Centrifugal pumps<br />
Multistage<br />
centrifugal pump FM<br />
Step 2:<br />
Find t he power consumpt ion of t he pump at t he point in t he diagramm where t he power<br />
curve meets the design flow rate. Select the motor with the next higher power rating.<br />
From the diagram: N = 6.7 kW, selected motor: 7.5 kW<br />
The selection is carried out the same way as single-stage centrifugal pumps FP are selected<br />
(See page 28).