Pilot valve The type indication of the pilot valve used for the relief valve – balanced piston type pilot operated is as follows. If you need the pilot valve only, please specify “pilot valve type” and contact us. RB10X Pilot relief valve For RB10, 20, 30 Series number: 10 Shape of pressure adjusting part 1 = Handle adjustment 2 = Thread adjustment (with cap) 3 = Handle with key adjustment RBE10X Pilot relief valve For RBE10, 20, 30 Series number: 10 Vent circuit A Normal close B Normal open Shape of pressure adjusting part 1 = Handle adjustment 2 = Thread adjustment (with cap) 3 = Handle with key adjustment symbol B C CL Type of hydraulic oil No symbol = Mineral based hydraulic oil V = Phosphate ester based hydraulic oil W = Fatty ester based hydraulic oil Water-glycol based hydraulic oil Drain system No symbol = Internal drain Y = External drain Highest adjustment pressure 100 9.8MPa (100kgf/cm 2 ) 315 30.9MPa (315kgf/cm 2 ) Type of hydraulic oil No symbol = Mineral based hydraulic oil V = Phosphate ester based hydraulic oil W = Fatty ester based hydraulic oil W1 = Water-glycol based hydraulic oil Shock damping valve provided or not No symbol = Without shock damping valve S = With shock damping valve Electric connection symbol With DIN connector With DIN large connector With DIN large connector with lamp Input power supply A D R Relief valve – Balanced piston type pilot operated (1) Highest adjustment pressure 100 9.8MPa (100kgf/cm 2 ) 315 30.9MPa (315kgf/cm 2 ) Drain system No symbol = Internal drain Y = External drain Solenoid type W = Wet type (with standard emergency manual operation) Input voltage 12 24 100 200 12V 24V 100V 200V * For details of voltage specifications, refer to “Solenoid specifications” of the solenoid operated directional valve “DE5”. * For other power supply, please contact us. Input power supply A = Alternating current D = Direct current R = AC/DC conversion 2-13

3 Solenoid operated directional valve The type indication of the solenoid operated directional valve used for the relief valve with unloading function, three stage pressure relief valve and sequence valve is as follows. For details, please contact us. Relief valve – Balanced piston type pilot operated (1) Solenoid valve Nominal dimension 5 Connection method P Gasket connection type Series number: 10 Position holding method 2 = 2 position, spring offset type or 3 position, spring center type Spool type 01 02 14 Sol. a Solenoid type a A B P b T 05 08 W = Wet type (with standard emergency manual operation) Specifications Sol. a a A B P O T b Sol. b * Correspondence with RBE type vent circuit symbols is as follows. A=01 B=02 Solenoid specifications Type of hydraulic oil No symbol = Mineral based hydraulic oil V = Phosphate ester based hydraulic oil W = Fatty ester based hydraulic oil W1 = Water-glycol based hydraulic oil Electric connection symbol * For other power supply, please contact us. Input power supply A D R NOTE: In case of CL for DC power supply, there is polarity in the terminal. Refer to the section of the type number index “DE-6” for connection method. Input voltage 12 24 100 200 symbol B C CL With DIN connector With DIN large connector With DIN large connector with lamp 12V 24V 100V 200V Input power supply A = Alternating current D = Direct current R = AC/DC conversion Switching time ms Solenoid excitation AC DC, with rectifier AC Solenoid DC deenergized With rectifier Maximum ambient temperature 25 40 20 30 100 50 Power supply and voltage Solenoid type Power supply Number of connection terminals Symbol Frequency Hz 50 K-W1D/* K-G1DS/* AC 3 DC 2 W100 W200 G12 G24 60 50 60 Mass kg Single solenoid type Double solenoid type 1.0 1.4 Current value A Voltage V Holding Startup 100 0.57 1.81 100 0.58 1.82 110 200 0.54 0.28 1.69 0.85 200 0.29 0.88 220 0.25 0.80 12 24 2.17 1.08 Energized time Continuous rating Type of coil insulation H type Allowable voltage fluctuation 10 Surge killer Procedure for three terminal solenoid connection With varistor Solenoid type K-W1D Connection terminal part schematic diagram 2 1 K-W1D Connection procedure AC100V-50Hz AC200V-50Hz AC100V-60Hz AC200V-60Hz AC110V-60Hz AC220V-60Hz Connection between 1 and 2 Connection between 1 and 3 Connection between 1 and 2 2-14

3<br />

Solenoid operated directional valve<br />

The type indication of the solenoid operated directional valve used for the relief valve with unloading function, three stage pressure relief valve and sequence valve is as follows.<br />

For details, please contact us.<br />

Relief valve – Balanced piston type pilot operated (1)<br />

Solenoid valve<br />

Nominal dimension<br />

5<br />

Connection method<br />

P Gasket connection type<br />

Series number: <strong>10</strong><br />

Position holding method<br />

2 = 2 position, spring offset type<br />

or<br />

3 position, spring center type<br />

Spool type<br />

01<br />

02<br />

14<br />

Sol.<br />

a<br />

Solenoid type<br />

a<br />

A B<br />

P<br />

b<br />

T<br />

05<br />

08<br />

W = Wet type (with standard emergency manual operation)<br />

Specifications<br />

Sol.<br />

a<br />

a<br />

A B<br />

P<br />

O<br />

T<br />

b<br />

Sol.<br />

b<br />

* Correspondence with RBE type<br />

vent circuit symbols is as follows.<br />

A=01<br />

B=02<br />

Solenoid specifications<br />

Type of hydraulic oil<br />

No symbol = Mineral based hydraulic oil<br />

V = Phosphate ester based hydraulic oil<br />

W = Fatty ester based hydraulic oil<br />

W1 = Water-glycol based hydraulic oil<br />

Electric connection symbol<br />

<br />

* For other power supply, please contact us.<br />

Input power supply<br />

A D R<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

NOTE: In case of CL for DC power supply, there is<br />

polarity in the terminal.<br />

Refer to the section of the type number index<br />

“DE-6” for connection method.<br />

Input voltage<br />

12<br />

24<br />

<strong>10</strong>0<br />

200<br />

symbol<br />

B<br />

C<br />

CL<br />

<br />

<br />

<br />

<br />

With DIN connector<br />

With DIN large connector<br />

With DIN large connector with lamp<br />

12V<br />

24V<br />

<strong>10</strong>0V<br />

200V<br />

Input power supply<br />

A = Alternating current<br />

D = Direct current<br />

R = AC/DC conversion<br />

Switching time ms<br />

Solenoid excitation<br />

AC<br />

DC, with rectifier<br />

AC<br />

Solenoid<br />

DC<br />

deenergized<br />

With rectifier<br />

Maximum ambient temperature <br />

25<br />

40<br />

20<br />

30<br />

<strong>10</strong>0<br />

50<br />

Power<br />

supply<br />

and<br />

voltage<br />

Solenoid type<br />

Power supply<br />

Number of connection<br />

terminals<br />

Symbol<br />

Frequency Hz<br />

50<br />

K-W1D/*<br />

K-G1DS/*<br />

AC<br />

3<br />

DC<br />

2<br />

W<strong>10</strong>0<br />

W200 G12 G24<br />

60 50 60 <br />

Mass kg<br />

Single solenoid type<br />

Double solenoid type<br />

1.0<br />

1.4<br />

Current<br />

value A<br />

Voltage V<br />

Holding<br />

Startup<br />

<strong>10</strong>0<br />

0.57<br />

1.81<br />

<strong>10</strong>0<br />

0.58<br />

1.82<br />

1<strong>10</strong> 200<br />

0.54 0.28<br />

1.69 0.85<br />

200<br />

0.29<br />

0.88<br />

220<br />

0.25<br />

0.80<br />

12 24<br />

2.17 1.08<br />

<br />

Energized time<br />

Continuous rating<br />

Type of coil insulation<br />

H type<br />

Allowable voltage fluctuation<br />

<strong>10</strong><br />

Surge killer<br />

Procedure for three terminal solenoid connection<br />

<br />

With varistor<br />

Solenoid type<br />

K-W1D<br />

Connection terminal part<br />

schematic diagram<br />

2<br />

1<br />

K-W1D<br />

Connection procedure<br />

AC<strong>10</strong>0V-50Hz<br />

AC200V-50Hz<br />

AC<strong>10</strong>0V-60Hz<br />

AC200V-60Hz<br />

AC1<strong>10</strong>V-60Hz<br />

AC220V-60Hz<br />

Connection between 1 and 2<br />

Connection between 1 and 3<br />

Connection between 1 and 2<br />

2-14