Befehl<br />

I<br />

Ixxx(CR)<br />

or<br />

Ixxxxxxxx(CR)<br />

Funktion<br />

Identifier in Hex (000...7FF)<br />

11 Bit Standard Format<br />

or<br />

Identifier in Hex (00000000...1FFFFFFF) 29 Bit Extended Format<br />

L Lx(CR) Listen Mode Only (0...1)<br />

This setting determines whether only 11-bit or 11-bit and 29-bit are<br />

accepted by <strong>CAN</strong>-Acceptance-Code and <strong>CAN</strong>-Acceptance-Mask.<br />

Response: “List of parameters: (CR)OK(CR)” or “ERROR(CR)“<br />

0 – <strong>CAN</strong> Normal Mode (read and write)<br />

1 – <strong>CAN</strong> Listen Only Mode (listening only, read)<br />

Response: “List of parameters: (CR)OK(CR)” or “ERROR(CR)“<br />

A Axxxxxxxx(CR) <strong>CAN</strong>-Acceptance-Code x = (0...000007FF) 11 Bit Standard Format<br />

<strong>CAN</strong>-Acceptance-Code x = (0...1FFFFFFF) 29 Bit Extended Format<br />

x = 0 receives all <strong>CAN</strong>-Frames<br />

Response: “List of parameters: (CR)OK(CR)” or “ERROR(CR)“<br />

M Mxxxxxxxx(CR) <strong>CAN</strong>-Acceptance-Mask x = (0..000007FF) 11 Bit Standard Format<br />

<strong>CAN</strong>-Acceptance-Mask x = (0..1FFFFFFF) 29 Bit Extended Format<br />

R<br />

V<br />

N<br />

R0(CR)<br />

R1(CR)<br />

R2(CR)<br />

R3(CR)<br />

R4(CR)<br />

R5(CR)<br />

R6(CR)<br />

R7(CR)<br />

R8(CR)<br />

R9(CR)<br />

RA(CR)<br />

RB(CR)<br />

RC(CR)<br />

RD(CR)<br />

RE(CR)<br />

RF(CR)<br />

x = F receives all <strong>CAN</strong>-Frames<br />

Response: “List of parameters: (CR)OK(CR)” or “ERROR(CR)“<br />

600 bps <strong>RS232</strong>/<strong>RS485</strong> Baudrate (all 8 N 1)<br />

1200 bps<br />

2400 bps<br />

4800 bps<br />

9600 bps<br />

19200 bps<br />

38400 bps<br />

57600 bps<br />

115200 bps<br />

230000 bps<br />

500000 bps<br />

600000 bps<br />

750000 bps<br />

1000000 bps<br />

1500000 bps<br />

3000000 bps Other baud rates available on request<br />

Response: “ (CR)OK(CR)” or “ERROR(CR)”<br />

Software Version Number<br />

Response: „Software Version: x.x(CR)“<br />

<strong>Converter</strong> Nummer<br />

x = 0..F<br />

Response: „<strong>Converter</strong>-ID: xxxx xxxx(CR)“ x= 0..F