DH6/10

DH6/10 DH6/10

07.11.2014 Views

Check valve S-(2)C Type indication Sandwich type Check valve C = Single type 2C = Double type Nominal dimension 6, 10 Series number: 11 Specifications Nominal dimension 6 10 Maximum working pressure MPa (kgf/cm 2 ) 30.9 (315) Maximum flow rate L/min Cracking pressure MPa (kgf/cm 2 ) Mass kg 40 100 0.05 (0.5) 0.9 2.4 Type of hydraulic oil No symbol Mineral based hydraulic oil V Phosphate ester based hydraulic oil W Fatty ester based hydraulic oil Water-glycol based hydraulic oil Cracking pressure 05 = 0.05MPa (0.5kgf/cm 2 ) Check valve incorporated port symbol C 2C Symbol Check valve incorporated port T Port T P Port P A Port A B Port B C Port A D Port B Port A E Port B Direction of free flow T T1 P1 P A1 A B1 B A A1 B B1 A A1 B B1 Mounting bolt Type Hexagon socket head cap thread Quantity Tightening torque Nm (kgfcm 2 ) C6 C10 M585L M685L 4 pcs. 4 pcs. 6.40.5 655 13 1 (13310 When the solenoid valve is 10 Series, mounting bolts are as shown in the table below. Type Hexagon socket head cap thread Quantity Tightening torque Nm (kgfcm 2 ) Check valve Pressure drop characteristics (viscosity 36 mm 2 /s (cSt)) S-(2)C6 S-(2)C10 C6 M590L 4 pcs. 7.40.5 75 5 C10 M6100L 4 pcs. 11.8 1.712018 When the throttle valve is fully open and the check valve is free flow Pressure drop amount (MPa) Pressure drop amount (MPa) Flow rate (L/min) Flow rate (L/min) 4-2

Hydraulic symbols (Note) P1, A1, B1 and T1 show ports on the sub-plate side while P, A, B and T show ports on the selector valve side. Check valve 4-3

Check valve<br />

S-(2)C<br />

<br />

<br />

<br />

<br />

Type indication<br />

Sandwich type<br />

Check valve<br />

C = Single type<br />

2C = Double type<br />

Nominal dimension<br />

6, <strong>10</strong><br />

Series number: 11<br />

Specifications<br />

Nominal dimension 6 <strong>10</strong><br />

Maximum working pressure MPa (kgf/cm 2 )<br />

30.9 (315)<br />

Maximum flow rate L/min<br />

Cracking pressure MPa (kgf/cm 2 )<br />

Mass kg<br />

40 <strong>10</strong>0<br />

0.05 (0.5)<br />

0.9 2.4<br />

Type of hydraulic oil<br />

No symbol<br />

Mineral based hydraulic oil<br />

V Phosphate ester based hydraulic oil<br />

W Fatty ester based hydraulic oil<br />

Water-glycol based hydraulic oil<br />

Cracking pressure<br />

05 = 0.05MPa (0.5kgf/cm 2 )<br />

Check valve incorporated port symbol<br />

C<br />

2C<br />

Symbol Check valve incorporated port<br />

T Port T<br />

P Port P<br />

A Port A<br />

B Port B<br />

C Port A<br />

D Port B<br />

Port A<br />

E<br />

Port B<br />

Direction of free flow<br />

T T1<br />

P1 P<br />

A1 A<br />

B1 B<br />

A A1<br />

B B1<br />

A A1<br />

B B1<br />

Mounting bolt<br />

Type Hexagon socket head cap thread Quantity Tightening torque Nm (kgfcm 2 )<br />

C6<br />

C<strong>10</strong><br />

M585L<br />

M685L<br />

4 pcs.<br />

4 pcs.<br />

6.40.5 655<br />

13 1 (133<strong>10</strong><br />

When the solenoid valve is <strong>10</strong> Series, mounting bolts are as shown in the table below.<br />

Type Hexagon socket head cap thread Quantity Tightening torque Nm (kgfcm 2 )<br />

Check valve<br />

Pressure drop characteristics (viscosity 36 mm 2 /s (cSt))<br />

S-(2)C6<br />

S-(2)C<strong>10</strong><br />

C6<br />

M590L<br />

4 pcs. 7.40.5 75 5<br />

C<strong>10</strong><br />

M6<strong>10</strong>0L 4 pcs. 11.8 1.712018<br />

When the throttle valve is fully open and the check valve is free flow<br />

Pressure drop amount (MPa)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Pressure drop amount (MPa)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Flow rate (L/min)<br />

Flow rate (L/min)<br />

4-2