Pressure reducing valve – Balanced piston type pilot operated PRB Primary pressure pilot type Overview This balanced piston type pilot operated pressure reducing valve is used for reducing the pressure of the hydraulic circuit partly. Even if the pressure of the main circuit on the primary side fluctuates, it is possible to keep the circuit pressure on the secondary side (low pressure side) at the specified pressure. Type indication PRB Features 1. As nominal dimension #10 leads the pilot pressure from the secondary side, the structure is compact. 2. As nominal dimension #20 and 30 lead the pilot pressure from the primary side, the maximum flow rate is large and besides they can control the secondary pressure stably. 3. When the remote control valve is connected to the drain port, the secondary pressure can be controlled by remote control. Pressure reducing valve – Balanced piston type pilot operated Pressure reducing valve – Balanced piston type pilot operated Nominal dimension 10, 20, 30 Connection method P = Gasket connection type Series number: 10 Shape of pressure adjusting part 1 = Handle adjustment 2 = Thread adjustment (with cap) 3 = Handle with key adjustment Hydraulic symbols Without check valve With check valve Specifications Type of hydraulic oil No symbol V W No symbol C = = = Drain system Y = External drain Mineral based hydraulic oil Phosphate ester based hydraulic oil Fatty ester based hydraulic oil Water-glycol based hydraulic oil Check valve provided or not = Without check valve = With check valve Highest adjustment pressure 100 = 9.8MPa100kgf/cm 2 315 = 30.9MPa315kgf/cm 2 Nominal dimension Maximum working pressure (port A, B, Y)MPa (kgf/cm 2 ) Maximum flow rate L/min Highest adjustment pressure MPa (kgf/cm 2 ) Mass kg (Note) As the minimum adjustment pressure varies depending on the flow rate, refer to “Minimum adjustment pressure characteristics on the secondary side”. 2-51

Pressure override characteristics (viscosity 36 mm 2 /s (cSt)) PRB10 PRB 20 30 Secondary side pressure MPa Secondary side pressure MPa Flow rate (L/min) Flow rate (L/min) Pressure reducing valve – balanced piston type pilot operated Pressure drop characteristics (viscosity 36 mm 2 /s (cSt)) in the case of check valve free flow Pressure drop amountMPa Pilot valve The pilot valve used for the pressure reducing valve – balanced piston type pilot operated is as follows. If you need the pilot valve only, please specify “pilot valve type” and contact us. Flow rate (L/min) Nominal dimension Pilot valve type * (Note) * Same as the pilot relief valve for RB10, 20 and 30 (Note) The pressure adjusting system is shown. 1 = Handle adjusting type 2 = Thread adjusting type (with cap) 3 = Handle with key adjusting type PRB20X Pilot valve For PRB20, 30 Series number: 10 Shape of pressure adjusting part 1 = Handle adjustment 2 = Thread adjustment (with cap) 3 = Handle with key adjustment Type of hydraulic oil No symbol V W = = = Mineral based hydraulic oil Phosphate ester based hydraulic oil Fatty ester based hydraulic oil Water-glycol based hydraulic oil Highest adjustment pressure 100 = 9.8MPa100kgf/cm 2 315 = 30.9MPa315kgf/cm 2 2-52

Pressure reducing valve – Balanced piston type pilot operated<br />

PRB<br />

Primary pressure pilot type<br />

<br />

<br />

Overview<br />

This balanced piston type pilot operated pressure<br />

reducing valve is used for reducing the pressure<br />

of the hydraulic circuit partly. Even if the pressure<br />

of the main circuit on the primary side fluctuates,<br />

it is possible to keep the circuit pressure on the<br />

secondary side (low pressure side) at the<br />

specified pressure.<br />

Type indication<br />

PRB<br />

Features<br />

1. As nominal dimension #<strong>10</strong> leads the pilot<br />

pressure from the secondary side, the structure<br />

is compact.<br />

2. As nominal dimension #20 and 30 lead the<br />

pilot pressure from the primary side, the<br />

maximum flow rate is large and besides they<br />

can control the secondary pressure stably.<br />

3. When the remote control valve is<br />

connected to the drain port, the secondary<br />

pressure can be controlled by remote<br />

control.<br />

Pressure reducing valve – Balanced piston type pilot operated<br />

Pressure reducing valve<br />

– Balanced piston type pilot operated<br />

Nominal dimension<br />

<strong>10</strong>, 20, 30<br />

Connection method<br />

P = Gasket connection type<br />

Series number: <strong>10</strong><br />

Shape of pressure adjusting part<br />

1 = Handle adjustment<br />

2 = Thread adjustment (with cap)<br />

3 = Handle with key adjustment<br />

Hydraulic symbols<br />

Without check valve<br />

<br />

With check valve<br />

<br />

Specifications<br />

Type of hydraulic oil<br />

No symbol<br />

V<br />

W<br />

No symbol<br />

C<br />

=<br />

=<br />

=<br />

Drain system<br />

Y = External drain<br />

Mineral based hydraulic oil<br />

Phosphate ester based hydraulic oil<br />

Fatty ester based hydraulic oil<br />

Water-glycol based hydraulic oil<br />

Check valve provided or not<br />

= Without check valve<br />

= With check valve<br />

Highest adjustment pressure<br />

<strong>10</strong>0 = 9.8MPa<strong>10</strong>0kgf/cm 2 <br />

315 = 30.9MPa315kgf/cm 2 <br />

Nominal dimension <br />

Maximum working pressure (port A, B, Y)MPa (kgf/cm 2 )<br />

Maximum flow rate L/min<br />

<br />

<br />

Highest adjustment pressure MPa (kgf/cm 2 )<br />

<br />

Mass kg<br />

<br />

<br />

<br />

<br />

<br />

(Note) As the minimum adjustment pressure varies depending on the flow rate, refer to “Minimum adjustment<br />

pressure characteristics on the secondary side”.<br />