Maximum flow rate<br />

With DC solenoid DE6P-30***-WD*<br />

With AC/DC conversion type solenoid DE6P-30***-WR*<br />

Number of<br />

positions<br />

Position<br />

holding<br />

method<br />

Spool<br />

type<br />

symbol<br />

05<br />

a<br />

Hydraulic symbols<br />

A B<br />

P T<br />

b<br />

Flow direction<br />

of oil<br />

<strong>10</strong><br />

(<strong>10</strong>2)<br />

16<br />

(163)<br />

<strong>10</strong>0 <strong>10</strong>0<br />

25<br />

(255)<br />

P→A→B→T<br />

P→B→A→T<br />

31.5<br />

(321)<br />

35<br />

(357)<br />

<strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0<br />

<strong>10</strong><br />

(<strong>10</strong>2)<br />

Maximum flow rate L/min<br />

Flow direction<br />

of oil<br />

16<br />

(163)<br />

25<br />

(255)<br />

P→A<br />

31.5<br />

(321)<br />

35<br />

(357)<br />

<strong>10</strong>0 45 28 25 22<br />

<strong>10</strong><br />

(<strong>10</strong>2)<br />

Flow direction<br />

of oil<br />

16<br />

(163)<br />

25<br />

(255)<br />

P→B<br />

Working pressure MPa (kgf/cm 2 ) Working pressure MPa (kgf/cm 2 ) Working pressure MPa (kgf/cm 2 )<br />

31.5<br />

(321)<br />

35<br />

(357)<br />

<strong>10</strong>0 45 28 25 22<br />

55 35 23 19 17 55 35 23 19 17<br />

Solenoid operated directional valve<br />

08<br />

<strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0<br />

80 80 80 80 80<br />

78 78 78 78 75 78 78 78 78 75<br />

70 70 70 70 70 70 70 70 70 70<br />

<strong>10</strong><br />

90 90<br />

90 50 38<br />

42 26 20<br />

<strong>10</strong>0 58 38 31 29 <strong>10</strong>0 58 38 31 29<br />

62 48 30 25 23 62 48 30 25 23<br />

3 positions<br />

2<br />

Spring<br />

<br />

center<br />

type<br />

17<br />

07<br />

65 40 33<br />

85 85<br />

45 30 26<br />

32 32 32 32 32<br />

28 28 28 28 28<br />

85 52 30 26 24 85 52 30 26 24<br />

65 36 25 21 19 65 36 25 21 19<br />

52 44 44 44 44 52 44 44 44 44<br />

42 38 38 38 38 42 38 38 38 38<br />

13<br />

<strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0 <strong>10</strong>0<br />

20 15 <strong>10</strong> <strong>10</strong> 8 20 15 <strong>10</strong> <strong>10</strong> 8<br />

21<br />

85 85<br />

85 80 40<br />

35 23 20<br />

<strong>10</strong>0 56 36 28 24 <strong>10</strong>0 56 36 28 24<br />

74 43 28 20 19 74 43 28 20 19<br />

12<br />

85 85<br />

85 80 40<br />

35 23 20<br />

<strong>10</strong>0 56 36 28 24 <strong>10</strong>0 56 36 28 24<br />

74 43 28 20 19 74 43 28 20 19<br />

04<br />

a<br />

A B<br />

P T<br />

80 80 80 80 80<br />

20 16 16 15 13<br />

46 31 24 22 22<br />

32 23 19 18 18<br />

2<br />

Spring<br />

<br />

offset<br />

type<br />

03<br />

70 70 70 70 70<br />

50 50 50 50 50<br />

75 75 75 75 75<br />

65 65 65 65 65<br />

2 positions<br />

01<br />

<br />

26 17 13 11 <strong>10</strong><br />

53 35 23 19 17<br />

35 30 17 13 12<br />

1<br />

No spring<br />

<br />

type<br />

with detent<br />

04<br />

a<br />

A B<br />

P T<br />

b<br />

75 75 75 75 75<br />

70 70 70 70 70<br />

45 45<br />

40 30 27<br />

30 25 22<br />

50<br />

50 50 45 45<br />

45 42 40 40<br />

(Note) The relationship between the maximum flow rate and the voltage in the above table is as shown below.<br />

Constant regardless of<br />

voltage<br />

<strong>10</strong>0<br />

<strong>10</strong>0<br />

55<br />

At rated voltage<br />

(Saturation state of coil temperature increase)<br />

At 90% V of rated voltage<br />

(Saturation state of coil temperature increase)<br />