CFI60 OBJECTIVES<br />

CFI Plan Fluor Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DLL)<br />

Featuring an extra-high transmission<br />

rate, especially in the ultraviolet<br />

wavelength, and flatness of field<br />

comparable to the CFI Plan Achromat<br />

series, these objectives are designed<br />

for fluorescence observation and<br />

photomicrography. Because of this<br />

improvement in quality, these<br />

objectives can function <strong>as</strong> multipurpose<br />

objectives for brightfield,<br />

fluorescence, polarizing, and DIC<br />

observations.<br />

The DLL (low contr<strong>as</strong>t) ph<strong>as</strong>e<br />

objectives for this series can also be<br />

used <strong>as</strong> universal objectives for<br />

ph<strong>as</strong>e contr<strong>as</strong>t, fluorescence, DIC,<br />

and brightfield techniques.<br />

5.3<br />

42.8<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

4X / 0.13<br />

/ - WD 17.1<br />

ø20<br />

CFI Plan Fluor 4x<br />

45˚<br />

5.3<br />

43.9<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

10X / 0.30<br />

DIC L@<br />

/0.17 WD 16.0<br />

ø18<br />

CFI Plan Fluor 10x<br />

CFI Plan Fluor DLL 10x<br />

45˚<br />

1.7<br />

5.3<br />

10.8 11<br />

32<br />

3.9<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

60X / 0.85<br />

DIC M<br />

/0.11-0.23 WD 0.30<br />

11 14 17 20 23<br />

ø8.5<br />

ø18<br />

ø22<br />

ø33<br />

30˚<br />

30˚<br />

5.3<br />

3.8 4.5<br />

51.5<br />

ø30<br />

Plan Fluor<br />

100X/1.30 oil<br />

DIC H<br />

/0.17 WD 0.20<br />

ø5.8<br />

ø17<br />

ø21<br />

20˚<br />

45˚<br />

6.2<br />

2.6<br />

5.3<br />

34<br />

2.9 6.5 7.5<br />

17˚<br />

ø33.4<br />

ø32<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

100X/0.5-1.3 oil<br />

/0.17 WD 0.2<br />

1.3 0.7<br />

ø5.3<br />

ø19.8<br />

ø23.6<br />

ø32<br />

C2.5<br />

8˚<br />

ø30<br />

M25~0.75<br />

ø30<br />

M25~0.75<br />

ø33.5<br />

ø30<br />

CFI Plan Fluor 60x C<br />

CFI Plan Fluor 100x Oil<br />

CFI Plan Fluor DLL 100x Oil<br />

CFI Plan Fluor 100x Oil with<br />

iris diaphragm<br />

5.3<br />

54<br />

Plan Fluor<br />

20X / 0.50<br />

DIC M<br />

/0.17 WD 2.1<br />

45˚<br />

5.3<br />

57.2<br />

5.5<br />

Plan Fluor<br />

40X / 0.75<br />

DIC M<br />

/0.17 WD 0.72<br />

40<br />

12 5.3<br />

45˚<br />

60.41<br />

Plan Fluor<br />

4X / 0.13<br />

PhL DL<br />

/1.2 WD 16.4<br />

45˚<br />

5<br />

42.8<br />

5.3<br />

M25~0.75<br />

Plan Fluor<br />

40X / 1.30 oil<br />

DIC H<br />

/0.17 WD 0.2<br />

CFI Plan Fluor Series for Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

These objectives have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t with tissue culture<br />

specimens. These objectives are designed for use on inverted microscopes and therefore their markings are<br />

upside-down for e<strong>as</strong>y reading.<br />

1.2<br />

45˚<br />

3.8<br />

2.7<br />

ø12<br />

ø17<br />

CFI Plan Fluor 20x<br />

CFI Plan Fluor DLL 20x<br />

2<br />

ø10<br />

45˚<br />

CFI Plan Fluor 40x<br />

CFI Plan Fluor DLL 40x<br />

4<br />

3.7<br />

23˚<br />

ø8<br />

ø22<br />

ø25.8<br />

CFI Plan Fluor 40x Oil<br />

60.41<br />

Plan Fluor<br />

10X / 0.30<br />

Ph1 DL<br />

/1.2 WD 15.2<br />

45˚<br />

6<br />

44<br />

5.3<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor 4x 0.13 17.1 50.0 16.27 110<br />

CFI Plan Fluor 10x 0.30 16.0 20.0 3.06 120<br />

CFI Plan Fluor DLL 10x 0.30 16.0 20.0 3.06 120 ph1<br />

CFI Plan Fluor 20x 0.50 2.1 10.0 1.10 175<br />

CFI Plan Fluor DLL 20x 0.50 2.1 10.0 1.10 175 ph1<br />

CFI Plan Fluor 40x 0.75 0.72 5.0 0.49 210 Spring-loaded<br />

CFI Plan Fluor DLL 40x 0.75 0.72 5.0 0.49 210 Spring-loaded ph2<br />

CFI Plan Fluor 40x Oil 1.30 0.2 5.0 0.25 230 Spring-loaded Stopper<br />

CFI Plan Fluor 60x C 0.85 0.3 3.3 0.38 265 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Fluor 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper<br />

CFI Plan Fluor DLL 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper ph3<br />

CFI Plan Fluor 100x Oil with iris diaphragm 0.5–1.3 0.2 2.0 0.25 285 Spring-loaded With iris diaphragm<br />

M25~0.75<br />

M25~0.75<br />

ø30<br />

ø30<br />

CFI Plan Fluor DL 4x<br />

CFI Plan Fluor DL 10x<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor DL 4x 0.13 16.4 50.0 16.27 105 Cover gl<strong>as</strong>s thickness 1.2mm phL<br />

CFI Plan Fluor DL 10x 0.30 15.2 20.0 3.06 120 Cover gl<strong>as</strong>s thickness 1.2mm ph1<br />