OKRW2.702.303SS, Libra-3K Poly-phase Meter Handbook v1.0<br />
4.6 Returning a Meter<br />
If you wish to return a <strong>meter</strong>, call your Wasion sales representative for a Return<br />
Authorization. The entire <strong>meter</strong> should be returned with the Wasion supplied Return<br />
Authorization information form completed. Key information includes quantity, catalog<br />
number serial number(s) and a complete description of the problem. Your Wasion<br />
sales representative will provide return instructions.<br />
4.7 Cleaning<br />
4.8 Storage<br />
The Libra Meter is a durable device; however, it should be handled and stored with<br />
care. The temperature and humidity levels in storage are not critical; but extremes of<br />
either factor should be avoided.<br />
4.9 Troubleshooting Guide<br />
Table 3-1 Troubleshooting<br />
Symptom Probable Cause Remedy<br />
No display a. Circuit de-energized.<br />
b. Test link(s) open.<br />
c. Meter internal wiring<br />
defective.<br />
a. Rewire according to applicable<br />
diagram.<br />
b. Check that voltage and current<br />
connectors are seated properly.<br />
Check the leads for damage.<br />
c. Replace <strong>meter</strong>.<br />
High/low demand<br />
registration<br />
a. Socket wiring error.<br />
b. Meter interner wiring<br />
detective.<br />
c. Detective sensor.<br />
a. Rewire according to applicable<br />
diagram<br />
b. Check that voltage and current<br />
connectors are seated properly.<br />
Check the leads of damage.<br />
c. Replace <strong>meter</strong>.<br />
Meter runs slow a. Socket wiring error.<br />
b. Meter internal wiring<br />
defective.<br />
c. Defective sensor.<br />
a. Rewire according to applicable<br />
diagram.<br />
b. Check that voltage and current<br />
connectors are seated properly.<br />
Check the leads for damage.<br />
c. Replace <strong>meter</strong>.<br />
Meter overheats a. Meter socket has a. Replace <strong>meter</strong> socket with a<br />
OPERATING INSTRUCTIONS 30 / 35