Laboratory Electrodes - Windaus
Laboratory Electrodes - Windaus
Laboratory Electrodes - Windaus
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SCHOTT INSTRUMENTS<br />
LABORATORY ELECTRODES<br />
E<br />
pH<br />
mV<br />
°C<br />
µS/cm<br />
<strong>Laboratory</strong> <strong>Electrodes</strong><br />
Precise measurements in the<br />
laboratory and on site<br />
BlueLine<br />
pH<br />
mV<br />
°C<br />
µS/cm<br />
pH<br />
Made in Germany<br />
mV<br />
°C<br />
µS/cm
Content<br />
Welcome to Schott<br />
BlueLine<br />
BlueLine<br />
page<br />
5<br />
Application examples<br />
pH combination electrodes<br />
page<br />
8<br />
Further sensors<br />
specialists for exceptional applications<br />
page 10<br />
Tips and information<br />
page 12<br />
<strong>Laboratory</strong> electrodes<br />
Application recommendations<br />
page 14<br />
pH combination electrodes<br />
page 16<br />
Metal combination electrodes<br />
page 22<br />
Single electrodes<br />
pH glass electrodes/metal electrodes<br />
reference electrodes<br />
page 26<br />
Conductivity cells<br />
page 30<br />
Further sensors<br />
ammonia-, sodium- and oxygen electrodes<br />
resistance thermometers<br />
page 32<br />
Accessories<br />
Connection cables<br />
page 36<br />
Solutions<br />
page 38<br />
Electrolyte bridges/Accessories<br />
page 44<br />
Index<br />
Index<br />
Type-no. / Order-no.<br />
page 46
Welcome to SCHOTT<br />
SCHOTT BlueLine ®<br />
Precise measurements in the labo-<br />
The various pH glasses developed by Schott<br />
waste disposal or recycling in accordance<br />
Perfect function, elegant design<br />
ratory and on-site. With sensors from<br />
provide a high degree of measuring accura-<br />
with official regulations.<br />
The compact BlueLine range covers all the<br />
Schott.<br />
cy and reliability for all areas of application.<br />
usual measuring tasks in the laboratory.<br />
Schott is Europe’s leading special glass man-<br />
Do you have any questions about the use<br />
Reliable and quick measured-value adjust-<br />
ufacturer and is included in the top group of<br />
In practice, the Silamid ® reference system<br />
of Schott electrodes? We shall always be<br />
ment within a broad temperature range,<br />
these manufacturers worldwide.<br />
developed by Schott means less measuring<br />
glad to advise you for your specific applica-<br />
new membrane glass with extraordinary<br />
errors due to interference currents as well as<br />
tion.<br />
mechanical stability and improved gel<br />
We offer customer-oriented solutions for<br />
more stable measured-value indications<br />
electrolyte are only a few of the charac-<br />
sophisticated glass applications in the indus-<br />
under critical conditions. Long diffusion dis-<br />
teristics that speak for the functionality of<br />
try, health care and home sectors and are<br />
tances in the electrodes make the use of<br />
these electrodes. For electrodes with<br />
always in close contact with customers<br />
an additional heavy metal as a silver-ion bar-<br />
liquid electrolyte, the refilling opening is<br />
thanks to the presence of our production<br />
rier superfluous. This means improved<br />
tightly sealed with the innovative and<br />
and marketing companies in all of the<br />
measuring functions based on applied<br />
easy to use sliding plug.<br />
World’s key regions.<br />
environmental protection.<br />
On the following pages, we provide recom-<br />
For more than 60 years, Schott has been<br />
The most important factor for the quality<br />
mendations for the use of BlueLine elec-<br />
actively involved in the field of pH measure-<br />
of the measurement is the design of the<br />
trodes. Both the BlueLine electrodes and<br />
ment. Our sensors are tailor-made to suit<br />
diaphragm: Here the platinum diaphragm<br />
their accessories are readily available from<br />
your requirements and are known for their<br />
irrefutably stands for stable and quick<br />
your laboratory distributor.<br />
first-rate quality, reliability and long service<br />
measured-value adjustment in a very broad<br />
life. You will find an overview of these preci-<br />
range of use. The platinum diaphragm is<br />
If you have any questions about BlueLine or<br />
sion sensors for laboratory and field use<br />
very insensitive to flow and stirring condi-<br />
Wolfgang Knappek<br />
the use of Schott electrodes please feel free<br />
in this catalogue together with all the neces-<br />
tions. Together with additional types of<br />
to contact us.<br />
sary accessories.<br />
diaphragms, we provide the best solution<br />
for practically any measuring medium.<br />
Schott electrodes are manufactured with<br />
SCHOTT – GERÄTE GmbH<br />
great precision and the highest possible<br />
The plug head system developed by Schott<br />
Postfach 2480<br />
degree of care in accordance with the lat-<br />
in 1972 (also called S7 or S8) has proved its<br />
D 55014 Mainz<br />
est manufacturing methods and each<br />
reliability millions of times and has been<br />
Hattenbergstraße 10<br />
electrode must pass stringent final inspec-<br />
considered as being the unofficial European<br />
D 55122 Mainz<br />
tion quality requirements.<br />
standard for a long time. For sensors that<br />
provide more than simply the pH value,<br />
The Schott electrochemical sensors cover<br />
Schott has developed, in co-operation with<br />
all applications for measurements in aqueous<br />
well-known manufacturers of electrodes and<br />
Telefon: +49 (0) 61 31/66-5111<br />
solutions: for the determination of pH<br />
pH meters, the new 6-pole SMEK plug<br />
Telefax: +49 (0) 61 31/66-5001<br />
value, redox potential, silver-ion and halo-<br />
system. This plug system has also proved its<br />
genide-ion activity, dissolved oxygen,<br />
reliability many times in practice.<br />
ammonia, conductivity and temperature.<br />
For many years Schott has been taking back<br />
all used sensors from its own production<br />
and has ensured that they undergo correct<br />
4<br />
5
BlueLine<br />
Application examples<br />
BlueLine pH Redox Conductivity<br />
Plug head (f. cablel: e.g.: LB1A, LB1BNC) 22 pH 11 pH 13 pH 16 pH 21 pH 27 pH 31 Rx<br />
With fixed cable, DIN plug 23 pH 12 pH<br />
With fixed cable, BNC plug 25 pH 17 pH<br />
With temp. sensor (Pt1000), fixed cable, DIN plug 28 pH 18 pH<br />
With temp. sensor (NTC30k), fixed cable, DIN plug 24 pH 14 pH<br />
With temp. sensor (NTC30k), fixed cable, BNC plug 26 pH 15 pH<br />
With temp. sensor (NTC30k), fixed cable, 8-pole plug 41 LF 43 LF 48 LF<br />
Variants robust high performance precision micro stick in surface universal robust universal low<br />
acid, diluted ● ❍<br />
agar-agar gel ❍ ●<br />
aquarium water ● ● ❍ ❍ ● ❍<br />
aqueous media in general ❍ ● ❍ ❍ ❍ ●<br />
bacteria cultures ● ❍ ●<br />
beer ● ❍ ❍ ❍ ●<br />
boiler feed water ● ● ❍ ●<br />
bread<br />
●<br />
butter/margarin<br />
●<br />
cheese ● ❍<br />
coffee extract ● ❍ ●<br />
condensate ● ● ●<br />
cooling water ❍ ● ❍ ❍ ❍ ●<br />
cream ● ❍<br />
cyanide detoxication ● ❍ ● ❍ ●<br />
desalination/Ion exchange ● ● ●<br />
detergent ❍ ● ❍ ●<br />
disinfectant ● ❍ ● ❍ ●<br />
dispersion color ❍ ● ❍ ❍<br />
drinking water ● ❍ ❍ ❍ ●<br />
effluents in general ● ● ❍ ❍ ● ❍<br />
electroplating bath ● ❍ ●<br />
electroplating waste water ● ❍ ❍ ●<br />
emulsions, water-based ● ● ❍ ● ❍<br />
environmental analysis ● ❍ ● ❍ ❍<br />
extreme pH values ❍ ●<br />
fat ❍ ●<br />
fertilizer solution ● ❍ ❍ ●<br />
field measurements ● ❍ ● ❍<br />
fish<br />
●<br />
fixing baths ● ❍ ❍<br />
6<br />
BlueLine pH Redox Conductivity<br />
Variants robust high performance precision micro stick in surface universal robust universal low<br />
groundwater ● ● ❍ ●<br />
infusion solutions ❍ ● ❍ ●<br />
jam ● ❍<br />
kjeldahl distillation ● ❍<br />
lemonade ● ❍ ●<br />
low ionic strength samples ● ● ●<br />
lye, diluted ❍ ●<br />
measurement narrow vessels<br />
●<br />
milk ● ❍<br />
mineral water ❍ ● ❍ ●<br />
oil/water emulsion<br />
●<br />
organic percentile high ❍ ●<br />
paper<br />
●<br />
paper extract ● ❍ ●<br />
photographic developer ❍ ● ❍<br />
precision measurement ● ● ❍ ❍<br />
protein-containing liquid ● ● ●<br />
rainwater ● ● ❍ ●<br />
redox reaction/titration<br />
●<br />
salt solution/brine ● ❍ ❍<br />
sausage/meat ● ❍<br />
seawater ● ● ❍<br />
serum ● ❍ ● ❍ ●<br />
skin/leather<br />
●<br />
soap ● ❍ ❍ ●<br />
soil extract ❍ ● ❍ ❍ ❍ ● ❍<br />
sulfide-bearing media ❍ ●<br />
suspension, water-based ❍ ● ❍ ●<br />
swimming pool water ❍ ● ❍ ❍ ❍<br />
titration in aqueous media ● ❍ ❍ ❍<br />
toothpaste ❍ ● ❍<br />
TRIS buffer solution ● ❍<br />
ultra pure water ● ● ❍<br />
varnish (water-based) ❍ ● ❍<br />
vegetables/fruits ● ❍<br />
wine ● ❍ ❍<br />
yogurt ● ❍<br />
● recommended by Schott ❍ applicable 1) also see laboratory electrodes with H glass<br />
For some applications deviating recommendations are suggestive. Please also pay attention to material resistance of the sensor against measuring media.<br />
More sensors you will find in our laboratory program more behind. If you don‘t find your application, please ask us. By phone, fax or e-mail.<br />
7
BlueLine<br />
pH combination electrodes<br />
The robusts for<br />
common applications<br />
Order no. BlueLine Temperature Connection<br />
Type no. sensor integrated<br />
pH range: 0...14<br />
Temperature range: -5...+80 °C<br />
Shaft:<br />
Noryl, 12 mm Ø<br />
Shaft length L:<br />
120 mm<br />
Zero point: pH = 7.0 ± 0.3<br />
Diaphragm:<br />
fibre<br />
Reference system: Silamid ®<br />
Reference electrolyte: gel (KCl),<br />
low maintenance,<br />
not refillable<br />
Glass membrane form: cylinder<br />
Glass membrane<br />
resistance (25°C): 300 MΩ<br />
Membrane glass type: L<br />
28 512 9225 22 pH no plug head, suitable cable: e.g. LB 1 A, LB 1 BNC<br />
28 512 9233 23 pH no 1 m fixed cable with DIN plug 19 262<br />
28 512 9241 24 pH NTC 30 kΩ 1 m fixed cable with DIN plug 19 262 + banana plug<br />
28 512 9258 25 pH no 1 m fixed cable with BNC plug<br />
28 512 9266 26 pH NTC 30 kΩ 1 m fixed cable with BNC plug + banana plug<br />
28 512 9282 28 pH Pt 1000 1 m fixed cable with DIN plug 19 262 + banana plug<br />
L<br />
The high performance electrodes for<br />
demanding measurements<br />
Order no. BlueLine Temperature Connection<br />
Type no. sensor integrated<br />
pH range: 0...14<br />
Temperature range: -5...+100 °C<br />
Shaft:<br />
glass, 12 mm Ø<br />
Shaft length L:<br />
120 mm<br />
Zero point: pH = 7.0 ± 0.3<br />
Diaphragm:<br />
platinum<br />
Reference system: Silamid ®<br />
Reference electrolyte: KCl 3 mol/l<br />
Glass membrane form: cone<br />
Glass membrane<br />
resistance (25°C): 300 MΩ<br />
Membran glass type: A<br />
BlueLine<br />
28 pH<br />
BlueLine 22 pH<br />
BlueLine 23 pH<br />
BlueLine 24 pH<br />
BlueLine 25 pH<br />
BlueLine 26 pH<br />
BlueLine<br />
18 pH<br />
BlueLine 11 pH<br />
BlueLine 12 pH<br />
BlueLine 14 pH<br />
BlueLine 15 pH<br />
BlueLine 17 pH<br />
28 512 9114 11 pH no plug head, suitable cable: e.g. LB 1 A, LB 1 BNC<br />
28 512 9122 12 pH no 1 m fixed cable with DIN plug 19 262<br />
28 512 9147 14 pH NTC 30 kΩ 1 m fixed cable with DIN plug 19 262 + banana plug<br />
28 512 9155 15 pH NTC 30 kΩ 1 m fixed cable with BNC plug + banana plug<br />
28 512 9171 17 pH no 1 m fixed cable with BNC plug<br />
28 512 9188 18 pH Pt 1000 1 m fixed cable with DIN plug 19 262 + banana plug<br />
8<br />
9
BlueLine<br />
Further sensors<br />
The specialists for<br />
exceptional applications<br />
Zero point of<br />
pH electrodes pH = 7.0 ± 0.3<br />
Connection cable<br />
for pH-/redox<br />
electrodes e.g. LB 1 A,<br />
LB 1 BNC<br />
High precision electrode<br />
BlueLine 13 pH<br />
Micro electrode<br />
BlueLine 16 pH<br />
Stick-in electrode<br />
BlueLine 21 pH<br />
Glass shaft, screw ground joint diaphragm, electrolyte KCl 3 mol/l, Silamid ® reference system,<br />
sphere membrane, A glass, plug head, length 170 mm, 12 mm Ø, -5...+100 °C, 0...14 pH,<br />
order no. 28 512 9139<br />
Glass shaft, platinum diaphragm, electrolyte KCl 3 mol/l, Silamid ® reference system,<br />
cylinder membrane, L glass, plug head, length 40/80 mm, 12/5 mm Ø, -5...+100 °C, 0...14 pH,<br />
order no. 28 512 9163<br />
Glass shaft, hole diaphragm, Referid ® electrolyte, Silamid ® reference system, spear membrane,<br />
L glass, plug head, length 65/25 mm, 12/5 mm Ø, -5...+80 °C, 2...13pH,<br />
order no. 28 512 9217<br />
Surface electrode<br />
BlueLine 27 pH<br />
Glass shaft, KPG ® annular gap diaphragm, Referid ® electrolyte, Silamid ® reference system,<br />
flat membrane, L glass, plug head, length 120 mm, 12 mm Ø, -5...+50 °C, 2...13 pH,<br />
order no. 28 512 9274<br />
Redox electrode<br />
BlueLine 31 Rx<br />
Glass shaft, ceramic diaphragm, electrolyte KCl 3 mol/l, Silamid ® reference system,<br />
sensor platinum disk 4 mm Ø, plug head, length 120 mm, 12 mm Ø, -5...+100 °C,<br />
order no. 28 512 9311<br />
L<br />
Robust conductivity cell<br />
BlueLine 41 LF<br />
Plastic shaft, 2-pole cell, 1 m fixed cable with 8-pole plug, sensor VA pins, cell constant<br />
0.1 cm -1 , temperature sensor NTC 30 kΩ, length 120 mm, 12 mm Ø, -5...+80 °C,<br />
order no. 28 512 9414<br />
Universal conductivity cell<br />
BlueLine 43 LF<br />
Plastic shaft, 4-pole cell, 1 m fixed cable with 8-pole plug, sensor platinum layer, cell constant<br />
1.0 cm -1 , temperature sensor NTC 30 kΩ, length 120 mm, 12 mm Ø, -5...+80 °C,<br />
order no. 28 512 9439<br />
Conductivity cell<br />
for low-ionic media<br />
BlueLine 48 LF<br />
Plastic shaft, 4-pole cell, 1 m fixed cable with 8-pole plug, sensor platinum layer, cell constant<br />
0.1 cm -1 , temperature sensor NTC 30 kΩ, length 120 mm, 12 mm Ø, -5...+80 °C,<br />
order no. 28 512 9488<br />
BlueLine<br />
13 pH<br />
BlueLine<br />
16 pH<br />
BlueLine<br />
21 pH<br />
BlueLine<br />
27 pH<br />
BlueLine<br />
31 Rx<br />
BlueLine<br />
43 LF<br />
41 LF<br />
48 LF<br />
10<br />
11
Tips and information<br />
for successful measurements<br />
Sensors for all applications<br />
Storage<br />
buffer solutions. If buffer solutions from bot-<br />
est way to carry out the refilling operation<br />
Many different application conditions require the use of appropriate, specifically designed pH sensors.<br />
Redox sensors and pH sensors should be<br />
tles are used, the bottles must be closed im-<br />
is to pump the electrolyte solution into the<br />
For your application, you can select the electrode with the optimal pH glass and diaphragm.<br />
kept in the solution with which the reference<br />
mediately after use. The buffer solution used<br />
electrodes using a small dispensing bottle.<br />
electrode is also refilled (submerge up to the<br />
should never be put back into the bottle but<br />
pH glasses<br />
Diaphragm<br />
diaphragm). In most cases, this is KCl solu-<br />
must be discarded instead. If very accurate<br />
Cleaning<br />
Schott electrodes are manufactured with various pH glasses.<br />
An important factor for a reliable and reproducible pH mea-<br />
tion (3 mol/l, type no. L 300). Low-mainte-<br />
calibration is necessary, we recommend<br />
A soiled reference electrode should be emp-<br />
These have been optimised for your application and offer a<br />
surement is the selection of an electrode with a suitable<br />
nance electrodes are also kept in KCl solu-<br />
DIN single use ampoules that always contain<br />
tied, rinsed with electrolyte solution and<br />
high degree of measuring accuracy and reliability. Select the<br />
diaphragm:<br />
tion. Conductivity measuring cells, after<br />
fresh high precision solutions. Redox sensors<br />
then filled again with electrolyte solution.<br />
pH glass for your application:<br />
being cleaned and rinsed-off with distilled<br />
are not calibrated. Their proper function<br />
In case of soiling of the glass membrane or<br />
water, can be stored in a dry location.<br />
can be checked using the appropriate test<br />
diaphragm, it should be cleaned in order to<br />
pH glass<br />
Diaphragm<br />
solutions. For conductivity measuring cells,<br />
maintain the measuring function. Depend-<br />
N-glass: for general applications across the whole pH range<br />
Platinum diaphragm:<br />
universal, shows its strength espe-<br />
Measuring<br />
the cell constant should be checked and<br />
ing on the degree of soiling, only the glass<br />
A-glass: with short response time in drinking water, service<br />
cially with solutions containing<br />
With refillable pH sensors and redox sensors,<br />
adjusted at regular intervals with test solu-<br />
membrane or the glass membrane with<br />
water and waste water; for general application and<br />
solids and at extreme pH values and<br />
the refilling opening must be opened in<br />
tions. Greater variations in the cell constants<br />
the diaphragm is submerged in the cleaning<br />
in media with low ion content<br />
temperatures. It is ideal for titrations<br />
order to carry out the measurement. The<br />
are an indication of soiling or damage.<br />
solution. Cleaning agents that may have<br />
L-glass:<br />
for low temperatures and general applications<br />
and very insensitive to stirring.<br />
sensor is then submerged in the measuring<br />
penetrated into the electrode must not be<br />
H-glass: for high temperatures, in acid and alkaline range,<br />
Ceramic diaphragm:<br />
robust for general applications, low<br />
medium at least up to the diaphragm.<br />
Refilling<br />
allowed to get into the reference system; if<br />
even with high sodium-ion concentrations<br />
electrolyte outflow rate.<br />
With refillable sensors, it is important to pay<br />
Refillable pH sensors and redox sensors are<br />
required, the reference electrode must be<br />
S-glass:<br />
in hot alkaline media with good reproducibility and<br />
Ground joint<br />
preferred for liquids with high solids<br />
attention to the filling level of the electro-<br />
refilled with electrolyte solution so that the<br />
rinsed-off with distilled water and electrolyte<br />
short response time<br />
diaphragm:<br />
contents, easy to clean.<br />
lyte solution (see Refilling). Between mea-<br />
filling level of the electrolyte solution is at<br />
solution. Depending on the degree of soil-<br />
Fibre diaphragm:<br />
for robust, minimum-maintenance<br />
surements, the sensor should be rinsed-<br />
least 5 cm above the level of the measuring<br />
ing, the methods mentioned below are rec-<br />
electrodes. Preferred for general<br />
off with distilled water but not wiped off.<br />
medium. With BlueLine electrodes, the easi-<br />
ommended.<br />
applications and field measurments.<br />
Excess droplets can be carefully sponged-off.<br />
KPG ® annular gap<br />
on minimum-maintenance<br />
After being cleaned, the sensor should be<br />
diaphragm:<br />
electrodes, with symmetric annular<br />
Calibrating<br />
rinsed-off with distilled water, conditioned<br />
gap, insensitive to soiling.<br />
Since the measuring characteristics of pH<br />
in electrolyte solution for 1 hour or longer<br />
sensors change with time, they must be cali-<br />
and then recalibrated prior to performing<br />
brated at regular intervals using appropriate<br />
any further measurements.<br />
Soiling Treatment Info<br />
inorganic adhering substances several minutes, e.g. with HCl improved cleaning action with<br />
0.1 mol/l or NaOH 0.1 mol/l warm solutions (40–50 °C)<br />
organic substances (oil, grease, etc.) rinse off with suitable organic solvent for plastic shaft electrodes, take chemical<br />
(e.g.ethanol) or tenside solution<br />
resistance into account. Sensor can also be<br />
wiped of with a soft, moistened cloth.<br />
proteins<br />
approx. 1 hour with pepsin/HCl solution<br />
(type no. L 510)<br />
sulphides (on ceramic diaphragm) with thiourea/HCl solution cause: reaction of electrolyte with<br />
(7.5 % in HCl 0.1 mol/l) up to discoloration measuring solution.<br />
remedy: electrodes with platinum<br />
diaphragm and Ag + -free electrolyte<br />
12<br />
13
Service use recommendations<br />
for laboratory electrodes<br />
<strong>Laboratory</strong> electrodes<br />
Application/measuring medium Recommended electrodes Description Page<br />
General N 61 broad range of service use 16<br />
Stick-in measurements L 6880 refillable 16<br />
L 8880 low-maintenance 18<br />
N 5800 A refillable, micro-electrode 18<br />
N 48 A refillable robust 20<br />
N 1048 A, N 2048 A refillable, robust, integrated temperature sensor 20<br />
Media with low ion content N 61 platinum diaphragm 16<br />
N 64 ground joint diaphragm, high KCl flow rate 16<br />
Small sample quantities, small vessels N 5800 A micro-electrode, for stick-in measurement 18<br />
(e.g. ampoules, bulbs) N 5900 A micro-electrode 18<br />
N 6000 A micro-electrode, as from 0.1 ml solution 18<br />
Knick pH meter N 50 A pH combination electrode 20<br />
(Knick electrode head) N 1050 A like N 50 A, integrated temperature sensor 20<br />
Alkaline solutions, acids (strong) H 61 extreme pH values, also high temperatures 16<br />
Conductivity measurement LF 613T universal 30<br />
LF 713T organic solvents, acids (esp. H 2 SO 4 ) 30<br />
Surface measurements L 39 A refillable, plastic shaft 20<br />
Redox potentials Pt 6880 general measurements 22<br />
Waste water with high content of N 64 normal conditions 16<br />
suspended matter, suspensions H 64 also high temperatures, extreme pH values 16<br />
Titrations N 62 pH general 16<br />
N 61eis, N 6480eis pH non-aqueous, electrolyte LiCl/glacial acetic acid 16<br />
N 6480eth pH non-aqueous, electrolyte LiCl/ethanol 16<br />
AgCl 6280 Pt halogenide ions 22<br />
Pt 1200, Pt 1400 double Pt electrode for dead-stop titration 26<br />
Pt 6280, Pt 6580 redox titration general 22<br />
Pt 5901 redox titration (COD) 24<br />
Tris buffer N 6250 Calomel reference 16<br />
Low-maintenance, L 737 A plastic shaft 20<br />
for rough service use L 7137 A, L 7237 A like L 737 A, integrated temperature sensor 20<br />
Standard laboratory electrodes<br />
In addition to the BlueLine electrodes available<br />
in the new design and with their<br />
own equipment features, such as the convenient<br />
sliding plug, we also offer a complete<br />
programme of standard electrodes for<br />
practically all kinds of applications in the<br />
laboratory and in the field.<br />
On the following pages, we will be presenting<br />
to you these highly qualified sensors<br />
that have proved their reliability millions of<br />
times:<br />
◗ Even more application possibilities<br />
◗ Selection of micro-electrodes for especially<br />
small sample quantities and vessels<br />
◗ More metal electrodes for redox potential<br />
measurements and titrations<br />
◗ Sensors for additional parameters such as<br />
ammonia, sodium and oxygen<br />
◗ Individual pH glass, metal and reference<br />
electrodes for specific conditions<br />
For further applications, you will find suitable electrodes in the corresponding chapters.<br />
14<br />
15
pH combination electrodes<br />
pH combination electrodes<br />
Order no. Type no. Length Ø Dia- pH Range Reference Peculiarities<br />
with plug head<br />
L [mm] [mm] phragm glass [°C] system<br />
Shaft:<br />
glass<br />
28 510 0207 H 61 170 12 platinum H 0...+100 Silamid ®<br />
Zero point: pH = 7.0 ± 0.3<br />
28 510 0215 H 62 120 12 platinum H 0...+100 Silamid ®<br />
Electrolyte:<br />
KCl 3 mol/l<br />
28 510 0223 H 63 320 12 platinum H 0...+100 Silamid ®<br />
(except N 6250:<br />
28 510 0231 H 64 170 12 ground joint H 0...+100 Silamid ®<br />
KCl 4.2 mol/l)<br />
28 510 0248 H 65 103 1) 10 platinum H 0...+100 Silamid ® standard taper NS 14.5<br />
Membrane form:<br />
sphere<br />
28 510 0001 N 61 170 12 platinum N 0...+80 Silamid ®<br />
(see peculiarities)<br />
28 510 0034 N 62 120 12 platinum N 0...+80 Silamid ®<br />
pH range: 0...14<br />
28 510 0059 N 64 170 12 ground joint N 0...+80 Silamid ®<br />
Connection cable: e.g. L 1 A,<br />
28 510 0067 N 65 103 1) 10 platinum N 0...+80 Silamid ® standard taper NS 14.5<br />
L 1 BNC<br />
28 510 2524 H 6180 170 12 ceramic H 0...+100 Ag/AgCl<br />
L<br />
28 510 2532 H 6280 120 12 ceramic H 0...+100 Ag/AgCl<br />
28 510 2549 H 6380 320 12 ceramic H 0...+100 Ag/AgCl<br />
28 510 2565 H 6580 103 1) 10 ceramic H 0...+100 Ag/AgCl standard taper NS 14.5<br />
L<br />
28 510 1211 L 6880 120 12/8 3 x ceramic L -5...+80 Ag/AgCl spear membrane for stick-in<br />
28 510 0018 N 6180 170 12 ceramic N 0...+80 Ag/AgCl<br />
28 510 0112 N 6250 120 12 ceramic N +15...+40 Calomel for Tris buffers<br />
28 510 0042 N 6280 120 12 ceramic N 0...+80 Ag/AgCl<br />
28 510 2516 N 6580 103 1) 10 ceramic N 0...+80 Ag/AgCl standard taper NS 14.5<br />
28 510 1709 N 6980 103 1) 10 ground joint N 0...+80 Ag/AgCl standard taper NS 14.5<br />
28 509 2661 N 61eis 170 12 3 x platinum N +10...+40 Silamid ® electrolyte LiCl/glacial acetic<br />
acid L 5014<br />
28 509 2337 N 6480eis 170 12 ground joint N +10...+40 Ag/AgCl electrolyte LiCl/glacial acetic<br />
acid L 5014<br />
28 509 2329 N 6480eth 170 12 ground joint N 0...+40 Ag/AgCl electrolyte LiCl/ethanol L 5034<br />
1)<br />
length from upper end of standard taper<br />
N 62<br />
H 61<br />
H 62<br />
H 63<br />
N 61<br />
H 6180<br />
H 6280<br />
H 6380<br />
N6180<br />
N 6250<br />
N 6280<br />
N 61eis<br />
N 64<br />
H 64<br />
N 61eis<br />
N 6480 eis<br />
N 6480 eth<br />
N 65<br />
H 65<br />
H 6580<br />
N 6580<br />
L 6880 N 6980<br />
16<br />
17
pH combination electrodes<br />
Low-maintenance pH combination<br />
electrodes with plug head<br />
Order no. Type Length Dia- pH Membrane Range Electrolyte Peculiarities<br />
no. L [mm] phragm glass form [°C] [pH]<br />
Reference system: silver/silver chloride<br />
Shaft:<br />
glass, 12 mm Ø<br />
(see peculiarities)<br />
Zero point: pH = 7.0 ± 0.3<br />
Connection cable: e.g. L 1 A,<br />
L 1 BNC<br />
28 510 1252 L 7780 120 ceramic L sphere -5...+80 0...14 gel<br />
28 510 1277 L 8280 120 KPG ® L dome shaped -5...+80 2...13 Referid ®<br />
28 510 1285 L 8880 70/50 hole L spear -5...+80 2...13 Referid ® for stick-in,<br />
12/8 mm Ø<br />
L1<br />
Micro pH combination electrodes<br />
Order no. Type no. Length Ø Dia- pH Membrane Range Peculiarities<br />
with connection cable<br />
L [mm] [mm] phragm glass form [°C] [pH]<br />
Reference system:<br />
silver/silver chloride<br />
L<br />
28 510 5127 N 5800 A 96 1) 5 3 x platinum N spear 0...+80 0...14 for stick-in<br />
Shaft:<br />
glass,<br />
28 510 5579 N 5800 BNC 96 1) 5 3 x platinum N spear 0...+80 0...14 for stick-in<br />
standard taper NS 7.5<br />
Zero point: pH = 7.0 ± 0.3<br />
L<br />
28 510 5135 N 5900 A 96 1) 5 platinum N sphere 0...+80 0...14<br />
28 510 5151 N 6000 A 96 1) 3 platinum N cylinder 0...+80 0...14<br />
Electrolyte:<br />
Cable:<br />
KCl 3 mol/l<br />
1 m, with plug A<br />
L2<br />
28 510 5632 N 6000 BNC 96 1) 3 platinum N cylinder 0...+80 0...14<br />
(DIN 19 262) or with<br />
1)<br />
length from upper end of standard taper<br />
BNC plug<br />
L 7780 L 8280 L 8880 N 5900 A N 6000 A<br />
N 5800 A N 6000 BNC<br />
N 5800 BNC<br />
18<br />
19
pH combination electrodes<br />
pH combination electrodes<br />
with connection cable<br />
Order no. Type no. Length Dia- pH Membrane Range Peculiarities<br />
L [mm] phragm glass form [°C] [pH]<br />
Reference system: silver/silver chloride<br />
(see peculiarities)<br />
Shaft:<br />
glass (see peculiarities),<br />
12 mm Ø<br />
Zero point: pH = 7.0 ± 0.3<br />
Electrolyte: KCl 3 mol/l<br />
(see peculiarities)<br />
Cable:<br />
1 m, with plug A<br />
(DIN 19262) or with<br />
BNC plug<br />
L<br />
28 510 0289 L 32 A 120 fibre L sphere -5...+50 1...13 plastic shaft<br />
28 510 0297 L 32 BNC 120 fibre L sphere -5...+50 1...13 plastic shaft<br />
28 510 0318 L 39 A 120 fibre L flat -5...+50 1...13 for surfaces,<br />
plastic shaft<br />
28 510 0326 L 39 BNC 120 fibre L flat -5...+50 1...13 for surfaces,<br />
plastic shaft<br />
28 510 0437 N 42 A 120 ceramic N sphere 0...+80 0...14<br />
28 510 0445 N 48 A 120 ceramic N spear 0...+80 0...14 for stick-in<br />
28 510 1569 N 48 BNC 120 ceramic N spear 0...+80 0...14 for stick-in<br />
28 510 0453 N 50 A 108 ceramic N sphere 0...+80 0...14 for Knick pH meter<br />
28 510 0494 N 52 A 120 platinum N sphere 0...+80 0...14 Silamid ® reference<br />
28 510 5451 N 52 BNC 120 platinum N sphere 0...+80 0...14 Silamid ® reference<br />
28 510 4574 L 737 A 120 fibre L cylinder -5...+80 1...13 plastic shaft,<br />
gel electrolyte<br />
28 510 1071 L 737 BNC 120 fibre L cylinder -5...+80 1...13 plastic shaft,<br />
gel electrolyte<br />
pH combination electrodes<br />
Order no. Type no. Length Dia- pH Membrane Range plug Ø Peculiarities<br />
with temperature sensor Pt 1000 and<br />
L [mm] phragm glass form [°C] [mm]<br />
connection cable<br />
28 510 0486 N 1041 A 170 ceramic N sphere 0...+80 4<br />
Reference system: silver/silver chloride<br />
Shaft:<br />
glass (see peculiarities),<br />
12 mm Ø<br />
Zero point: pH = 7.0 ± 0.3<br />
Electrolyte: KCl 3 mol/l<br />
Cable:<br />
1 m, with plug A<br />
(DIN 19 262) or with<br />
BNC plug, also plug for<br />
temperature sensor<br />
pH range: 0...14<br />
L 32 A<br />
L 32 BNC<br />
L 39 A<br />
L 39 BNC<br />
N 48 A<br />
N 48 BNC<br />
N 1048 A<br />
N 2048 A<br />
N 1042 A<br />
N 1041 A<br />
N 1041 BNC<br />
N 1050 A<br />
N 2041 A<br />
N 2041 BNC<br />
N 2042 A<br />
N 1042 BNC<br />
N 42 A<br />
N 50 A<br />
N 52 A<br />
N 52 BNC<br />
L 7137 A<br />
L 7237 A<br />
L 7237 BNC<br />
L 737 A<br />
L 737 BNC<br />
28 510 0531 N 1041 BNC 170 ceramic N sphere 0...+80 4<br />
28 510 4541 N 1042 A 120 ceramic N sphere 0...+80 4<br />
28 510 5476 N 1042 BNC 120 ceramic N sphere 0...+80 4<br />
28 510 4611 N 1048 A 120 ceramic N spear 0...+80 4 for stick-in<br />
28 510 0375 N 1050 A 108 ceramic N sphere 0...+80 4 for Knick pH meter<br />
28 510 0342 N 2041 A 170 ceramic N sphere 0...+80 2<br />
28 510 0334 N 2041 BNC 170 ceramic N sphere 0...+80 2<br />
28 510 0359 N 2042 A 120 ceramic N sphere 0...+80 2<br />
28 510 4628 N 2048 A 120 ceramic N spear 0...+80 2 for stick-in<br />
28 510 4582 L 7137 A 120 fibre L cylinder -5...+80 4 gel electrolyte,<br />
plastic shaft<br />
28 510 4599 L 7237 A 120 fibre L cylinder -5...+80 2 gel electrolyte,<br />
plastic shaft<br />
28 510 1174 L 7237 BNC 120 fibre L cylinder -5...+80 2 gel electrolyte,<br />
plastic shaft<br />
20<br />
21
Metal combination electrodes<br />
Metal combination electrodes<br />
with plug head<br />
Order no. Type no. Length Dia- Sensor Sensor Range Peculiarities<br />
L [mm] phragm metal form [°C]<br />
Reference system: silver/silver chloride<br />
(see peculiarities)<br />
Shaft:<br />
glass, 12 mm Ø<br />
(see peculiarities)<br />
Electrolyte: KCl 3 mol/l<br />
(see peculiarities)<br />
Connection cable: e.g. L 1 A,<br />
L 1 BNC<br />
28 510 2208 Ag 6180 170 ceramic Ag cap, 4 mm Ø -5...+100 electrolyte L 2114<br />
28 510 2343 Ag 6280 120 ceramic Ag cap, 4 mm Ø -5...+100 electrolyte L 2114<br />
28 510 2216 Ag 6580 103 1) ceramic Ag cap, 4 mm Ø -5...+100 electrolyte L 2114, standard taper<br />
NS 14.5, shaft 10 mm Ø<br />
28 510 2351 AgCl 6280 120 ceramic Ag cap, 4 mm Ø -5...+100 electrolyte L 2114,<br />
sensor with AgCl coated<br />
28 510 2413 AgCl 6280 Pt 120 platinum Ag cap, 4 mm Ø -5...+100 electrolyte L 2114,<br />
sensor with AgCl coated<br />
28 510 2121 Au 6280 120 ceramic Au pin, 2 mm Ø -5...+100<br />
28 510 2002 Pt 6 170platinum Ptpin, 1 mm Ø+10...+4<br />
L<br />
28 510 2019 Pt 62120platinum Ptpin, 1 mm Ø+10...+4<br />
28 510 2232 Pt 6180 170 ceramic Pt pin, 1 mm Ø -5...+100<br />
28 510 2249 Pt 6280 120 ceramic Pt pin, 1 mm Ø -5...+100<br />
28 510 2257 Pt 6580 103 1) ceramic Pt pin, 1 mm Ø -5...+100 standard taper NS 14.5,<br />
shaft 10 mm Ø<br />
28 510 0075 Pt 6880 120 ceramic Pt ring, 6 mm Ø -5...+100<br />
28 510 2265 Pt 6980 170 ceramic Pt ring, 6 mm Ø -5...+100<br />
28 510 2281 Pt 8280 120 KPG ® Pt disk, 6 mm Ø -5...+100 electrolyte Referid ®<br />
1)<br />
length from upper end of standard taper<br />
AgCl 6280<br />
Ag 6180<br />
Ag 6280<br />
AgCl 6280 Pt<br />
Au 6280<br />
Pt 6180<br />
Pt 61<br />
Pt 62<br />
Pt 6280<br />
Pt 6580<br />
Pt 6880<br />
Pt 6980<br />
Pt 8280<br />
22<br />
23
Metal combination electrodes<br />
Metal combination electrodes<br />
with connection cable<br />
Order no. Type no. Length Dia- Sensor Sensor Range Peculiarities<br />
L [mm] phragm metal form [°C]<br />
Reference system:<br />
Shaft:<br />
Electrolyte:<br />
Cable:<br />
silver/silver chloride<br />
glass<br />
(see peculiarities),<br />
12 mm Ø<br />
KCl 3 mol/l<br />
(see peculiarities)<br />
1 m, with plug A<br />
(DIN 19 262) or<br />
BNC plug<br />
28 510 2051 Ag 42 A 120 ceramic Ag cap, 4 mm Ø -5...+100 electrolyte L 2114<br />
28 510 2302 Pt 42 A 120 ceramic Pt pin, 1 mm Ø -5...+100<br />
28 510 2224 Pt 48 A 120 ceramic Pt ring, 6 mm Ø -5...+100<br />
28 510 2195 Pt 48 BNC 120 ceramic Pt ring, 6 mm Ø -5...+100<br />
28 510 0153 Pt 737 A 120 fibre Pt pin, 1 mm Ø -5...+80 plastic shaft, gel electrolyte<br />
Micro metal combination electrodes<br />
L<br />
L<br />
Order no. Type no. Length L/ Dia- Sensor Sensor Temp. Peculiarities<br />
ø [mm] phragm metal form [°C]<br />
Reference system:<br />
silver/silver chloride<br />
Shaft:<br />
glass<br />
28 510 5168 Pt 5700 A 120/6 platinum Pt pin, 1 mm Ø -5...+100 1 m connection cable<br />
Electrolyte:<br />
KCl 3 mol/l<br />
with DIN plug<br />
28 510 5192 Pt 5900 A 96 1) /5 platinum Pt pin, 1 mm Ø -5...+100 NS 7.5; 1 m connection cable<br />
with DIN plug<br />
28 510 5702 Pt 5900 BNC 96 1) /5 platinum Pt pin, 1 mm Ø -5...+100 NS 7.5; 1 m connection cable<br />
with BNC plug<br />
28 510 5065 Pt 5901 160 1) /5 platinum Pt pin, 1 mm Ø -5...+100 NS 7.5; plug head<br />
1)<br />
length from upper end of standard taper<br />
Ag 42 A<br />
Pt 42 A<br />
Pt 737 A<br />
Pt 48 A<br />
Pt 48 BNC<br />
Pt 5900 A<br />
Pt 5700 A<br />
Pt 5900 BNC<br />
Pt 5901<br />
24<br />
25
Single electrodes<br />
pH glass electrode with plug head<br />
Reference system: silver/silver chloride<br />
Shaft:<br />
glass, 12 mm Ø<br />
Zero point: pH = 7.0 ± 0.3<br />
Membrane form: sphere<br />
Connection cable: e.g. L 1 A<br />
L 1 BNC<br />
Order no. Type no. Length pH Range Peculiarities<br />
L [mm] glass [pH] [°C]<br />
28 510 3212 H 1180 120 H 0...14 0...+100<br />
Metal electrodes with plug head<br />
Shaft:<br />
glass, 12 mm Ø<br />
(see peculiarities)<br />
Connection cable: e.g. L 1 A<br />
L 1 BNC<br />
(see peculiarities)<br />
L<br />
Order no. Type no. Length Sensor Sensor Range Peculiarities<br />
L [mm] metal form [°C]<br />
28 510 3607 Ag 1100 120 Ag cap, 4 mm Ø -5...+100<br />
28 510 3512 Pt 1200 120 Pt 2 pins, 1 mm Ø -30...+135 double platinum electrode,<br />
cable e.g. L 1 NN<br />
28 510 3537 Pt 1400 103 1) Pt 2 pins, 1 mm Ø -30...+135 double platinum electrode,<br />
shaft 10 mm Ø,<br />
standard taper NS 14.5,<br />
cable e.g. L 1 NN<br />
28 510 3553 Pt 1800 120 Pt ring, 6 mm Ø -30...+135<br />
1)<br />
length from upper end of standard taper<br />
H 1180<br />
Ag 1100<br />
Pt 1200<br />
Pt 1400<br />
Pt 1800<br />
26<br />
27
Single electrodes<br />
Reference electrodes with plug head<br />
Order no. Type no. Length Ø Range Dia- Reference Peculiarities<br />
L [mm] [mm] [°C] phragm system<br />
Shaft:<br />
glass<br />
Electrolyte for<br />
28 510 4003 B 2220 120 12 -5...+100 ceramic Ag/AgCl double electrolyte system<br />
reference system:<br />
Ag/AgCl: KCl 3 mol/l,<br />
28 510 3997 B 2420 120 12 -5...+100 ground joint Ag/AgCl<br />
e.g. L 300<br />
28 510 4011 B 2810 120 12 +15...+40 ceramic calomel<br />
calomel:<br />
KCl 4.2 mol/l,<br />
28 510 4028 B 2820 120 12 -5...+100 ceramic Ag/AgCl<br />
e.g. L 420<br />
28 510 4044 B 2910 120 12 +15...+40 platinum calomel<br />
Hg/Hg 2 SO 4 :<br />
K 2 SO 4 0.6 mol/l,<br />
28 510 4052 B 2920 120 12 -5...+100 platinum Ag/AgCl<br />
e.g. L 1254<br />
28 510 4077 B 3410 103 1) 10 +15...+40 ceramic calomel standard taper NS 14.5<br />
pH range: 0...14<br />
28 510 4085 B 3420 103 1) 10 -5...+100 ceramic Ag/AgCl standard taper NS 14.5<br />
Connection cable:<br />
e.g. B 1 N<br />
28 510 4106 B 3510 103 1) 10 +15...+40 platinum calomel standard taper NS 14.5<br />
28 510 4114 B 3520 103 1) 10 -5...+100 platinum Ag/AgCl standard taper NS 14.5<br />
28 510 0091 B 3610 103 1) 10 +15...+40 ceramic Hg/Hg 2 SO 4 standard taper NS 14.5<br />
28 510 4163 B 3920 103 1) 10 -5...+100 ground joint Ag/AgCl double electrolyte system,<br />
L<br />
standard taper NS 14.5<br />
L<br />
1)<br />
length from upper end of standard taper<br />
B 2220<br />
B 2420<br />
B 2820<br />
B 2810<br />
B 2910<br />
B 2920<br />
B 3420<br />
B 3410<br />
B 3510<br />
B 3520<br />
B 3610<br />
B 3920<br />
28<br />
29
Conductivity cells<br />
Conductivity cells with plug head<br />
Shaft:<br />
glass<br />
(see peculiarities),<br />
12 mm Ø<br />
Connection cable: e.g. 9919/21<br />
(without temp. sensor)<br />
or 9919/41<br />
(with temp. sensor)<br />
(for CG 853(P))<br />
Order no. Type no. Length Sensor Constant Range Range 1) Peculiarities<br />
L [mm] (±10%) [cm- 1 ] [°C] [µS/cm]...[mS/cm]<br />
28 510 4809 LF 1050 120 2 Pt plates 0.5 -30...+135 0...100<br />
28 510 4817 LF 1100 120 2 Pt plates 1.0 -30...+135 0...200<br />
28 510 5813 LF 1100T 120 2 Pt plates 1.0 -30...+135 0...200 temp. sensor Pt 1000<br />
28 510 4825 LF 1200 120 2 Pt plates 2.0 -30...+135 0...400<br />
28 510 4866 LF 4100 – 2 Pt plates 1.0 -30...+135 0...200 flow-through cell<br />
28 510 4944 LF 5100 120 2 Pt rings 1.0 -5...+80 0...200 plastic shaft<br />
28 510 4952 LF 5100T 120 2 Pt rings 1.0 -5...+80 0...200 plastic shaft,<br />
temp. sensor Pt 1000<br />
Conductivity cells with 1 m<br />
connection cable and 8-pole plug<br />
L<br />
Order no. Type no. Length Sensor Constant Range Range 1) Peculiarities<br />
L [mm] (±10%) [cm -1 ] [°C] [µS/cm]...[mS/cm]<br />
Shaft:<br />
Temperature<br />
sensor:<br />
12 mm Ø<br />
NTC 30 KΩ<br />
28 510 6037 LF 513T 120 2 Pt rings 1.0 -5...+80 0...200 plastic shaft<br />
28 510 6131 LF 613T 120 4 Pt rings 1.0 -5...+80 0...2000 plastic shaft<br />
28 510 6189 LF 713T 120 4 Pt rings 1.0 -30...+135 0...2000 glass shaft<br />
1)<br />
Out of the recommended conductivity range the error of measurement can be >10 %.<br />
LF 1100T<br />
LF 1050<br />
LF 1100<br />
LF 1200<br />
LF 4100<br />
LF 5100<br />
LF 5100T<br />
LF 513T<br />
LF 613T<br />
LF 713T<br />
30<br />
31
Further sensors<br />
Ammonia combination electrode<br />
with plug head<br />
Order no. Type no. Length Range Range Peculiarities<br />
L [mm] [°C] [mg/l]<br />
Shaft:<br />
Connection cable:<br />
plastic, 12 mm Ø<br />
e.g. L 1 A<br />
L 1 BNC<br />
28 510 2808 NH 1100 120 0...+50 0.1...1000 membrane module<br />
interchangeable<br />
Sodium combination electrode<br />
with plug head<br />
Order no. Type no. Length Dia- Membrane Range Range Peculiarities<br />
L [mm] phragm glass [°C] [pNa]<br />
Reference system: Silamid ®<br />
Shaft:<br />
glass, 12 mm Ø<br />
Zero point: pNa = 2.0<br />
Membrane form: sphere<br />
Connection cable: e.g. L 1 A<br />
L 1 BNC<br />
L<br />
28 510 0026 Na 61 170 platinum Na +10...+80 0...6<br />
Oxygen electrodes<br />
Shaft:<br />
plastic (POM)<br />
Order no. Type no. Length Range Range Peculiarities<br />
L [mm] [°C] [mg/l]<br />
28 510 4603 OX 1100 120 0...+45 0...60 galvanic sensor, Pt cathode, Ag anode, 4-pole<br />
plug head, temperature compensated (NTC 100kΩ),<br />
shaft 12 mm Ø, meas. current at saturation about<br />
100 nA, min. approach velocity 10 cm/s,<br />
connection cable e.g. 9910/21 (for CG 867)<br />
28 511 1664 9009/61 145 0...+50 0...50 amperometric sensor, Au cathode, Pb anode,<br />
fixed cable 1.5 m with 8-pole plug ,<br />
IMT temperature compensated, shaft 15.25 mm Ø,<br />
membrane FEP, 13 µm thick, accuracy 1%<br />
at 18 cm/s approach velocity<br />
NH 1100 Na 61<br />
OX 1100 9009/61<br />
32<br />
33
Resistance thermometers<br />
Resistance thermometers<br />
with plug head<br />
Order no. Type no. Length Ø Sensor Range Shaft Connection<br />
L [mm] [mm] [°C] cable e.g.<br />
28 510 4509 W 2030 120 12 Pt 100 -30...+135 glass 9907/21<br />
28 510 4496 W 2130 120 12 Pt 1000 -30...+135 glass 9907/21<br />
Resistance thermometers<br />
with 1 m connection cable<br />
Order no. Type no. Length Ø Sensor Range Shaft Connection<br />
L [mm] [mm] [°C] plug<br />
28 510 5221 W 5780 NN 120 6 Pt 1000 -30...+135 glass 2 x, 4 mm Ø<br />
28 510 5254 W 5790 NN 120 4 Pt 1000 -30...+135 stainless steel 2 x, 4 mm Ø<br />
28 510 5776 W 5790 PP 120 4 Pt 1000 -30...+135 stainless steel 2 x, 2 mm Ø<br />
L<br />
28 510 5262 W 5791 NN 170 4 Pt 1000 -30...+135 stainless steel 2 x, 4 mm Ø<br />
28 510 5287 W 5980 NN 96 1) 5, NS 7.5 Pt 1000 -30...+135 glass 2 x, 4 mm Ø<br />
L<br />
1)<br />
length from upper end of standard taper<br />
W 2130<br />
W 2030<br />
W 5780 NN<br />
W 5791 NN<br />
W 5790 NN<br />
W 5790 PP<br />
W 5980 NN<br />
34<br />
35
Accessories<br />
Connection cable<br />
Electrode plug head Electrode socket Instrument plug variation for measurement units<br />
pH-/redox-/ammonia-/ A (DIN, Germany) BNC (Europe, Oversea)<br />
sodium combination<br />
electrodes as well as pH-/<br />
redox single electrodes<br />
socket L EE (Radiometer) R (Metrohm)<br />
(sockets L, LB, K are S (UK socket without extension) NN (double platinum elec.)<br />
mutually compatible)<br />
more variation, no illust.:<br />
D (USA, single electrodes)<br />
DP (USA, combination elec.)<br />
H (Seibold, Lemo plug)<br />
MN (F, combination elec.)<br />
X (without instr. plug, free end)<br />
Reference electrodes B N P<br />
X (free end, no illustr.)<br />
SMEK socket LS A NN BNC NN<br />
Resistance thermometers, plug 9907 NN (older instruments) 8-pole (only for CG 853 (P))<br />
conductivity cells without<br />
temperature sensor<br />
Conductivity cells with socket 9909 9910 8-pole (only for CG 853 (P))<br />
temperature sensor as well<br />
as oxygen electrodes<br />
X (free end, no illustr.)<br />
Connection cable with plugs, mounted<br />
Order no. Type no. Description<br />
28 512 2904 A 1 A DIN instrument plug (A), 1 m coax. cable, DIN instrument plug (A)<br />
28 512 3793 A 1 BNC DIN instrument plug (A), 1 m coax. cable, BNC instrument plug (BNC)<br />
28 512 1916 B 1 N reference electrodes plug (B), 1 m single core cable, 4 mm banana plug (N)<br />
28 512 2012 B 1 P reference electrodes plug (B), 1 m single core cable, 2 mm pin plug (P)<br />
28 512 1813 B 1 X reference electrodes plug (B), 1 m single core cable, free end<br />
28 512 0217 K 1 A electrode plug (K), 1 m coax. cable, DIN instrument plug (A)<br />
28 512 1213 K 1 BNC electrode plug (K), 1 m coax. cable, BNC instrument plug (BNC)<br />
28 512 1119 K 1 H electrode plug (K), 1 m coax. cable, Lemo/Seibold instrument plug (H)<br />
28 512 1419 K 1 MN electrode plug (K), 1 m coax. cable, France instrument plug + 4 mm banana plug (MN)<br />
28 512 1513 K 1 NN electrode plug (K), 1 m coax. cable, 2 x 4 mm banana plug (NN)<br />
28 512 1616 K 1 S electrode plug (K), 1 m coax. cable, plug (S), as extension cable<br />
28 512 4716 9907/21 electrode plug (9907/00), 1 m two core cable, 2 x 4-mm-plug for conductivity cells (NN)<br />
28 512 5618 9909/31 electrode plug (9907/00), 1 m two core cable, 2 x 4-mm banana plug (NN),<br />
for platinizing of 2-pole conductivity cells with temperature sensor<br />
28 512 5515 9910/11 electrode plug (9909/00), 1 m four core cable up to 80°C, electrode plug (9910/00),<br />
for resistance therm., for 2-pole cond. cells with temperature sensor or as extension<br />
28 512 5215 9910/21 electrode plug (9909/00), 1 m four core cable shielded, electrode plug (9910/00),<br />
for oxygen electrode OX 1100 on CG 867 or as extension cable<br />
28 512 5523 9919/21 electrode plug (9907/00), 1 m two core cable, 8-pole instrument plug,<br />
for 2-pole cond. cells without temperature sensor on conductivity meter CG 853 (P)<br />
28 512 5548 9919/41 electrode plug (9909/00), 1 m four core cable, 8-pole instrument plug,<br />
for 2-pole cond. cells with temperature sensor an conductivity meter CG 853 (P)<br />
Connection cable with plugs, injection moulded<br />
Order no. Type no. Description<br />
28 512 2456 L 1 A electrode plug (L), 1 m coax. cable, DIN instrument plug (A)<br />
28 512 2497 L 1 BNC electrode plug (L), 1 m coax. cable, BNC instrument plug (BNC)<br />
28 512 2559 L 1 D electrode plug (L), 1 m coax. cable, USA instrument plug (D)<br />
28 512 2604 L 1 DP electrode plug (L), 1 m coax. cable, USA instrument plug and 2 mm pin plug (DP)<br />
28 512 2501 L 1 EE electrode plug (L), 1 m coax. cable, Radiometer instrument plug (EE)<br />
28 512 2534 L 1 R electrode plug (L), 1 m coax. cable, Metrohm instrument plug (R)<br />
28 512 2407 L 1 X electrode plug (L), 1 m coax. cable, free ends<br />
28 512 2653 LB 1 A electrode plug (for BlueLine), 1 m coax. cable, DIN instrument plug (A)<br />
28 512 2661 LB 1 BNC electrode plug (for BlueLine), 1 m coax. cable, BNC instrument plug (BNC)<br />
28 512 2678 LB 3 A electrode plug (for BlueLine), 3 m coax. cable, DIN instrument plug (A)<br />
28 512 2707 LS 1 ANN electrode plug (for SMEK plug head), 1 m cable KA 19, DIN instrument plug and 2 x 4 mm banana plug<br />
28 512 2715 LS 3 ANN like LS 1 ANN, but 3 m cable<br />
28 512 2723 LS 1 BNCNN electrode plug (for SMEK plug head), 1 m cable KA 19, BNC instrument plug and 2 x 4 mm banana plug<br />
28 512 2731 LS 3 BNCNN like LS 1 BNCNN, but 3 m cable<br />
36<br />
37
Solutions<br />
Standard buffer solutions according to DIN 19 266<br />
sterilized for longer storability, without preservation<br />
Technical buffer solutions according to DIN 19 267<br />
sterilized for longer storability, without preservation<br />
Order no. Type no. pH value at 25 °C Content<br />
Order no. Type no. pH value at 25 °C Content<br />
28 513 7977 L 4791 1.68 60 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8246 L 4794 4.01 60 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8254 L 4796 6.87 60 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8262 L 4799 9.18 60 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8402 L 4790 4.01/6.87 2 x 30 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 7985 L 4797 1.68/6.87/9.18 3 x 20 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8238 L 4798 4.01/6.87/9.18 3 x 20 FIOLAX ® ampoules à 25 ml, with manufacturer certificate<br />
28 513 8279 L 4893/Set 4.01/6.87 2 x 9 FIOLAX ® ampoules à 25 ml, with manufacturer certificate,<br />
with electrolyte solution L 3008<br />
28 513 7841 L 168 1.68 1000 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 7677 L 1684 1.68 250 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8098 L 401 4.01 1000 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8008 L 4014 4.01 250 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8102 L 687 6.87 1000 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8016 L 6874 6.87 250 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8119 L 918 9.18 1000 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8024 L 9184 9.18 250 ml in DURAN ® glass bottle, with manufacturer certificate<br />
28 513 8213 L 4694 4.00 60 FIOLAX ® ampoules à 25 ml<br />
28 513 8221 L 4697 7.00 60 FIOLAX ® ampoules à 25 ml<br />
28 513 8205 L 4691 10.00 60 FIOLAX ® ampoules à 25 ml<br />
28 513 8398 L 4690 4.00/7.00 2 x 30 FIOLAX ® ampoules à 25 ml<br />
28 513 8192 L 4698 4.00/7.00/10.00 3 x 20 FIOLAX ® ampoules à 25 ml<br />
28 513 8632 L 4895/Set 4.00/7.00 2 x 9 FIOLAX ® ampoules à 25 ml,<br />
with electrolyte solution L 3008<br />
28 513 8727 L 400 4.00 1000 ml in DURAN ® glass bottle<br />
28 513 8032 L 4004 4.00 250 ml in DURAN ® glass bottle<br />
28 513 8735 L 700 7.00 1000 ml in DURAN ® glass bottle<br />
28 513 8049 L 7004 7.00 250 ml in DURAN ® glass bottle<br />
28 513 8719 L 100 10.00 1000 ml in DURAN ® glass bottle<br />
28 513 8057 L 1004 10.00 250 ml in DURAN ® glass bottle<br />
38<br />
39
Solutions<br />
Colored technical buffer solutions in plastic bottles<br />
Order no. Type no. pH value at 25 °C Content<br />
28 513 9148 LC 4002 K 4.00 500 ml in PE bottle, yellow<br />
28 513 9172 LC 7002 K 7.00 500 ml in PE bottle, green<br />
28 513 9201 LC 1002 K 10.00 500 ml in PE bottle, blue<br />
Technical buffer solutions according to DIN 19 267 in canisters<br />
for longer storability preserved with thymol<br />
Order no. Type no. pH value at 25 °C Content<br />
28 513 8673 L 4655 4.65 5 L in plastic canister<br />
28 513 8681 L 6795 6.79 5 L in plastic canister<br />
Electrolyte solutions, aqueous<br />
for reference electrodes and electrolyte bridges<br />
Order no. Type no. Description Content<br />
28 513 6956 L 101 potassium chloride solution 1 mol/l 1000 ml in DURAN ® glass bottle, sterilized<br />
28 513 8649 L 1254 potassium sulfate solution 0.6 mol/l 250 ml in DURAN ® glass bottle<br />
28 513 8151 L 200 low-temperature electrolyte (-30 °C) 1000 ml in DURAN ® glass bottle<br />
28 513 8365 L 2004 low-temperature electrolyte (-30 °C) 250 ml in DURAN ® glass bottle<br />
28 513 8349 L 2114 2 mol/l KNO 3 + 0.001 mol/l KCl for Ag combination electrodes 250 ml in DURAN ® glass bottle<br />
28 513 6923 L 2214 2 mol/l KNO 3 + 0.001 mol/l KCl für Ag comb. electr., thickened 250 ml in DURAN ® glass bottle<br />
28 513 8332 L 2224 potassium chloride solution 2 mol/l 250 ml in DURAN ® glass bottle<br />
28 513 9029 L 2604 low-temperature electrolyte (-60 °C) 250 ml in DURAN ® glass bottle<br />
28 513 8554 L 300 potassium chloride solution 3 mol/l 1000 ml in DURAN ® glass bottle, sterilized<br />
28 513 8427 L 3004 potassium chloride solution 3 mol/l 250 ml in DURAN ® glass bottle, sterilized<br />
28 513 8505 L 3008 potassium chloride solution 3 mol/l 50 ml in PE bottle<br />
28 513 9004 L 301 potassium chloride solution 3 mol/l, Ag/AgCl saturated 1000 ml in DURAN ® glass bottle<br />
28 513 8419 L 3014 potassium chloride solution 3 mol/l, Ag/AgCl saturated 250 ml in DURAN ® glass bottle<br />
28 513 8468 L 310 potassium chloride solution 2 mol/l, gel for sterilisable electrodes 1000 ml in DURAN ® glass bottle<br />
28 513 8484 L 3104 potassium chloride solution 2 mol/l, gel for sterilisable electrodes 250 ml in DURAN ® glass bottle<br />
28 513 8702 L 320 K potassium chloride solution 2 mol/l, gel for Ag 2 S electrodes 1000 ml in DURAN ® glass bottle<br />
28 513 8143 L 350 potassium chloride solution 3.5 mol/l 1000 ml in DURAN ® glass bottle, sterilized<br />
28 513 8127 L 3504 potassium chloride solution 3.5 mol/l 250 ml in DURAN ® glass bottle, sterilized<br />
28 513 8587 L 420 potassium chloride solution 4.2 mol/l 1000 ml in DURAN ® glass bottle<br />
28 513 8608 L 4204 potassium chloride solution 4.2 mol/l 250 ml in DURAN ® glass bottle<br />
40<br />
41
Solutions<br />
Electrolyte solutions, organic<br />
for measurements in organic solutions: for reference electrodes and electrolyte bridges<br />
Order no. Type no. Description Content<br />
28 513 8324 L 5014LiCl in glacial acetic acid250 ml in DURAN ® glass bottle<br />
28 513 8316 L 5024LiCl in methanol250 ml in DURAN ® glass bottle<br />
28 513 8308 L 5034LiCl in ethanol250 ml in DURAN ® glass bottle<br />
28 513 9012 L 4804 for tensides containing solutions 250 ml in DURAN ® glass bottle<br />
Solutions for oxygen measurements<br />
Solutions and accessories for conductivity measurements<br />
Order no. Type no. Description Content<br />
28 513 8616LF 906platinizing solution 1 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6503LF 990test solution KCl 0.001 mol/l (147 µS/cm)3 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6511LF 991test solution KCl 0.01 mol/l (1.41 mS/cm)3 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6528LF 992test solution KCl 0.1 mol/l (12.9 mS/cm)3 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6293LF 995test solution KCl 0.01/0.1/1 mol/l (1.41/12.9/112 mS/cm)3 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6174LF 999/Se test solution KCl 0.01/0.1 mol/l (1.41/12.9 mS/cm)3 x 6 FIOLAX ® ampoules à 20 ml<br />
and LF 9063 x 6 FIOLAX ® ampoules à 20 ml<br />
28 512 6166LF 1000/Setlike LF 999/Set, additionally platinizing vessel and cable B 1 N 3 x 6 FIOLAX ® ampoules à 20 ml<br />
Order no. Type no. Description Content<br />
Redox test solutions<br />
28 513 8513 L 6708 electrolyte for oxygen electrodes OX 1100/OX 1101 50 ml in PE bottle<br />
28 512 6606 OX 920 electrolyte for oxygen electrodes 9009/61 50 ml in PE bottle<br />
28 512 6614 OX 921 cleaning solution for oxygen electrodes 9009/61 50 ml in PE bottle<br />
28 513 8287 OX 060 zero point solution for oxygen electrodes OX 1100/1101 60 FIOLAX ® ampoules à 25 ml<br />
28 513 6964 L 6218 cleaning solution citric acid 1 mol/l 50 ml in PE bottle<br />
Solution for ammonia measurements<br />
Order no. Type no. Description Content<br />
28 513 7344 L 6408 electrolyte for ammonia electrodes 50 ml in PE bottle<br />
Order no. Type no. Redox voltage Content<br />
Pt/calomel Pt/Ag/AgCl<br />
(KCl sat.)<br />
(KCl 3 mol/l)<br />
28 513 8373L 4619180 mV220 mV60 FIOLAX ® ampoules à 20 ml,<br />
according to DIN 38 404-C6<br />
28 513 8357L 4643430 mV470 mV60 FIOLAX ® ampoules à 20 ml<br />
28 513 8381L 4660600 mV640 mV60 FIOLAX ® ampoules à 20 ml<br />
28 513 8784L 4648180, 430, 600 mV 220, 470, 640 mV3 x 20 FIOLAX ® ampoules à 20 ml<br />
28 513 8184 L 430 430 mV 470 mV 1000 ml in DURAN ® glass bottle<br />
28 513 8168 L 4304 430 mV 470 mV 250 ml in DURAN ® glass bottle<br />
Cleaning solutions for combination electrodes and reference electrodes<br />
Order no. Type no. Description Content<br />
28 513 8538 L 510 Pepsin/hydrochloric acid solution 1000 ml in DURAN ® glass bottle<br />
28 513 8295 L 5104 Pepsin/hydrochloric acid solution 250 ml in DURAN ® glass bottle<br />
42<br />
43
Electrolyte bridges,<br />
further accessories<br />
Electrolyte bridges<br />
Shaft:<br />
glass, 12 mm Ø<br />
Order no. Type no. Length Diaphragm Peculiarities<br />
L [mm]<br />
28 510 4209 B 511 103 1) ceramic tapper NS 14.5 and NS 14.5 for electrodes to build in<br />
28 510 4217 B 521 120 ceramic plastic sleeve and NS 14.5 for electrodes to build in<br />
28 510 4225 B 522 120 Pt, at side plastic sleeve and NS 14.5 for electrodes to build in<br />
28 510 4233 B 524 120 ground joint plastic sleeve and NS 14.5 for electrodes to build in<br />
Further accessories<br />
Order no. Type no. Description<br />
L<br />
B 511 Z 451<br />
Z 461<br />
Z 462<br />
28 512 3806 BXX plug for reference electrodes, single pole<br />
28 512 3571 EE plug for Radiometer instruments<br />
28 512 3703 KXX coaxial plug for combination electrodes and indicator electrodes<br />
28 512 3728 SXX coaxial plug for extension cable and for socket UK<br />
28 512 3206 Z 505 seal cap with inside thread for electrode plug head<br />
28 512 3214 Z 506 seal cap with outside thread for KXX and BXX plugs<br />
28 512 9509 Z 512 seal cap with inside thread for BlueLine electrodes<br />
28 512 6482 NH 928 electrolyte for ammonia electrodes in 50 ml plastic bottle, 3 membrane modules<br />
28 512 6499 NH 995 membrane module set: 3 membrane modules, 3 caps<br />
28 512 6639 OX 923 3 spare membrane heads for oxygen electrodes 9009/61<br />
28 512 6655 OX 925 maintenance set (OX 920, OX 921, OX 923, and SF 300) for oxygen electrodes 9009/61<br />
28 512 6277 OX 929 5 spare membrane heads for oxygen electrodes OX 1100/OX 1101<br />
28 512 6647 OxiCal ® SL calibration vessel for oxygen electrodes 9009/61<br />
28 512 6622 SF 300 grinding foil for oxygen electrodes 9009/61<br />
28 521 5229 TZ 1520 tapper adapter NS 14.5, PTFE, for electrodes with 12 mm Ø shaft<br />
28 512 3103 Z 341 stainless steel clamp for NS 7.5/16<br />
28 512 3111 Z 342 stainless steel clamp for NS 14.5/23<br />
28 512 3255 Z 371 adapter NS 7.5/12<br />
28 512 3136 Z 451 measuring and storing vessel with sleeve NS 7.5/16<br />
28 512 3152 Z 461 measuring and storing vessel with sleeve NS 14.5/23<br />
28 512 3169 Z 462 flow through measuring vessel with sleeve NS 14.5/23<br />
28 512 3185 Z 472 watering cap for electrodes with 12 mm Ø shaft<br />
28 512 2961 Z 50 electrode adapter for Knick<br />
28 512 3193 Z 501 O-ring seal 10.5/1.5 for electrode plug head<br />
1)<br />
Length from upper end of standard taper<br />
Subject to technical changes.<br />
Schott BlueLine, Silamid, Referid, KPG, Fiolax, Duran are registered trademarks of the SCHOTT Group, Mainz, Germany.<br />
44<br />
45
Index electrodes<br />
Index accessories<br />
Type no.<br />
Order no. Page<br />
Type no.<br />
Order no. Page<br />
Type no.<br />
Order no. Page<br />
Type no. Order no. Page<br />
Type no. Order no. Page<br />
Type no. Order no. Page<br />
Type no.<br />
Order no. Page<br />
Type no. Order no. Page<br />
Ag 1100 28 510 3607 26<br />
N 1041 BNC 28 510 0531 20<br />
Pt 1800 28 510 3553 26<br />
A 1 A 28 512 2904 37<br />
L 300 28 513 8554 41<br />
L 4895/Set 28 513 8632 39<br />
OX 921 28 512 6614 42<br />
Ag 42 A 28 510 2051 24<br />
N 1042 A 28 510 4541 20<br />
Pt 42 A 28 510 2302 24<br />
A 1 BNC 28 512 3793 37<br />
L 3004 28 513 8427 41<br />
L 5014 28 513 8324 42<br />
OX 923 28 512 6639 45<br />
Ag 6180 28 510 2208 22<br />
BlueLine48LF 28 512 9488 10<br />
N 1042 BNC 28 510 5476 20<br />
Pt 48 A 28 510 2224 24<br />
B 1 N 28 512 1916 37<br />
L 3008 28 513 8505 41<br />
L 5024 28 513 8316 42<br />
OX 925 28 512 6655 45<br />
Ag 6280 28 510 2343 22<br />
H 1180 28 510 3212 26<br />
N 1048 A 28 510 4611 20<br />
Pt 48 BNC 28 510 2195 24<br />
B 1 P 28 512 2012 37<br />
L 301 28 513 9004 41<br />
L 5034 28 513 8308 42<br />
OX 929 28 512 6277 45<br />
Ag 6580 28 510 2216 22<br />
H 61 28 510 0207 16<br />
N 1050 A 28 510 0375 20<br />
PT 5700 A 28 510 5168 24<br />
B 1X 28 512 1813 37<br />
L 3014 28 513 8419 41<br />
L 510 28 513 8538 43<br />
OxiCal ® SL 28 512 6647 45<br />
AgCl 6280 28 510 2351 22<br />
H 6180 28 510 2524 16<br />
N 2041 A 28 510 0342 20<br />
Pt 5900 A 28 510 5192 24<br />
B 511 28 510 4209 45<br />
L 310 28 513 8468 41<br />
L 5104 28 513 8295 43<br />
SF 300 28 512 6622 45<br />
AgCl 6280 Pt 28 510 2413 22<br />
H 62 28 510 0215 16<br />
N 2041 BNC 28 510 0334 20<br />
Pt 5900 BNC 28 510 5702 24<br />
B 521 28 510 4217 45<br />
L 3104 28 513 8484 41<br />
L 6218 28 513 6964 42<br />
SXX 28 512 3728 45<br />
Au 6280 28 510 2121 22<br />
H 6280 28 510 2532 16<br />
N 2042 A 28 510 0359 20<br />
Pt 5901 28 510 5065 24<br />
B 522 28 510 4225 45<br />
L 320 K 28 513 8702 41<br />
L 6408 28 513 7344 42<br />
TZ 1520 28 521 5229 45<br />
B 2220 28 510 4003 28<br />
H 63 28 510 0223 16<br />
N 2048 A 28 510 4628 20<br />
Pt 61 28 510 2002 22<br />
B 524 28 510 4233 45<br />
L 350 28 513 8143 41<br />
L 6708 28 513 8513 42<br />
Z 341 28 512 3103 45<br />
B 2420 28 510 3997 28<br />
H 6380 28 510 2549 16<br />
N 42 A 28 510 0437 20<br />
Pt 6180 28 510 2232 22<br />
BXX 28 512 3806 45<br />
L 3504 28 513 8127 41<br />
L 6795 28 513 8681 40<br />
Z 342 28 512 3111 45<br />
B 2810 28 510 4011 28<br />
H 64 28 510 0231 16<br />
N 48 A 28 510 0445 20<br />
Pt 62 28 510 2019 22<br />
EE 28 512 3571 45<br />
L 400 28 513 8727 39<br />
L 687 28 513 8102 38<br />
Z 371 28 512 3255 45<br />
B 2820 28 510 4028 28<br />
H 65 28 510 0248 16<br />
N 48 BNC 28 510 1569 20<br />
Pt 6280 28 510 2249 22<br />
K 1 A 28 512 0217 37<br />
L 4004 28 513 8032 39<br />
L 6874 28 513 8016 38<br />
Z 451 28 512 3136 45<br />
B 2910 28 510 4044 28<br />
H 6580 28 510 2565 16<br />
N 50 A 28 510 0453 20<br />
Pt 6580 28 510 2257 22<br />
K 1 BNC 28 512 1213 37<br />
L 401 28 513 8098 38<br />
L 700 28 513 8735 39<br />
Z 461 28 512 3152 45<br />
B 2920 28 510 4052 28<br />
L 32 A 28 510 0289 20<br />
N 52 A 28 510 0494 20<br />
Pt 6880 28 510 0075 22<br />
K 1 H 28 512 1119 37<br />
L 4014 28 513 8008 38<br />
L 7004 28 513 8049 39<br />
Z 462 28 512 3169 45<br />
B 3410 28 510 4077 28<br />
L 32 BNC 28 510 0297 20<br />
N 52 BNC 28 510 5451 20<br />
Pt 6980 28 510 2265 22<br />
K 1 MN 28 512 1419 37<br />
L 420 28 513 8587 41<br />
L 918 28 513 8119 38<br />
Z 472 28 512 3185 45<br />
B 3420 28 510 4085 28<br />
L 39 A 28 510 0318 20<br />
N 5800 A 28 510 5127 18<br />
Pt 737 A 28 510 0153 24<br />
K 1 NN 28 512 1513 37<br />
L 4204 28 513 8608 41<br />
L 9184 28 513 8024 38<br />
Z 50 28 512 2961 45<br />
B 3510 28 510 4106 28<br />
L 39 BNC 28 510 0326 20<br />
N 5800 BNC 28 510 5579 18<br />
Pt 8280 28 510 2281 22<br />
K 1 S 28 512 1616 37<br />
L 430 28 513 8184 43<br />
LB 1 A 28 512 2653 37<br />
Z 501 28 512 3193 45<br />
B 3520 28 510 4114 28<br />
L 6880 28 510 1211 16<br />
N 5900 A 28 510 5135 18<br />
W 2030 28 510 4509 34<br />
KXX 28 512 3703 45<br />
L 4304 28 513 8168 43<br />
LB 1 BNC 28 512 2661 37<br />
Z 505 28 512 3206 45<br />
B 3610 28 510 0091 28<br />
L 7137 A 28 510 4582 20<br />
N 6000 A 28 510 5151 18<br />
W 2130 28 510 4496 34<br />
L 1 A 28 512 2456 37<br />
L 4619 28 513 8373 43<br />
LB 3 A 28 512 2678 37<br />
Z 506 28 512 3214 45<br />
B 3920 28 510 4163 28<br />
L 7237 A 28 510 4599 20<br />
N 6000 BNC 28 510 5632 18<br />
W 5780 NN 28 510 5221 34<br />
L 1 BNC 28 512 2497 37<br />
L 4643 28 513 8357 43<br />
LC 1002 K 28 513 9201 40<br />
Z 512 28 512 9509 45<br />
BlueLine11pH 28 512 9114 8<br />
L 7237 BNC 28 510 1174 20<br />
N 61 28 510 0001 16<br />
W 5790 NN 28 510 5254 34<br />
L 1 D 28 512 2559 37<br />
L 4648 28 513 8784 43<br />
LC 4002 K 28 513 9148 40<br />
9907/21 28 512 4716 37<br />
BlueLine12pH 28 512 9122 8<br />
L 737 A 28 510 4574 20<br />
N 6180 28 510 0018 16<br />
W 5790 PP 28 510 5776 34<br />
L 1 DP 28 512 2604 37<br />
L 4655 28 513 8673 40<br />
LC 7002 K 28 513 9172 40<br />
9909/31 28 512 5618 37<br />
BlueLine13pH 28 512 9139 10<br />
L 737 BNC 28 510 1071 20<br />
N 61eis 28 509 2661 16<br />
W 5791 NN 28 510 5262 34<br />
L 1 EE 28 512 2501 37<br />
L 4660 28 513 8381 43<br />
LF 906 28 513 8616 43<br />
9910/11 28 512 5515 37<br />
BlueLine14pH 28 512 9147 8<br />
L 7780 28 510 1252 18<br />
N 62 28 510 0034 16<br />
W 5980 NN 28 510 5287 34<br />
L 1 R 28 512 2534 37<br />
L 4690 28 513 8398 39<br />
LF 990 28 512 6503 43<br />
9910/21 28 512 5215 37<br />
BlueLine15pH 28 512 9155 8<br />
L 8280 28 510 1277 18<br />
N 6250 28 510 0112 16<br />
9009/61 28 511 1664 32<br />
L 1 X 28 512 2407 37<br />
L 4691 28 513 8205 39<br />
LF 991 28 512 6511 43<br />
9919/21 28 512 5523 37<br />
BlueLine16pH 28 512 9163 10<br />
L 8880 28 510 1285 18<br />
N 6280 28 510 0042 16<br />
L 100 28 513 8719 39<br />
L 4694 28 513 8213 39<br />
LF 992 28 512 6528 43<br />
9919/41 28 512 5548 37<br />
BlueLine17pH 28 512 9171 8<br />
LF 1050 28 510 4809 30<br />
N 64 28 510 0059 16<br />
L 1004 28 513 8057 39<br />
L 4697 28 513 8221 39<br />
LF 995 28 512 6293 43<br />
BlueLine18pH 28 512 9188 8<br />
LF 1100 28 510 4817 30<br />
N 6480eis 28 509 2337 16<br />
L 101 28 513 6956 41<br />
L 4698 28 513 8192 39<br />
LF 999/Set 28 512 6174 43<br />
BlueLine21pH 28 512 9217 10<br />
LF 1100 T 28 510 5813 30<br />
N 6480eth 28 509 2329 16<br />
L 1254 28 513 8649 41<br />
L 4790 28 513 8402 38<br />
LF 1000/Set 28 512 6166 43<br />
BlueLine22pH 28 512 9225 8<br />
LF 1200 28 510 4825 30<br />
N 65 28 510 0067 16<br />
L 168 28 513 7841 38<br />
L 4791 28 513 7977 38<br />
LS 1 ANN 28 512 2707 37<br />
BlueLine23pH 28 512 9233 8<br />
LF 4100 28 510 4866 30<br />
N 6580 28 510 2516 16<br />
L 1684 28 513 7677 38<br />
L 4794 28 513 8246 38<br />
LS 1 BNCNN 28 512 2723 37<br />
BlueLine24pH 28 512 9241 8<br />
LF 5100 28 510 4944 30<br />
N 6980 28 510 1709 16<br />
L 200 28 513 8151 41<br />
L 4796 28 513 8254 38<br />
LS 3 ANN 28 512 2715 37<br />
BlueLine25pH 28 512 9258 8<br />
LF 5100 T 28 510 4952 30<br />
Na 61 28 510 0026 32<br />
L 2004 28 513 8365 41<br />
L 4797 28 513 7985 38<br />
LS 3 BNCNN 28 512 2731 37<br />
BlueLine26pH 28 512 9266 8<br />
LF 513 T 28 510 6037 30<br />
NH 1100 28 510 2808 32<br />
L 2114 28 513 8349 41<br />
L 4798 28 513 8238 38<br />
NH 928 28 512 6482 45<br />
BlueLine27pH 28 512 9274 10<br />
LF 613 T 28 510 6131 30<br />
OX 1100 28 510 4603 32<br />
L 2214 28 513 6923 41<br />
L 4799 28 513 8262 38<br />
NH 995 28 512 6499 45<br />
BlueLine28pH 28 512 9282 8<br />
LF 713 T 28 510 6189 30<br />
Pt 1200 28 510 3512 26<br />
L 2224 28 513 8332 41<br />
L 4804 28 513 9012 42<br />
OX 060 28 513 8287 42<br />
BlueLine31Rx 28 512 9311 10<br />
N 1041 A 28 510 0486 20<br />
Pt 1400 28 510 3537 26<br />
L 2604 28 513 9029 41<br />
L 4893/Set 28 513 8279 38<br />
OX 920 28 512 6606 42<br />
46<br />
47
SCHOTT Instruments GmbH<br />
Hattenbergstrasse 10<br />
55122 Mainz<br />
Germany<br />
Phone: +49 (0) 61 31 / 66 -51 11<br />
Fax:<br />
+49 (0) 61 31 / 66 -50 01