Download brochure as PDF - Nikon Instruments
Download brochure as PDF - Nikon Instruments
Download brochure as PDF - Nikon Instruments
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CFI60 OBJECTIVES<br />
1.7<br />
5.3<br />
32<br />
11<br />
10.8<br />
4.2<br />
30˚<br />
30˚<br />
3˚<br />
ø34.5<br />
ø30<br />
M25~0.75<br />
Plan Apo<br />
60X /0.95<br />
DIC M<br />
/ 0.11-0.23 WD 0.15<br />
11 14 17 20 23<br />
ø7<br />
ø18<br />
ø22<br />
ø33<br />
WD=0.15<br />
CG=0.17<br />
60.06<br />
CFI Plan Apochromat 60x C<br />
CFI Plan Apochromat DM 60x C<br />
ø30<br />
M25~0.75<br />
CFI Plan Apochromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM)<br />
3.7 4<br />
40<br />
12 5.3<br />
45˚<br />
22.5˚<br />
8˚<br />
ø33.5<br />
ø30<br />
M25~0.75<br />
Plan Apo<br />
60X /1.40 oil<br />
DIC H<br />
/ 0.17 WD 0.21<br />
ø7.2<br />
ø22<br />
ø25.8<br />
CG=0.17 WD=0.21 (oil)<br />
60.06<br />
CFI Plan Apochromat 60x Oil<br />
CFI Plan Apochromat DM 60x Oil<br />
ø30<br />
M25~0.75<br />
59.7 5.3<br />
23.5<br />
11<br />
11.9<br />
10.4<br />
2.9<br />
30˚<br />
7˚<br />
5˚<br />
30˚<br />
ø36.5<br />
ø35.2<br />
ø30<br />
M25~0.75<br />
Plan Apo<br />
60X /1.20 WI<br />
/ 0.15-0.18 WD 0.22<br />
15 16 17 18<br />
ø7.5<br />
ø29<br />
ø33.4<br />
CFI Plan Apochromat 60x WI<br />
CFI S Fluor Series<br />
These objectives ensure a high transmission rate of ultraviolet wavelengths down to 340 nm for fluorochromes like<br />
indo-1, fura-2, and fluor-3. Also, these objectives have improved signal-to-noise ratios (S/N) for short wavelengths and<br />
have high N.A., making the fluorescence images they produce significantly sharper and brighter.<br />
64<br />
5.3<br />
12<br />
38.5<br />
8.2<br />
ø32<br />
ø30<br />
M25~0.75<br />
S Fluor<br />
10 X / 0.50<br />
/ 0.17 WD 0.12<br />
ø8<br />
ø19<br />
ø24<br />
1.2<br />
64.2<br />
5.3<br />
5.9 41<br />
12<br />
ø33.5<br />
ø30<br />
M25~0.75<br />
S Fluor<br />
20 X / 0.75<br />
/ 0.17 WD 1.0<br />
ø9<br />
ø22<br />
ø25<br />
1<br />
5<br />
27<br />
3.1 8.5 10.5 10.5<br />
ø34.5<br />
ø33<br />
ø30<br />
M25~0.75<br />
Fluor 40 X / 0.9<br />
/ 0.11-0.23 WD 0.3<br />
11 14 17 20 23<br />
ø7.5<br />
ø18<br />
ø26<br />
ø33<br />
CFI S Fluor 10x<br />
CFI S Fluor 20x<br />
CFI S Fluor 40x C<br />
5.3<br />
59.8<br />
51.5<br />
Plan Apo<br />
100 X /1.40 oil<br />
DIC H<br />
/ 0.17 WD 0.13<br />
60.06<br />
59.8 5.3<br />
51.5<br />
Plan Apo<br />
00X /1.40 oilN<br />
/ 0 WD 0.17<br />
60<br />
5<br />
12<br />
ø32<br />
ø30<br />
M25~0.75<br />
5<br />
ø32<br />
ø30<br />
M25~0.75<br />
4.5<br />
3.8<br />
20˚<br />
C2<br />
ø5.8<br />
ø17<br />
ø21<br />
WD=0.13<br />
4.5<br />
3.8<br />
C2<br />
20˚<br />
ø5.8<br />
ø17<br />
ø21<br />
WD=0.17<br />
37<br />
S Fluor<br />
40 X / 1.30<br />
/ 0.17 WD 0.22<br />
Oil<br />
64.7<br />
32<br />
7.5<br />
7.5<br />
S Fluor<br />
100 X /0.5-1.3 oil<br />
/ 0.17 WD 0.2<br />
1.3 0.7<br />
CFI Plan Apochromat 100x Oil<br />
CFI Plan Apochromat DM 100x Oil<br />
CFI Plan Apochromat 100x NCG Oil<br />
6.5<br />
9.8<br />
Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />
CFI Plan Apochromat 2x 0.10 8.5 100.0 27.50 180<br />
CFI Plan Apochromat 4x 0.20 15.7 50.0 6.88 180<br />
CFI Plan Apochromat 10x 0.45 4.0 20.0 1.36 220<br />
CFI Plan Apochromat 20x 0.75 1.0 10.0 0.49 240 Spring-loaded<br />
CFI Plan Apochromat DM 20x 0.75 1.0 10.0 0.49 240 Spring-loaded ph2<br />
CFI Plan Apochromat 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />
CFI Plan Apochromat DM 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />
CFI Plan Apochromat 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper<br />
CFI Plan Apochromat DM 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper ph3<br />
CFI Plan Apochromat 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />
CFI Plan Apochromat DM 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />
CFI Plan Apochromat 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper<br />
CFI Plan Apochromat DM 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper ph3<br />
CFI Plan Apochromat 60x WI 1.20 0.22 3.3 0.25 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.15–0.18mm<br />
Water immersion<br />
CFI Plan Apochromat 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper<br />
CFI Plan Apochromat DM 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper ph3<br />
CFI Plan Apochromat 100x NCG Oil 1.40 0.17 2.0 0.21 245 Spring-loaded Stopper No cover gl<strong>as</strong>s<br />
4.2<br />
ø8.3<br />
ø20<br />
ø23.8<br />
CFI S Fluor 40x Oil<br />
Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />
CFI S Fluor 10x 0.50 1.2 10.0 1.10 275 Spring-loaded<br />
CFI S Fluor 20x 0.75 1.0 10.0 0.49 275 Spring-loaded<br />
CFI S Fluor 40x C 0.90 0.3 5.0 0.34 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />
CFI S Fluor 40x Oil 1.30 0.22 5.0 0.25 275 Spring-loaded<br />
CFI S Fluor 100x Oil 1.30 0.2 2.0 0.25 285 Spring-loaded<br />
2.9<br />
ø6<br />
ø17<br />
ø24<br />
ø29.5<br />
CFI S Fluor 100x Oil<br />
12<br />
13