Version 1.3<br />

<strong>RA8806</strong><br />

Two Layers Character/Graphic LCD Controller<br />

6-2-3 Com/Seg Scan Direction<br />

<strong>RA8806</strong> supports a special feature to reverse the Common and Segment signal. User could use<br />

this feature to change the direction of cursor and display data. If use text rotate function and set<br />

CDIR = 1, then use could show text in vertical display. Please refer to Section 6-10-4.<br />

Table 6-7<br />

Reg. Bit_Num Description Reference<br />

MISC<br />

Bit 1<br />

Bit 0<br />

Define the order of Segment signals. (SDIR)<br />

Define the order of Common signals. (CDIR)<br />

REG[01h]<br />

SEG0 .............................................. SEG319<br />

COM0<br />

: Cursor Moving way<br />

:<br />

:<br />

:<br />

:<br />

:<br />

:<br />

:<br />

COM239<br />

(1) SDIR = 0<br />

SEG0 …………………………………. SEG319<br />

COM0<br />

:<br />

Cursor Moving way<br />

:<br />

:<br />

:<br />

:<br />

:<br />

:<br />

:<br />

COM239<br />

(2) SDIR = 1<br />

Figure 6-14 : Example for Change Segment Direction<br />

6-2-4 Idle Time Counter (ITCR)<br />

ITCR(REG[90h]) is used to determine the idle time during the LP peer-to-peer time. It has following<br />

meanings in function.<br />

1. Adjusting the Frame Rate.(By extending the scan time of each COM)<br />

2. Avoiding the generation of “Flicker”.<br />

The “Flicker” is generated by the violation of LCD scan cycle and Memory write cycle. “Flicker”<br />

means the noise of the scan data at such violation. By setting the ITCR, user can write the display<br />

memory only at “Idle” time to eliminate the “Flicker”.<br />

XCLK<br />

LP<br />

ITCR<br />

COM_SCAN<br />

T_COM<br />

Figure 6-15 : Idle Time Period<br />

<strong>RA8806</strong> scan time of each COM line can be calculated by the formulas.<br />

<strong>RAiO</strong> TECHNOLOGY INC. 38/193 www.raio.com.tw