S E C T I O N 5<br />

Designing the<br />

<strong>Ultraframe</strong> Roof<br />

This is where all conservatory designs should begin, from the<br />

roof down, top to bottom. There are occasions when either the<br />

conservatory is being built on an existing base or the base<br />

has to be in a particular position, otherwise design from the<br />

top down. The roof should be treated as a separate structure,<br />

although <strong>Ultraframe</strong> and its fabricators have to be flexible in<br />

that they can (in most cases) design the roof bar spacings to<br />

line through with the mullions in the conservatory wall frames -<br />

for aesthetic reasons the customer may expect this. How often<br />

has the PVCu cill been fabricated to suit the already built base<br />

(even when the base angles are inaccurate) then frames are<br />

manufactured to suit the cill then the roof fabricated to suit the<br />

frames? Wherever possible the roof design dictates the frame<br />

sizes, which decides the cill size, which determines the base<br />

size.<br />

DIAGRAM B<br />

multi eaves beam<br />

dimensions<br />

110mm<br />

There are three conservatory roofing systems available from<br />

<strong>Ultraframe</strong> (UK) Ltd:-<br />

1. Classic System<br />

Suitable for any shape or size of conservatory<br />

including Victorians, Edwardians, Lean-to, P-shape and<br />

combination of these styles.<br />

2. Ultralite 500 PVC<br />

Suitable only for lean-to conservatories. Especially suited<br />

for extremely low pitch applications such as bungalow<br />

installations (guaranteed down to 2 1 ⁄2˚ pitch). Standard<br />

pack sizes but cut on site if necessary.<br />

3. Elevation and Elevation Plus<br />

Modern low pitch polycarbonate ‘Click-lock’ system. Fully<br />

bespoke or ‘Roof-in-a-box’. Elevation Plus is a lean-to with<br />

hipped ends with roof pitch of 5˚ and hipped ends at<br />

28 1 ⁄2˚.<br />

4. Uzone<br />

Edwardian or 3 facet Victorian up to 4 x 4m at a set<br />

pitch of 22 1 ⁄2˚.<br />

Eaves beam<br />

always fits<br />

flush with<br />

inside face<br />

of frames<br />

Profile width<br />

58 - 70<br />

160mm<br />

Variable pitch from 15-35˚. For greater or lower pitches use glazing bar<br />

packers. (See diagram C)<br />

DIAGRAM C<br />

Glazing bar packers (to suit 5˚, 10˚, 35° and 40°)<br />

5˚ pitch 10˚ pitch 35˚ pitch 40˚ pitch<br />

THE CLASSIC SYSTEM<br />

The following sections illustrate options and dimensional<br />

information for the surveyor. For snow and wind loads<br />

applicable to particular locations please refer to ‘The UK<br />

Structural Design <strong>Guide</strong>’ (Electronic version) available from<br />

<strong>Ultraframe</strong>.<br />

Slide fixing bolts into position along the eaves beam captive<br />

bolt slot. Locate packer over bolts and position to suit<br />

required pitch (see sections above). Drop glazing bar onto<br />

bolts and fix down.<br />

EAVES BEAM - MULTI - STANDARD<br />

When specifying the Classic roof, the dimensions required are<br />

internal frame dimensions from point to point including any<br />

corner posts, bay-pole, structural mullions or jointing couplers<br />

that may have been used between the frames.<br />

Glazing<br />

Bar<br />

Nut<br />

Packer<br />

Bolts<br />

Eaves<br />

Beam<br />

13<br />

© ULTRAFRAME 2000