DH6/10

DH6/10 DH6/10

07.11.2014 Views

For DC power supply double solenoid with LVDT feedback CFW-B15-D C series ■Performance Linearity 2% FS or below Constant current characteristic Step response Supply voltage fluctuation Change of load resistance Change of ambient temperature 30 ms(0→100%) 1% FS or below (21 to 30 V) 1.5% FS or below (5 to 11 ) 1% FS or below (0 to 50) ■Precautions in use ● This controller has internal heat generation. Do not install in a closed place. In addition, when more than one set are installed, keep the distance of 20 mm or more. ● Use a shielded cable for input signal wiring to protect it from noise. ● Set the "VALVE SIZE" selection switch to the prescribed position corresponding to the valve size. ■Connection method Please refer to the operation manual. (Note) Step response is measured while the solenoid is connected. FS (Full Scale) means the rating of 1500 mA. ■Specifications DC power supply Power consumption Input command Dither adjustment Type Solenoid coil resistance Maximum output current Input impedance Input gain adjustment Voltage input Resistance input Frequency Bias adjustement Zero point adjustement Monitor output (Spool displacement amount) Ambient temperatureand humidity Vibration proof Amplitude CFW-B15-D24-20 DC24 V (21 to 30 V) 30 VA or lower 11 or lower 1.5 A 50 kΩ DC 0 to ±10 Vmax. Variable resistance5 k (0.5 W or higher) 70 to 300 mA/V Fixed Fixed 0 to 500 mA ±20% FS 10 Vmax. 0 to 50, 90% RH or lower (No condensation) Conforming to JIS C0911 IIB, Class-3 Frequency 16.7 Hz, amplitude 3 mm P-P For DC power supply double solenoid with LVDT feedback Mass 1.0 kg ■Dimension drawing 190 180 170 0V 1 -V 2 SIG. 3 +V POWER 4 SOLA MIN 5 MAX GAIN + 6 MIN A - MAX 7 BIAS.A SOLB MIN 8 MAX BIAS.B + 9 - A - + 10 O.AD.J DC24V + 11 - FUSE 12 DT1 13 DT2 LVDT 14 6 VALVE DT3 SIZE 15 16 DT4 22 16 OUT MONI 17 TOR OV 18 CWF-B15 -D24-20 G 19 1.5 60 2-φ5 4 16 168.5 150 1 6-39

For DC power supply single and double solenoids – small and inexpensive type KCKWC KC series KWC series Performance Linearity 2% FS or below For DC power supply single and double solenoids – small and inexpensive type Precautions in use This controller has internal heat generation. Do not install in a closed place. Use a shielded cable for input signal wiring to protect it from noise. Connection method Please refer to the operation manual. Specifications Type Power supply Power consumption Solenoid coil resistance Maximum output current Input impedance Voltage input Input command Resistance input Input gain adjustment Constant current characteristic Step response Supply voltage fluctuation Change of load resistance Change of ambient temperature (Note) Step response is measured while the solenoid is connected. FS (Full Scale) means the rating of 800 mA. DC0 to 5 V (7.5 Vmax.) 100 ms0→100 2% FS or less (21 to 31V) 2% FS or less (14 to 21Ω) 1.5% FS or less (0 to 50) DC24 V (21 to 30 V) 20 VA or lower 14 to 21 or lower DC0 to 5 V (7.5 Vmax.) Possible by connecting a set station KSA series 120 to 200 mA/V PWM frequency variable range 50 to 250 Hz Accessories Type: KC-B10-11 Spare fuse 1 piece Bias adjustement Ramp adjustment Voltage monitor (cp + terminal) output Ambient temperatureand humidity 0 to 400 mA 0.1 to 5 seconds (Adjustment up or down independently is possible) 0 to 50, 90% RH or lower (No condensation) Type; KWC-B10-10 Spare fuse None Vibration proof Conforming to JIS C5025 class A Sweeping frequency 10 to 55 Hz, amplitude 1.5 mm P-P Mass Dimension drawing 5 Through-hole 2-5 (M4 mounting holes) Fuse Protection cover Power supply terminal Input terminal Output terminal Protection cover Slow-time adjustment trimmer Output current check pin Gain adjustment trimmer Bias adjustment trimmer PWM frequency trimmer Power indicator lamp (Red) 6-40

For DC power supply double solenoid with LVDT feedback CFW-B15-D<br />

C series<br />

■Performance<br />

Linearity<br />

2% FS or below<br />

Constant current<br />

characteristic<br />

Step response<br />

Supply voltage<br />

fluctuation<br />

Change of load<br />

resistance<br />

Change of ambient<br />

temperature<br />

30 ms(0→<strong>10</strong>0%)<br />

1% FS or below (21 to 30 V)<br />

1.5% FS or below (5 to 11 )<br />

1% FS or below (0 to 50)<br />

■Precautions in use<br />

● This controller has internal heat<br />

generation. Do not install in a closed place.<br />

In addition, when more than one set are<br />

installed, keep the distance of 20 mm or<br />

more.<br />

● Use a shielded cable for input signal wiring<br />

to protect it from noise.<br />

● Set the "VALVE SIZE" selection switch to the<br />

prescribed position corresponding to the<br />

valve size.<br />

■Connection method<br />

Please refer to the operation manual.<br />

(Note) Step response is measured while the solenoid is connected.<br />

FS (Full Scale) means the rating of 1500 mA.<br />

■Specifications<br />

DC power supply<br />

Power consumption<br />

Input command<br />

Dither adjustment<br />

Type<br />

Solenoid coil resistance<br />

Maximum output current<br />

Input impedance<br />

Input gain adjustment<br />

Voltage input<br />

Resistance input<br />

Frequency<br />

Bias adjustement<br />

Zero point adjustement<br />

Monitor output (Spool displacement amount)<br />

Ambient temperatureand humidity<br />

Vibration proof<br />

Amplitude<br />

CFW-B15-D24-20<br />

DC24 V (21 to 30 V)<br />

30 VA or lower<br />

11 or lower<br />

1.5 A<br />

50 kΩ<br />

DC 0 to ±<strong>10</strong> Vmax.<br />

Variable resistance5 k (0.5 W or higher)<br />

70 to 300 mA/V<br />

Fixed<br />

Fixed<br />

0 to 500 mA<br />

±20% FS<br />

<strong>10</strong> Vmax.<br />

0 to 50, 90% RH or lower (No condensation)<br />

Conforming to JIS C0911 IIB, Class-3<br />

Frequency 16.7 Hz, amplitude 3 mm P-P<br />

For DC power supply double solenoid with LVDT feedback<br />

Mass<br />

1.0 kg<br />

■Dimension drawing<br />

190<br />

180<br />

170<br />

0V 1<br />

-V<br />

2<br />

SIG.<br />

3<br />

+V<br />

POWER<br />

4<br />

SOLA<br />

MIN<br />

5<br />

MAX<br />

GAIN<br />

+ 6<br />

MIN A<br />

-<br />

MAX<br />

7<br />

BIAS.A<br />

SOLB<br />

MIN<br />

8<br />

MAX<br />

BIAS.B<br />

+ 9<br />

- A<br />

-<br />

+<br />

<strong>10</strong><br />

O.AD.J DC24V<br />

+ 11<br />

-<br />

FUSE<br />

12<br />

DT1<br />

13<br />

DT2<br />

LVDT<br />

14<br />

6<br />

VALVE<br />

DT3<br />

SIZE<br />

15<br />

16<br />

DT4<br />

22<br />

16<br />

OUT<br />

MONI 17<br />

TOR<br />

OV<br />

18<br />

CWF-B15<br />

-D24-20<br />

G<br />

19<br />

1.5<br />

60 2-φ5<br />

4<br />

16<br />

168.5<br />

150<br />

1<br />

6-39