06.11.2014 Views

Download brochure as PDF - Nikon Instruments

Download brochure as PDF - Nikon Instruments

Download brochure as PDF - Nikon Instruments

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MICROSCOPE COMPONENTS<br />

FOR TRANSMITTED<br />

LIGHT APPLICATIONS<br />

Specifications and equipment are subject to change without any notice or<br />

obligation on the part of the manufacturer. June 2007. ©1997-07 NIKON CORPORATION<br />

NIKON CORPORATION<br />

Parale Mitsui Bldg., 8, Hig<strong>as</strong>hida-cho, Kaw<strong>as</strong>aki-ku,<br />

Kaw<strong>as</strong>aki, Kanagawa 210-0005, Japan<br />

phone: +81-44-223-2167 fax: +81-44-223-2182<br />

http://www.nikon-instruments.jp/eng/<br />

NIKON INSTRUMENTS INC.<br />

1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.<br />

phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only)<br />

fax: +1-631-547-0306<br />

http://www.nikonusa.com/<br />

NIKON INSTRUMENTS EUROPE B.V.<br />

P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands<br />

phone: +31-20-44-96-222 fax: +31-20-44-96-298<br />

http://www.nikon-instruments.com/<br />

NIKON INSTRUMENTS (SHANGHAI) CO., LTD.<br />

CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030<br />

(Beijing office) phone: +86-10-5869-2255 fax: +86-10-5869-2277<br />

(Guangzhou office) phone: +86-20-3882-0552 fax: +86-20-3882-0580<br />

NIKON SINGAPORE PTE LTD<br />

SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668<br />

NIKON MALAYSIA SDN. BHD.<br />

MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387<br />

NIKON INSTRUMENTS KOREA CO., LTD.<br />

KOREA phone: +82-2-2186-8410 fax: +82-2-555-4415<br />

NIKON CANADA INC.<br />

CANADA phone: +1-905-625-9910 fax: +1-905-625-0103<br />

NIKON FRANCE S.A.S.<br />

FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33<br />

NIKON GMBH<br />

GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322<br />

NIKON INSTRUMENTS S.p.A.<br />

ITALY phone: +39-55-3009601 fax: +39-55-300993<br />

NIKON AG<br />

SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861<br />

NIKON UK LTD.<br />

UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584<br />

NIKON GMBH AUSTRIA<br />

AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40<br />

NIKON BELUX<br />

BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45<br />

Printed in Japan (0706-03)T Code No. 2CE-MUZH-3 This <strong>brochure</strong> is printed on recycled paper made from 40% used material.<br />

En


Contents<br />

System Diagram<br />

2<br />

System Diagram .............................. 3<br />

CFI 60 Objectives<br />

CFI Achromat Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)............ 4~5<br />

CFI Achromat 4x<br />

CFI Achromat 10x / CFI Achromat DL 10x<br />

CFI Achromat LWD 20x / CFI Achromat LWD DL 20x<br />

CFI Achromat 40x / CFI Achromat DL 40x<br />

CFI Achromat 60x<br />

CFI Achromat 100x Oil / CFI Achromat DL 100x Oil<br />

CFI Achromat LWD DL 20x F<br />

CFI Achromat LWD 40x C / CFI Achromat LWD DL 40x C<br />

CFI Plan Achromat Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL) ............ 6~7<br />

CFI Plan Achromat UW 1x<br />

CFI Plan Achromat UW 2x<br />

CFI Plan Achromat 4x<br />

CFI Plan Achromat 10x / CFI Plan Achromat DL 10x<br />

CFI Plan Achromat 20x / CFI Plan Achromat DL 20x<br />

CFI Plan Achromat 40x / CFI Plan Achromat DL 40x<br />

CFI Plan Achromat 40x NCG<br />

CFI Plan Achromat 50x Oil<br />

CFI Plan Achromat 100x Oil / CFI Plan Achromat DL 100x Oil<br />

CFI Plan Achromat 100x NCG<br />

CFI Plan Fluor Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DLL) .......... 8~9<br />

CFI Plan Fluor 4x<br />

CFI Plan Fluor 10x / CFI Plan Fluor DLL 10x<br />

CFI Plan Fluor 20x / CFI Plan Fluor DLL 20x<br />

CFI Plan Fluor 40x / CFI Plan Fluor DLL 40x<br />

CFI Plan Fluor 40x Oil<br />

CFI Plan Fluor 60x C<br />

CFI Plan Fluor 100x Oil / CFI Plan Fluor DLL 100x Oil<br />

CFI Plan Fluor 100x Oil with iris diaphragm<br />

CFI Plan Fluor Series for Ph<strong>as</strong>e Contr<strong>as</strong>t (DL).... 9<br />

CFI Plan Fluor DL 4x<br />

CFI Plan Fluor DL 10x<br />

CFI Plan Fluor ELWD Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM/DLL) ........ 10<br />

CFI Plan Fluor ELWD 20x C / CFI Plan Fluor ELWD DM 20x C<br />

CFI Plan Fluor ELWD 40x C / CFI Plan Fluor ELWD DM 40x C<br />

CFI Plan Fluor ELWD 60x C / CFI Plan Fluor ELWD DLL 60x C<br />

Multi-Immersion Objective for Brightfield .....<br />

CFI Plan Fluor 20x MI<br />

CFI Plan Apochromat Series<br />

10<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM) ......... 11~12<br />

CFI Plan Apochromat 2x<br />

CFI Plan Apochromat 4x<br />

CFI Plan Apochromat 10x<br />

CFI Plan Apochromat 20x / CFI Plan Apochromat DM 20x<br />

CFI Plan Apochromat 40x C / CFI Plan Apochromat DM 40x C<br />

CFI Plan Apochromat 40x Oil / CFI Plan Apochromat DM 40x Oil<br />

CFI Plan Apochromat 60x C / CFI Plan Apochromat DM 60x C<br />

CFI Plan Apochromat 60x Oil / CFI Plan Apochromat DM 60x Oil<br />

CFI Plan Apochromat 60x WI<br />

CFI Plan Apochromat 100x Oil / CFI Plan Apochromat DM 100x Oil<br />

CFI Plan Apochromat 100x NCG Oil<br />

CFI S Fluor Series.......................................... 13<br />

CFI S Fluor 10x<br />

CFI S Fluor 20x<br />

CFI S Fluor 40x C<br />

CFI S Fluor 40x Oil<br />

CFI S Fluor 100x Oil<br />

Water Dipping Series.................................... 14<br />

CFI Fluor 10x W<br />

CFI Fluor 40x W<br />

CFI Fluor 60x W<br />

CFI HMC Series<br />

for Hoffmann Modulation Contr<strong>as</strong>t ® .............. 15<br />

CFI HMC 10x<br />

CFI HMC 20x F<br />

CFI HMC LWD 40x C<br />

2nd Objective Lens Unit ............................... 15<br />

Markings on CFI60 Objectives........................ 16<br />

17<br />

Condensers....................................<br />

C-C Abbe Condenser, Dry Type<br />

C-C Achromat Condenser<br />

Achromat Swing-out Condenser<br />

C-C Achromat /Aplanat Condenser<br />

LWD Achromat Condenser<br />

C-C Low Power Condenser<br />

Dark Field Condenser, Oil<br />

Dark Field Condenser, Dry<br />

C-CEL Expander Lens (for darkfield)<br />

Illumination Systems ................ 18~19<br />

Lamphouse HMX-3B<br />

Lamphouse HMX-4B, built-in back mirror<br />

Lamphouse HMX<br />

Mercury Lamp Socket S 100W for HMX-3B<br />

Halogen Lamp Socket 100W/HMX<br />

C-FC Epi-Fl Collector Lens<br />

Quartz Epi-Fl Collector Lens<br />

Collector Lens/QH100W<br />

C-LA HMX Lamphouse Adapter<br />

HMX Connecting Adapter SB-X1 (Bayonet to Screw)<br />

HMX Connecting Adapter SB-X2 (Screw to Bayonet)<br />

Eyepiece Tubes .............................. 19<br />

Y-TB Binocular Tube<br />

Y-TE Ergonomic Binocular Tube<br />

Y-TF Trinocular Tube “F” UW<br />

Y-TT Trinocular Tube “T” UW<br />

Intermediate Tubes ....................... 20<br />

Y-FL Epi-Fl Attachment<br />

Y-IDP Double Port<br />

Eyepieces......................................<br />

CFI 10x with diopter adjustment<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment<br />

CFI 12.5x with diopter adjustment<br />

CFI 15x with diopter adjustment<br />

20<br />

Nosepiece ...................................... 21<br />

V-NA Motorized Sextuple Nosepiece<br />

V-ND MG-DIC Intelligent Sextuple Nosepiece<br />

C-N Sextuple Nosepiece<br />

C-ND Sextuple DIC Nosepiece<br />

CCTV Camera Adapters ............. 22~23<br />

V-T Photo Adapter<br />

Y-T TV Tube for C-Mount Adapter A<br />

C-Mount TV Adapter A<br />

Relay Lens 1x I<br />

C-Mount TV Adapter<br />

ENG-Mount TV Adapter<br />

Zoom Lens<br />

C-Mount Zooming Adapter<br />

ENG-Mount Zooming Adapter<br />

C-Mount TV Adapter 0.45x<br />

C-Mount TV Adapter 0.6x<br />

ENG-Mount TV Adapter 0.45x (for Trinocular Tube “F”, “T”)<br />

ENG-Mount TV Adapter 0.6x (for Trinocular Tube “F”, “T”)<br />

C-Mount TV Adapter VM 2.5x<br />

C-Mount TV Adapter VM 4x<br />

Mercury Lamp<br />

Socket S 100W<br />

Halogen Lamp<br />

Socket 100W/HMX<br />

C-C Abbe Condenser<br />

(Dry)<br />

ENG-Mount CCTV Camera<br />

ENG-Mount<br />

TV Adapter<br />

ENG-Mount<br />

TV<br />

Adapter*1*2<br />

0.45X, 0.6X<br />

Y-T TV Tube<br />

for C-Mount<br />

Adapter A<br />

Lamphouse HMX-3B<br />

Lamphouse HMX-4B<br />

with Built-in Back Mirror<br />

Lamphouse HMX<br />

ENG-<br />

Mount<br />

Zooming<br />

Adapter<br />

Relay<br />

Lens 1X I<br />

V-T Photo Adapter<br />

C-C Achromat Condenser<br />

C-Mount<br />

Zooming<br />

Adapter<br />

Zoom Lens<br />

Illumination Systems<br />

C-LA HMX Lamphouse Adapter<br />

HMX Connecting Adapter SB-X1<br />

(Bayonet to Screw Mount)<br />

HMX Connecting Adapter SB-X2<br />

(Screw to Bayonet Mount)<br />

C-FC Epi-Fl Collector Lens<br />

Quartz Epi-Fl Collector Lens<br />

Collector Lens/QH 100W<br />

Achromat Swing-out<br />

Condenser<br />

C-Mount TV<br />

Adapter<br />

Relay Lens<br />

1X I<br />

C-C Achromat/Aplanat<br />

Condenser<br />

C-Mount CCTV Camera<br />

C-Mount<br />

TV Adapter<br />

0.45X, 0.6X<br />

Condensers<br />

C-Mount<br />

TV<br />

Adapter A<br />

Y-TT Trinocular Tube "T" UW Y-TF Trinocular Tube "F" UW Y-TB Binocular Tube Y-TE Ergonomic<br />

Binocular Tube<br />

V-NA<br />

Motorized<br />

Sextuple Nosepiece<br />

LWD Achromat<br />

Condenser<br />

C-Mount<br />

TV Adapter<br />

VM2.5X<br />

CFI 10X<br />

with Diopter Adjustment<br />

C-Mount TV<br />

Adapter A<br />

C-Mount<br />

TV Adapter<br />

VM4X<br />

CFI 10XM<br />

Photom<strong>as</strong>k with<br />

Diopter Adjustment<br />

Eyepiece Tubes<br />

Y-FL Epi-Fl Attachment<br />

V-ND<br />

MG-DIC Intelligent<br />

Sextuple Nosepiece<br />

C-C Low Power<br />

Condenser<br />

C-Mount<br />

TV Adapter A<br />

CFI 12.5X<br />

with Diopter Adjustment<br />

Y-IDP Double Port<br />

Intermediate Tubes<br />

CCTV Camera Adapters<br />

*1: Use the dedicated 0.45X adapter for the double port sub-port.<br />

The 0.6X adapter cannot be used with the double port sub-port.<br />

*2: ENG-mount CCTV adapter 0.45x is a 38-bayonet mount type;<br />

other ENG-mount CCTV adapters are 48-bayonet mount types.<br />

C-N<br />

Sextuple<br />

Nosepiece<br />

CFI60 Objectives<br />

Darkfield Condenser (Oil)<br />

C-CEL Expander Lens<br />

Eyepieces<br />

CFI 15X<br />

with Diopter Adjustment<br />

Intermediate Tubes<br />

Nosepieces<br />

C-ND DIC<br />

Nosepiece<br />

Darkfield Condenser<br />

(Dry)<br />

3


CFI60 OBJECTIVES<br />

CFI Achromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

Correction for chromatic aberration in these objectives have been dramatically improved and are at the same level<br />

<strong>as</strong> the CFI Plan Achromat Series. These objectives were also corrected for spherical aberration and coma and<br />

image flatness across the 22mm field of view h<strong>as</strong> been dr<strong>as</strong>tically improved.<br />

The result: truly exceptional quality for this cl<strong>as</strong>s of objectives.<br />

The DL ph<strong>as</strong>e contr<strong>as</strong>t objectives in this series have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t<br />

with unstained specimens.<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

ø25<br />

ø17<br />

ø14.3<br />

ø8.1<br />

ø28.2<br />

ø25.5<br />

ø20<br />

ø12.2<br />

4.5<br />

ø27<br />

M25~0.75<br />

4.5<br />

4.5<br />

45˚<br />

4.2<br />

60.41<br />

D 20X /0.4<br />

Ph1 DL<br />

/1.2 WD 3.0<br />

M25~0.75<br />

ø27<br />

45˚<br />

6<br />

35˚<br />

3 4.5<br />

19.9 10<br />

30˚<br />

C1<br />

4 X /0.10<br />

/- WD 30<br />

ø25<br />

60.06<br />

2.3 5 36.5<br />

10<br />

45˚<br />

45˚<br />

10X /0.25<br />

/- WD 6.1<br />

ø10<br />

ø16<br />

ø25<br />

60.06<br />

4.1 6 36<br />

10<br />

45˚<br />

45˚<br />

20X /0.40<br />

/0.17 WD 3.8<br />

ø8<br />

ø14.3<br />

ø17<br />

ø25<br />

60.06<br />

4.5 10<br />

36<br />

60.41<br />

D 40X /0.55<br />

WD 2.1<br />

/0–2<br />

2 1.6 1.2 0.8 0.4 0<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

5 24.6 25<br />

CFI Achromat 4x<br />

CFI Achromat 10x<br />

CFI Achromat DL 10x<br />

CFI Achromat LWD 20x<br />

CFI Achromat LWD DL 20x<br />

CFI Achromat LWD DL 20x F<br />

CFI Achromat LWD 40x C<br />

CFI Achromat LWD DL 40x C<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

3.7 3 8<br />

34.5<br />

10 5<br />

45˚<br />

35˚<br />

40X /0.65<br />

WD 0.65<br />

/0.17<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

60.06<br />

CFI Achromat 40x<br />

CFI Achromat DL 40x<br />

5<br />

3 8<br />

34.5<br />

10<br />

4.1<br />

45˚<br />

35˚<br />

60X /0.80<br />

/0.17 WD 0.3<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

CFI Achromat 60x<br />

60.06<br />

5<br />

5 8<br />

34.5<br />

10<br />

2.2<br />

45˚<br />

20˚<br />

00X / 1.25 oil<br />

/0.17 WD 0.18<br />

ø5<br />

ø13<br />

ø16.6<br />

ø20<br />

ø25<br />

60.06<br />

CFI Achromat 100x Oil<br />

CFI Achromat DL 100x Oil<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Achromat 4x 0.10 30.0 50.0 27.50 72<br />

CFI Achromat 10x 0.25 6.1 20.0 4.40 85<br />

CFI Achromat DL 10x 0.25 6.1 20.0 4.40 85 ph1<br />

CFI Achromat LWD 20x 0.40 3.8 10.0 1.72 90<br />

CFI Achromat LWD DL 20x 0.40 3.8 10.0 1.72 90 ph1<br />

CFI Achromat 40x 0.65 0.65 5.0 0.65 130 Spring-loaded<br />

CFI Achromat DL 40x 0.65 0.65 5.0 0.65 130 Spring-loaded ph2<br />

CFI Achromat 60x 0.80 0.3 3.3 0.43 130 Spring-loaded<br />

CFI Achromat 100x Oil 1.25 0.18 2.0 0.27 130 Spring-loaded<br />

CFI Achromat DL 100x Oil 1.25 0.18 2.0 0.27 130 Spring-loaded ph3<br />

CFI Achromat LWD DL 20x F 0.40 3.0 10.0 1.72 90 Cover gl<strong>as</strong>s thickness 1.2mm ph1<br />

CFI Achromat LWD 40x C 0.55 2.7–1.7 5.0 0.91 195 Cover gl<strong>as</strong>s correction 0.2mm<br />

CFI Achromat LWD DL 40x C 0.55 2.7–1.7 5.0 0.91 195 Cover gl<strong>as</strong>s correction 0.2mm ph2<br />

4<br />

5


CFI60 OBJECTIVES<br />

CFI Plan Achromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

These objectives provide incredible image flatness over the entire 25mm field of view, with chromatic aberration<br />

corrected throughout the entire visible spectrum. These objectives are suitable not only for routine laboratory work<br />

but for photomicrography.<br />

The DL ph<strong>as</strong>e contr<strong>as</strong>t objectives in this series have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t<br />

with unstained specimens.<br />

10.7 46<br />

5<br />

ø30<br />

M25~0.75<br />

Plan UW<br />

1X /0.04<br />

/-WD 3.2<br />

60.06<br />

52.4 5<br />

5<br />

ø30<br />

M25~0.75<br />

Plan UW<br />

2X /0.06<br />

/-WD 7.5<br />

60.06<br />

19.9 10 4.5<br />

ø27<br />

M25~0.75<br />

Plan 4X/0.<br />

/-WD 3<br />

60.06<br />

5.5 3.5<br />

50.5<br />

5.3<br />

3<br />

45˚<br />

45˚<br />

ø30<br />

M25~0.75<br />

Plan<br />

40 X /0.65 N<br />

/ 0 WD 0.48<br />

ø7.5<br />

ø14<br />

ø18.8<br />

60<br />

CFI Plan Achromat 40x NCG<br />

ø27<br />

M25~0.75<br />

4.5 4.3 51.2<br />

5.3<br />

45˚<br />

30˚<br />

ø30<br />

M25~0.75<br />

Plan<br />

50 X /0.90 oil<br />

/- WD 0.40<br />

ø5.5<br />

ø14<br />

ø18.8<br />

60.06 (NCG)<br />

CFI Plan Achromat 50x Oil<br />

ø30<br />

M25~0.75<br />

2.4 37<br />

10 5<br />

ø31<br />

CFI Plan Achromat UW 1x<br />

45˚<br />

45˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

10X /0.25<br />

/-WD 10.5<br />

ø12<br />

ø19<br />

ø25<br />

60.06<br />

CFI Plan Achromat 10x<br />

CFI Plan Achromat DL 10x<br />

4.6 5 4.5<br />

34.5<br />

10 4.5<br />

ø20<br />

CFI Plan Achromat UW 2x<br />

45˚<br />

45˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

20 X /0.40<br />

/ 0.17 WD 1.3<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

60.06<br />

CFI Plan Achromat 20x<br />

CFI Plan Achromat DL 20x<br />

3.3 4 7.5<br />

34.5<br />

10 5<br />

ø25<br />

CFI Plan Achromat 4x<br />

45˚<br />

30˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

40 X /0.65<br />

/ 0.17<br />

ø6<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

WD0.57<br />

60.06<br />

CFI Plan Achromat 40x<br />

CFI Plan Achromat DL 40x<br />

2.2 4 9 44.5<br />

5<br />

45˚<br />

22.5˚<br />

Plan<br />

100 X /1.25<br />

/ 0.17 WD 0.17<br />

ø5.3<br />

ø13<br />

ø16.8<br />

ø20<br />

ø25<br />

60.06<br />

CFI Plan Achromat 100x Oil<br />

CFI Plan Achromat DL 100x Oil<br />

5<br />

51.2<br />

2.2 6.3<br />

2<br />

45˚<br />

20˚<br />

Plan<br />

100 X /0.90 N<br />

/ 0 WD 0.26<br />

ø5.5<br />

ø14<br />

ø18.8<br />

60<br />

CFI Plan Achromat 100x NCG<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Achromat UW 1x 0.04 3.2 200.0 171.88 180<br />

CFI Plan Achromat UW 2x 0.06 7.5 100.0 76.39 110<br />

CFI Plan Achromat 4x 0.10 30.0 50.0 27.50 65<br />

CFI Plan Achromat 10x 0.25 10.5 20.0 4.40 85<br />

CFI Plan Achromat DL 10x 0.25 10.5 20.0 4.40 85 ph1<br />

CFI Plan Achromat 20x 0.40 1.3 20.0 1.72 85<br />

CFI Plan Achromat DL 20x 0.40 1.3 20.0 1.72 85 ph1<br />

CFI Plan Achromat 40x 0.65 0.57 5.0 0.65 115 Spring-loaded<br />

CFI Plan Achromat DL 40x 0.65 0.57 5.0 0.65 115 Spring-loaded ph2<br />

CFI Plan Achromat 40x NCG 0.65 0.48 5.0 0.65 160 Spring-loaded No cover gr<strong>as</strong>s<br />

CFI Plan Achromat 50x Oil 0.90 0.4 4.0 0.52 160 Spring-loaded<br />

CFI Plan Achromat 100x Oil 1.25 0.17 3.3 0.52 160 Spring-loaded<br />

CFI Plan Achromat DL 100x Oil 1.25 0.17 3.3 0.52 160 Spring-loaded ph3<br />

CFI Plan Achromat 100x NCG 0.90 0.26 2.0 0.18 160 Spring-loaded No cover gr<strong>as</strong>s<br />

6<br />

7


CFI60 OBJECTIVES<br />

CFI Plan Fluor Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DLL)<br />

Featuring an extra-high transmission<br />

rate, especially in the ultraviolet<br />

wavelength, and flatness of field<br />

comparable to the CFI Plan Achromat<br />

series, these objectives are designed<br />

for fluorescence observation and<br />

photomicrography. Because of this<br />

improvement in quality, these<br />

objectives can function <strong>as</strong> multipurpose<br />

objectives for brightfield,<br />

fluorescence, polarizing, and DIC<br />

observations.<br />

The DLL (low contr<strong>as</strong>t) ph<strong>as</strong>e<br />

objectives for this series can also be<br />

used <strong>as</strong> universal objectives for<br />

ph<strong>as</strong>e contr<strong>as</strong>t, fluorescence, DIC,<br />

and brightfield techniques.<br />

5.3<br />

42.8<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

4X / 0.13<br />

/ - WD 17.1<br />

ø20<br />

CFI Plan Fluor 4x<br />

45˚<br />

5.3<br />

43.9<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

10X / 0.30<br />

DIC L@<br />

/0.17 WD 16.0<br />

ø18<br />

CFI Plan Fluor 10x<br />

CFI Plan Fluor DLL 10x<br />

45˚<br />

1.7<br />

5.3<br />

10.8 11<br />

32<br />

3.9<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

60X / 0.85<br />

DIC M<br />

/0.11-0.23 WD 0.30<br />

11 14 17 20 23<br />

ø8.5<br />

ø18<br />

ø22<br />

ø33<br />

30˚<br />

30˚<br />

5.3<br />

3.8 4.5<br />

51.5<br />

ø30<br />

Plan Fluor<br />

100X/1.30 oil<br />

DIC H<br />

/0.17 WD 0.20<br />

ø5.8<br />

ø17<br />

ø21<br />

20˚<br />

45˚<br />

6.2<br />

2.6<br />

5.3<br />

34<br />

2.9 6.5 7.5<br />

17˚<br />

ø33.4<br />

ø32<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

100X/0.5-1.3 oil<br />

/0.17 WD 0.2<br />

1.3 0.7<br />

ø5.3<br />

ø19.8<br />

ø23.6<br />

ø32<br />

C2.5<br />

8˚<br />

ø30<br />

M25~0.75<br />

ø30<br />

M25~0.75<br />

ø33.5<br />

ø30<br />

CFI Plan Fluor 60x C<br />

CFI Plan Fluor 100x Oil<br />

CFI Plan Fluor DLL 100x Oil<br />

CFI Plan Fluor 100x Oil with<br />

iris diaphragm<br />

5.3<br />

54<br />

Plan Fluor<br />

20X / 0.50<br />

DIC M<br />

/0.17 WD 2.1<br />

45˚<br />

5.3<br />

57.2<br />

5.5<br />

Plan Fluor<br />

40X / 0.75<br />

DIC M<br />

/0.17 WD 0.72<br />

40<br />

12 5.3<br />

45˚<br />

60.41<br />

Plan Fluor<br />

4X / 0.13<br />

PhL DL<br />

/1.2 WD 16.4<br />

45˚<br />

5<br />

42.8<br />

5.3<br />

M25~0.75<br />

Plan Fluor<br />

40X / 1.30 oil<br />

DIC H<br />

/0.17 WD 0.2<br />

CFI Plan Fluor Series for Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

These objectives have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t with tissue culture<br />

specimens. These objectives are designed for use on inverted microscopes and therefore their markings are<br />

upside-down for e<strong>as</strong>y reading.<br />

1.2<br />

45˚<br />

3.8<br />

2.7<br />

ø12<br />

ø17<br />

CFI Plan Fluor 20x<br />

CFI Plan Fluor DLL 20x<br />

2<br />

ø10<br />

45˚<br />

CFI Plan Fluor 40x<br />

CFI Plan Fluor DLL 40x<br />

4<br />

3.7<br />

23˚<br />

ø8<br />

ø22<br />

ø25.8<br />

CFI Plan Fluor 40x Oil<br />

60.41<br />

Plan Fluor<br />

10X / 0.30<br />

Ph1 DL<br />

/1.2 WD 15.2<br />

45˚<br />

6<br />

44<br />

5.3<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor 4x 0.13 17.1 50.0 16.27 110<br />

CFI Plan Fluor 10x 0.30 16.0 20.0 3.06 120<br />

CFI Plan Fluor DLL 10x 0.30 16.0 20.0 3.06 120 ph1<br />

CFI Plan Fluor 20x 0.50 2.1 10.0 1.10 175<br />

CFI Plan Fluor DLL 20x 0.50 2.1 10.0 1.10 175 ph1<br />

CFI Plan Fluor 40x 0.75 0.72 5.0 0.49 210 Spring-loaded<br />

CFI Plan Fluor DLL 40x 0.75 0.72 5.0 0.49 210 Spring-loaded ph2<br />

CFI Plan Fluor 40x Oil 1.30 0.2 5.0 0.25 230 Spring-loaded Stopper<br />

CFI Plan Fluor 60x C 0.85 0.3 3.3 0.38 265 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Fluor 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper<br />

CFI Plan Fluor DLL 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper ph3<br />

CFI Plan Fluor 100x Oil with iris diaphragm 0.5–1.3 0.2 2.0 0.25 285 Spring-loaded With iris diaphragm<br />

M25~0.75<br />

M25~0.75<br />

ø30<br />

ø30<br />

CFI Plan Fluor DL 4x<br />

CFI Plan Fluor DL 10x<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor DL 4x 0.13 16.4 50.0 16.27 105 Cover gl<strong>as</strong>s thickness 1.2mm phL<br />

CFI Plan Fluor DL 10x 0.30 15.2 20.0 3.06 120 Cover gl<strong>as</strong>s thickness 1.2mm ph1<br />

8<br />

9


CFI60 OBJECTIVES<br />

CFI Plan Fluor ELWD Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM/DLL)<br />

Offering superb flatness of field, high UV transmission rates, and high Numerical Apertures with extra long working distances, these objectives are<br />

well suited for fluorescence observations, especially with inverted microscopes. Because of their superior optical design, CFI Plan Fluor ELWD DM<br />

objectives can be used universally for all other observation techniques, including brightfield, fluorescence, ph<strong>as</strong>e contr<strong>as</strong>t, and Nomarski DIC.<br />

The DM ph<strong>as</strong>e contr<strong>as</strong>t objectives have higher contr<strong>as</strong>t to enhance the image of very thin, highly detailed specimens with low ph<strong>as</strong>e gradients.<br />

The DLL objectives have less contr<strong>as</strong>t for thicker, more contr<strong>as</strong>ty specimens.<br />

1.2<br />

Standard<br />

thickness<br />

ø32.5<br />

ø28.7<br />

ø25.5<br />

ø16.4<br />

ø32.5<br />

ø29<br />

ø27.5<br />

ø13.3<br />

ø32.5<br />

ø26.3<br />

ø10<br />

CFI Plan Apochromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM)<br />

These objectives feature longer working distances with high Numerical Apertures and is designed to correct all<br />

optical aberrations throughout the visible spectrum from violet to red from center to edges across the entire 25mm<br />

field of view. Superior image flatness and color reproduction, plus resolving power at the theoretical limit of today's<br />

optical technology are also featured.<br />

The DM ph<strong>as</strong>e contr<strong>as</strong>t Plan Apochromats have higher contr<strong>as</strong>t to enhance images of very thin, highly detailed<br />

specimens with low ph<strong>as</strong>e gradients.<br />

60.41<br />

Plan Fluor<br />

LWD 20X/0.45<br />

/ 0-2 WD 7.4<br />

25˚<br />

5˚<br />

22.2 1.8<br />

1.8<br />

60.41<br />

Plan Fluor<br />

LWD 40X/0.60<br />

/0-2 WD 3.7 - 2.7<br />

20˚<br />

5<br />

26.5 2.5<br />

2.5<br />

60.41<br />

Plan Fluor<br />

WD 60X/0.70<br />

0.5-1.5 WD 2.1-1.5<br />

22.5<br />

7.5˚<br />

33<br />

5.3<br />

ø30<br />

M25~0.75<br />

5.3<br />

ø30<br />

M25~0.75<br />

5.3<br />

ø30<br />

M25~0.75<br />

2 1.6 1.2 0.8 0.4 0<br />

ø29<br />

ø32<br />

ø34<br />

7˚<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 20x C<br />

CFI Plan Fluor ELWD DM 20x C<br />

2 1.6 1.2 0.8 0.4 0<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

7˚<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 40x C<br />

CFI Plan Fluor ELWD DM 40x C<br />

1.5 1.2 1 0.8 0.5<br />

M25~0.75<br />

ø29<br />

ø33<br />

ø34<br />

9˚<br />

6<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 60x C<br />

CFI Plan Fluor ELWD DLL 60x C<br />

51.4<br />

45˚<br />

Plan Apo<br />

2X / 0.1<br />

/ - WD 8.5<br />

ø19<br />

WD=8.5<br />

CG=0.17<br />

60.06<br />

44.2<br />

30<br />

Plan Apo<br />

4X / 0.2<br />

/ - WD 15.7<br />

ø18<br />

WD=15.7<br />

CG=0.17<br />

60.06<br />

55.9<br />

45˚<br />

Plan Apo<br />

10X / 0.45<br />

DIC L<br />

/0.17 WD 4.0<br />

ø15<br />

WD=4.0<br />

CG=0.17<br />

60.06<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor ELWD 20x C 0.45 8.1–7.0 10.0 1.36 195 Cover gl<strong>as</strong>s correction 0–2mm<br />

CFI Plan Fluor ELWD DM 20x C 0.45 8.1–7.0 10.0 1.36 195 Cover gl<strong>as</strong>s correction 0–2mm ph1<br />

CFI Plan Fluor ELWD 40x C 0.60 3.7–2.7 5.0 0.76 195 Cover gl<strong>as</strong>s correction 0–2mm<br />

CFI Plan Fluor ELWD DM 40x C 0.60 3.7–2.7 5.0 0.76 195 Cover gl<strong>as</strong>s correction 0–2mm ph2<br />

CFI Plan Fluor ELWD 60x C 0.70 2.1–1.5 3.3 0.56 210 Cover gl<strong>as</strong>s correction 0.5–1.5mm<br />

CFI Plan Fluor ELWD DLL 60x C 0.70 2.1–1.5 3.3 0.56 210 Cover gl<strong>as</strong>s correction 0.5–1.5mm ph2<br />

CFI Plan Apochromat 2x<br />

CFI Plan Apochromat 4x<br />

CFI Plan Apochromat 10x<br />

10<br />

Multi-Immersion Objective for Brightfield<br />

This multi-purpose immersion objective h<strong>as</strong> a higher numerical aperture and<br />

superior contr<strong>as</strong>t. The use of immersion media helps eliminate surface<br />

reflections and provides an image with higher contr<strong>as</strong>t. It is an excellent<br />

objective for fluorescence, brightfield, and DIC observation techniques.<br />

This unique objective h<strong>as</strong> a correction collar that allows it to be used with<br />

immersion oil, glycerin, and water (with and without a cover gl<strong>as</strong>s).<br />

Objective N.A. W.D. Focal length Physical depth Weight Remarks<br />

(magnification) (mm) (mm) of focus (µm) (g)<br />

CFI Plan Fluor 20x MI 0.75 0.35–0.33 10.0 0.49 300<br />

Multi-immersion<br />

Oil-glycerine-water<br />

10.4 19 12.5 14 5.3<br />

3.7<br />

Oil G<br />

ø36<br />

ø34.5<br />

ø30.6<br />

M25~0.75<br />

Plan Fluor<br />

20X / 0.75 Mlmm<br />

/ - WD 0.35<br />

ø8<br />

ø28<br />

ø33<br />

0.17 W<br />

0<br />

CFI Plan Fluor 20x MI<br />

40˚<br />

8˚<br />

3˚<br />

30˚<br />

5.3<br />

12<br />

5.9 2.5 38.5<br />

45˚<br />

30˚<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

20X / 0.75<br />

DIC M<br />

/0.17 WD 1.0<br />

ø13.5<br />

ø22<br />

ø26<br />

WD=1.0<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 20x<br />

CFI Plan Apochromat DM 20x<br />

1.7<br />

4.2 10.8 11<br />

32 5.3<br />

30˚<br />

30˚<br />

3˚<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

40X / 0.95<br />

DIC M<br />

/0.11-0.23 WD 0.14<br />

11 14 17 20 23<br />

ø7<br />

ø18<br />

ø22<br />

ø33<br />

WD=0.14<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 40x C<br />

CFI Plan Apochromat DM 40x C<br />

5<br />

12<br />

4.7 4.5 38.5<br />

45˚<br />

30˚<br />

5˚<br />

ø32<br />

ø30<br />

ø25<br />

Plan Apo<br />

40X / 1.0 oil<br />

DIC H<br />

/0.17 WD 0.16<br />

ø8<br />

ø18.8<br />

ø22.8<br />

WD=0.16 (oil)<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 40x Oil<br />

CFI Plan Apochromat DM 40x Oil<br />

11


CFI60 OBJECTIVES<br />

1.7<br />

5.3<br />

32<br />

11<br />

10.8<br />

4.2<br />

30˚<br />

30˚<br />

3˚<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /0.95<br />

DIC M<br />

/ 0.11-0.23 WD 0.15<br />

11 14 17 20 23<br />

ø7<br />

ø18<br />

ø22<br />

ø33<br />

WD=0.15<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 60x C<br />

CFI Plan Apochromat DM 60x C<br />

ø30<br />

M25~0.75<br />

CFI Plan Apochromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM)<br />

3.7 4<br />

40<br />

12 5.3<br />

45˚<br />

22.5˚<br />

8˚<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /1.40 oil<br />

DIC H<br />

/ 0.17 WD 0.21<br />

ø7.2<br />

ø22<br />

ø25.8<br />

CG=0.17 WD=0.21 (oil)<br />

60.06<br />

CFI Plan Apochromat 60x Oil<br />

CFI Plan Apochromat DM 60x Oil<br />

ø30<br />

M25~0.75<br />

59.7 5.3<br />

23.5<br />

11<br />

11.9<br />

10.4<br />

2.9<br />

30˚<br />

7˚<br />

5˚<br />

30˚<br />

ø36.5<br />

ø35.2<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /1.20 WI<br />

/ 0.15-0.18 WD 0.22<br />

15 16 17 18<br />

ø7.5<br />

ø29<br />

ø33.4<br />

CFI Plan Apochromat 60x WI<br />

CFI S Fluor Series<br />

These objectives ensure a high transmission rate of ultraviolet wavelengths down to 340 nm for fluorochromes like<br />

indo-1, fura-2, and fluor-3. Also, these objectives have improved signal-to-noise ratios (S/N) for short wavelengths and<br />

have high N.A., making the fluorescence images they produce significantly sharper and brighter.<br />

64<br />

5.3<br />

12<br />

38.5<br />

8.2<br />

ø32<br />

ø30<br />

M25~0.75<br />

S Fluor<br />

10 X / 0.50<br />

/ 0.17 WD 0.12<br />

ø8<br />

ø19<br />

ø24<br />

1.2<br />

64.2<br />

5.3<br />

5.9 41<br />

12<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

S Fluor<br />

20 X / 0.75<br />

/ 0.17 WD 1.0<br />

ø9<br />

ø22<br />

ø25<br />

1<br />

5<br />

27<br />

3.1 8.5 10.5 10.5<br />

ø34.5<br />

ø33<br />

ø30<br />

M25~0.75<br />

Fluor 40 X / 0.9<br />

/ 0.11-0.23 WD 0.3<br />

11 14 17 20 23<br />

ø7.5<br />

ø18<br />

ø26<br />

ø33<br />

CFI S Fluor 10x<br />

CFI S Fluor 20x<br />

CFI S Fluor 40x C<br />

5.3<br />

59.8<br />

51.5<br />

Plan Apo<br />

100 X /1.40 oil<br />

DIC H<br />

/ 0.17 WD 0.13<br />

60.06<br />

59.8 5.3<br />

51.5<br />

Plan Apo<br />

00X /1.40 oilN<br />

/ 0 WD 0.17<br />

60<br />

5<br />

12<br />

ø32<br />

ø30<br />

M25~0.75<br />

5<br />

ø32<br />

ø30<br />

M25~0.75<br />

4.5<br />

3.8<br />

20˚<br />

C2<br />

ø5.8<br />

ø17<br />

ø21<br />

WD=0.13<br />

4.5<br />

3.8<br />

C2<br />

20˚<br />

ø5.8<br />

ø17<br />

ø21<br />

WD=0.17<br />

37<br />

S Fluor<br />

40 X / 1.30<br />

/ 0.17 WD 0.22<br />

Oil<br />

64.7<br />

32<br />

7.5<br />

7.5<br />

S Fluor<br />

100 X /0.5-1.3 oil<br />

/ 0.17 WD 0.2<br />

1.3 0.7<br />

CFI Plan Apochromat 100x Oil<br />

CFI Plan Apochromat DM 100x Oil<br />

CFI Plan Apochromat 100x NCG Oil<br />

6.5<br />

9.8<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Apochromat 2x 0.10 8.5 100.0 27.50 180<br />

CFI Plan Apochromat 4x 0.20 15.7 50.0 6.88 180<br />

CFI Plan Apochromat 10x 0.45 4.0 20.0 1.36 220<br />

CFI Plan Apochromat 20x 0.75 1.0 10.0 0.49 240 Spring-loaded<br />

CFI Plan Apochromat DM 20x 0.75 1.0 10.0 0.49 240 Spring-loaded ph2<br />

CFI Plan Apochromat 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Apochromat DM 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />

CFI Plan Apochromat 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Apochromat DM 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />

CFI Plan Apochromat 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 60x WI 1.20 0.22 3.3 0.25 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.15–0.18mm<br />

Water immersion<br />

CFI Plan Apochromat 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 100x NCG Oil 1.40 0.17 2.0 0.21 245 Spring-loaded Stopper No cover gl<strong>as</strong>s<br />

4.2<br />

ø8.3<br />

ø20<br />

ø23.8<br />

CFI S Fluor 40x Oil<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI S Fluor 10x 0.50 1.2 10.0 1.10 275 Spring-loaded<br />

CFI S Fluor 20x 0.75 1.0 10.0 0.49 275 Spring-loaded<br />

CFI S Fluor 40x C 0.90 0.3 5.0 0.34 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI S Fluor 40x Oil 1.30 0.22 5.0 0.25 275 Spring-loaded<br />

CFI S Fluor 100x Oil 1.30 0.2 2.0 0.25 285 Spring-loaded<br />

2.9<br />

ø6<br />

ø17<br />

ø24<br />

ø29.5<br />

CFI S Fluor 100x Oil<br />

12<br />

13


CFI60 OBJECTIVES<br />

Water Dipping Series CFI HMC ® Series for Hoffmann Modulation Contr<strong>as</strong>t ®<br />

These objectives (no cover gl<strong>as</strong>s) are designed with a narrow top and a 2mm working distance to allow<br />

microelectrodes to be inserted into the specimen at 45°. They use ceramic and gl<strong>as</strong>s nose cones to isolate them<br />

thermally and electronically. Since they are FLUOR lenses, they are designed for fluorescence and have very high<br />

transmission in the UV and IR wavelengths with a high signal-to-noise ratio for superior images.<br />

ø29<br />

M25~0.75<br />

ø29<br />

M25~0.75<br />

ø29<br />

M25~0.75<br />

These objectives have been completely redesigned by <strong>Nikon</strong>, allowing the contr<strong>as</strong>t direction to be changed using<br />

a modulator inside the objective. That direction, once set, is maintained over the entire magnification range from<br />

10X to 40X.<br />

Note: Hoffman Modulation Contr<strong>as</strong>t and HMC are registered trademarks of Modulation Optics Inc.<br />

ø25<br />

ø13.3<br />

ø10<br />

ø25<br />

ø16.5<br />

ø15<br />

ø8<br />

ø33.3<br />

ø32<br />

ø28.8<br />

ø25.5<br />

ø20<br />

ø12<br />

5<br />

58.5<br />

32.7<br />

1.5 12 3.8 8.5<br />

55˚<br />

45˚<br />

Fluor<br />

10X / 0.30 W<br />

DIC L<br />

/ 0 WD 2.0<br />

ø3.5<br />

ø5<br />

ø20.5<br />

ø24<br />

ø26<br />

48˚<br />

2 (Water dipping)<br />

60.5<br />

5<br />

58.5<br />

32.7<br />

4.5 5 5 11.3<br />

50˚<br />

45˚<br />

Fluor<br />

40X / 0.80 W<br />

DIC M<br />

/ 0 WD 2.0<br />

ø4<br />

ø11.5<br />

ø19<br />

ø23<br />

ø25.5<br />

45˚<br />

2 (Water dipping)<br />

60.5<br />

5<br />

58.5<br />

32.7<br />

1 5.5 8 11.3<br />

40˚<br />

30˚<br />

Fluor<br />

60X / 1.00 W<br />

DIC H<br />

/ 0 WD 2.0<br />

ø5.5<br />

ø19.2<br />

ø23<br />

ø25.5<br />

33.7˚<br />

2 (Water dipping)<br />

60.5<br />

60.41<br />

45˚<br />

45˚<br />

10X / 0.25<br />

/ 1.2 WD 5.2<br />

MC1 HMC<br />

M25~0.75<br />

ø27<br />

ø27.8<br />

4.5 10 13<br />

28.5 4.5 2.5<br />

60.41<br />

45˚<br />

45˚<br />

D 20X / 0.4<br />

/ 1.2 WD 3.0<br />

MC2 HMC<br />

M25~0.75<br />

ø27<br />

ø27.8<br />

4.8<br />

10 13<br />

28.5<br />

4.5<br />

60.41<br />

WD 40X / 0.55<br />

/0- 2 WD 2.7-1.7<br />

2<br />

MC3 HMC<br />

1.6 1.2 0.8 0.4<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

0<br />

35˚<br />

1<br />

5 13 11.5 8 19 5.6<br />

CFI Fluor 10x W<br />

CFI Fluor 40x W<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI Fluor 10x W 0.30 2.0 20.0 4.06 210 Water dipping<br />

CFI Fluor 40x W 0.80 2.0 5.0 0.57 210 Water dipping<br />

CFI Fluor 60x W 1.0 2.0 3.3 0.37 210 Water dipping<br />

CFI Fluor 60x W<br />

CFI HMC 10x<br />

2nd Objective Lens Unit<br />

CFI HMC 20x F<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI HMC 10x 0.25 5.2 20.0 4.40 130 Cover gl<strong>as</strong>s thickness 1.2mm<br />

CFI HMC 20x F 0.40 3.0 10.0 1.72 130 Cover gl<strong>as</strong>s thickness 1.2mm<br />

CFI HMC LWD 40x C 0.55 2.7–1.7 5.0 0.91 210 Cover gl<strong>as</strong>s correction0–2mm<br />

This unit is attached to infinity objectives when neither a<br />

binocular or trinocular eyepiece tube is used.<br />

• Infinity Tube Lens Unit for CFI objectives (chromatic aberrationfree<br />

infinity corrected objectives).<br />

• Focusing distance: 200mm (7.87 in.)<br />

• To obtain the optimal objective performance, keep the distance<br />

between the tube lens and the objective’s shoulder within<br />

100–200 mm (3.84–7.87 in.).<br />

28<br />

22.5<br />

M38~0.5<br />

5<br />

ø36f7 -0.025<br />

-0.050<br />

ø33<br />

CFI HMC LWD 40x C<br />

Approx. 70~170 148<br />

Image plane<br />

Objective's shoulder<br />

Plan Fluor<br />

100X / 1.30 oil<br />

DIC H<br />

/ 0.17 WD 0.20<br />

14<br />

2nd Objective Lens Unit<br />

15


CFI60 OBJECTIVES<br />

Markings on CFI60 Objectives<br />

Condensers<br />

2.5 58<br />

21<br />

ø27<br />

ø8<br />

30˚<br />

ø50<br />

14.5 6<br />

7.5<br />

(1) Magnification and Color Code<br />

A color coded ring on the barrel identifies<br />

the magnification of the objective:<br />

(2) Numerical Aperture (N.A.)<br />

N.A. is the most important factor in defining<br />

the performance characteristics of an objective.<br />

N. A.= n sin <br />

n: the refractive index of the media at d-line (587nm)<br />

For dry objective n=1.000 (air)<br />

For oil objective n=1.515 (oil)<br />

For water objective n= 1.333 (water)<br />

:Half angle of incident rays to the top lens of the objective<br />

The higher N.A., the higher resolving power.<br />

When the resolving power is defined <strong>as</strong> the power to<br />

recognize the two points,<br />

R=<br />

or<br />

(1) Magnification (2) Numerical Aperture<br />

(6) Application Markings<br />

<br />

N.A.<br />

R=<br />

<br />

N.A. Obj. +N.A. Cond.<br />

The higher N.A. the brighter image we take.<br />

2<br />

Brightness: B <br />

N.A.<br />

Total Magnification <br />

The higher N.A., the shallower the depth of focus (DOF).<br />

DOF = N.A. 2<br />

(1) Color Code<br />

(7) Immersion Oil—cleaning<br />

Mag. 1X 2X 4X 10X 20X 40X 50X 60X 100X<br />

Color code Black Gray Red Yellow Green<br />

Light<br />

Blue<br />

Light<br />

Blue<br />

Cobalt<br />

Blue<br />

White<br />

(3) Working Distance<br />

Working distance (W.D.) defines the distance between<br />

the top lens of the objective and the surface of the<br />

cover gl<strong>as</strong>s.<br />

CFI60 objectives can offer longer working distance with<br />

high numerical aperture.<br />

(3) Working Distance<br />

<strong>Nikon</strong> offers a wide variety of CFI objectives. To <strong>as</strong>sist the user they are clearly marked with information<br />

on the objective barrel such <strong>as</strong>: which DIC module or Ph<strong>as</strong>e Ring to use.<br />

n = 1.515<br />

Oil<br />

n = 1.000<br />

Dry<br />

Objective lens<br />

<br />

Cover Gl<strong>as</strong>s<br />

Slide Gl<strong>as</strong>s<br />

(4) Correction Ring<br />

Dry objectives with high Numerical Aperture are<br />

susceptible to spherical and other aberrations which<br />

can impair resolution and contr<strong>as</strong>t when used with a<br />

cover gl<strong>as</strong>s whose thickness differs from the specified<br />

value. A 1 1/2 cover gl<strong>as</strong>s (0.17mm thick) should be used<br />

<strong>as</strong> standard, however not all 11/2 cover gl<strong>as</strong>ses are<br />

exactly 0.17mm and many specimens have media<br />

between them and the cover gl<strong>as</strong>s. The correction ring<br />

is used to adjust for these subtle differences to ensure<br />

the optimum objective performance.<br />

How to use the correction ring<br />

Position the ring at 0.17. The thickness of the<br />

standard cover gl<strong>as</strong>s is 0.17mm.<br />

Focus the lens on a small artifact in the specimen.<br />

Rotate the ring very slightly and focus the lens again<br />

to check if the image h<strong>as</strong> improved or degraded.<br />

Repeat the above step to determine if the image is<br />

improving or degrading in the direction you are<br />

turning the ring.<br />

If the image h<strong>as</strong> degraded, follow the same<br />

procedure in the opposite direction to find the<br />

position offering optimum resolving power and<br />

contr<strong>as</strong>t.<br />

(5) Cover Gl<strong>as</strong>s<br />

For optimum performance, the thickness of the cover<br />

gl<strong>as</strong>s should be 0.17mm. For example, at N.A.=0.95, a<br />

0.01mm difference in thickness reduces image<br />

formation by 45% from the ideal image.<br />

N.A.<br />

0.3<br />

0.45<br />

0.7<br />

0.85<br />

0.95<br />

Difference in cover gl<strong>as</strong>s thickness<br />

0.01mm<br />

0.02mm<br />

100%<br />

100<br />

98<br />

81<br />

45<br />

(4) Correction Ring<br />

(5) Cover Gl<strong>as</strong>s<br />

100%<br />

100<br />

92<br />

43<br />

29<br />

(6) Application Markings<br />

DIC: for Differential Interference Contr<strong>as</strong>t<br />

DM: Ph<strong>as</strong>e contr<strong>as</strong>t, Dark contr<strong>as</strong>t middle type<br />

DL: Ph<strong>as</strong>e contr<strong>as</strong>t, Dark contr<strong>as</strong>t light type<br />

DLL: Ph<strong>as</strong>e contr<strong>as</strong>t, Lower contr<strong>as</strong>t type<br />

(7) Immersion Oil—cleaning<br />

After using immersion oil, gently blot the lens dry with<br />

lens tissue. Then slightly moisten a piece of lens tissue<br />

with petroleum benzene (Naphtha) and clean off all<br />

traces of the oil from the immersion objective. Cleaning<br />

is essential for water immersion objectives <strong>as</strong> well; after<br />

use, wipe the water off the top lens.<br />

Type N.A. Object distance (mm) Magnification<br />

C-C Abbe Condenser, Dry Type 0.9 1.9 4–100x<br />

C-C Achromat Condenser 0.8 4.2 4–100x<br />

Achromat Swing-out Condenser 0.9/0.22 1.8 2–100x<br />

C-C Achromat /Aplanat Condenser 1.40 1.6 10–100x<br />

LWD Achromat Condenser 0.65 10.2 4–40x<br />

C-C Low Power Condenser 0.13 10.2 1–4x<br />

Dark Field Condenser, Oil 1.2–1.43 1.5 20–100x<br />

Dark Field Condenser, Dry 0.8–0.95 4.0 20–40x<br />

16 17<br />

1.0<br />

(Slidgl<strong>as</strong>s thickness)<br />

55<br />

10<br />

R40<br />

ø55<br />

ø43<br />

ø40<br />

ø54<br />

ø59<br />

0.7<br />

8 54.9<br />

55.6<br />

C-C Abbe Condenser, Dry Type<br />

8 55.5 1<br />

(Slidgl<strong>as</strong>s thickness)<br />

0.6<br />

(Oil)<br />

54.4 -0.2<br />

0<br />

70˚<br />

ø54<br />

Achr-ADl N.A=1.4 JAPAN<br />

1.4 1.2 1.0 0.8 0.6 0.4 0.2<br />

ø40<br />

ø62<br />

C-C Achromat /Aplanat Condenser<br />

55 0.5<br />

14 9.5 (Oil)<br />

20<br />

70˚<br />

ø39<br />

ø34.5<br />

Dark Field Condenser<br />

Oil 1.43-1.20<br />

JAPAN<br />

ø40<br />

ø56<br />

Dark Field Condenser, Oil<br />

R40<br />

ø55<br />

ø36.8<br />

ø40<br />

ø54<br />

ø58<br />

2.0<br />

8 54.5<br />

56.5<br />

C-C Achromat Condenser<br />

1<br />

55.6<br />

54<br />

8<br />

(Slidgl<strong>as</strong>s thickness)<br />

1.5<br />

ø59<br />

ø54.5<br />

ø42<br />

ø36.8<br />

ø22<br />

ø40<br />

9<br />

12<br />

24.5<br />

LWD Achromat Condenser<br />

70˚<br />

20.6<br />

ø35.5<br />

Dark Field Condenser<br />

Dry 0.95-0.80<br />

JAPAN<br />

ø40<br />

ø56<br />

Dark Field Condenser, Dry<br />

29.8<br />

4.5˚<br />

8.6<br />

8<br />

Achr 0.90 JAPAN<br />

0.8 0.6 0.4 0.2<br />

54.8<br />

63.4<br />

ø60<br />

ø10<br />

34.5<br />

19<br />

13<br />

11.5<br />

4.5˚<br />

R40<br />

ø40<br />

Achromat Swing-out Condenser<br />

R40<br />

ø55<br />

ø38<br />

ø40<br />

ø54<br />

ø58<br />

8 58.7<br />

8.3<br />

67<br />

C-C Low Power Condenser<br />

C-CEL<br />

ø30<br />

11.5<br />

14.9<br />

8<br />

C-CEL Expander Lens (for darkfield)<br />

55<br />

70˚


Illumination Systems<br />

139<br />

168.5<br />

139<br />

50<br />

12 24.5 13.5<br />

90˚<br />

76<br />

3.5<br />

28.5<br />

15<br />

76<br />

7<br />

4<br />

4.6<br />

30 8<br />

Eyepiece Tubes<br />

(Center of lamp)<br />

30<br />

6.6<br />

67.8<br />

20.5<br />

37.8<br />

i35.5‘39.5j<br />

7<br />

ø57<br />

41.5<br />

ø67<br />

ø51<br />

ø71<br />

M50~0.75<br />

ø71<br />

ø61<br />

ø55<br />

105<br />

24<br />

61 (Center of lamp)<br />

105<br />

24<br />

61<br />

(Center of lamp)<br />

20.5<br />

3<br />

4<br />

171<br />

1 170<br />

80<br />

80.5<br />

Lamphouse HMX-3B<br />

171<br />

1 170<br />

80<br />

80.5<br />

Lamphouse HMX-4B, built-in back mirror<br />

(Datum clamp face)<br />

(Datum clamp face)<br />

C-LA HMX Lamphouse Adapter<br />

(Datum clamp face)<br />

(Datum clamp face)<br />

HMX Connecting Adapter SB-X1<br />

(Bayonet to Screw)<br />

M50~0.75-6H<br />

Sectional View<br />

HMX Connecting Adapter SB-X2<br />

(Screw to Bayonet)<br />

ø42<br />

4<br />

60<br />

80<br />

64<br />

77 69.5<br />

100<br />

70<br />

105 (Min. distance)<br />

50<br />

64<br />

(Tilting section)<br />

98<br />

100<br />

110<br />

Approx. 111<br />

90.5<br />

8 63<br />

R32<br />

R40<br />

Y-TB Binocular Tube<br />

8˚ (Min. angle)<br />

ø51.3<br />

5<br />

70<br />

50<br />

50.5 77<br />

Y-TE Ergonomic Binocular Tube<br />

120<br />

2<br />

ø56<br />

47<br />

68<br />

80<br />

109<br />

67.8<br />

137.3<br />

99.5<br />

81.5<br />

52.5<br />

40<br />

70 8.5<br />

26<br />

102<br />

20<br />

138.5<br />

76.5<br />

6<br />

136<br />

34<br />

2<br />

51<br />

10<br />

148<br />

Lamphouse HMX<br />

Mercury Lamp Socket S 100W for HMX-3B<br />

27.1<br />

135.9<br />

50<br />

ø50<br />

ø52<br />

16.5<br />

ø58<br />

ø52<br />

172<br />

10.3 0.6<br />

24 5<br />

(Center of pin)<br />

(Center of filament)<br />

218.5<br />

151.5<br />

ø59<br />

16.5<br />

3<br />

Halogen Lamp Socket 100W/HMX<br />

58.5<br />

100<br />

73.7<br />

38.5<br />

7.5<br />

12<br />

36 11<br />

3<br />

36.5<br />

12.5<br />

66.5<br />

102.5<br />

i239j<br />

76.5<br />

18<br />

ø45<br />

1.1<br />

ø33<br />

Center <br />

of <br />

lamp<br />

3 22<br />

ø3<br />

6<br />

C-FC Epi-Fl Collector Lens<br />

ø45<br />

ø36<br />

Center <br />

of <br />

lamp<br />

3 21<br />

Quartz Epi-Fl Collector Lens<br />

ø45<br />

Center of<br />

lamp<br />

3 22<br />

Collector Lens/QH100W<br />

Y-TF Trinocular Tube “F” UW<br />

Y-TT Trinocular Tube “T” UW<br />

Y-TB Binocular Tube<br />

F.O.V. 22mm<br />

Y-TE Ergonomic Binocular Tube F.O.V. 22mm with tilting angle of 8° to 32° and telescopic mechanism of ±15mm movement<br />

Y-TF Trinocular Tube “F” UW Two-way: 100 : 0 or 0 : 100 (observation : photo) F.O.V. 22mm or 25mm with eyepiece reticule orientation adjustment mechanism<br />

Y-TT Trinocular Tube “T” UW Three-way: 100 : 0, 20 : 80, or 0 : 100 (observation : photo) F.O.V. 22mm or 25mm with eyepiece reticule orientation adjustment mechanism<br />

19


Intermediate Tubes<br />

Nosepieces<br />

22.5<br />

22.5<br />

(Top View)<br />

50.5<br />

285.5<br />

175<br />

V-ND JAPAN<br />

V-N JAPAN<br />

264<br />

248<br />

80<br />

100<br />

100<br />

80<br />

126.5<br />

13.5<br />

57.5<br />

22<br />

50<br />

123.2<br />

50<br />

123.2<br />

3<br />

(Right-side View)<br />

ø52<br />

6<br />

1<br />

2<br />

53<br />

48<br />

2<br />

53<br />

48<br />

120.6<br />

55<br />

34.5<br />

20.5<br />

322<br />

353.5<br />

45 25<br />

5<br />

55<br />

45<br />

100<br />

0<br />

Y-IDP Double Port<br />

ø51<br />

V-NA Motorized Sextuple Nosepiece<br />

ø121<br />

V-ND MG-DIC Intelligent Sextuple Nosepiece<br />

ø121<br />

Y-FL Epi-Fl Attachment<br />

Eyepieces<br />

22.5<br />

22.5<br />

48–56<br />

48–56<br />

22.5<br />

22.5<br />

C-ND DIC6<br />

JAPAN<br />

ø30<br />

CFI 10X / 22<br />

ø34<br />

ø38.8<br />

ø30<br />

CFI 10X / 22M<br />

ø34<br />

ø38.8<br />

50<br />

105.8<br />

50<br />

123.2<br />

CFI 10x with diopter adjustment<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment<br />

22.5<br />

42–47<br />

22.5<br />

37–41<br />

ø30<br />

CFI 12.5X / 16<br />

ø35<br />

ø38.8<br />

ø30<br />

CFI 15X / 14.5<br />

ø35<br />

ø38.8<br />

53<br />

51.1<br />

48<br />

53<br />

48<br />

ø106<br />

ø121<br />

C-N Sextuple Nosepiece<br />

C-ND Sextuple DIC Nosepiece<br />

CFI 12.5x with diopter adjustment<br />

CFI 15x with diopter adjustment<br />

Type (magnification) F.O.V. Remarks<br />

CFI 10x with diopter adjustment<br />

22mm<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment 22mm With photom<strong>as</strong>k reticule<br />

CFI 12.5x with diopter adjustment<br />

16mm<br />

CFI 15x with diopter adjustment<br />

14.5mm<br />

20<br />

21


CCTV Camera Adapters<br />

Focal point<br />

Focal point<br />

3<br />

72<br />

27<br />

ø52<br />

35<br />

ø12<br />

9.3<br />

ø51<br />

ø38<br />

76.5<br />

C-mount screw<br />

41<br />

25.5<br />

TV camera imaging plane<br />

ø50<br />

ø25.4<br />

ø38<br />

11.47 17.526<br />

30˚<br />

C-Mount TV Adapter A<br />

ø23.1<br />

ø42<br />

ø53<br />

17.526<br />

30.7 27.3 4<br />

100.1<br />

C-Mount TV Adapter 0.45x<br />

ø23.1<br />

ø42<br />

ø53<br />

17.526<br />

30.7 27 4<br />

116.8<br />

C-Mount TV Adapter 0.6x<br />

Focal point<br />

ø38<br />

ø52<br />

ø38<br />

ø59<br />

Focal point<br />

V-T Photo Adapter<br />

Y-T TV Tube for C-Mount Adapter A<br />

38<br />

48<br />

ø34<br />

ø30<br />

44<br />

31<br />

Relay Lens 1x I<br />

ø58.5<br />

ø54<br />

75<br />

10<br />

Image plane <br />

on eyepiece tube side<br />

ø31<br />

ø42<br />

ø46<br />

45˚<br />

7.5<br />

27.3<br />

64.5<br />

C-Mount TV Adapter<br />

91.8 17.526<br />

95.8<br />

ø42<br />

ø47<br />

ø62<br />

ø63<br />

27.8 11.5<br />

ENG-Mount TV Adapter<br />

53.3<br />

61.3}0.1 48<br />

64.3<br />

ø23.1<br />

ø42<br />

ø53<br />

30.2 27<br />

4<br />

111.2<br />

ENG-Mount TV Adapter 0.45x<br />

(for Trinocular Tube “F”, “T”)<br />

ø23.1<br />

ø42<br />

ø53<br />

30.2 27.0<br />

3.3<br />

122.8<br />

ENG-Mount TV Adapter 0.6x<br />

(for Trinocular Tube “F”, “T”)<br />

Focal point<br />

130<br />

67.3<br />

40.2<br />

JAPAN<br />

ø44<br />

ø54<br />

C-mount screw<br />

45˚<br />

11.5 4<br />

7.5 42.8 17.526<br />

54.3<br />

ø44<br />

ø57<br />

48<br />

12.3<br />

7.5<br />

22.8<br />

Focal point<br />

ø53<br />

ø38<br />

42 29<br />

68<br />

ø53<br />

29<br />

83<br />

109<br />

ø23.1<br />

C-Mount Zooming Adapter<br />

ENG-Mount Zooming Adapter<br />

C-Mount TV Adapter VM 2.5x<br />

ø42<br />

ø38<br />

Zoom Lens<br />

C-Mount TV Adapter VM 4x<br />

22<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!