VALLEY<br />

Where the valley meets the eaves beam, the angle between<br />

the eaves beam sections should be 90˚ as shown in<br />

diagram A). The situation as shown in diagram B) should<br />

be avoided especially with glass roofs:-<br />

7 SERIES LIGHT BAR<br />

DIAGRAM A)<br />

83 100 83<br />

Transom/Victorian Georgian Starter<br />

Note: add 5mm for chambered top capping heights.<br />

Minimum return<br />

300mm<br />

7 SERIES BAR<br />

Valley on 90˚<br />

eaves beam<br />

83 100 83<br />

DIAGRAM B) AVOID IF POSSIBLE<br />

Transom/Victorian Georgian Starter<br />

Note: add 5mm for chambered top capping heights.<br />

7 SERIES+REINFORCING BAR<br />

Valley on 135˚<br />

eaves beam<br />

This method requires<br />

a fabricated valley<br />

manufactured by<br />

<strong>Ultraframe</strong><br />

Transom/Victorian<br />

Georgian<br />

Note: add 5mm for chambered top capping heights.<br />

7 SERIES+BOLSTER BAR<br />

For information on maximum valley spans please use the UK<br />

Structural Design <strong>Guide</strong> (electronic version).<br />

GLAZING BARS<br />

There is a choice of 2 glazing bars - 7 light and 7 standard.<br />

7 standard is available with inserts for additional strength or<br />

with bolsters for additional performance. When ordering a<br />

complete roof, it is not necessary to state the glazing bar, as<br />

<strong>Ultraframe</strong> will select the appropriate bar for the roof in<br />

question. However, if required, further information on<br />

glazing bar spans can be found in the UK Structural Design<br />

<strong>Guide</strong> (electronic version).<br />

168<br />

73 73<br />

Transom/Victorian<br />

Georgian<br />

Note: add 5mm for chambered top capping heights.<br />

182<br />