06.11.2014 Views

Download brochure as PDF - Nikon Instruments

Download brochure as PDF - Nikon Instruments

Download brochure as PDF - Nikon Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MICROSCOPE COMPONENTS<br />

FOR TRANSMITTED<br />

LIGHT APPLICATIONS<br />

Specifications and equipment are subject to change without any notice or<br />

obligation on the part of the manufacturer. June 2007. ©1997-07 NIKON CORPORATION<br />

NIKON CORPORATION<br />

Parale Mitsui Bldg., 8, Hig<strong>as</strong>hida-cho, Kaw<strong>as</strong>aki-ku,<br />

Kaw<strong>as</strong>aki, Kanagawa 210-0005, Japan<br />

phone: +81-44-223-2167 fax: +81-44-223-2182<br />

http://www.nikon-instruments.jp/eng/<br />

NIKON INSTRUMENTS INC.<br />

1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.<br />

phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only)<br />

fax: +1-631-547-0306<br />

http://www.nikonusa.com/<br />

NIKON INSTRUMENTS EUROPE B.V.<br />

P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands<br />

phone: +31-20-44-96-222 fax: +31-20-44-96-298<br />

http://www.nikon-instruments.com/<br />

NIKON INSTRUMENTS (SHANGHAI) CO., LTD.<br />

CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030<br />

(Beijing office) phone: +86-10-5869-2255 fax: +86-10-5869-2277<br />

(Guangzhou office) phone: +86-20-3882-0552 fax: +86-20-3882-0580<br />

NIKON SINGAPORE PTE LTD<br />

SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668<br />

NIKON MALAYSIA SDN. BHD.<br />

MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387<br />

NIKON INSTRUMENTS KOREA CO., LTD.<br />

KOREA phone: +82-2-2186-8410 fax: +82-2-555-4415<br />

NIKON CANADA INC.<br />

CANADA phone: +1-905-625-9910 fax: +1-905-625-0103<br />

NIKON FRANCE S.A.S.<br />

FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33<br />

NIKON GMBH<br />

GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322<br />

NIKON INSTRUMENTS S.p.A.<br />

ITALY phone: +39-55-3009601 fax: +39-55-300993<br />

NIKON AG<br />

SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861<br />

NIKON UK LTD.<br />

UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584<br />

NIKON GMBH AUSTRIA<br />

AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40<br />

NIKON BELUX<br />

BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45<br />

Printed in Japan (0706-03)T Code No. 2CE-MUZH-3 This <strong>brochure</strong> is printed on recycled paper made from 40% used material.<br />

En


Contents<br />

System Diagram<br />

2<br />

System Diagram .............................. 3<br />

CFI 60 Objectives<br />

CFI Achromat Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)............ 4~5<br />

CFI Achromat 4x<br />

CFI Achromat 10x / CFI Achromat DL 10x<br />

CFI Achromat LWD 20x / CFI Achromat LWD DL 20x<br />

CFI Achromat 40x / CFI Achromat DL 40x<br />

CFI Achromat 60x<br />

CFI Achromat 100x Oil / CFI Achromat DL 100x Oil<br />

CFI Achromat LWD DL 20x F<br />

CFI Achromat LWD 40x C / CFI Achromat LWD DL 40x C<br />

CFI Plan Achromat Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL) ............ 6~7<br />

CFI Plan Achromat UW 1x<br />

CFI Plan Achromat UW 2x<br />

CFI Plan Achromat 4x<br />

CFI Plan Achromat 10x / CFI Plan Achromat DL 10x<br />

CFI Plan Achromat 20x / CFI Plan Achromat DL 20x<br />

CFI Plan Achromat 40x / CFI Plan Achromat DL 40x<br />

CFI Plan Achromat 40x NCG<br />

CFI Plan Achromat 50x Oil<br />

CFI Plan Achromat 100x Oil / CFI Plan Achromat DL 100x Oil<br />

CFI Plan Achromat 100x NCG<br />

CFI Plan Fluor Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DLL) .......... 8~9<br />

CFI Plan Fluor 4x<br />

CFI Plan Fluor 10x / CFI Plan Fluor DLL 10x<br />

CFI Plan Fluor 20x / CFI Plan Fluor DLL 20x<br />

CFI Plan Fluor 40x / CFI Plan Fluor DLL 40x<br />

CFI Plan Fluor 40x Oil<br />

CFI Plan Fluor 60x C<br />

CFI Plan Fluor 100x Oil / CFI Plan Fluor DLL 100x Oil<br />

CFI Plan Fluor 100x Oil with iris diaphragm<br />

CFI Plan Fluor Series for Ph<strong>as</strong>e Contr<strong>as</strong>t (DL).... 9<br />

CFI Plan Fluor DL 4x<br />

CFI Plan Fluor DL 10x<br />

CFI Plan Fluor ELWD Series<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM/DLL) ........ 10<br />

CFI Plan Fluor ELWD 20x C / CFI Plan Fluor ELWD DM 20x C<br />

CFI Plan Fluor ELWD 40x C / CFI Plan Fluor ELWD DM 40x C<br />

CFI Plan Fluor ELWD 60x C / CFI Plan Fluor ELWD DLL 60x C<br />

Multi-Immersion Objective for Brightfield .....<br />

CFI Plan Fluor 20x MI<br />

CFI Plan Apochromat Series<br />

10<br />

for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM) ......... 11~12<br />

CFI Plan Apochromat 2x<br />

CFI Plan Apochromat 4x<br />

CFI Plan Apochromat 10x<br />

CFI Plan Apochromat 20x / CFI Plan Apochromat DM 20x<br />

CFI Plan Apochromat 40x C / CFI Plan Apochromat DM 40x C<br />

CFI Plan Apochromat 40x Oil / CFI Plan Apochromat DM 40x Oil<br />

CFI Plan Apochromat 60x C / CFI Plan Apochromat DM 60x C<br />

CFI Plan Apochromat 60x Oil / CFI Plan Apochromat DM 60x Oil<br />

CFI Plan Apochromat 60x WI<br />

CFI Plan Apochromat 100x Oil / CFI Plan Apochromat DM 100x Oil<br />

CFI Plan Apochromat 100x NCG Oil<br />

CFI S Fluor Series.......................................... 13<br />

CFI S Fluor 10x<br />

CFI S Fluor 20x<br />

CFI S Fluor 40x C<br />

CFI S Fluor 40x Oil<br />

CFI S Fluor 100x Oil<br />

Water Dipping Series.................................... 14<br />

CFI Fluor 10x W<br />

CFI Fluor 40x W<br />

CFI Fluor 60x W<br />

CFI HMC Series<br />

for Hoffmann Modulation Contr<strong>as</strong>t ® .............. 15<br />

CFI HMC 10x<br />

CFI HMC 20x F<br />

CFI HMC LWD 40x C<br />

2nd Objective Lens Unit ............................... 15<br />

Markings on CFI60 Objectives........................ 16<br />

17<br />

Condensers....................................<br />

C-C Abbe Condenser, Dry Type<br />

C-C Achromat Condenser<br />

Achromat Swing-out Condenser<br />

C-C Achromat /Aplanat Condenser<br />

LWD Achromat Condenser<br />

C-C Low Power Condenser<br />

Dark Field Condenser, Oil<br />

Dark Field Condenser, Dry<br />

C-CEL Expander Lens (for darkfield)<br />

Illumination Systems ................ 18~19<br />

Lamphouse HMX-3B<br />

Lamphouse HMX-4B, built-in back mirror<br />

Lamphouse HMX<br />

Mercury Lamp Socket S 100W for HMX-3B<br />

Halogen Lamp Socket 100W/HMX<br />

C-FC Epi-Fl Collector Lens<br />

Quartz Epi-Fl Collector Lens<br />

Collector Lens/QH100W<br />

C-LA HMX Lamphouse Adapter<br />

HMX Connecting Adapter SB-X1 (Bayonet to Screw)<br />

HMX Connecting Adapter SB-X2 (Screw to Bayonet)<br />

Eyepiece Tubes .............................. 19<br />

Y-TB Binocular Tube<br />

Y-TE Ergonomic Binocular Tube<br />

Y-TF Trinocular Tube “F” UW<br />

Y-TT Trinocular Tube “T” UW<br />

Intermediate Tubes ....................... 20<br />

Y-FL Epi-Fl Attachment<br />

Y-IDP Double Port<br />

Eyepieces......................................<br />

CFI 10x with diopter adjustment<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment<br />

CFI 12.5x with diopter adjustment<br />

CFI 15x with diopter adjustment<br />

20<br />

Nosepiece ...................................... 21<br />

V-NA Motorized Sextuple Nosepiece<br />

V-ND MG-DIC Intelligent Sextuple Nosepiece<br />

C-N Sextuple Nosepiece<br />

C-ND Sextuple DIC Nosepiece<br />

CCTV Camera Adapters ............. 22~23<br />

V-T Photo Adapter<br />

Y-T TV Tube for C-Mount Adapter A<br />

C-Mount TV Adapter A<br />

Relay Lens 1x I<br />

C-Mount TV Adapter<br />

ENG-Mount TV Adapter<br />

Zoom Lens<br />

C-Mount Zooming Adapter<br />

ENG-Mount Zooming Adapter<br />

C-Mount TV Adapter 0.45x<br />

C-Mount TV Adapter 0.6x<br />

ENG-Mount TV Adapter 0.45x (for Trinocular Tube “F”, “T”)<br />

ENG-Mount TV Adapter 0.6x (for Trinocular Tube “F”, “T”)<br />

C-Mount TV Adapter VM 2.5x<br />

C-Mount TV Adapter VM 4x<br />

Mercury Lamp<br />

Socket S 100W<br />

Halogen Lamp<br />

Socket 100W/HMX<br />

C-C Abbe Condenser<br />

(Dry)<br />

ENG-Mount CCTV Camera<br />

ENG-Mount<br />

TV Adapter<br />

ENG-Mount<br />

TV<br />

Adapter*1*2<br />

0.45X, 0.6X<br />

Y-T TV Tube<br />

for C-Mount<br />

Adapter A<br />

Lamphouse HMX-3B<br />

Lamphouse HMX-4B<br />

with Built-in Back Mirror<br />

Lamphouse HMX<br />

ENG-<br />

Mount<br />

Zooming<br />

Adapter<br />

Relay<br />

Lens 1X I<br />

V-T Photo Adapter<br />

C-C Achromat Condenser<br />

C-Mount<br />

Zooming<br />

Adapter<br />

Zoom Lens<br />

Illumination Systems<br />

C-LA HMX Lamphouse Adapter<br />

HMX Connecting Adapter SB-X1<br />

(Bayonet to Screw Mount)<br />

HMX Connecting Adapter SB-X2<br />

(Screw to Bayonet Mount)<br />

C-FC Epi-Fl Collector Lens<br />

Quartz Epi-Fl Collector Lens<br />

Collector Lens/QH 100W<br />

Achromat Swing-out<br />

Condenser<br />

C-Mount TV<br />

Adapter<br />

Relay Lens<br />

1X I<br />

C-C Achromat/Aplanat<br />

Condenser<br />

C-Mount CCTV Camera<br />

C-Mount<br />

TV Adapter<br />

0.45X, 0.6X<br />

Condensers<br />

C-Mount<br />

TV<br />

Adapter A<br />

Y-TT Trinocular Tube "T" UW Y-TF Trinocular Tube "F" UW Y-TB Binocular Tube Y-TE Ergonomic<br />

Binocular Tube<br />

V-NA<br />

Motorized<br />

Sextuple Nosepiece<br />

LWD Achromat<br />

Condenser<br />

C-Mount<br />

TV Adapter<br />

VM2.5X<br />

CFI 10X<br />

with Diopter Adjustment<br />

C-Mount TV<br />

Adapter A<br />

C-Mount<br />

TV Adapter<br />

VM4X<br />

CFI 10XM<br />

Photom<strong>as</strong>k with<br />

Diopter Adjustment<br />

Eyepiece Tubes<br />

Y-FL Epi-Fl Attachment<br />

V-ND<br />

MG-DIC Intelligent<br />

Sextuple Nosepiece<br />

C-C Low Power<br />

Condenser<br />

C-Mount<br />

TV Adapter A<br />

CFI 12.5X<br />

with Diopter Adjustment<br />

Y-IDP Double Port<br />

Intermediate Tubes<br />

CCTV Camera Adapters<br />

*1: Use the dedicated 0.45X adapter for the double port sub-port.<br />

The 0.6X adapter cannot be used with the double port sub-port.<br />

*2: ENG-mount CCTV adapter 0.45x is a 38-bayonet mount type;<br />

other ENG-mount CCTV adapters are 48-bayonet mount types.<br />

C-N<br />

Sextuple<br />

Nosepiece<br />

CFI60 Objectives<br />

Darkfield Condenser (Oil)<br />

C-CEL Expander Lens<br />

Eyepieces<br />

CFI 15X<br />

with Diopter Adjustment<br />

Intermediate Tubes<br />

Nosepieces<br />

C-ND DIC<br />

Nosepiece<br />

Darkfield Condenser<br />

(Dry)<br />

3


CFI60 OBJECTIVES<br />

CFI Achromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

Correction for chromatic aberration in these objectives have been dramatically improved and are at the same level<br />

<strong>as</strong> the CFI Plan Achromat Series. These objectives were also corrected for spherical aberration and coma and<br />

image flatness across the 22mm field of view h<strong>as</strong> been dr<strong>as</strong>tically improved.<br />

The result: truly exceptional quality for this cl<strong>as</strong>s of objectives.<br />

The DL ph<strong>as</strong>e contr<strong>as</strong>t objectives in this series have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t<br />

with unstained specimens.<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

ø25<br />

ø17<br />

ø14.3<br />

ø8.1<br />

ø28.2<br />

ø25.5<br />

ø20<br />

ø12.2<br />

4.5<br />

ø27<br />

M25~0.75<br />

4.5<br />

4.5<br />

45˚<br />

4.2<br />

60.41<br />

D 20X /0.4<br />

Ph1 DL<br />

/1.2 WD 3.0<br />

M25~0.75<br />

ø27<br />

45˚<br />

6<br />

35˚<br />

3 4.5<br />

19.9 10<br />

30˚<br />

C1<br />

4 X /0.10<br />

/- WD 30<br />

ø25<br />

60.06<br />

2.3 5 36.5<br />

10<br />

45˚<br />

45˚<br />

10X /0.25<br />

/- WD 6.1<br />

ø10<br />

ø16<br />

ø25<br />

60.06<br />

4.1 6 36<br />

10<br />

45˚<br />

45˚<br />

20X /0.40<br />

/0.17 WD 3.8<br />

ø8<br />

ø14.3<br />

ø17<br />

ø25<br />

60.06<br />

4.5 10<br />

36<br />

60.41<br />

D 40X /0.55<br />

WD 2.1<br />

/0–2<br />

2 1.6 1.2 0.8 0.4 0<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

5 24.6 25<br />

CFI Achromat 4x<br />

CFI Achromat 10x<br />

CFI Achromat DL 10x<br />

CFI Achromat LWD 20x<br />

CFI Achromat LWD DL 20x<br />

CFI Achromat LWD DL 20x F<br />

CFI Achromat LWD 40x C<br />

CFI Achromat LWD DL 40x C<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

ø27<br />

M25~0.75<br />

3.7 3 8<br />

34.5<br />

10 5<br />

45˚<br />

35˚<br />

40X /0.65<br />

WD 0.65<br />

/0.17<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

60.06<br />

CFI Achromat 40x<br />

CFI Achromat DL 40x<br />

5<br />

3 8<br />

34.5<br />

10<br />

4.1<br />

45˚<br />

35˚<br />

60X /0.80<br />

/0.17 WD 0.3<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

CFI Achromat 60x<br />

60.06<br />

5<br />

5 8<br />

34.5<br />

10<br />

2.2<br />

45˚<br />

20˚<br />

00X / 1.25 oil<br />

/0.17 WD 0.18<br />

ø5<br />

ø13<br />

ø16.6<br />

ø20<br />

ø25<br />

60.06<br />

CFI Achromat 100x Oil<br />

CFI Achromat DL 100x Oil<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Achromat 4x 0.10 30.0 50.0 27.50 72<br />

CFI Achromat 10x 0.25 6.1 20.0 4.40 85<br />

CFI Achromat DL 10x 0.25 6.1 20.0 4.40 85 ph1<br />

CFI Achromat LWD 20x 0.40 3.8 10.0 1.72 90<br />

CFI Achromat LWD DL 20x 0.40 3.8 10.0 1.72 90 ph1<br />

CFI Achromat 40x 0.65 0.65 5.0 0.65 130 Spring-loaded<br />

CFI Achromat DL 40x 0.65 0.65 5.0 0.65 130 Spring-loaded ph2<br />

CFI Achromat 60x 0.80 0.3 3.3 0.43 130 Spring-loaded<br />

CFI Achromat 100x Oil 1.25 0.18 2.0 0.27 130 Spring-loaded<br />

CFI Achromat DL 100x Oil 1.25 0.18 2.0 0.27 130 Spring-loaded ph3<br />

CFI Achromat LWD DL 20x F 0.40 3.0 10.0 1.72 90 Cover gl<strong>as</strong>s thickness 1.2mm ph1<br />

CFI Achromat LWD 40x C 0.55 2.7–1.7 5.0 0.91 195 Cover gl<strong>as</strong>s correction 0.2mm<br />

CFI Achromat LWD DL 40x C 0.55 2.7–1.7 5.0 0.91 195 Cover gl<strong>as</strong>s correction 0.2mm ph2<br />

4<br />

5


CFI60 OBJECTIVES<br />

CFI Plan Achromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

These objectives provide incredible image flatness over the entire 25mm field of view, with chromatic aberration<br />

corrected throughout the entire visible spectrum. These objectives are suitable not only for routine laboratory work<br />

but for photomicrography.<br />

The DL ph<strong>as</strong>e contr<strong>as</strong>t objectives in this series have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t<br />

with unstained specimens.<br />

10.7 46<br />

5<br />

ø30<br />

M25~0.75<br />

Plan UW<br />

1X /0.04<br />

/-WD 3.2<br />

60.06<br />

52.4 5<br />

5<br />

ø30<br />

M25~0.75<br />

Plan UW<br />

2X /0.06<br />

/-WD 7.5<br />

60.06<br />

19.9 10 4.5<br />

ø27<br />

M25~0.75<br />

Plan 4X/0.<br />

/-WD 3<br />

60.06<br />

5.5 3.5<br />

50.5<br />

5.3<br />

3<br />

45˚<br />

45˚<br />

ø30<br />

M25~0.75<br />

Plan<br />

40 X /0.65 N<br />

/ 0 WD 0.48<br />

ø7.5<br />

ø14<br />

ø18.8<br />

60<br />

CFI Plan Achromat 40x NCG<br />

ø27<br />

M25~0.75<br />

4.5 4.3 51.2<br />

5.3<br />

45˚<br />

30˚<br />

ø30<br />

M25~0.75<br />

Plan<br />

50 X /0.90 oil<br />

/- WD 0.40<br />

ø5.5<br />

ø14<br />

ø18.8<br />

60.06 (NCG)<br />

CFI Plan Achromat 50x Oil<br />

ø30<br />

M25~0.75<br />

2.4 37<br />

10 5<br />

ø31<br />

CFI Plan Achromat UW 1x<br />

45˚<br />

45˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

10X /0.25<br />

/-WD 10.5<br />

ø12<br />

ø19<br />

ø25<br />

60.06<br />

CFI Plan Achromat 10x<br />

CFI Plan Achromat DL 10x<br />

4.6 5 4.5<br />

34.5<br />

10 4.5<br />

ø20<br />

CFI Plan Achromat UW 2x<br />

45˚<br />

45˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

20 X /0.40<br />

/ 0.17 WD 1.3<br />

ø7<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

60.06<br />

CFI Plan Achromat 20x<br />

CFI Plan Achromat DL 20x<br />

3.3 4 7.5<br />

34.5<br />

10 5<br />

ø25<br />

CFI Plan Achromat 4x<br />

45˚<br />

30˚<br />

ø27<br />

M25~0.75<br />

Plan<br />

40 X /0.65<br />

/ 0.17<br />

ø6<br />

ø13<br />

ø17<br />

ø20<br />

ø25<br />

WD0.57<br />

60.06<br />

CFI Plan Achromat 40x<br />

CFI Plan Achromat DL 40x<br />

2.2 4 9 44.5<br />

5<br />

45˚<br />

22.5˚<br />

Plan<br />

100 X /1.25<br />

/ 0.17 WD 0.17<br />

ø5.3<br />

ø13<br />

ø16.8<br />

ø20<br />

ø25<br />

60.06<br />

CFI Plan Achromat 100x Oil<br />

CFI Plan Achromat DL 100x Oil<br />

5<br />

51.2<br />

2.2 6.3<br />

2<br />

45˚<br />

20˚<br />

Plan<br />

100 X /0.90 N<br />

/ 0 WD 0.26<br />

ø5.5<br />

ø14<br />

ø18.8<br />

60<br />

CFI Plan Achromat 100x NCG<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Achromat UW 1x 0.04 3.2 200.0 171.88 180<br />

CFI Plan Achromat UW 2x 0.06 7.5 100.0 76.39 110<br />

CFI Plan Achromat 4x 0.10 30.0 50.0 27.50 65<br />

CFI Plan Achromat 10x 0.25 10.5 20.0 4.40 85<br />

CFI Plan Achromat DL 10x 0.25 10.5 20.0 4.40 85 ph1<br />

CFI Plan Achromat 20x 0.40 1.3 20.0 1.72 85<br />

CFI Plan Achromat DL 20x 0.40 1.3 20.0 1.72 85 ph1<br />

CFI Plan Achromat 40x 0.65 0.57 5.0 0.65 115 Spring-loaded<br />

CFI Plan Achromat DL 40x 0.65 0.57 5.0 0.65 115 Spring-loaded ph2<br />

CFI Plan Achromat 40x NCG 0.65 0.48 5.0 0.65 160 Spring-loaded No cover gr<strong>as</strong>s<br />

CFI Plan Achromat 50x Oil 0.90 0.4 4.0 0.52 160 Spring-loaded<br />

CFI Plan Achromat 100x Oil 1.25 0.17 3.3 0.52 160 Spring-loaded<br />

CFI Plan Achromat DL 100x Oil 1.25 0.17 3.3 0.52 160 Spring-loaded ph3<br />

CFI Plan Achromat 100x NCG 0.90 0.26 2.0 0.18 160 Spring-loaded No cover gr<strong>as</strong>s<br />

6<br />

7


CFI60 OBJECTIVES<br />

CFI Plan Fluor Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DLL)<br />

Featuring an extra-high transmission<br />

rate, especially in the ultraviolet<br />

wavelength, and flatness of field<br />

comparable to the CFI Plan Achromat<br />

series, these objectives are designed<br />

for fluorescence observation and<br />

photomicrography. Because of this<br />

improvement in quality, these<br />

objectives can function <strong>as</strong> multipurpose<br />

objectives for brightfield,<br />

fluorescence, polarizing, and DIC<br />

observations.<br />

The DLL (low contr<strong>as</strong>t) ph<strong>as</strong>e<br />

objectives for this series can also be<br />

used <strong>as</strong> universal objectives for<br />

ph<strong>as</strong>e contr<strong>as</strong>t, fluorescence, DIC,<br />

and brightfield techniques.<br />

5.3<br />

42.8<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

4X / 0.13<br />

/ - WD 17.1<br />

ø20<br />

CFI Plan Fluor 4x<br />

45˚<br />

5.3<br />

43.9<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

10X / 0.30<br />

DIC L@<br />

/0.17 WD 16.0<br />

ø18<br />

CFI Plan Fluor 10x<br />

CFI Plan Fluor DLL 10x<br />

45˚<br />

1.7<br />

5.3<br />

10.8 11<br />

32<br />

3.9<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

60X / 0.85<br />

DIC M<br />

/0.11-0.23 WD 0.30<br />

11 14 17 20 23<br />

ø8.5<br />

ø18<br />

ø22<br />

ø33<br />

30˚<br />

30˚<br />

5.3<br />

3.8 4.5<br />

51.5<br />

ø30<br />

Plan Fluor<br />

100X/1.30 oil<br />

DIC H<br />

/0.17 WD 0.20<br />

ø5.8<br />

ø17<br />

ø21<br />

20˚<br />

45˚<br />

6.2<br />

2.6<br />

5.3<br />

34<br />

2.9 6.5 7.5<br />

17˚<br />

ø33.4<br />

ø32<br />

ø30<br />

M25~0.75<br />

Plan Fluor<br />

100X/0.5-1.3 oil<br />

/0.17 WD 0.2<br />

1.3 0.7<br />

ø5.3<br />

ø19.8<br />

ø23.6<br />

ø32<br />

C2.5<br />

8˚<br />

ø30<br />

M25~0.75<br />

ø30<br />

M25~0.75<br />

ø33.5<br />

ø30<br />

CFI Plan Fluor 60x C<br />

CFI Plan Fluor 100x Oil<br />

CFI Plan Fluor DLL 100x Oil<br />

CFI Plan Fluor 100x Oil with<br />

iris diaphragm<br />

5.3<br />

54<br />

Plan Fluor<br />

20X / 0.50<br />

DIC M<br />

/0.17 WD 2.1<br />

45˚<br />

5.3<br />

57.2<br />

5.5<br />

Plan Fluor<br />

40X / 0.75<br />

DIC M<br />

/0.17 WD 0.72<br />

40<br />

12 5.3<br />

45˚<br />

60.41<br />

Plan Fluor<br />

4X / 0.13<br />

PhL DL<br />

/1.2 WD 16.4<br />

45˚<br />

5<br />

42.8<br />

5.3<br />

M25~0.75<br />

Plan Fluor<br />

40X / 1.30 oil<br />

DIC H<br />

/0.17 WD 0.2<br />

CFI Plan Fluor Series for Ph<strong>as</strong>e Contr<strong>as</strong>t (DL)<br />

These objectives have more contr<strong>as</strong>t than the DLL objectives for enhanced contr<strong>as</strong>t with tissue culture<br />

specimens. These objectives are designed for use on inverted microscopes and therefore their markings are<br />

upside-down for e<strong>as</strong>y reading.<br />

1.2<br />

45˚<br />

3.8<br />

2.7<br />

ø12<br />

ø17<br />

CFI Plan Fluor 20x<br />

CFI Plan Fluor DLL 20x<br />

2<br />

ø10<br />

45˚<br />

CFI Plan Fluor 40x<br />

CFI Plan Fluor DLL 40x<br />

4<br />

3.7<br />

23˚<br />

ø8<br />

ø22<br />

ø25.8<br />

CFI Plan Fluor 40x Oil<br />

60.41<br />

Plan Fluor<br />

10X / 0.30<br />

Ph1 DL<br />

/1.2 WD 15.2<br />

45˚<br />

6<br />

44<br />

5.3<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor 4x 0.13 17.1 50.0 16.27 110<br />

CFI Plan Fluor 10x 0.30 16.0 20.0 3.06 120<br />

CFI Plan Fluor DLL 10x 0.30 16.0 20.0 3.06 120 ph1<br />

CFI Plan Fluor 20x 0.50 2.1 10.0 1.10 175<br />

CFI Plan Fluor DLL 20x 0.50 2.1 10.0 1.10 175 ph1<br />

CFI Plan Fluor 40x 0.75 0.72 5.0 0.49 210 Spring-loaded<br />

CFI Plan Fluor DLL 40x 0.75 0.72 5.0 0.49 210 Spring-loaded ph2<br />

CFI Plan Fluor 40x Oil 1.30 0.2 5.0 0.25 230 Spring-loaded Stopper<br />

CFI Plan Fluor 60x C 0.85 0.3 3.3 0.38 265 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Fluor 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper<br />

CFI Plan Fluor DLL 100x Oil 1.30 0.2 2.0 0.25 250 Spring-loaded Stopper ph3<br />

CFI Plan Fluor 100x Oil with iris diaphragm 0.5–1.3 0.2 2.0 0.25 285 Spring-loaded With iris diaphragm<br />

M25~0.75<br />

M25~0.75<br />

ø30<br />

ø30<br />

CFI Plan Fluor DL 4x<br />

CFI Plan Fluor DL 10x<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor DL 4x 0.13 16.4 50.0 16.27 105 Cover gl<strong>as</strong>s thickness 1.2mm phL<br />

CFI Plan Fluor DL 10x 0.30 15.2 20.0 3.06 120 Cover gl<strong>as</strong>s thickness 1.2mm ph1<br />

8<br />

9


CFI60 OBJECTIVES<br />

CFI Plan Fluor ELWD Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM/DLL)<br />

Offering superb flatness of field, high UV transmission rates, and high Numerical Apertures with extra long working distances, these objectives are<br />

well suited for fluorescence observations, especially with inverted microscopes. Because of their superior optical design, CFI Plan Fluor ELWD DM<br />

objectives can be used universally for all other observation techniques, including brightfield, fluorescence, ph<strong>as</strong>e contr<strong>as</strong>t, and Nomarski DIC.<br />

The DM ph<strong>as</strong>e contr<strong>as</strong>t objectives have higher contr<strong>as</strong>t to enhance the image of very thin, highly detailed specimens with low ph<strong>as</strong>e gradients.<br />

The DLL objectives have less contr<strong>as</strong>t for thicker, more contr<strong>as</strong>ty specimens.<br />

1.2<br />

Standard<br />

thickness<br />

ø32.5<br />

ø28.7<br />

ø25.5<br />

ø16.4<br />

ø32.5<br />

ø29<br />

ø27.5<br />

ø13.3<br />

ø32.5<br />

ø26.3<br />

ø10<br />

CFI Plan Apochromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM)<br />

These objectives feature longer working distances with high Numerical Apertures and is designed to correct all<br />

optical aberrations throughout the visible spectrum from violet to red from center to edges across the entire 25mm<br />

field of view. Superior image flatness and color reproduction, plus resolving power at the theoretical limit of today's<br />

optical technology are also featured.<br />

The DM ph<strong>as</strong>e contr<strong>as</strong>t Plan Apochromats have higher contr<strong>as</strong>t to enhance images of very thin, highly detailed<br />

specimens with low ph<strong>as</strong>e gradients.<br />

60.41<br />

Plan Fluor<br />

LWD 20X/0.45<br />

/ 0-2 WD 7.4<br />

25˚<br />

5˚<br />

22.2 1.8<br />

1.8<br />

60.41<br />

Plan Fluor<br />

LWD 40X/0.60<br />

/0-2 WD 3.7 - 2.7<br />

20˚<br />

5<br />

26.5 2.5<br />

2.5<br />

60.41<br />

Plan Fluor<br />

WD 60X/0.70<br />

0.5-1.5 WD 2.1-1.5<br />

22.5<br />

7.5˚<br />

33<br />

5.3<br />

ø30<br />

M25~0.75<br />

5.3<br />

ø30<br />

M25~0.75<br />

5.3<br />

ø30<br />

M25~0.75<br />

2 1.6 1.2 0.8 0.4 0<br />

ø29<br />

ø32<br />

ø34<br />

7˚<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 20x C<br />

CFI Plan Fluor ELWD DM 20x C<br />

2 1.6 1.2 0.8 0.4 0<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

7˚<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 40x C<br />

CFI Plan Fluor ELWD DM 40x C<br />

1.5 1.2 1 0.8 0.5<br />

M25~0.75<br />

ø29<br />

ø33<br />

ø34<br />

9˚<br />

6<br />

11.5<br />

13<br />

5<br />

CFI Plan Fluor ELWD 60x C<br />

CFI Plan Fluor ELWD DLL 60x C<br />

51.4<br />

45˚<br />

Plan Apo<br />

2X / 0.1<br />

/ - WD 8.5<br />

ø19<br />

WD=8.5<br />

CG=0.17<br />

60.06<br />

44.2<br />

30<br />

Plan Apo<br />

4X / 0.2<br />

/ - WD 15.7<br />

ø18<br />

WD=15.7<br />

CG=0.17<br />

60.06<br />

55.9<br />

45˚<br />

Plan Apo<br />

10X / 0.45<br />

DIC L<br />

/0.17 WD 4.0<br />

ø15<br />

WD=4.0<br />

CG=0.17<br />

60.06<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Fluor ELWD 20x C 0.45 8.1–7.0 10.0 1.36 195 Cover gl<strong>as</strong>s correction 0–2mm<br />

CFI Plan Fluor ELWD DM 20x C 0.45 8.1–7.0 10.0 1.36 195 Cover gl<strong>as</strong>s correction 0–2mm ph1<br />

CFI Plan Fluor ELWD 40x C 0.60 3.7–2.7 5.0 0.76 195 Cover gl<strong>as</strong>s correction 0–2mm<br />

CFI Plan Fluor ELWD DM 40x C 0.60 3.7–2.7 5.0 0.76 195 Cover gl<strong>as</strong>s correction 0–2mm ph2<br />

CFI Plan Fluor ELWD 60x C 0.70 2.1–1.5 3.3 0.56 210 Cover gl<strong>as</strong>s correction 0.5–1.5mm<br />

CFI Plan Fluor ELWD DLL 60x C 0.70 2.1–1.5 3.3 0.56 210 Cover gl<strong>as</strong>s correction 0.5–1.5mm ph2<br />

CFI Plan Apochromat 2x<br />

CFI Plan Apochromat 4x<br />

CFI Plan Apochromat 10x<br />

10<br />

Multi-Immersion Objective for Brightfield<br />

This multi-purpose immersion objective h<strong>as</strong> a higher numerical aperture and<br />

superior contr<strong>as</strong>t. The use of immersion media helps eliminate surface<br />

reflections and provides an image with higher contr<strong>as</strong>t. It is an excellent<br />

objective for fluorescence, brightfield, and DIC observation techniques.<br />

This unique objective h<strong>as</strong> a correction collar that allows it to be used with<br />

immersion oil, glycerin, and water (with and without a cover gl<strong>as</strong>s).<br />

Objective N.A. W.D. Focal length Physical depth Weight Remarks<br />

(magnification) (mm) (mm) of focus (µm) (g)<br />

CFI Plan Fluor 20x MI 0.75 0.35–0.33 10.0 0.49 300<br />

Multi-immersion<br />

Oil-glycerine-water<br />

10.4 19 12.5 14 5.3<br />

3.7<br />

Oil G<br />

ø36<br />

ø34.5<br />

ø30.6<br />

M25~0.75<br />

Plan Fluor<br />

20X / 0.75 Mlmm<br />

/ - WD 0.35<br />

ø8<br />

ø28<br />

ø33<br />

0.17 W<br />

0<br />

CFI Plan Fluor 20x MI<br />

40˚<br />

8˚<br />

3˚<br />

30˚<br />

5.3<br />

12<br />

5.9 2.5 38.5<br />

45˚<br />

30˚<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

20X / 0.75<br />

DIC M<br />

/0.17 WD 1.0<br />

ø13.5<br />

ø22<br />

ø26<br />

WD=1.0<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 20x<br />

CFI Plan Apochromat DM 20x<br />

1.7<br />

4.2 10.8 11<br />

32 5.3<br />

30˚<br />

30˚<br />

3˚<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

40X / 0.95<br />

DIC M<br />

/0.11-0.23 WD 0.14<br />

11 14 17 20 23<br />

ø7<br />

ø18<br />

ø22<br />

ø33<br />

WD=0.14<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 40x C<br />

CFI Plan Apochromat DM 40x C<br />

5<br />

12<br />

4.7 4.5 38.5<br />

45˚<br />

30˚<br />

5˚<br />

ø32<br />

ø30<br />

ø25<br />

Plan Apo<br />

40X / 1.0 oil<br />

DIC H<br />

/0.17 WD 0.16<br />

ø8<br />

ø18.8<br />

ø22.8<br />

WD=0.16 (oil)<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 40x Oil<br />

CFI Plan Apochromat DM 40x Oil<br />

11


CFI60 OBJECTIVES<br />

1.7<br />

5.3<br />

32<br />

11<br />

10.8<br />

4.2<br />

30˚<br />

30˚<br />

3˚<br />

ø34.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /0.95<br />

DIC M<br />

/ 0.11-0.23 WD 0.15<br />

11 14 17 20 23<br />

ø7<br />

ø18<br />

ø22<br />

ø33<br />

WD=0.15<br />

CG=0.17<br />

60.06<br />

CFI Plan Apochromat 60x C<br />

CFI Plan Apochromat DM 60x C<br />

ø30<br />

M25~0.75<br />

CFI Plan Apochromat Series for Brightfield/Ph<strong>as</strong>e Contr<strong>as</strong>t (DM)<br />

3.7 4<br />

40<br />

12 5.3<br />

45˚<br />

22.5˚<br />

8˚<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /1.40 oil<br />

DIC H<br />

/ 0.17 WD 0.21<br />

ø7.2<br />

ø22<br />

ø25.8<br />

CG=0.17 WD=0.21 (oil)<br />

60.06<br />

CFI Plan Apochromat 60x Oil<br />

CFI Plan Apochromat DM 60x Oil<br />

ø30<br />

M25~0.75<br />

59.7 5.3<br />

23.5<br />

11<br />

11.9<br />

10.4<br />

2.9<br />

30˚<br />

7˚<br />

5˚<br />

30˚<br />

ø36.5<br />

ø35.2<br />

ø30<br />

M25~0.75<br />

Plan Apo<br />

60X /1.20 WI<br />

/ 0.15-0.18 WD 0.22<br />

15 16 17 18<br />

ø7.5<br />

ø29<br />

ø33.4<br />

CFI Plan Apochromat 60x WI<br />

CFI S Fluor Series<br />

These objectives ensure a high transmission rate of ultraviolet wavelengths down to 340 nm for fluorochromes like<br />

indo-1, fura-2, and fluor-3. Also, these objectives have improved signal-to-noise ratios (S/N) for short wavelengths and<br />

have high N.A., making the fluorescence images they produce significantly sharper and brighter.<br />

64<br />

5.3<br />

12<br />

38.5<br />

8.2<br />

ø32<br />

ø30<br />

M25~0.75<br />

S Fluor<br />

10 X / 0.50<br />

/ 0.17 WD 0.12<br />

ø8<br />

ø19<br />

ø24<br />

1.2<br />

64.2<br />

5.3<br />

5.9 41<br />

12<br />

ø33.5<br />

ø30<br />

M25~0.75<br />

S Fluor<br />

20 X / 0.75<br />

/ 0.17 WD 1.0<br />

ø9<br />

ø22<br />

ø25<br />

1<br />

5<br />

27<br />

3.1 8.5 10.5 10.5<br />

ø34.5<br />

ø33<br />

ø30<br />

M25~0.75<br />

Fluor 40 X / 0.9<br />

/ 0.11-0.23 WD 0.3<br />

11 14 17 20 23<br />

ø7.5<br />

ø18<br />

ø26<br />

ø33<br />

CFI S Fluor 10x<br />

CFI S Fluor 20x<br />

CFI S Fluor 40x C<br />

5.3<br />

59.8<br />

51.5<br />

Plan Apo<br />

100 X /1.40 oil<br />

DIC H<br />

/ 0.17 WD 0.13<br />

60.06<br />

59.8 5.3<br />

51.5<br />

Plan Apo<br />

00X /1.40 oilN<br />

/ 0 WD 0.17<br />

60<br />

5<br />

12<br />

ø32<br />

ø30<br />

M25~0.75<br />

5<br />

ø32<br />

ø30<br />

M25~0.75<br />

4.5<br />

3.8<br />

20˚<br />

C2<br />

ø5.8<br />

ø17<br />

ø21<br />

WD=0.13<br />

4.5<br />

3.8<br />

C2<br />

20˚<br />

ø5.8<br />

ø17<br />

ø21<br />

WD=0.17<br />

37<br />

S Fluor<br />

40 X / 1.30<br />

/ 0.17 WD 0.22<br />

Oil<br />

64.7<br />

32<br />

7.5<br />

7.5<br />

S Fluor<br />

100 X /0.5-1.3 oil<br />

/ 0.17 WD 0.2<br />

1.3 0.7<br />

CFI Plan Apochromat 100x Oil<br />

CFI Plan Apochromat DM 100x Oil<br />

CFI Plan Apochromat 100x NCG Oil<br />

6.5<br />

9.8<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks Ph<strong>as</strong>e ring<br />

CFI Plan Apochromat 2x 0.10 8.5 100.0 27.50 180<br />

CFI Plan Apochromat 4x 0.20 15.7 50.0 6.88 180<br />

CFI Plan Apochromat 10x 0.45 4.0 20.0 1.36 220<br />

CFI Plan Apochromat 20x 0.75 1.0 10.0 0.49 240 Spring-loaded<br />

CFI Plan Apochromat DM 20x 0.75 1.0 10.0 0.49 240 Spring-loaded ph2<br />

CFI Plan Apochromat 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Apochromat DM 40x C 0.95 0.14 5.0 0.30 270 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />

CFI Plan Apochromat 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 40x Oil 1.0 0.16 5.0 0.42 240 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI Plan Apochromat DM 60x C 0.95 0.15 3.3 0.30 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm ph2<br />

CFI Plan Apochromat 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 60x Oil 1.40 0.21 3.3 0.21 285 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 60x WI 1.20 0.22 3.3 0.25 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.15–0.18mm<br />

Water immersion<br />

CFI Plan Apochromat 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper<br />

CFI Plan Apochromat DM 100x Oil 1.40 0.13 2.0 0.21 245 Spring-loaded Stopper ph3<br />

CFI Plan Apochromat 100x NCG Oil 1.40 0.17 2.0 0.21 245 Spring-loaded Stopper No cover gl<strong>as</strong>s<br />

4.2<br />

ø8.3<br />

ø20<br />

ø23.8<br />

CFI S Fluor 40x Oil<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI S Fluor 10x 0.50 1.2 10.0 1.10 275 Spring-loaded<br />

CFI S Fluor 20x 0.75 1.0 10.0 0.49 275 Spring-loaded<br />

CFI S Fluor 40x C 0.90 0.3 5.0 0.34 285 Spring-loaded Cover gl<strong>as</strong>s correction 0.11–0.23mm<br />

CFI S Fluor 40x Oil 1.30 0.22 5.0 0.25 275 Spring-loaded<br />

CFI S Fluor 100x Oil 1.30 0.2 2.0 0.25 285 Spring-loaded<br />

2.9<br />

ø6<br />

ø17<br />

ø24<br />

ø29.5<br />

CFI S Fluor 100x Oil<br />

12<br />

13


CFI60 OBJECTIVES<br />

Water Dipping Series CFI HMC ® Series for Hoffmann Modulation Contr<strong>as</strong>t ®<br />

These objectives (no cover gl<strong>as</strong>s) are designed with a narrow top and a 2mm working distance to allow<br />

microelectrodes to be inserted into the specimen at 45°. They use ceramic and gl<strong>as</strong>s nose cones to isolate them<br />

thermally and electronically. Since they are FLUOR lenses, they are designed for fluorescence and have very high<br />

transmission in the UV and IR wavelengths with a high signal-to-noise ratio for superior images.<br />

ø29<br />

M25~0.75<br />

ø29<br />

M25~0.75<br />

ø29<br />

M25~0.75<br />

These objectives have been completely redesigned by <strong>Nikon</strong>, allowing the contr<strong>as</strong>t direction to be changed using<br />

a modulator inside the objective. That direction, once set, is maintained over the entire magnification range from<br />

10X to 40X.<br />

Note: Hoffman Modulation Contr<strong>as</strong>t and HMC are registered trademarks of Modulation Optics Inc.<br />

ø25<br />

ø13.3<br />

ø10<br />

ø25<br />

ø16.5<br />

ø15<br />

ø8<br />

ø33.3<br />

ø32<br />

ø28.8<br />

ø25.5<br />

ø20<br />

ø12<br />

5<br />

58.5<br />

32.7<br />

1.5 12 3.8 8.5<br />

55˚<br />

45˚<br />

Fluor<br />

10X / 0.30 W<br />

DIC L<br />

/ 0 WD 2.0<br />

ø3.5<br />

ø5<br />

ø20.5<br />

ø24<br />

ø26<br />

48˚<br />

2 (Water dipping)<br />

60.5<br />

5<br />

58.5<br />

32.7<br />

4.5 5 5 11.3<br />

50˚<br />

45˚<br />

Fluor<br />

40X / 0.80 W<br />

DIC M<br />

/ 0 WD 2.0<br />

ø4<br />

ø11.5<br />

ø19<br />

ø23<br />

ø25.5<br />

45˚<br />

2 (Water dipping)<br />

60.5<br />

5<br />

58.5<br />

32.7<br />

1 5.5 8 11.3<br />

40˚<br />

30˚<br />

Fluor<br />

60X / 1.00 W<br />

DIC H<br />

/ 0 WD 2.0<br />

ø5.5<br />

ø19.2<br />

ø23<br />

ø25.5<br />

33.7˚<br />

2 (Water dipping)<br />

60.5<br />

60.41<br />

45˚<br />

45˚<br />

10X / 0.25<br />

/ 1.2 WD 5.2<br />

MC1 HMC<br />

M25~0.75<br />

ø27<br />

ø27.8<br />

4.5 10 13<br />

28.5 4.5 2.5<br />

60.41<br />

45˚<br />

45˚<br />

D 20X / 0.4<br />

/ 1.2 WD 3.0<br />

MC2 HMC<br />

M25~0.75<br />

ø27<br />

ø27.8<br />

4.8<br />

10 13<br />

28.5<br />

4.5<br />

60.41<br />

WD 40X / 0.55<br />

/0- 2 WD 2.7-1.7<br />

2<br />

MC3 HMC<br />

1.6 1.2 0.8 0.4<br />

M25~0.75<br />

ø29<br />

ø32<br />

ø34<br />

0<br />

35˚<br />

1<br />

5 13 11.5 8 19 5.6<br />

CFI Fluor 10x W<br />

CFI Fluor 40x W<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI Fluor 10x W 0.30 2.0 20.0 4.06 210 Water dipping<br />

CFI Fluor 40x W 0.80 2.0 5.0 0.57 210 Water dipping<br />

CFI Fluor 60x W 1.0 2.0 3.3 0.37 210 Water dipping<br />

CFI Fluor 60x W<br />

CFI HMC 10x<br />

2nd Objective Lens Unit<br />

CFI HMC 20x F<br />

Objectives (magnification) N.A. W.D. (mm) Focal length (mm) Physical depth of focus (µm) Weight (g) Remarks<br />

CFI HMC 10x 0.25 5.2 20.0 4.40 130 Cover gl<strong>as</strong>s thickness 1.2mm<br />

CFI HMC 20x F 0.40 3.0 10.0 1.72 130 Cover gl<strong>as</strong>s thickness 1.2mm<br />

CFI HMC LWD 40x C 0.55 2.7–1.7 5.0 0.91 210 Cover gl<strong>as</strong>s correction0–2mm<br />

This unit is attached to infinity objectives when neither a<br />

binocular or trinocular eyepiece tube is used.<br />

• Infinity Tube Lens Unit for CFI objectives (chromatic aberrationfree<br />

infinity corrected objectives).<br />

• Focusing distance: 200mm (7.87 in.)<br />

• To obtain the optimal objective performance, keep the distance<br />

between the tube lens and the objective’s shoulder within<br />

100–200 mm (3.84–7.87 in.).<br />

28<br />

22.5<br />

M38~0.5<br />

5<br />

ø36f7 -0.025<br />

-0.050<br />

ø33<br />

CFI HMC LWD 40x C<br />

Approx. 70~170 148<br />

Image plane<br />

Objective's shoulder<br />

Plan Fluor<br />

100X / 1.30 oil<br />

DIC H<br />

/ 0.17 WD 0.20<br />

14<br />

2nd Objective Lens Unit<br />

15


CFI60 OBJECTIVES<br />

Markings on CFI60 Objectives<br />

Condensers<br />

2.5 58<br />

21<br />

ø27<br />

ø8<br />

30˚<br />

ø50<br />

14.5 6<br />

7.5<br />

(1) Magnification and Color Code<br />

A color coded ring on the barrel identifies<br />

the magnification of the objective:<br />

(2) Numerical Aperture (N.A.)<br />

N.A. is the most important factor in defining<br />

the performance characteristics of an objective.<br />

N. A.= n sin <br />

n: the refractive index of the media at d-line (587nm)<br />

For dry objective n=1.000 (air)<br />

For oil objective n=1.515 (oil)<br />

For water objective n= 1.333 (water)<br />

:Half angle of incident rays to the top lens of the objective<br />

The higher N.A., the higher resolving power.<br />

When the resolving power is defined <strong>as</strong> the power to<br />

recognize the two points,<br />

R=<br />

or<br />

(1) Magnification (2) Numerical Aperture<br />

(6) Application Markings<br />

<br />

N.A.<br />

R=<br />

<br />

N.A. Obj. +N.A. Cond.<br />

The higher N.A. the brighter image we take.<br />

2<br />

Brightness: B <br />

N.A.<br />

Total Magnification <br />

The higher N.A., the shallower the depth of focus (DOF).<br />

DOF = N.A. 2<br />

(1) Color Code<br />

(7) Immersion Oil—cleaning<br />

Mag. 1X 2X 4X 10X 20X 40X 50X 60X 100X<br />

Color code Black Gray Red Yellow Green<br />

Light<br />

Blue<br />

Light<br />

Blue<br />

Cobalt<br />

Blue<br />

White<br />

(3) Working Distance<br />

Working distance (W.D.) defines the distance between<br />

the top lens of the objective and the surface of the<br />

cover gl<strong>as</strong>s.<br />

CFI60 objectives can offer longer working distance with<br />

high numerical aperture.<br />

(3) Working Distance<br />

<strong>Nikon</strong> offers a wide variety of CFI objectives. To <strong>as</strong>sist the user they are clearly marked with information<br />

on the objective barrel such <strong>as</strong>: which DIC module or Ph<strong>as</strong>e Ring to use.<br />

n = 1.515<br />

Oil<br />

n = 1.000<br />

Dry<br />

Objective lens<br />

<br />

Cover Gl<strong>as</strong>s<br />

Slide Gl<strong>as</strong>s<br />

(4) Correction Ring<br />

Dry objectives with high Numerical Aperture are<br />

susceptible to spherical and other aberrations which<br />

can impair resolution and contr<strong>as</strong>t when used with a<br />

cover gl<strong>as</strong>s whose thickness differs from the specified<br />

value. A 1 1/2 cover gl<strong>as</strong>s (0.17mm thick) should be used<br />

<strong>as</strong> standard, however not all 11/2 cover gl<strong>as</strong>ses are<br />

exactly 0.17mm and many specimens have media<br />

between them and the cover gl<strong>as</strong>s. The correction ring<br />

is used to adjust for these subtle differences to ensure<br />

the optimum objective performance.<br />

How to use the correction ring<br />

Position the ring at 0.17. The thickness of the<br />

standard cover gl<strong>as</strong>s is 0.17mm.<br />

Focus the lens on a small artifact in the specimen.<br />

Rotate the ring very slightly and focus the lens again<br />

to check if the image h<strong>as</strong> improved or degraded.<br />

Repeat the above step to determine if the image is<br />

improving or degrading in the direction you are<br />

turning the ring.<br />

If the image h<strong>as</strong> degraded, follow the same<br />

procedure in the opposite direction to find the<br />

position offering optimum resolving power and<br />

contr<strong>as</strong>t.<br />

(5) Cover Gl<strong>as</strong>s<br />

For optimum performance, the thickness of the cover<br />

gl<strong>as</strong>s should be 0.17mm. For example, at N.A.=0.95, a<br />

0.01mm difference in thickness reduces image<br />

formation by 45% from the ideal image.<br />

N.A.<br />

0.3<br />

0.45<br />

0.7<br />

0.85<br />

0.95<br />

Difference in cover gl<strong>as</strong>s thickness<br />

0.01mm<br />

0.02mm<br />

100%<br />

100<br />

98<br />

81<br />

45<br />

(4) Correction Ring<br />

(5) Cover Gl<strong>as</strong>s<br />

100%<br />

100<br />

92<br />

43<br />

29<br />

(6) Application Markings<br />

DIC: for Differential Interference Contr<strong>as</strong>t<br />

DM: Ph<strong>as</strong>e contr<strong>as</strong>t, Dark contr<strong>as</strong>t middle type<br />

DL: Ph<strong>as</strong>e contr<strong>as</strong>t, Dark contr<strong>as</strong>t light type<br />

DLL: Ph<strong>as</strong>e contr<strong>as</strong>t, Lower contr<strong>as</strong>t type<br />

(7) Immersion Oil—cleaning<br />

After using immersion oil, gently blot the lens dry with<br />

lens tissue. Then slightly moisten a piece of lens tissue<br />

with petroleum benzene (Naphtha) and clean off all<br />

traces of the oil from the immersion objective. Cleaning<br />

is essential for water immersion objectives <strong>as</strong> well; after<br />

use, wipe the water off the top lens.<br />

Type N.A. Object distance (mm) Magnification<br />

C-C Abbe Condenser, Dry Type 0.9 1.9 4–100x<br />

C-C Achromat Condenser 0.8 4.2 4–100x<br />

Achromat Swing-out Condenser 0.9/0.22 1.8 2–100x<br />

C-C Achromat /Aplanat Condenser 1.40 1.6 10–100x<br />

LWD Achromat Condenser 0.65 10.2 4–40x<br />

C-C Low Power Condenser 0.13 10.2 1–4x<br />

Dark Field Condenser, Oil 1.2–1.43 1.5 20–100x<br />

Dark Field Condenser, Dry 0.8–0.95 4.0 20–40x<br />

16 17<br />

1.0<br />

(Slidgl<strong>as</strong>s thickness)<br />

55<br />

10<br />

R40<br />

ø55<br />

ø43<br />

ø40<br />

ø54<br />

ø59<br />

0.7<br />

8 54.9<br />

55.6<br />

C-C Abbe Condenser, Dry Type<br />

8 55.5 1<br />

(Slidgl<strong>as</strong>s thickness)<br />

0.6<br />

(Oil)<br />

54.4 -0.2<br />

0<br />

70˚<br />

ø54<br />

Achr-ADl N.A=1.4 JAPAN<br />

1.4 1.2 1.0 0.8 0.6 0.4 0.2<br />

ø40<br />

ø62<br />

C-C Achromat /Aplanat Condenser<br />

55 0.5<br />

14 9.5 (Oil)<br />

20<br />

70˚<br />

ø39<br />

ø34.5<br />

Dark Field Condenser<br />

Oil 1.43-1.20<br />

JAPAN<br />

ø40<br />

ø56<br />

Dark Field Condenser, Oil<br />

R40<br />

ø55<br />

ø36.8<br />

ø40<br />

ø54<br />

ø58<br />

2.0<br />

8 54.5<br />

56.5<br />

C-C Achromat Condenser<br />

1<br />

55.6<br />

54<br />

8<br />

(Slidgl<strong>as</strong>s thickness)<br />

1.5<br />

ø59<br />

ø54.5<br />

ø42<br />

ø36.8<br />

ø22<br />

ø40<br />

9<br />

12<br />

24.5<br />

LWD Achromat Condenser<br />

70˚<br />

20.6<br />

ø35.5<br />

Dark Field Condenser<br />

Dry 0.95-0.80<br />

JAPAN<br />

ø40<br />

ø56<br />

Dark Field Condenser, Dry<br />

29.8<br />

4.5˚<br />

8.6<br />

8<br />

Achr 0.90 JAPAN<br />

0.8 0.6 0.4 0.2<br />

54.8<br />

63.4<br />

ø60<br />

ø10<br />

34.5<br />

19<br />

13<br />

11.5<br />

4.5˚<br />

R40<br />

ø40<br />

Achromat Swing-out Condenser<br />

R40<br />

ø55<br />

ø38<br />

ø40<br />

ø54<br />

ø58<br />

8 58.7<br />

8.3<br />

67<br />

C-C Low Power Condenser<br />

C-CEL<br />

ø30<br />

11.5<br />

14.9<br />

8<br />

C-CEL Expander Lens (for darkfield)<br />

55<br />

70˚


Illumination Systems<br />

139<br />

168.5<br />

139<br />

50<br />

12 24.5 13.5<br />

90˚<br />

76<br />

3.5<br />

28.5<br />

15<br />

76<br />

7<br />

4<br />

4.6<br />

30 8<br />

Eyepiece Tubes<br />

(Center of lamp)<br />

30<br />

6.6<br />

67.8<br />

20.5<br />

37.8<br />

i35.5‘39.5j<br />

7<br />

ø57<br />

41.5<br />

ø67<br />

ø51<br />

ø71<br />

M50~0.75<br />

ø71<br />

ø61<br />

ø55<br />

105<br />

24<br />

61 (Center of lamp)<br />

105<br />

24<br />

61<br />

(Center of lamp)<br />

20.5<br />

3<br />

4<br />

171<br />

1 170<br />

80<br />

80.5<br />

Lamphouse HMX-3B<br />

171<br />

1 170<br />

80<br />

80.5<br />

Lamphouse HMX-4B, built-in back mirror<br />

(Datum clamp face)<br />

(Datum clamp face)<br />

C-LA HMX Lamphouse Adapter<br />

(Datum clamp face)<br />

(Datum clamp face)<br />

HMX Connecting Adapter SB-X1<br />

(Bayonet to Screw)<br />

M50~0.75-6H<br />

Sectional View<br />

HMX Connecting Adapter SB-X2<br />

(Screw to Bayonet)<br />

ø42<br />

4<br />

60<br />

80<br />

64<br />

77 69.5<br />

100<br />

70<br />

105 (Min. distance)<br />

50<br />

64<br />

(Tilting section)<br />

98<br />

100<br />

110<br />

Approx. 111<br />

90.5<br />

8 63<br />

R32<br />

R40<br />

Y-TB Binocular Tube<br />

8˚ (Min. angle)<br />

ø51.3<br />

5<br />

70<br />

50<br />

50.5 77<br />

Y-TE Ergonomic Binocular Tube<br />

120<br />

2<br />

ø56<br />

47<br />

68<br />

80<br />

109<br />

67.8<br />

137.3<br />

99.5<br />

81.5<br />

52.5<br />

40<br />

70 8.5<br />

26<br />

102<br />

20<br />

138.5<br />

76.5<br />

6<br />

136<br />

34<br />

2<br />

51<br />

10<br />

148<br />

Lamphouse HMX<br />

Mercury Lamp Socket S 100W for HMX-3B<br />

27.1<br />

135.9<br />

50<br />

ø50<br />

ø52<br />

16.5<br />

ø58<br />

ø52<br />

172<br />

10.3 0.6<br />

24 5<br />

(Center of pin)<br />

(Center of filament)<br />

218.5<br />

151.5<br />

ø59<br />

16.5<br />

3<br />

Halogen Lamp Socket 100W/HMX<br />

58.5<br />

100<br />

73.7<br />

38.5<br />

7.5<br />

12<br />

36 11<br />

3<br />

36.5<br />

12.5<br />

66.5<br />

102.5<br />

i239j<br />

76.5<br />

18<br />

ø45<br />

1.1<br />

ø33<br />

Center <br />

of <br />

lamp<br />

3 22<br />

ø3<br />

6<br />

C-FC Epi-Fl Collector Lens<br />

ø45<br />

ø36<br />

Center <br />

of <br />

lamp<br />

3 21<br />

Quartz Epi-Fl Collector Lens<br />

ø45<br />

Center of<br />

lamp<br />

3 22<br />

Collector Lens/QH100W<br />

Y-TF Trinocular Tube “F” UW<br />

Y-TT Trinocular Tube “T” UW<br />

Y-TB Binocular Tube<br />

F.O.V. 22mm<br />

Y-TE Ergonomic Binocular Tube F.O.V. 22mm with tilting angle of 8° to 32° and telescopic mechanism of ±15mm movement<br />

Y-TF Trinocular Tube “F” UW Two-way: 100 : 0 or 0 : 100 (observation : photo) F.O.V. 22mm or 25mm with eyepiece reticule orientation adjustment mechanism<br />

Y-TT Trinocular Tube “T” UW Three-way: 100 : 0, 20 : 80, or 0 : 100 (observation : photo) F.O.V. 22mm or 25mm with eyepiece reticule orientation adjustment mechanism<br />

19


Intermediate Tubes<br />

Nosepieces<br />

22.5<br />

22.5<br />

(Top View)<br />

50.5<br />

285.5<br />

175<br />

V-ND JAPAN<br />

V-N JAPAN<br />

264<br />

248<br />

80<br />

100<br />

100<br />

80<br />

126.5<br />

13.5<br />

57.5<br />

22<br />

50<br />

123.2<br />

50<br />

123.2<br />

3<br />

(Right-side View)<br />

ø52<br />

6<br />

1<br />

2<br />

53<br />

48<br />

2<br />

53<br />

48<br />

120.6<br />

55<br />

34.5<br />

20.5<br />

322<br />

353.5<br />

45 25<br />

5<br />

55<br />

45<br />

100<br />

0<br />

Y-IDP Double Port<br />

ø51<br />

V-NA Motorized Sextuple Nosepiece<br />

ø121<br />

V-ND MG-DIC Intelligent Sextuple Nosepiece<br />

ø121<br />

Y-FL Epi-Fl Attachment<br />

Eyepieces<br />

22.5<br />

22.5<br />

48–56<br />

48–56<br />

22.5<br />

22.5<br />

C-ND DIC6<br />

JAPAN<br />

ø30<br />

CFI 10X / 22<br />

ø34<br />

ø38.8<br />

ø30<br />

CFI 10X / 22M<br />

ø34<br />

ø38.8<br />

50<br />

105.8<br />

50<br />

123.2<br />

CFI 10x with diopter adjustment<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment<br />

22.5<br />

42–47<br />

22.5<br />

37–41<br />

ø30<br />

CFI 12.5X / 16<br />

ø35<br />

ø38.8<br />

ø30<br />

CFI 15X / 14.5<br />

ø35<br />

ø38.8<br />

53<br />

51.1<br />

48<br />

53<br />

48<br />

ø106<br />

ø121<br />

C-N Sextuple Nosepiece<br />

C-ND Sextuple DIC Nosepiece<br />

CFI 12.5x with diopter adjustment<br />

CFI 15x with diopter adjustment<br />

Type (magnification) F.O.V. Remarks<br />

CFI 10x with diopter adjustment<br />

22mm<br />

CFI 10x M Photom<strong>as</strong>k with diopter adjustment 22mm With photom<strong>as</strong>k reticule<br />

CFI 12.5x with diopter adjustment<br />

16mm<br />

CFI 15x with diopter adjustment<br />

14.5mm<br />

20<br />

21


CCTV Camera Adapters<br />

Focal point<br />

Focal point<br />

3<br />

72<br />

27<br />

ø52<br />

35<br />

ø12<br />

9.3<br />

ø51<br />

ø38<br />

76.5<br />

C-mount screw<br />

41<br />

25.5<br />

TV camera imaging plane<br />

ø50<br />

ø25.4<br />

ø38<br />

11.47 17.526<br />

30˚<br />

C-Mount TV Adapter A<br />

ø23.1<br />

ø42<br />

ø53<br />

17.526<br />

30.7 27.3 4<br />

100.1<br />

C-Mount TV Adapter 0.45x<br />

ø23.1<br />

ø42<br />

ø53<br />

17.526<br />

30.7 27 4<br />

116.8<br />

C-Mount TV Adapter 0.6x<br />

Focal point<br />

ø38<br />

ø52<br />

ø38<br />

ø59<br />

Focal point<br />

V-T Photo Adapter<br />

Y-T TV Tube for C-Mount Adapter A<br />

38<br />

48<br />

ø34<br />

ø30<br />

44<br />

31<br />

Relay Lens 1x I<br />

ø58.5<br />

ø54<br />

75<br />

10<br />

Image plane <br />

on eyepiece tube side<br />

ø31<br />

ø42<br />

ø46<br />

45˚<br />

7.5<br />

27.3<br />

64.5<br />

C-Mount TV Adapter<br />

91.8 17.526<br />

95.8<br />

ø42<br />

ø47<br />

ø62<br />

ø63<br />

27.8 11.5<br />

ENG-Mount TV Adapter<br />

53.3<br />

61.3}0.1 48<br />

64.3<br />

ø23.1<br />

ø42<br />

ø53<br />

30.2 27<br />

4<br />

111.2<br />

ENG-Mount TV Adapter 0.45x<br />

(for Trinocular Tube “F”, “T”)<br />

ø23.1<br />

ø42<br />

ø53<br />

30.2 27.0<br />

3.3<br />

122.8<br />

ENG-Mount TV Adapter 0.6x<br />

(for Trinocular Tube “F”, “T”)<br />

Focal point<br />

130<br />

67.3<br />

40.2<br />

JAPAN<br />

ø44<br />

ø54<br />

C-mount screw<br />

45˚<br />

11.5 4<br />

7.5 42.8 17.526<br />

54.3<br />

ø44<br />

ø57<br />

48<br />

12.3<br />

7.5<br />

22.8<br />

Focal point<br />

ø53<br />

ø38<br />

42 29<br />

68<br />

ø53<br />

29<br />

83<br />

109<br />

ø23.1<br />

C-Mount Zooming Adapter<br />

ENG-Mount Zooming Adapter<br />

C-Mount TV Adapter VM 2.5x<br />

ø42<br />

ø38<br />

Zoom Lens<br />

C-Mount TV Adapter VM 4x<br />

22<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!