br />

(maximum)<br />

Power Consumption 20 Watts 10 Watts 3.6 Watts -<br />

Operating Temperature<br />

0°C to 45°C<br />

0°C~45°C<br />

0°C~45°C<br />

-10°C to 45°C<br />

32°F to 113°F 32°F~113°F<br />

32°F~113°F<br />

14°F to 113°F<br />

Storage Temperature<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

Operating Humidity (Non-condensing) 10%~95% 5%~95% 5%~95% 10%~95%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

440 x 280 x 44 217 x 140 x 43 117 x 60 x 35 55 x 80 x 31<br />

Weight 3810g 1632g - 76g<br />

Wall Mount Installation - ● - -<br />

19-inch Rack Mount ● 10-inch Rack - -<br />

CE/ FCC/ UL ● CE/ FCC ● CE/ FCC<br />

RoHS/ WEEE ● ● ● ●<br />

MTBF 57,586 hours 175,813 hours - -<br />

Warranty 2 years 2 years 2 years 2 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP v1 v2c v3 ● ● - -<br />

Web Browser ● ● - -<br />

Telnet ● ● - -<br />

CLI ● ● - -<br />

IGMP snooping v1 v2/ IGMP query ● ● - -<br />

VLAN ● ● - -<br />

Port Trunk with LACP ● ● - -<br />

LLDP - ● - -<br />

Port Security ● ● - -<br />

IP Security - ● - -<br />

Login Security (RADIUS) ● ● - -<br />

SNTP ● ● - -<br />

SMTP - 6 e-mail accounts - -<br />

Bandwidth Control ● ● - -<br />

Flow Control ● ● - -<br />

Pro-Ring System<br />

X-Ring - ● - -<br />

Dual Homing - ● - -<br />

Couple Ring - ● - -<br />

PoE Series<br />

POS-100A<br />

Adjustable output Power<br />

Over Ethernet Splitter<br />

2Years<br />

Warranty<br />

Spanning Tree/ RSTP ● ● - -<br />

Port Mirror ● ● - -<br />

Quality of Service - ● - -<br />

Class of Service ● ● - -<br />

System Log ● ● - -<br />

SNMP Trap ● ● - -<br />

DHCP Client Client/ Server - -<br />

DNS Client/ Server - ● - -<br />

TFTP Firmware Update/ Backup /Resotre ● ● - -<br />

Configuration upload and download - ● - -<br />

ORDERING INFORMATION (part number)<br />

LPES-2224CA LPES-2208CA POA-100A POS-100A<br />

Standard model 8450-145 8450-540 8450-350 8450-220<br />

Technology Highlights:<br />

What are injector and splitter?<br />

<strong>Lantech</strong> injector is designed with 802.3af PoE compliant chip in<br />

which it will send impedance to handshake the correspondent<br />

PD in prior to deliver 48V power and prevent from burn down<br />

any non-POE devices.<br />

<strong>Lantech</strong> splitter is splits data and power signal over same Ethernet UTP cable<br />

and transfer input 48V (PoE standard) to 3 kinds voltages to meet with each<br />

PD needs. The inside PoE chip can correspond to PoE impedance signal sent<br />

by PoE injector or PSE (Power Source) to handshake with PoE standard first<br />

and then to deliver 48V power to drive PD, in which it prevents the risk of<br />

burning down the PD.<br />

P38


Serial Devices<br />

The <strong>Lantech</strong> serial device, which is able to convert at<br />

least one serial port (RS232/422/485) to Ethernet or<br />

USB connection, enables user to remotely manage and<br />

configure device servers via Internet.<br />

Serial Devices<br />

IDS-2101F<br />

1 RS-232/422/485 port<br />

to 1 100FX<br />

Ethernet Device Server<br />

IDS-2102<br />

1 RS-232/422/485 port<br />

to 2 10/100TX<br />

Ethernet Device Server<br />

IDS-2204<br />

4 RS-232/422/485 port<br />

to 2 10/100TX<br />

Ethernet Device Server<br />

DS-Tool<br />

LSC-1102<br />

Ethernet To RS-232/ 422/ 485<br />

Serial Device<br />

- With Isolation<br />

LSC-0101U<br />

USB To RS-422/ 485<br />

Serial Device<br />

• Broadcast discovery device<br />

• Device server status monitoring<br />

• VCOM management<br />

• Multi-Wizard function<br />

• Device setting function<br />

Technology Highlights:<br />

What is DS-Tool?<br />

DS-Tool is Windows-base powerful device server management<br />

software. With its friendly and powerful interface, you can easily<br />

configure multiple device servers at the same time, and monitor<br />

status. DS-Tool contains the following abilities:<br />

1. Device discovery<br />

2. Auto IP report<br />

3. Device setting (run-time change, no rebooting)<br />

4. Access control list<br />

5. Group setting<br />

6. Device monitoring<br />

7. Serial port monitoring<br />

8. Log info<br />

9. Group Firmware update batch<br />

P39


HARDWARE FEATURES<br />

Port<br />

IDS-2101F IDS-2102 IDS-2204 LSC-0101U LSC-1102<br />

LAN 1 (100FX) 2 (10/100TX) 2 (10/100TX) - 1 (10/100TX)<br />

Serial Ports<br />

1 (RS-232/ 422 /485)<br />

1 (RS-232/ 422/ 485) 4 (RS-232/ 422 /485)<br />

1 (RS-422/ 485)<br />

Port 1: RS-232<br />

Port 2: RS-232/ 422/ 485<br />

USB - - - 1 -<br />

LAN Type SC Fiber RJ45 RJ45 - RJ45<br />

Serial Type male DB-9, S/W selectable male DB-9, S/W selectable male DB-9, S/W selectable Terminal Block DB-9 + Terminal Block<br />

USB Type - - -<br />

USB type A<br />

(Complies to USB 1.0, 1.1, 2.0)<br />

-<br />

DIP Switch ● ● - ● 9/ 125μm<br />

Beeper ● ● ● - -<br />

Power 24VDC (9~56VDC) 24VDC (9~56VDC) 24VDC (9~56VDC) USB Bus Power ( 5V ) 9~24VDC, 500mA<br />

Power Consumption 4 Watts 4 Watts 5.5 Watts - -<br />

Redundant Power ● ● ● - -<br />

Overload Current Protection ● ● ● - -<br />

Polarity Reverse Protection ● ● ● - -<br />

LED ● ● ● ● ●<br />

Operating Temperature<br />

-20°C~60°C<br />

-20°C~60°C<br />

-20°C~60°C<br />

0°C~60°C<br />

-10°C~70°C<br />

-4°F~140°F<br />

-4°F~140°F<br />

-4°F~140°F<br />

32°F~140°F<br />

14°F~158°F<br />

Storage Temperature<br />

-40°C~85°C<br />

-40°C~85°C<br />

-40°C~85°C<br />

-20°C~85°C<br />

-20°C~85°C<br />

-40°F~185°F<br />

-40°F~185°F<br />

-40°F~185°F<br />

-4°F~185°F<br />

-4°F~185°F<br />

Operating Humidity (Non-condensing) 5%~95% 5%~95% 5%~95% 5%~95% 10%~90%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

72 x 29.4 x 123.4 72 x 29.4 x 123.4 52 x 106.1 x 144.3 55 x 40 x 29 90 x 60 x 20<br />

Case Protection IP30 IP30 IP30 - -<br />

Weight 325 g 327 g 678 g 35 g 100 g<br />

DIN Rail Installation ● ● ● - ●<br />

Wall Mount Installation ● ● ● - ●<br />

CE/ FCC/ UL CE/ FCC CE/ FCC CE/ FCC CE/ FCC CE/ FCC<br />

RoHS/ WEEE ● ● ● ● ●<br />

Stability Tests (Free fall/ Shock/ Vibration) ● ● ● ● ●<br />

MTBF - - 533,615 hours - -<br />

Warranty 5 years 5 years 5 years 1 years 1 years<br />

SOFTWARE FEATURES<br />

Management<br />

SNMP ● ● ● - -<br />

Web ● ● ● - ●<br />

DS-Tool ● ● ● - -<br />

Telnet ● ● ● - ●<br />

Protocols<br />

Security<br />

ICMP, IP, TCP, UDP, DHCP, BootP,<br />

ARP/RARP, Telnet, RTelnet, DNS,<br />

SNMP, MIB II, HTP, SMTP, SNTP<br />

HTTPS, SSH v2, SSL v3<br />

(data encryption)*<br />

ICMP, IP, TCP, UDP, DHCP, BootP,<br />

ARP/RARP, Telnet, RTelnet, DNS,<br />

SNMP, MIB II, HTP, SMTP, SNTP<br />

HTTPS, SSH v2, SSL v3<br />

(data encryption)*<br />

ICMP, IP, TCP, UDP, DHCP, BootP,<br />

ARP/RARP, Telnet, DNS, SNMP MIB<br />

II, SMTP SNTP<br />

-<br />

ARP, IP, ICMP, UDP, TCP, HTTP,<br />

DHCP, Telnet<br />

HTTPS, SSH, SSL (data encryption) - Login Password<br />

Email notification ● ● ● - -<br />

SNMP Trap ● ● ● - -<br />

Serial API Function<br />

ORDERING INFORMATION (part number)<br />

Port Control<br />

Input/output Data<br />

Port Status Inquiry<br />

Port Control<br />

Input/output Data<br />

Port Status Inquiry<br />

- - -<br />

IDS-2101F IDS-2102 IDS-2204 LSC-0101U LSC-1102<br />

8425-001 (MM, 2KM)<br />

8425-002 (SM, 30KM)<br />

8425-010<br />

8425-020<br />

8425-008<br />

8425-006<br />

*Optional<br />

P40


Fiber Converters<br />

<strong>Lantech</strong> converter series provides the flexibility for the<br />

users to covert network connection between fiber port<br />

and RJ-45 port. The Multi-Converter Chassis for 10<br />

converters is also available, which provides<br />

plug-and-play and hot-swappable features.<br />

Fiber Converters<br />

CM-011 Fiber<br />

With SC connector<br />

Multi/Single-mode<br />

Multi-Converter Chassis<br />

10 slots Converter Chassis<br />

CM-011 Fiber<br />

With ST connector<br />

Multi/Single-mode<br />

CM-011 Fiber<br />

With WDM connector<br />

Single-mode<br />

CM-011 DIP-Switch Setting<br />

CM-021-GB-II<br />

10/100/1000BaseT<br />

to Gigabit Fiber<br />

Media Converter<br />

-Jumbo Frame 9K<br />

1 UTP Auto-Nego / 100Mbps Full Duplex mode<br />

2 Fiber Full/Half Duplex<br />

3 LLF (Link Lose Forwarding) Disable/Enable<br />

4 Switch Converter / Pure converter mode<br />

CM-021 DIP-Switch Setting<br />

1 LLF Enable / LLF Disable<br />

2 Pure converter mode / Switch converter mode<br />

3 Reserved / Reserved<br />

0°C<br />

to<br />

+45°C<br />

Power Supply<br />

9 VDC<br />

2Years<br />

Warranty<br />

Technology Highlights:<br />

What is Multi-Converter Chassis?<br />

<strong>Lantech</strong> Multi-Converter Chassis provides<br />

not only 10 independent converter slots,<br />

but also one optional extra redundant<br />

power supply. There are various modules<br />

to satisfy the demand of users, which<br />

include Fiber converter series (with LLF<br />

function) and Gigabit converter series. All<br />

the converters and redundant power<br />

supply supports plug-and-play and<br />

hot-swappable features which allow user<br />

to plug or pull out the converters/<br />

redundant power supply without<br />

rebooting the chassis.<br />

Power budget = Output power - Sensitivity<br />

Item MMF SMF<br />

Core Diameter 50 or 62.5 um 9 um<br />

Bandwidth 10G Un - limited<br />

Distance 100M 2km 20 - 120km<br />

1Gbps<br />

500m (50 um)<br />

275m (62.5 um)<br />

CWDM / DWDM N/A YES<br />

Attenuation :<br />

1310nm : 0.4dB -0.45dB / km<br />

1550nm : 0.2dB -0.25dB / km<br />

10 - 120km<br />

Laser FP Laser FP(


CM-011-ST-MM CM-011-SC-MM CM-011-SC-MM-5KM CM-011-SC-SM-60KM CM-011-SC-SM-30KM CM-011-WDM13 CM-011-WDM15 CM-021-GB-II<br />

HARDWARE FEATURES<br />

Port<br />

10/100TX 1 1 1 1 1 1 1 -<br />

100FX ST, Multi-mode x 1 SC, Multi-mode x 1 SC, Multi-mode x 1 SC, Single-mode x 1 SC, Single-mode x 1 LC, Tx 1310nm, WDM x 1 LC, Tx 1550nm, WDM x 1 -<br />

10/100/1000T - - - - - - - 1<br />

1000M SFP - - - - - - - 1<br />

Jumbo Frame - - - - - - - 9Kbytes<br />

Power Supply DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A DC9V / 0.7A<br />

Power Consumption 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.1 Watts 3.8 Watts<br />

Operating Temperature<br />

0°C~45°C<br />

0°C~45°C<br />

0°C~45°C<br />

0°C~45°C<br />

0°C~45°C<br />

0°C~45°C<br />

0°C~45°C<br />

0°C to 45°C<br />

32°F~113°F<br />

32°F~113°F<br />

32°F~113°F<br />

32°F~113°F<br />

32°F~113°F<br />

32°F~113°F<br />

32°F~113°F<br />

32°F to 113°F<br />

Storage Temperature<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°C~70°C<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

-40°F~158°F<br />

Operating Humidity (Non-condensing) 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95% 10%~95%<br />

Case Dimension<br />

W x D x H (unit=mm)<br />

119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26 119 x 85 x 26<br />

Weight 740g 740g 740g 740g 740g 740g 740g 754g<br />

19-inch Rack Mount ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis ● with Chassis<br />

CE/ FCC/ UL ● ● ● ● ● ● ● ●<br />

RoHS/ WEEE ● ● ● ● ● ● ● ●<br />

MTBF 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 111,076 hours 443,282 hours<br />

Warranty 2 years 2 years 2 years 2 years 2 years 2 years 2 years 2 years<br />

ORDERING INFORMATION (part number)<br />

CM-011-ST-MM CM-011-SC-MM CM-011-SC-MM-5KM CM-011-SC-SM-60KM CM-011-SC-SM-30KM CM-011-WDM13 CM-011-WDM15 CM-021-GB-II<br />

8421-150 8421-151 8421-155 8421-170 8421-171 8421-180 8421-181<br />

8421-232<br />

Mini-GBIC<br />

Specifically designed for the high performance integrated data link, <strong>Lantech</strong> miniGBIC series provides a<br />

variety of Small Form Factor Pluggable (SFP) transceiver modules. The series covers 1.25Gbps/ 125Mbps for<br />

the distance from 100m to 120km with long MTBF, which ensures the durability.<br />

SFP 125Mbps<br />

Part Number Wavelength LD IO LOS Mode Link Temp.<br />

8330-060 1310nm FP AC/AC TTL Multi-mode 2km -10~70°C<br />

8330-065 1310nm FP AC/AC TTL Multi-mode 5km -10~70°C<br />

8330-061 1310nm FP AC/AC TTL Single-mode 30km -10~70°C<br />

SFP 1.25Gbps<br />

Part Number Wavelength LD IO LOS Mode Link Temp.<br />

8330-162 850 nm VCSEL 550m -10~70°C<br />

Multi-mode<br />

8330-163 1310 nm FP 2km -10~70°C<br />

8330-165 1310 nm FP 10km -10~70°C<br />

8340-0591 1310 nm DFB 40km -10~70°C<br />

AC/AC<br />

TTL<br />

8330-166 1550 nm DFB 50km -10~70°C<br />

Single-mode<br />

8330-169 1550 nm DFB 60km -10~70°C<br />

8330-167 1550 nm DFB 80km -10~70°C<br />

8330-170 1550 nm DFB 120km -10~70°C<br />

SFP 1000T<br />

Part Number<br />

Description<br />

8330-168<br />

1000Base-T, SFP, 100m, 3.3V, -10~70°C<br />

8330-168-E<br />

1000Base-T, SFP, 100m, 3.3V, -40~85°C<br />

BiDi SFP 1.25Gbps/125Mbps<br />

Part Number TX LD RX IO LOS Link Temp.<br />

8330-188 FP 10km<br />

8330-186 FP 20km<br />

1310nm<br />

8330-180 DFB 40km -10~70°C<br />

8330-181 DFB 60km<br />

8330-184 1490nm DFB 80km<br />

1550nm<br />

8330-188-E FP 10km<br />

8330-186-E FP 20km<br />

1310nm<br />

8330-180-E DFB 40km -40~85°C<br />

8330-181-E DFB 60km<br />

8330-184-E 1490nm DFB 80km<br />

AC/AC<br />

TTL<br />

8330-189 10km<br />

8330-187 20km<br />

1310nm<br />

8330-182 40km -10~70°C<br />

8330-183 60km<br />

8330-185 1490nm 80km<br />

1550nm<br />

DFB<br />

8330-189-E<br />

10km<br />

8330-187-E<br />

20km<br />

1310nm<br />

8330-182-E<br />

40km -40~85°C<br />

8330-183-E<br />

60km<br />

8330-185-E 1490nm 80km<br />

125Mbps/1.25Gbps Dual-rate<br />

Part Number Wavelength LD IO LOS Mode Link Temp.<br />

8330-191 1310nm FP AC/AC TTL Single-mode 10km -10~70°C<br />

8330-191-E 1310nm FP AC/AC TTL Single-mode 10km -40~85°C<br />

Technology Highlights:<br />

What is DDM?<br />

DDM(Digital Diagnostic Monitoring) MSA<br />

function are provided with voltage,<br />

temperature, TX power, RX power and<br />

laser bias current over the network.<br />

DDM function enables central site to<br />

remote monitor each fiber link quality<br />

with ease.<br />

P42


Power and Accessories<br />

<strong>Lantech</strong> power with DIN Rail series is rigid and compact<br />

for space saving and industrial applications. It supports<br />

power ready signal and ring diode circuit for redundant<br />

application as well as over-voltage, over-load and short<br />

circuit protection. The series provides various models<br />

which cover different output voltages and currents.<br />

Power and Accessories<br />

AD1024F<br />

24Watts,<br />

Single Output Power<br />

with DIN Rail<br />

DIN Rail Power<br />

Model<br />

O/P voltage<br />

Adjustment<br />

AD1048FS<br />

48Watts,<br />

Single Output Power<br />

with DIN Rail<br />

AD1120F<br />

120Watts,<br />

Dual Output Power<br />

with DIN Rail<br />

Loading (A)<br />

Ripple<br />

Overvoltage<br />

Line Reg. Load Reg. Efficiency<br />

Min. Rated Max. Noise Protection<br />

AD1024-24F +24VDC±10% 0A 1A 1A 150mVp-p ±1% ±1% 83% 40VDC Max<br />

AD1024-24F-E +24VDC±10% 0A 1A 1A 150mVp-p ±1% ±1% 83% 40VDC Max<br />

AD1024-48F +48VDC±10% 0A 0.5A 0.5A 250mVp-p ±1% ±1% 83% 60VDC Max<br />

AD1048-24FS +24VDC±10% 0A 2A 2A 150mVp-p ±1% ±1% 83% 40VDC Max<br />

AD1048-24FS-E +24VDC±10% 0A 2A 2A 150mVp-p ±1% ±1% 83% 40VDC Max<br />

AD1048-48FS +48VDC±10% 0A 1A 1A 250mVp-p ±1% ±1% 83% 60VDC Max<br />

AD1120-24F +24VDC±10% 0A 5A 5A 150mVp-p ±1% ±1% 81% 27~30VDC Max<br />

AD1120-48F +48VDC±10% 0A 2.5A 2.5A 550mVp-p ±1% ±1% 83% 52~56VDC Max<br />

AD1240-24S +24VDC±10% 0A 10A 10A 150mVp-p ±1% ±1% 83% 27~30VDC<br />

AD1240-48S +48VDC±10% 0A 5A 5A 250mVp-p ±1% ±1% 84% 52~56VDC<br />

Each output can supply maximum current, but loading cannot exceed rated output wattage.<br />

Note: 1. up to total<br />

2. Line regulation is measured from low line to high line at rated load.<br />

3. Load regulation is measured from 20% to 100% of rated load at 110VAC input.<br />

4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic capacitor parallel on the test point, at rated load and 110VAC input.<br />

5. Efficiency is measured at rated load and 110VAC input.<br />

AD1240S<br />

240Watts,<br />

Dual Output Power<br />

with DIN Rail<br />

Connector Power<br />

P-Fail<br />

Console<br />

M12 Connector<br />

M12 Cable<br />

M12 Connector / Cable<br />

Part Number<br />

Description<br />

ECON120005MM 5 Pin M12 Power Male Connector<br />

ECON120004FF 4 Pin M12 RJ45 Female Connector<br />

ECON120003FF 3 Pin M12 Relay Female Connector<br />

ECAB125030F0 5 Pin M12 Power Female 3M Cable<br />

ECAB122030M0 3 Pin M12 Relay Male 3M Cable<br />

ECAB124030MJ 4 Pin M12 RJ45 Male 3M Cable<br />

ECAB124030MM 4 Pin M12 Male-Male 3M Cable<br />

Bracket<br />

Part Number<br />

MBAK19001<br />

MBAK19002<br />

Description<br />

19” Rack Mounting Kit for 72x105x152mm Industrial Switch<br />

L-Bracket that can change 90 degree of DIN rail mounting<br />

19 inch Bracket<br />

L Bracket<br />

P43


Note<br />

Note<br />

P44


<strong>Lantech</strong> TM<br />

Pioneering Industrial and IP Networks<br />

<strong>Lantech</strong> Worldwide Offices<br />

Taiwan<br />

<strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong>, <strong>Inc</strong>.<br />

7F, No.45, Lane 188, Ruiguang Rd.,<br />

Neihu District, Taipei, Taiwan, 11491<br />

Tel: +886-2-2799-5589<br />

Fax: +886-2-2799-5579<br />

info@lantechcom.tw<br />

www.lantechcom.tw<br />

China<br />

<strong>Lantech</strong> China<br />

Room 1-1-801, Long-Range World,<br />

18 Suzhou Street, Beijing, China, 100080<br />

Tel: +86-10-5166-2266<br />

Fax: +86-10-5166-2255<br />

www.lantechcom.cn<br />

Europe<br />

<strong>Lantech</strong> <strong>Communications</strong> Europe GmbH<br />

Philipp-Kachel-Str. 42a<br />

63911 Klingenberg / Germany<br />

Tel: +49-9372-9451-111<br />

Fax: +49-9372-9451-112<br />

sales@lantechcom.eu<br />

www.lantechcom.eu<br />

India<br />

<strong>Lantech</strong> India<br />

Unit 208, Building No. 5, Sector III, Millenium<br />

Business Park, MAHAPE, NAVI MUMBAI – 400710<br />

Tel: +91-22-4018-6200<br />

Fax: +91-22-4018-6266<br />

sales@lantechcom.in<br />

www.lantechcom.in<br />

Korea<br />

<strong>Lantech</strong> <strong>Communications</strong> Korea<br />

#408, Century Officetel, 1589-5 Seocho3-Dong<br />

Seocho-Ku, Seoul, Korea, 137-876<br />

Tel: +82-2-3273-3379<br />

Fax: +82-2-3275-3912<br />

sales@lantech.kr<br />

www.lantech.kr<br />

United States<br />

<strong>Lantech</strong> USA LLC<br />

4309 Reeder drive, Carrollton, Texas 75010, USA<br />

Tel: +1-214-764-1710<br />

www.lantechcom.com<br />

Class I Division II<br />

for Group A,B,C,D<br />

©2011, <strong>Lantech</strong> <strong>Communications</strong> <strong>Global</strong>, <strong>Inc</strong>. All rights Reserved